The Meibes concept for the specialist: Easier. Quicker. More successful.

Similar documents
C B SOLARTHERMAL. Solar thermal systems

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Technical Product Guide

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Installation and instruction manual SOLAR STATION

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Roth fixed-value control set with high-efficiency pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Systems for central heating

Solar heating systems

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Storage tank size Rated volume [l] Actual volume [l]

Components for solar heating systems

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)

LK Heat Exchanger Pack 10 -n

Technical information for installation and operation

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

CITY OPEN - CITY BOX from 25 to 35 kw

TERMO Combi Cylinder TECHNICAL INFORMATION

Wood Boiler Plumbing Schematics

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Protection and Control of Solid Fuel Boilers

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Starting current with soft starter Fuse protection

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

We regulate and supply clean energy

Thermostatic valves with radiator connection systems

CIRCO 6 Solar Circulation Unit

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Starting current with soft starter Fuse protection

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Trade Product List 2013 BIOMASS ACCESSORIES

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

product overview ProControl

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Thermostatic valve bodies

REMKO HYBRID HEAT PUMPS

Mercury Mixing Kit (Code: ME1053)

FHM-Cx Mixing Shunts for Floor Heating

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw

REMKO Comfort-WP The versatile heat pump

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data

WOLF VENTILATION SYSTEM PRICE LIST

HERZ Differential Pressure Control Valve 4002

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Manual and installation instructions. Function. Operating phase

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

WZS series. Hot water circulation systems for energy storage tanks

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Smart temperature control solutions

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

TS RD 7761 RD, 7761 RD

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

Thermostatic valve bodies

Xpert HD Xpert HD 7140, ,

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

Lowara ecocirc and ecocirc PREMIUM

Say heating. Say Herz. HERZ-Supply Engineering

MODEL CMA-180UC PARTS MANUAL Rev 1.16

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Control valves for floor heating systems. Floor Heating Manifolds

KEMPER ThermoSystem. For further information on KTS use the QR code!

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Starting current with soft starter Fuse protection. Heat source connection

HERZ Regulating valve 4002

english Steca Solar Thermal hot water from the sun. Solar Thermal

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Cold water compact class HD 5/15 C

Cold water compact class HD 5/17 C

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

WOLF GAS CONDENSING BOILERS COMFORTLINE

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

Cold water compact class HD 5/12 C

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Transcription:

P R I C E L I S T 3 5 V A L I D F R O M 0 1. 0 1. 2 0 1 0...for the professional installer

The Meibes concept for the specialist: Easier. Quicker. More successful. Easier Complete pre-assembled modules ensure that you have everything you need exactly where you need it, on the spot, at the right time and at the right quality. Quicker Time is money, particularly in our business. Meibes systems are rapid installation designs, completely pre-assembled and sealed. All connections are flat-sealing; simply tighten the union nut, and the job s done. This cuts down on assembly time, makes every installation secure and reliable and prevents any unpleasant surprises if it comes to recalculation. More successful Rapid installation technology makes sure you stay one step ahead with every quotation you make. Shorter installation times mean less labour costs, and that means less entrepreneurial risk and lower prices. Meibes are the pioneers in rapid installation techniques, and for more than 40 years Meibes products have been the key to suc cess in the profession. And to make sure you maintain your lead tomorrow as well as today, Meibes keep developing new products and new ideas all the time. The energy label Leading manufacturers of heating pumps have committed themselves to a voluntary and uniform system of energy consumption identification. With the help of energy consumption data, the energy label makes a comparison between individual pumps easy. The label is subdivided into energy coefficient classes from A to G, with Class A standing for particularly economical and G signifying high energy consumption.

Find what you need, choose it, and order it faster: Systems for boiler connection from page 2 Foor standing boiler from page 3 Pump groups, meter groups, constant temperature control set, separation system, manifolds, accessories, expansion set, pipe connection group, safety set, shut-off set Wall boiler from page 14 Thermix mixer circuit Thermix separation system Accessories Heat pump systems from page 18 Heat pump connection groups Brine manifolds Systems for solar power from page 20 Solar stations S M L XL XXL Solar separation systems, accessories, connection technology NEW Systems for domestic water heating NEW ab Seite 48ab Logofresh fresh water station, accessories Systems for large-scale systems ab Seite 52 NEW manifolds, pump groups, Heating control / hydraulic switch point, accessories Systems for flexible connections ab Seite 62 Inoflex stainless steel corrugated pipes, accessories, Fixlock connections, Inoflex Meiflex armoured hoses (for heating, air condition, drinking water) Meiflex silicone armoured hoses, hose accessories, gas pressure hoses Fittings ab Seite 74 Expansion compensators, gravity brakes, pump gate valves, ball valves, Meipass elements, connection fittings, automatic mixer elements, ring air bleeders, safety valves, thermometers, strainers, fill fittings, KFE/KFR ball valves, expansion vessel service coupling / cap valves, quick air bleeders, compension fittings Checklist for enquiries Seite 82 Fresh water station, systems for large-scale Additional price lists Seite 85 Logotherm Water manifold An index is provided on page 84! 1

Systems for boiler connection Floor standing boiler components Systems for boiler connection Universal for all boiler types and makes The product: A B C Item reference Designation A Domestic hot water C B Radiator C D under floor heating Heat generator 2 3 4 E Solid fuel boiler 1 5 Item reference 1 Constant temperature regulating page 10 6 setregulation set 7 2 pump group direct circuit 4 3 pump group mixed circuit 5 4 Split System 9 5 Servomotor 10 8 7 6 Manifold block 10 7 Constant return temperature 8 8 Universal pipe connection group 11 9 Connection set for expansion vessel 11 D 8 10 Safety group 11 8 E Note: No application example 9 2

Pump group Edition 7 Components for standing boiler Boiler connection The product: complete range from 3/4 to 1 1/4 Same dimensions and appearance for all sizes Complete equipment with wall mounting DC (direct circuit) and MC (mixed circuit) with three-way mixer with steplessly adjustable bypass Your advantage: Complete range with sophisticated design Same dimensions from 3/4 to 1 1/4 All versions with rapid installation technology, fat-sealing 100% sealing tightness tested, for immediately use Likewise available in the same design: NEW With inspection window for high-efficiency pumps Heat regulation system for return pipe Constant heat regulation set Split system 3

Pump groups DC Meibes pump group Edition 7 (direct circuit) Complete with circulating pump (EL 180 mm) with 2 m connection cable, two 3-way ball valves (one with manually-positioned gravity brake), two contact thermometers, pump ball valve, stabilizer between flow and return pipes, wall mount, return pipe, EPP insulation, all completely assembled. RL VL Version: Art. No../each. 3/4 without Pump 66710 EA 153,00 3/4 with Grundfos-Pump UPS 25-40 66710 243,00 3/4" with Grundfos-Pump Alpha2 25-60 A 66710.30 450,00 3/4 with Wilo-Pump RS 25/4 66710 WI 239,00 3/4 with Wilo-Pump Star E 25/1-5 66710.60 WI 347,00 3/4" with Wilo-Pump Stratos Para 25/1-7* A 66710.31 WI 430,00 3/4" with Stratos PICO 25/6 A 66710.32 WI 450,00 1 without Pump 66711 EA 153,00 1 with Grundfos-Pump UPS 25-40 66711 243,00 1 with Grundfos-Pump Alpha2 25-60 A 66711.30 450,00 1 with Wilo-Pump Star RS 25/4 66711 WI 239,00 1 with Wilo-Pump Star E 25/1-5 66711.60 WI 347,00 1" with Wilo-Pump Stratos Para 25/1-7* A 66711.31 WI 430,00 1" with Stratos PICO 25/6 A 66711.32 WI 450,00 1 1/4 with Pump 66712 EA 230,00 1 1/4 with Grundfos-Pump UPS 32-40 66712 327,00 1 1/4 with Grundfos-Pump Alpha2 32-60 A 66712.30 537,00 1 1/4 with Wilo-Pump Star RS 30/4 66712 WI 319,00 1 1/4 with Wilo-Pump Star E 30/1-5 66712.60 WI 425,00 1 1/4" with Wilo-Pump Stratos Para 30/1-7* A 66712.31 WI 517,00 1 1/4" with Stratos PICO 30/6 A 66712.32 WI 537,00 *incl. additional option: Control signal 0-10 V The installation and assembly instructions from the manufacturers are to be respected. Technichal Data DN : 20 25 32 Upper connection: : G 3/4 IG G 1 IG G 1 1/4 IG Lower connection: : G 1 1/2 AG (fat-sealing) Pump: : see ref. number Axial separation: : 125 mm Components of... Steel, Brass, EPP insulation Dimensions: ca. H 420 x W 250 x D 246 mm Sealing materials: PTFE fiber joint free of astbestos Temperature display: from 0 up to 120 C Operating temperature: up to 110 C Kvs values: 8,5 9,7 11 Pressure PN 6 pressure loss [bar] Flow diagram: volume flow-pressure loss-diagram pump group DC Note: flow and return sides can be switched over. Can also be fitted subsequently with overflow valve (see p.10). volume flow flow [l/h] [l/h] 4

Meibes pump group Edition 7 MC (mixed circuit), 3-way T-mixer with fully adjustable bypass Complete with circulating pump (EL 180 mm) with 2 m connection cable, two 3-way ball valves (one with manually-positioned gravity brake), two contact thermometers, 2-way T-mixer, stabilizer between flow and return pipes, return pipe, wall mount, EPP insulation, all completely assembled. Pump groups MC Boiler connection RL VL Version: Ref.-No. Art.No../each. (VL left) (VL right) 3/4" without Pump 66730 EA 220,00 3/4 with Grundfos-Pump UPS 25-40 L 66730 66730 310,00 3/4" with Grundfos-Pump Alpha2 25-60 A 66730.30 517,00 3/4 with Wilo-Pump RS 25/4 L 66730 WI 66730 WI 306,00 3/4 with Wilo-Pump Star E 25/1-5 L 66730.60 WI 66730.60 WI 414,00 3/4" with Wilo-Pump Stratos Para 25/1-7* A 66730.31 WI 497,00 3/4" with Stratos PICO 25/6 A 66730.32 WI 517,00 1 without Pump 66731 EA 220,00 1 with Grundfos-Pump UPS 25-40 L 66731 66731 310,00 1 with Grundfos-Pump Alpha2 25-60 A 66731.30 517,00 1 with Wilo-Pump Star RS 25/4 L 66731 WI 66731 WI 306,00 1 with Wilo-Pump Star E 25/1-5 L 66731.60 WI 66731.60 WI 414,00 1" with Wilo-Pump Stratos Para 25/1-7* A 66731.31 WI 497,00 1" with Stratos PICO 25/6 A 66731.32 WI 517,00 1 1/4 ohne Pump 66732 EA 307,00 1 1/4 with Grundfos-Pump UPS 32-40 L 66732 66732 404,00 1 1/4 with Grundfos-Pump Alpha2 32-60 A 66732.30 614,00 1 1/4 with Wilo-Pump Star RS 30/4 L 66732 WI 66732 WI 396,00 1 1/4 with Wilo-Pump Star E 30/1-5 L 66732.60 WI 66732.60 WI 502,00 1 1/4" with Wilo-Pump Stratos Para 30/1-7* A 66732.31 WI 594,00 1 1/4" with with Stratos PICO 30/6 A 66732.32 WI 614,00 *incl. additional option: Control signal 0-10 V The installation and assembly instructions from the manufacturers are to be respected. Technichal Data DN 20 25 32 Upper connection: 3/4 female 1 female 1 1/4 female Lower connection: 1 1/2 male (flat-sealing) Pump: See Article No. Axial separation: 125 mm Components of... Steel, Brass, EPP insulation Dimensions: Approx. H 420 x W 250 x D 246 mm Sealing materials: PTFE, asbestos-free fibre seal, EPDM Temperature display: from 0 up to 120 C Operating temperature: up to 110 C Kvs values: 6,0 6,2 6,4 Pressure PN 6 Flow diagram: pressure loss [bar] volume flow-pressure loss-diagram pump group MC with 3-point Valve Actuator Note: Two types (flow left or flow right). Servomotor for mixer can be fitted subsequently (see page 10), volume flow [l/h] 5

Pump groups with meter spool piece RL VL Pump group Edition 7 with section for counter unit Complete with circulating pump (EL 180 mm) with 2 m connection cable, two 3-way ball valves (one with manually-positioned gravity brake), two contact thermometers integrated in ball valve handle, pump ball valve, stabilizer between flow and return pipes, wall mount, meter spool piece with telescoping piece, sensor sleeve 1/2, EPP insulation, piping and screw joint parts, all completely assembled. Fitting dimension: 3/4 90-110 mm Fitting dimension: 1 90-130 mm Pump group Edition 7 UK-Z (direct circuit) Version: Art. No../each. 1 without Pump 66711 ZEA 222,00 1 with Grundfos-Pump UPS 25-40 66711 Z 312,00 1" with Grundfos-Pump Alpha2 25-60 A 66711.30 Z 519,00 1 with Wilo-Pump RS 25/4 66711 ZWI 309,00 1" with Wilo-Pump Stratos Para 25/1-7* A 66711.31 ZWI 499,00 RL VL Meibes pump group Edition 7 (mixed circuit with section for counter unit) 3-way T-mixer with fully adjustable bypass Version: Art. No../each. 1 without Pump 66731 ZEA 292,00 1 with Grundfos-Pumpe UPS 25-40 66731 Z 382,00 1" with Grundfos-Pumpe Alpha2 25-60 A 66731.30 Z 589,00 1 with Wilo-Pumpe RS 25/4 66731 ZWI 378,00 1" with Wilo-Pumpe Stratos Para 25/1-7* A 66731.31 ZWI 569,00 *incl. additional option: Control signal 0-10 V The installation and assembly instructions from the manufacturers are to be respected. See pages 4 and 5 for technical information and differential pressure diagrams. 6

Constant heat regulation set Constant heat regulation set/edition 7 3-way T-mixer with fully adjustable bypass The constant heat regulation set is a heating circuit with a mixer for under floor heating. The flow temperature can be adjusted at the 3-way T-mixer. Water from the return is mixed into the flow through the adjustable bypass, and the quantity of water circulating in the heating circuit is increased as a result. A surface thermostat allows for a temperature delimitation safeguard to be implemented. In the event of the flow temperature being exceeded the pump is switched off. Constant temperature control set, regulated by thermostat Complete with circulating pump (EL 180 mm) with 2 m connection cable, two 3-way ball valves (one with manually-positioned gravity brake), two contact thermometers, 3- way T-mixer, thermostat head with remote sensor (adjustment range 25-50 ºC), surface thermostat, wall mount, return pipe, EPP insulation, all completely assembled. Boiler connection Flow diagram flow rate/pressure loss diagram, constant heat regulation set Version: Art. No../each. 1 without Pumpe 45190 EA 327,00 1 with Grundfos-Pumpe UPS 25-60 45190 423,00 1" mit Grundfos-Pumpe Alpha2 25-60 A 45190.30 624,00 1 mit Wilo-Pumpe RS 25/6 45190 WI 419,00 1" mit Wilo-Pumpe Stratos Para 25/1-7 A 45190.31 WI 604,00 Constant heat regulation set, electronically regulated As above, but with 3-point actuator (230 V AC, 50 Hz), including flow temperature regulation, (adjustment range 20-80 ºC); flow temperature sensor integrated in flow ball valve. Version: Art. No../each. 1 without Pump 45190.5 EA 521,00 1 mit Grundfos-Pump UPS 25-60 45190.5 617,00 1" with Grundfos-Pump Alpha2 25-60 A 45190.50 818,00 1 with Wilo-Pump RS 25/6 45190.5 WI 613,00 1" with Wilo-Pump Stratos Para 25/1-7 A 45190.51 WI 798,00 *incl. additional option: Control signal 0-10 V The installation and assembly instructions from the manufacturers are to be respected. Technical data DN 25 Upper connection: 1 FI Lower connection: 1 1/2 MI (fat-sealing) Pump: see ref. number Axial separation 125 mm Components of Steel, brass, EPP insulation Dimensions Approx. H 500 x W 250 x D 246 mm Sealing materials PTFE, asbestos-free fibre seal, EPDM Temperature display 0 to 120 ºC Operating temperature Up to 110 ºC/ Only 60 ºC in the mixing circuit Operating pressure PN 6 flow rate/pressure loss diagram, constant heat regulation set with 3-point actuator pressure loss [bar] pressure loss [bar] flow rate [l/h] 7 flow rate [l/h]

Heat regulation system for return Return temperature regulation/edition 7 The return heat regulation system is mounted beneath the manifold joint. Depending on the temperature of the return at the boiler entry, flow water is mixed into the boiler return. The result of this is that the boiler attains its operating temperature faster, and in service the return temperature does not fall below a pre-adjustable value. The aim is to avoid condensation in the combustion chamber (increasing the service life) and reducing the emission of pollutants. The level of the minimum return temperature depends on the boiler type. Constant return temperature, regulated by thermostat Complete with circulating pump (EL 180 mm) with 2 m connection cable, two 3-way ball valves (one with manually-positioned gravity brake), two contact thermometers, thermostat valve (adjustment range 30-65 ºC), return temperature sensor in the return ball valve, T-piece, wall mount, return pipe, EPP insulation, all completely assembled. Version: Art. No../each. 1 without Pump 45441.3 EA 399,00 with Grundfos-Pumpe UPS 25-60 45441.34 495,00 with Wilo-Pumpe RS 25/6 45441.36 WI 491,00 Constant return temperature, electronically regulated As above, but with 3-way T-mixer and 3-point actuator (230 V AC, 50 Hz), including return temperature regulation, (adjustment range 20-80 ºC). 1 without Pump 45441.5 EA 439,00 with Grundfos-Pump UPS 25-60 45441.54 535,00 with Wilo-Pumpe RS 25/6 45441.56 WI 531,00 The installation and assembly instructions from the manufacturers are to be respected. Technical data DN 25 Upper connection: manifold connection 1 1/2 F (fat-sealing) Lower connection: Boiler connection 1 F Pump (in return line) See Article No. Axial separation 125 mm Components of Brass, EPP insulation Dimensions Approx. H 420 x W 250 x D 246 mm Sealing materials PTFE, asbestos-free fibre seal, EPDM Temperature display 0 to 120 ºC Operating temperature Up to 110 ºC Operating pressure PN 6 Flow diagrams Flow rate/pressure loss diagram, constant heat regulation set Flow rate/pressure loss diagram, constant heat regulation set with 3-point actuator pressure loss [bar] pressure loss [bar] flow rate [l/h] flow rate [l/h] 8

Split system Edition 7 For connection to the regulated heating circuit. Complete with circulating pump (EL 180 mm, red brass) with 2 m connection cable, two 3-way ball valves (one with manually-positioned gravity brake), two contact thermometers, compact heat exchanger with 20 or 30 plates, safety group with safety valve, 3 bar, and pressure gauge 0-4 bar, 2 fill-ball valves, return pipe, wall mount, EPP insulation, screw connections for the primary circuit, optionally 1 female or male thread. Including connection set for an expansion vessel with expansion vessel service coupler. Split system Boiler connection Version: Art. No../each. 1" with Grundfos-Pump UPS 25-40 RG 20 plates 45411.20 699,00 1" with Grundfos-Pump UPS UPS 25-60 RG 30 plates 45411.30 776,00 1" with Grundfos-Pump UPS UPS 25-60 RG 36 plates 45411.30 798,00 *Not in scope of supply Technical data Split system type 45411.20 45411.30 45411.36 Max capacity (secondary circuit 35 C/45 C) and (primary circuit 70 C/50 C ) 22 kw 25 kw 25 kw Maximum pressure 3 bar 3 bar 3 bar Maximum temperature 130 C 130 C 130 C Installation height with insulation 420 mm 420 mm 420 mm Width with insulation 250 mm 250 mm 250 mm Depth with insulation 246 mm 246 mm 246 mm Insulation material EPP EPP EPP Axial separation: 125 mm 125 mm 125 mm Upper and lower connection 1 FI 1 FI 1 FI Heat exchanger 20 30 36 Number of plates Max. pressure loss 20 kpa 30 kpa 36 kpa Heat exchanger: Plate material W No. 1.4401, solder material copper (99.9%) Flow diagrams Flow Rage-Pressure Loss-Diagram Separation System Primary Side (Heat Exchanger) Flow Rate-Pressure Loss-Diagram Separation System Secondary Side Heat exchanger plates 20 Heat exchanger plates 20 pressure loss [bar] Heat exchanger plates 30 Heat exchanger plates 36 pressure loss [bar] Heat exchanger plates 30 Heat exchanger plates 36 flow rate [l/h] flow rate [l/h] 9

Components for boiler connection systems 1 2 3 Version: Art. No../each. Clamp ring screw connection Converter screw fitting 1 G 29611.14 6,60 G 29611.15 13,20 Overflow set 2 For easy installation between the 3-way ball valves of pump groups, DC/MC, for automatic pressure compensation. Overflow valve including scale and visual display. 69070.5 28,20 Servomotor including mounting set 3 With 2 m cable, wired for direct installation onto the mixer of the mixed circuit groups, 230 V/50 Hz, running time 140 secs., 90º, 5 Nm with emergency manual operation and visible setting display. 66341 121,00 Mounting set for mixers prior to year of manufacture 66341.02 4,90 Servomotor For operation on heating controllers with relay output, e.g. Viessmann Vitotronik 200KW2. Further technical data as Art. No. 66341. 66341.4 146,00 4 5 Servomotor with integrated temperature control including mounting kit 5 With 2 m cable, wired for direct installation onto the mixer of the mixed circuit groups, 230 V,50 Hz, running time 150 secs., 90º, 10 Nm, setting range 20...80 ºC with emergency manual operation and visible setting display. Temperature sensor D=6 mm, incl. 2 m cable wired with actuator 66341.31 356,00 Screw fitting set 4 For connecting the pump groups with other makes of pipe connections, consisting of 2 union nuts, 2 seals, and 2 inserts. Not required with the use of the Meibes boiler connection group system. 1 female 66305.1 9,40 1 1/4 female 66305.2 21,60 Manifold blocks, standard EPP insulation, each with 2,3 or 4 pairs of connections above or below, for installation of assemblies direct and mixed circuit (universal fitting with 3/4, 1 and 1 1/4 pump groups), also to fit pipe connection groups, complete with the necessary screw fittings and connection parts. EPP-isulation. Power up to 70 KW ( T= 20 K) Manifold blocks, low differential pressure Manifold blocks, low differential pressure, for use with wall-mounted boilers, calorific devices, and boilers with integrated pumps. Connections and performance values as for standard manifold blocks. circuits Ref.-No. (standard) Ref.-No. (pressureless)./each up to 3 circuits 66301.2 66301.22 169,00 up to 5 circuits 66301.3 66301.31 225,00 up to 7 circuits 66301.4 66301.43 284,00 Stainless steel - manifold block Thermally split flow and return pipes, complete with EPS insulation and the necessary screw fittings and connection parts for capacities up to 70 kw (with deltat = 20K). 2 circuits 66306.1 D 169,00 3 circuits 66301.41 D 271,00 Wall brackets Pair, with screws and dowels for manifold blocks 66337.3 39,40 10

Components for boiler connection systems Boiler connection 125 Version: Art. No../each. 125 Axial separation horizontally and vertically 125 mm. With 3 functions: Hydraulic switch points, air and gas separator, and dirt and sludge trap, including immersion sleeves for flow line sensor, with diameter up to 10 mm and insulation. Can be used for heating systems up to 70 kw. Typ Type (delivery quantity) Capacity (at deltat=20k) Side connection Art.No../each Safety group with hydraulic switch points MHK 25 (m 3 /h=2) kw = 50 DN 25 66391.2 189,00 MHK 32 (m 3 /h=3) kw = 70 DN 32 66391.3 193,00 Safety group without hydraulic switch points MHK 25 (m 3 /h=2) kw = 50 DN 25 66390.2 189,00 MHK 32 (m 3 /h=3) kw = 70 DN 32 66390.3 193,00 Safety group K Completely sealed and insulated. Consisting of: Manifold piece with? female connection, including safety valve 1/2 x 3/4 ; 3 bar, with pressure gauge 4 bar and automatic air bleeder. 66065 41,50 Universal connecting tubes DN 25/32 With pipe insulation for direct mounting of pump groups or manifolds on the boiler. Thanks to the Inoflex stainless steel corrugated pipe provided, this can be used universally for all boilers. Flow connection: Flanged bend piece with union nuts and seals, completely insulated. Return circuit connection: 1000 mm Inoflex stainless steel corrugated pipe with union nuts and seals, completely insulated. Two compact manifolds: (side connections can also optionally be used for the connection of a boiler charge set and an expansion set) safety group, union nuts and seals. Complete with rapid air bleeder, safety valve, pressure gauge and expansion set. DN 25/32 66362 FR 258,00 Expansion vessel connection set With angled wall mounting for direct flexible connection to the return. Consisting of Meiflex 3/4 armoured hose, female flat-sealing on both sides, 700 mm long, two 3/4 seals, expansion vessel service coupling (for separating the expansion vessel without having to empty the system), angled wall mounting with two screws, washers and dowels for wall mounting. For expansion vessels with max. diameter of 440 mm. 66326.11 35,90 Connection set between hot water tank/boiler Two Meiflex stainless steel armoured hoses, female/male, insulated. Automatic air-bleeding device with automatic cut-off, T-piece, angled gravity brake with manual adjustment and air lock, pump, with 2 m cable, wired, angle screw connection, straight screw connection, KFE ball valve, two ball valves female/male, female/male angle element, with Grundfos-Pump UPS 25-40 1 length of hoses = 1000 mm 66356.100 278,00 1 length of hoses = 1500 mm 66356.150 291,00 with Wilo-Pump Star RS 25/4 1 length of hoses = 1000 mm 66356.100 WI 274,00 1 length of hoses = 1500 mm 66356.150 WI 287,00 As above, but without armoured hose (for supplement by Inoflex corrugated pipe, see pages 57-59). with Grundfos-Pump UPS 25-40 1 66356 OS 218,00 with Wilo-Pump Star RS 25/4 1 66356 OS WI 214,00 11

Direction of flow Direction of flow Direction of flow Shut of sets Version: Art. No../each. Pump shut-off set C, withhout gravity brake Ball valve with Meibes fange; red thermometer integrated into ball valve handle, two union nuts and seals b R C a 1 (a = ca. 359 mm) (Figure) 61122 37,20 1 1/4 (a = ca. 370 mm) 61124 60,50 180 Return set R, with gravity brake Ball valve with integrated gravity brake with manual adjustment and thermometer in the handle; screw connection. Pump not included in delivery 1 (b = approx. 117 mm) (Figure) 61126 26,90 1 1/4 (b = approx 118 mm) 61128 41,90 Pump shut-off and return set C + R Complete pump shut-off set Type C and return set Type R, gravity brake in the return. 1 (a = approx. 359 mm; b = 117 mm) (Figure) 61127 61,00 1 1/4 (a = approx 370 mm; b = 118 mm) 61129 100,00 a Pump shut-off set S with gravity brake for storage tank connection Scope of supply without pump 180 Ball valve (suction side) with thermometer in the handle; integrated gravity brake with manual adjustment and Meibes flange ball valve (pressure side) with handle and Meibes flange; two universal nuts and seals. 1 (a = approx. 359 mm) (Figure) 61130 39,00 1 1/4 (a = approx 370 mm) 61132 61,10 Pump shut-off and return set M b a On flow side, consisting of ball valve with Meibes flange, including gravity brake with manual adjustment and air lock, thermometer red, screw connections and seals, 3-way mixer (kvs = 7.3 / return connection? male) and actuator (see page 10 for technical data). Scope of supply without pump 180 Return side consisting of ball valve with thermometer blue 1 (a = approx. 428 mm; b = 151 mm) (Figure) 61827.3 206,00 M 12

Direction of flow Direction of flow Shut of sets Version: Art. No../each. Boiler connection B Pump shut-off set B Pump ball valve; pump ball valve with integrated gravity brake and air lock, complete with two union nuts and seals. 180 1 a = approx. 353 mm 61821.0 35,00 1 1/4 a = approx. 369 mm 61825 59,80 Scope of supply without pump 125 mm Circontrol C b Scope of supply without pump 180 a As for pump shut-off set C + R, but 3-way ball valves on the pressure side and in the return. Additionally with overflow valve with visible scale to avoid flow noise (can also be fitted subsequently and replaced even under pressure). 1 (a = approx. 359 mm; b = 117 mm) (Figure) 69175 97,10 1 1/4 (a = approx 370 mm; b = 118 mm) 69165 143,00 Air heater shut-off set Complete separable shut-off unit for flow and return connection Straight version (Figure) Two 1 flanged ball valves, each with two side connections 3/8 female (with one connection each, for example for thermometers or measuring sensors, closed off with plugs), automatic air bleeding device with shut-off in flow line, drain valve in return line, two straight screw connections 1 female. 1 45401 78,60 Angled version: Scope of supply as above, but instead of straight screw connections with angled screw connections 1 female 1 45402 90,10 1 1/4 version on enquiry. 13

Thermix Thermix Complete mixer circuit for wall-mounted boilers Specially developed for wall-mounted boilers, suitable for all makes/types. The product: Specially for wall-mounted boilers Installation below or next to the boilers With individual flexible connections for all makes/types With integrated primary bypass Motor variants for all devices with 3-point control Design product, very user-friendly With servomotor or thermostat injection valve Capacity table available on enquiry Your advantages: Small and handy, with the very latest technology Easy to install thanks to rapid installation technology Attractive design, also for use in living areas Installation example: wall-mounted boiler Meibes Thermix flow meter display regulating valve regulating valve Under floor heating Radiator circuit Connection example of a direct and mixed heating circuit with Thermix. Two compensating valves are used for regulating the required flow rates for the two heating circuits. 14

Thermix with mixer motor Thermix Thermix compact block made of brass with integrated primary bypass, mixer with adjustable bypass and integral servomotor, pump with 2 m connection cable, immersion sleeve for flow circuit sensor, air bleeding plugs, connection set for installation beneath the wall-mounted boiler consisting of two T-pieces and two flexible stainless steel connections, sealing set, EPP insulation, completely pre-assembled and tested for sealing tightness. Version: Art. No../each. Boiler connection with Grundfos Pump UPS 15-50 MBP 27400 434,00 with Grundfos-Pump Alpha2 15-60 A 27400.3 641,00 with Wilo Pump HU 15/4-2-3 27401 439,00 with Wilo Pump HU 15/6-2-3 27401.1 444,00 Thermix V with thermostat valve As above, but with thermostatic injection valve for wall-mounted boiler without mixer circuit control. The desired flow temperature is set at the thermostat valve. (Adjustment range: 25 C-50 C) with Grundfos Pump UPS 15-50 MBP 27409.2 434,00 with Grundfos-Pump Alpha2 15-60 A 27400.3 641,00 with Wilo Pump HU 15/6-2-3 27409.1 444,00 Technical data Upper connection 3/4 male (boiler-side) Lower connection 3/4 male Eurokonus (low-temperature circuit) Axial separation 42 mm Pump See Article No. Components of Extruded brass, brass, and EPP insulation Dimensions Approx. H 280 x W 225 x D165 mm (basic version) Sealing materials O-ring EPDM Temperature display 0 to 120 ºC Operating pressure Up to 6 bar kvs value: 2.8 Max. temperature: 110 ºC Attention! If Thermix is used in the basic version, with operating temperatures (primary side) of above 55 ºC the safety module Art. No. 27410.6 (see page 17) is required. Flow diagram Volumetric flow rate Pressure loss diagram Thermix Volumetric flow rate Pressure loss diagram Thermix- V pressure loss (bar) pressure loss (bar) flow rate [l/h] 15 flow rate [l/h]

Thermix Split System Compact block made of brass with integrated primary bypass, mixer with adjustable bypass and integral servomotor, pump with 2 m cable, compact heat exchanger with insulation, immersion sleeve for flow circuit sensor, air bleeding plugs, wall mounting, EPP insulation, KFE valve for air bleeding,? male connection possibility for expansion vessel, connection set for installation beneath the wall-mounted boiler consisting of two T-pieces and two flexible stainless steel connections. Thermix Split System Number of plates Pump Art. No../each 20 Pump Grundfos Alfa2 15-60 A 27408.21 907,00 30 Pump Grundfos Alfa2 15-60 A 27408.31 998,00 20 Pump Wilo HU 15/4-2-3 27408.20 WI 700,00 30 Pump Wilo HU 15/4-2-3 27408.30 WI 791,00 Maximum capacities Heat exchanger max. V * capacity at 5K capacity at 10K Number of plates (l/h) (kw) (kw) 20 1040,00 5,93 11,86 30 1100,00 6,27 12,54 * Maximum flow rate in low-temperature circuit Flow diagrams flow rate/pressure loss diagram Thermix Split System, primary side (heat exchanger) Pressure loss [bar] Pressure loss [bar] Heat exchanger number of plates 20 Heat exchanger number of plates 30 flow rate (l/h) flow rate/pressure loss diagram Thermix Split System, secondary side NEU 20 plates 30 plates 16 flow rate (l/h)

Thermix safety group The safety module prevents an impermissible temperature rise in the low-temperature circuit in the event of faults involving the Thermix. If the temperature set at the temperature monitor is exceeded, the valve integrated in the inflow pipe prevents hot water from entering the heating circuit. Thermix accessories Boiler connection * not included in delivery Version: Art. No../each. safety group Thermix 27410.6 114,00 Technical data Temperature monitor: Version: Bimetal-based surface thermostat for securing to the pipe (up to 2 ) by means of clamping strap. Switchover function (changeover contact element), adjustable Adjustment range: 30 90 ºC Switching capacity: 16 (3) A, 250 V Protection mode: IP 30 Valve Design: Straight-way valve with thermally-actuated adjusting attachment, no-load make contact Voltage: 230 V AC/DC Protection mode: IP 43 Protection class :Totally insulated Flow volume limiter with display Installation set consisting of: 2 flow limiters, complete with screw connections, seals, and flexible connection 2-8 l/min, 3/4 female/male 27410.1 108,00 Extension set for installation next to the wall-mounted boiler Dual connection (Flow and return on the outside of the boiler) consisting of: 2 flexible corrugated pipes, length 50 cm and 80 cm, insulated with end-caps and union nuts for flat-sealing connection Single connection (Flow and return next to one another) consisting of: 2 flexible corrugated pipes, length 50 cm, insulated with end-caps and union nuts for flat-sealing connection 27410.2 42,10 27410.3 38,00 17

Systems for heat pumps Systems for heat pumps Heat pump groups Heat pump connection system for simple connection of the heating circuit or heating and hot water generation by way of buffer storage to the heat pump, with all the individual components required. The product: Your advantage: Heat pump distribution station for volume flows up to 3 m 3 /h for flow rates up to 3 m3/h for direct connection to the heat pump complete equipment for connection of a heating circuit Simple assembly thanks to rapid installation technology 1 2 1 2 Integration diagram for heating without buffer storage Integration diagram for heating and hot water generation by means of buffer storage 18

1 2 Heat pump connection groups DN 25 Pump group for heat pumps Pump group complete with or without circulating pump (EL 180 mm) in return line, with 2 m connection cable; two 3-way ball valves (on return side with manually adjustable gravity brake and sensor sleeve for sensor D=6 mm; two contact thermometers integrated in the ball valve handle (display range 0-120 ºC; one pump ball valve with Meibes flange; safety module with safety valve (response pressure 3 bar) integrated in inlet flow pipe length and pressure gauge (display range 0-4 bar); T-piece provided for installation of an expansion tank; EPP insulation. 1 Direct integration into the heating system Version: Art. No../each. 1 without pump 45510 EA 236,00 1 with Grundfos pump UPS 25-60 45510.2 332,00 1 with Grundfos pump RS 25/6 45510.3 328,00 2 Integration by way of buffer storage As above, but with side branch outlets 1 female for buffer storage connection 1 without pump 45510.4.EA 327,00 1 with Grundfos pump UPS 25-60 45510.4 423,00 1 with Wilo pump RS 25/6 45510.4 WI 419,00 1 1/4 on enquiry Technical data Heat pumps Flow diagrams Upper connection: Lower connections: Pump: Components of: Sealing material: Dimensions: Operational temperature: Up to 110 ºC Pressure stage: PN 6 Response pressure Safety valve: flow rate/pressure loss diagram and opening characteristics, depending on the overflow valve setting. 1 female Type 1: 1 1/2 male (flat-sealing) Type 2: 1 female See Article No. Steel, brass, EPP insulation PTFE (Teflon), asbestos-free fibre sealing, EPD, Approx. H 420 x W 250 x D 246 mm 3 bar flow rate/pressure loss diagram, heat pump connection group Pressure loss [bar] Pressure loss [bar] flow rate (l/h) flow rate (l/h) Brine manifold Brine manifold (steel, yellow chromated, adaptable) for connection of the brine circuits, including shut-off devices, consisting of distribution and collection pipe 1 1/2 male/female; brine circuit connection 1 male; shut-off ball valves 1 female crown nut x 1 female, including seals 1. Axial separation Length 3 circuits 125 435 45510.30 145,00 4 circuits 125 560 45510.31 184,00 6 circuits 125 810 45510.32 254,00 19

Systems for solar power Systems for solar power: Everything between collector and storage For rapid installation of solar power systems The products: Collector (solar panel) 1 Item No. Designation Page 1 iniflex-flexible connection 44 2 Screw fittings 46/47/64/65 3 Double corrugated pipe 45 4 Solar station 21-41 5 Expansion set 43 6 Powerfull station 43 7 Solar controller 42 3 2 Your advantage: All versions in rapid installation technology, tested and sealed Two-line solar stations in the same design as the pump groups 7 4 6 5 20

Solar stations S M L XL XXL Single-line solar station S 3/4 with flow display 1-13 l/min. Solar pump module as single-line design, complete with shut-off ball valve, including thermometer (not applicable with version with regulating system) and metallic gravity brakes integrated in the ball valve (manually adjustable), solar-compatible circulating pump, safety module incl. pressure gauge and KFE ball valve and safety valve already integrated, multi-function fitting with flow rate control and shut-off element, KFE ball valve, and connection for an expansion tank on the suction side of the pump, with flow volume display (combination display for propylene glycol mixture 40% and water). Version: Art. No../each. without pump 45719.2 EA 135,00 with Grundfos pump Solar 15-65 45719.2 204,00 with Grundfos pump Solar 15-85 - PWM Signal A 45719.4 422,00 with Wilo pump Star-ST 15/6 45719.2 WI 204,00 with Wilo pump Stratos-Para 15/1-7 - 0-10 V Signal A 45719.3 WI 415,00 with Wilo pump Stratos-Para 15/1-7 - PWM Signal A 45719.4 WI 415,00 Solar power As above but with integrated Basic control system Digital temperature difference controller for thermal solar power systems (1 collector field, 1 storage unit): Large multi-functional LCD display with pictograms, central button operation, 3 inputs for PT 1000 sensor, 1 electronic output 230 VAC, pump speed regulation, fault monitoring, manual operation possibility, collector protection function, return line cooling function; including 2 universal temperature sensor PT 1000, sensor = 6 mm, length = 45 mm, cable length 2.5 m without pump 45719.21 EA 344,00 with Grundfos pump 15-65 45719.21 413,00 with Grundfos pump 15-85 - PWM Signal A 45719.41 631,00 with Wilo pump Star-ST 15/6 45719.21 WI 413,00 with Wilo pump Stratos-Para 15/1-7 A 45719.31 WI 624,00 with Wilo pump Stratos-Para 15/1-7 - PWM Signal A 45719.41 WI 624,00 The installation and assembly instructions from the pump manufacturers are to be respected. Technical data Collector surface area Up to12 sq.m. Connections Solar circuit 3/4 female for expansion vessel 3/4 male Max. permissible temperature +120 ºC, briefly up to +140 ºC (take note of max. permissible temperature of the pump) Max. permissible pressure 10 bar (take note of response pressure of safety valve) Gravity brakes: 1x 300 mm WC flow rate display Combination scale: Water 1.0... 13.0 l/min Propylene glycol (40%) 0.8... 10.3 l/min Thermometer Display range 20... 150 ºC Pressure gauge Display range 0... 10 bar Safety valve Response pressure 6 bar Dimensions H 385 mm (with control system: 430 mm) W 200 mm,d 185 mm Axial separation 100 mm Pressure loss [bar] Flow diagram flow rate/pressure loss diagram, Solar station S flow rate (l/h) 21

Two-line solar station S M L XL XXL Two-line solar station S 3/4 with flow volume display 1-13 l/min Solar pump module as two-line design, complete with shut-off ball valves, including thermometer and metallic gravity brakes (manually adjustable) integrated in the ball valve, solar-compatible circulating pump, safety module incl. pressure gauge and KFE ball valve, and safety valve already integrated, multi-function fitting with flow rate control and shut-off element respectively, KFE ball valve and connection for an expansion vessel on the suction side of the pump with flow volume display (combination display for propylene glycol mixture 40% and water), optionally with permanent air bleeder installed in flow line for constant air separation. As above, but with integrated BASIC solar regulation system Digital temperature differential controller for thermal solar power systems (1 collector field, 1 storage unit): Large multifunctional LCD display with pictograms, central button operation, 3 inputs for PT 1000 sensors, 1 electronic output 230 VAC, pump speed regulation, fault monitoring, manual operation possibility, collector protection function, return line cooling function; including 2 universal temperature sensors PT 1000, sensor = 6 mm, length = 45 mm, cable length 2.5 m. Technical data Collector surface area Connections Up to12 sq.m. Solar circuit 3/4 female for expansion vessel 3/4 male Max. permissible temperature +120 ºC, briefly up to +140 ºC (take note of max. permissible temperature of the pump) Max. permissible pressure 10 bar Gravity brakes: flow rate display Combination scale: 2x 300 mm WC Water 1.0... 13.0 l/min Propylene glycol (40%) 0.8... 10.3 l/min Thermometer Display range 20... 150 ºC Pressure gauge Display range 0... 10 bar Safety valve Response pressure 6 bar Dimensions H 385 mm x W 300 mm x D 185 mm Axial separation 100 mm Flow diagram flow rate/pressure loss diagram, two-line solar station type S* Pressure loss [bar] flow rate (l/h) 22

Two-line solar station S M L XL XXL Version: Art. No../each. without regulating system, without permanent air bleeder without pump 45705.2 EA 179,00 with Grundfos pump Solar 15-65 45705.2 248,00 with Grundfos pump 15-85 - PWM Signal A 45705.4 466,00 with Wilo pump Star-ST 15/6 45705.2 WI 248,00 with Wilo pump Stratos-Para 15/1-7 - 0-10 Signal A 45705.3 WI 459,00 with Wilo pump Stratos-Para 15/1-7 - PWM Signal A 45705.4 WI 459,00 with permanent air bleeder without pump 45705.6 EA 208,00 with Grundfos pump Solar 15-65 45705.6 277,00 with Grundfos pump Solar 15-85 - PWM Signal A 45705.8 495,00 with Wilo pump Star-ST 15/6 45705.6 WI 277,00 with Wilo pump Stratos-Para 15/1-7 A 45705.7 WI 488,00 with Wilo pump Stratos-Para 15/1-7 - PWM Signal A 45705.8 WI 488,00 Solar power with regulating system, without permanent air bleeder without pump 45705.21 EA 388,00 with Grundfos pump Solar 15-65 45705.21 457,00 with Grundfos pump Solar 15-85 - PWM Signal A 45705.41 675,00 with Grundfos pump Star-ST 15/6 45705.21 WI 457,00 with Grundfos pump Stratos-Para 15/1-7 A 45705.31 WI 668,00 with Grundfos pump Stratos-Para 15/1-7 - PWM Signal A 45705.41 WI 668,00 with permanent air bleeder without pump 45705.61 EA 418,00 mit Grundfos-Pumpe Solar 15-65 45705.61 487,00 with Wilo pump Solar 15-85 - PWM Signal A 45705.81 705,00 with Wilo pump Star-ST 15/6 45705.61 WI 487,00 with Wilo pump Stratos-Para 15/1-7 A 45705.71 WI 698,00 with Wilo pump Stratos-Para 15/1-7 - PWM Signal A 45705.81 WI 698,00 The installation and assembly instructions from the pump manufacturers are to be respected. 23

Single-line solar station S M L XL XXL Single-line solar station M 3/4 with flow volume display 1-13 l/min Complete with or without circulating pump (DN 25, EL 180 mm) with 2 m connection cable, 3-way ball valve with manually-adjustable metallic gravity brake, one contact thermometer (display range 20-150 ºC) integrated in the ball valve handle, safety group with TÜV-tested (Technical Monitoring Association) safety valve (response pressure 6 bar), pressure gauge (display range 0-10 bar), two scavenging, filling, and emptying ball valves, including hose nozzle and cap, securing material for wall mounting, two-part EPP insulation, multi-function device with flow rate regulation and shut-off element, KFE ball valve, and connection for an expansion vessel on the suction side of the pump, with flow volume display (combination display for propylene glycol mixture 40% and water). Technical data Collector surface area: Up to12 sq.m. Upper connection: 3/4 female Lower connection: 3/4 male Pump: See Article number Components made of: Brass, EPP insulation (I = 0.04 W / (m*k)) Sealing material: PTFE (Teflon), asbestos-free fibre sealing, EPDM Dimensions: Approx. H 500 x W 190 x D 170 mm Temperature display: 20 to 150 ºC Operating temperature. Up to 110 ºC, briefly 130 ºC (take note of max. permissible temperature of the pump) flow rate display Combination scale: Water 1.0... 13.0 l/min Propylene glycol (40%) 0.8... 10.3 l/min Connection for expansion vessel: 3/4 male Flow diagram flow rate/pressure loss diagram, single-line solar station type M* Pressure loss [bar] flow rate (l/h) 24

Single-line solar station S M L XL XXL Version: Art. No../each. without pump 45718.0 EA 161,00 with Grundfos pump Solar 25-65 45718.1 257,00 with Grundfos pump Solar 25-85 - PWM Signal A 45718.185 480,00 with Wilo pump Star-ST 25/6 45718.1 WI 257,00 with Wilo pump Stratos-Para 25/1-7- 0-10 Signal A 45718.131 WI 458,00 with Wilo pump Stratos-Para 25/1-7 - PWM Signal A 45718.132 WI 460,00 Accessories: Solar controller Designation Art.-No../each. Solar power BASIC: Digital temperature differential controller for thermal solar power systems (1 collector field, 1 storage container), large multi-functional LCD display with pictograms, central button control, 3 inputs for PT 1000 sensor, 1 electronic output, 230 VAC, pump speed regulation, fault monitoring, manual operation possibility, collector protection function, return line cooling function, including 2 universal temperature sensors PT 1000, sensor = 6 mm, length = 45 mm, cable length 2.5 m. for pump control via block modulation 45111.5 196,00 for pump control via PWM or 0-10 V signal 45111.5 210,00 ENERGY: As for BASIC solar controller, but with pipe collector and reheating function, as well as possibility for yield measurement in combination with suitable flow detector (option). for pump control via block modulation 45111.7 265,00 for pump control via PWM or 0-10 V signal 45111.7 H 281,00 MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection for pump control via block modulation 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Other types on enquiry. 45111.72 142,00 25

Two-line solar station S M L XL XXL Two-line solar station M 3/4 with flow volume display 1-13 l/min Complete with or without circulating pump (DN 25, EL 180 mm) with 2 m connection cable, two 3-way ball valves with manually-adjustable metallic gravity brake, two contact thermometers (display range 20-150 ºC) integrated in the ball valve handle, safety group with TÜV-tested (Technical Monitoring Association) safety valve (response pressure 6 bar), pressure gauge (display range 0-10 bar), scavenging, filling, and emptying ball valve, including hose nozzle and cap, securing material for wall mounting, two-part EPP insulation, multi-function device with flow rate regulation and shut-off element, KFE ball valve, and connection for an expansion vessel on the suction side of the pump, with flow volume display (combination display for propylene glycol mixture 40% and water). Technical data Collector surface area: Up to12 sq.m. Upper connection: 3/4 female Lower connection: 3/4 male Pump: See Article number Components made of: Brass, EPP insulation (I = 0.04 W / (m*k)), glass Sealing material: PTFE (Teflon), asbestos-free fibre sealing, EPDM Dimensions: Approx. H 500 x W 315 x D 246 mm Temperature display: 20 to 150 ºC Operating temperature: Up to 110 ºC, briefly 130 ºC (take note of max. permissible temperature of the pump) flow rate display: Combination scale: Water 1.0... 13.0 l/min Propylene glycol (40%) 0.8... 10.3 l/min Connection for expansion vessel: 3/4 male Flow diagram flow rate/pressure loss diagram, single-line solar station type M* Pressure loss [bar] with permanent air bleeder without permanent air bleeder flow rate (l/h) 26

Two-line solar station S M L XL XXL Version: Art. No../each. without pump 45704.0 EA 204,00 with Grundfos pump Solar 25-65 45704.1 300,00 with Grundfos pump 25-85 - PWM Signal A 45704.185 523,00 with Wilo pump Star-ST 25/6 45704.1 WI 300,00 with Wilo pump Stratos-Para 25/1-7- 0-10 Signal A 45704.131 WI 501,00 with Wilo pump Stratos-Para 25/1-7 - PWM Signal A 45704.132 WI 503,00 As above, but with permanent air bleeder fitted in the flow line for constant air separation without pump 45704.5 EA 234,00 with Grundfos pump Solar 25-65 45704.5 330,00 with Grundfos pump Solar 25-85 - PWM Signal A 45704.585 553,00 with Wilo pump Star-ST 25/6 45704.5 WI 330,00 with Wilo pump Stratos-Para 25/1-7 0-10 Signal A 45704.531 WI 531,00 mit Wilo-Pumpe Stratos-Para 25/1-7 - PWM Signal A 45704.532 WI 533,00 Solar power The installation and assembly instructions from the pump manufacturers are to be respected. Accessories: Solar controller Designation Art.-No../each. BASIC: Digital temperature differential controller for thermal solar power systems (1 collector field, 1 storage container), large multi-functional LCD display with pictograms, central button control, 3 inputs for PT 1000 sensor, 1 electronic output, 230 VAC, pump speed regulation, fault monitoring, manual operation possibility, collector protection function, return line cooling function, including 2 universal temperature sensors PT 1000, sensor = 6 mm, length = 45 mm, cable length 2.5 m. for pump control via block modulation 45111.5 196,00 for pump control via PWM or 0-10 V signal 45111.5 HE 210,00 ENERGY: As for BASIC solar controller, but with pipe collector and reheating function, as well as possibility for yield measurement in combination with suitable flow detector (option). for pump control via block modulation 45111.7 265,00 for pump control via PWM or 0-10 V signal 45111.7 HE 281,00 MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread? male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Other types on enquiry 45111.72 142,00 27

S M L XL XXL Solar split system M For connection to the storage loading circuit Complete with or without circulating pump (DN 25, EL 180 mm) with 2 m connection cable; compact heat exchanger; two 3-way ball valves with manually-adjustable metallic gravity brake, two contact thermometers (display range 20-150 ºC) integrated in the ball valve handle, safety group with TÜV-tested (Technical Monitoring Association) safety valve (response pressure 6 bar), pressure gauge (display range 0-10 bar), connection set for an expansion vessel with expansion vessel service coupling, two scavenging, filling, and emptying ball valves, including hose nozzle and cap; rapid air bleeder; securing material for wall mounting; two-part EPP insulation; screw connection for the secondary circuit (optionally 1 male or 1 female). * not included in delivery Technical data Collector surface area Up to12 sq.m. Split system type 45741.16 WI 45741.20 WI 45741.26 WI Heat exchanger number of plates 16 20 26 Max. capacity with secondary 20 ºC/50 ºC 3.7 kw 5 kw 7 kw (60 ºC/44 ºC with primary) Max. capacity with secondary 35 ºC/53 ºC 2.9 kw 4 kw 5.5 kw (60 ºC/50 ºC with primary) Maximum pressure 6 bar Operational temperature Up to 110 ºC, briefly 130 ºC (take note of permissible temperature of pump) Dimensions (with insulation) Approx. H 500 x W 315 x D 246 mm Insulation material EPP Axial separation 125 mm Upper connection 3/4 female Lower connection 1 female Medium Propylene glycol 40% (primary) Water (secondary) Connection for expansion vessel 3/4 male Flow diagrams flow rate/pressure loss diagram Solar split system, primary side* Solar split system, primary side* Heat exchanger plate number 16 Pressure loss [bar] Heat exchanger plate number 20 Heat exchanger plate number 26 Pressure loss [bar] Heat exchanger plate number 16 Heat exchanger plate number 20 Heat exchanger plate number 26 flow rate (l/h) flow rate (l/h) 28

S M L XL XXL Solar split system M Version: Art. No../each. with 16 plates without pump 45741.16 EA 594,00 with Grundfos pump Solar 25-65 45741.16 GF 690,00 with Grundfos pump Solar 25-85 - PWM Signal A 45741.16 GF 85 913,00 with Wilo pump Star-ST 25/6 45741.16 WI 690,00 with Wilo pump Stratos-Para 25/1-7 - 0-10 Signal A 45741.16 WI 31 891,00 with Wilo pump Stratos-Para 25/1-7 - PWM Signal A 45741.16 WI 32 893,00 with 20 plates without pump 45741.20 EA 619,00 with Grundfos pump Solar 25-65 45741.20 GF 708,00 with Grundfos pump Solar 25-85 - PWM Signal A 45741.20 GF 85 931,00 with Wilo pump Star-ST 25/6 45741.20 WI 708,00 with Wilo pump Stratos-Para 25/1-7 - 0-10 Signal A 45741.20 WI 31 909,00 with Wilo pump Stratos-Para 25/1-7 - PWM Signal A 45741.20 WI 32 911,00 Solar power with 26 plates without pump 45741.26 EA 667,00 with Grundfos-pump Solar 25-65 45741.26 GF 763,00 with Grundfos-pump Solar 25-85 - PWM Signal A 45741.26 GF 85 986,00 with Wilo-pump Star-ST 25/6 45741.26 WI 763,00 with Wilo-pump Stratos-Para 25/1-7 - 0-10 Signal A 45741.26 WI 31 964,00 with Wilo-pump Stratos-Para 25/1-7 - PWM Signal A 45741.26 WI 32 966,00 The installation and assembly instructions from the pump manufacturers are to be respected. Accessories: Solar controller Type: Ref.-No./each. MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection for pump control via block modulation 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Other types on enquiry 29 45111.72 142,00

Specialvariant S M L XL XXL Solar Station M For two separate collector panels (east/ west) Two return lines: Complete with or without circulating pumps (DN25, EL 180mm) with 2m connection cable; 3-way ball valves with manually positioned, metallic gravity brakes; contact thermometers integrated in the ball valve handle (display range 20-150 C); safety module with TÜV-tested safety valve (response pressure 6 bar), pressure gauge (display range 0-10 bar), flushing, filling and draining ball valve incl. hose nozzle and cap; multi-function fitting with flow control and shut-off device, KFE tap and connection for an expansion vessel on the pump intake side, with flow indicator (combined display for propylene glycol mixture 40% and water); connection set for the return lines One flow line: complete with 3-way ball valve with manually positioned, metallic gravity brake; contact thermometers integrated in the ball valve handle (display range 20-150 C); permanent vent; fixing materials for wall mounting; EPP insulation. For two storage units Design as above; however, with one connection set downstream of the return lines Technical Data Collector area: 2 x 12 m2 Top connection: 3/4" female Bottom connection: 3/4" female Pump: See Article number Components made from... brass, EPP insulation, glass Sealing materials: PTFE (Teflon), asbestos-free fibre seal, EPDM Dimensions: approx. H 500 x B 190 x D 170 mm each line Temperature display: 20-150 C Use temperature: up to 110 C short-term 130 C (please note max. permissible temperature of the pump) Volumetric flow indicator Combination scale: Water: 1.0...13.0 l/min Propylene glycol (40%): 0.8...10.3 l/min Connection for expansion vessel: 3/4" male Flow diagrams flow rate/pressure loss diagram east/ west-station Pressure loss [bar] Druckverlust (bar) without permanent air bleeder flow rate (l/h) Volumenstrom (l/h) *Flow resistance with brine solution (propylene glycol 40%) 30

Specialvariant S M L XL XXL Type: Art. No../each for two separate collector panels without pump 45721.1 EA 445,00 with Grundfos pump Solar 25-65 45721.1 637, 00 with Wilo pump Start ST 25/6 45721.1 WI 637,00 for two separate storage loading circuits (store charging circuits) without pump 45721.2 EA 445,00 with Grundfos pump Solar 25-65 45721.2 637, 00 with Wilo pump Start ST 25/6 45721.2 WI 637,00 Note and observe the pump manufacturers' installation and assembly instructions. Accessories: Solar controller Solaranlagen Type: Art. No../each MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection for pump control via block modulation 45111.9 377, 00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Other types on enquiry 45111.72 142,00 31

Solar station M/L S M L XL XXL Solar station M/L (SolaVentec) with valve technology with flow volume display optionally with 1-13 l/min or 8-30 l/min Gravity circulation 100% excluded, complete with circulating pump (DN 25, EL 180 mm) with 2 m connection cable; Solaventec valve block as shut-off and regulating element with manual adjustment possibility; thermostatic regulating valve; two contact thermometers (display range 20-150 ºC), safety group with TÜV-tested (Technical Monitoring Association) safety valve (identification letter H, response pressure 6 bar), pressure gauge (display range 0-10 bar), two scavenging, filling, and emptying ball valves, including hose nozzle and cap, connection possibility for an expansion vessel; multi-function device with flow rate regulation and shut-off element, KFE ball valve, and connection for an expansion vessel on the suction side of the pump, with flow volume display (combination display for propylene glycol mixture 40% and water). Optionally with permanent air bleeder mounted in the flow pipe for constant separation of air. Illustration with permanent air bleeder Flow diagrams Collector surface area Up to 22 sq.m. Connections 3/4 female Connection for expansion vessel3/4 male Pump (DN 25, L = 180 mm) See Article number SolaVentec drive 220 V, 50/60 Hz, 3 Watt flow rate limiter Two scale increments Dimensions H/W/D in mm: 560/320/150 Operating temperature 120 ºC, briefly 130 ºC (take note of maximum permissible temperature of the pump) Safety group (response pressure) 6 bar Display range, thermometer 20 to 150 ºC Display range, pressure gauge 0 to 10 bar flow rate display with combination scale: Water 1.0... 13.0 l/min Propylene glycol (40%) 0.8... 10.3 l/min flow rate display with combination scale: Water 6.9... 25.8 l/min Propylene glycol (40%) 7.4... 27.1 l/min Flow diagrams flow rate/pressure loss diagram, SolaVentec with flow volume display 1-13 l/min flow rate/pressure loss diagram, SolaVentec with flow volume display 8-30 l/min with permanent air bleeder Pressure loss [bar] with permanent air bleeder Pressure loss [bar] without permanent air bleeder without permanent air bleeder flow rate (l/h) flow rate (l/h) 32

Solar station M/L S M L XL XXL Version: Art. No../each. Solar station M/L Flow volume indicator 1-13 l/min. with Grundfos pump Solar 25-65 45750.7 346,00 with Grundfos pump 25-85 - PWM Signal A 45750.785 569,00 with Wilo pump Star-ST 25/6 45750.7 WI 346,00 with Wilo pump Stratos-Para 25/1-7 A 45750.731 WI 547,00 with Wilo pump Stratos-Para 25/1-7 - PWM Signal A 45750.732 WI 549,00 Flow volume indicator 8-30 l/min. with Grundfos pump Solar 25-65 45750.6 346,00 with Grundfos pump Solar 25-85 - PWM Signal A 45750.685 569,00 with Wilo pump Star-ST 25/6 45750.6 WI 346,00 with Wilo pump Stratos-Para 25/1-7 A 45750.631 WI 547,00 with Wilo pump Stratos-Para 25/1-7 -PWM Signal A 45750.632 WI 549,00 As above, but with permanent air bleeder installed in flow pipe Flow volume indicator 1-13 l/min. with Grundfos pump Solar 25-65 45750.9 376,00 with Grundfos pump Solar 25-85 - PWM Signal A 45750.985 599,00 with Wilo pump Star-ST 25/6 45750.9 WI 376,00 with Wilo pump Stratos-Para 25/1-7 A 45750.931 WI 577,00 with Wilo pump Stratos-Para 25/1-7 - PWM Signal A 45750.932 WI 579,00 Solar power Flow volume indicator 8-30 l/min. with Grundfos pump Solar 25-65 45750.8 376,00 with Grundfos pump 25-85 - PWM Signal A 45750.885 599,00 with Wilo pump Star-ST 25/6 45750.8 WI 376,00 with Wilo pump Stratos-Para 25/1-7 A 45750.831 WI 577,00 with Wilo pump Stratos-Para 25/1-7 - PWM Signal A 45750.832 WI 579,00 Accessories: Solar controller BASIC: Digital temperature differential controller for thermal solar power systems (1 collector field, 1 storage container), large multi-functional LCD display with pictograms, central button control, 3 inputs for PT 1000 sensor, 1 electronic output, 230 VAC, pump speed regulation, fault monitoring, manual operation possibility, collector protection function, return line cooling function, including 2 universal temperature sensors PT 1000, sensor = 6 mm, length = 45 mm, cable length 2.5 m. for pump control via block modulation for pump control via PWM or 0-10 V signal 45111.5 196,00 45111.5 210,00 ENERGY: As for BASIC solar controller, but with pipe collector and reheating function, as well as possibility for yield measurement in combination with suitable flow detector (option). for pump control via block modulation for pump control via PWM or 0-10 V signal 45111.7 265,00 45111.7 281,00 MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection. for pump control via block modulation 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Other types on enquiry. 33 45111.72 139,00 45111.73 156,00

Two-line solar station S M L XL XXL Two-line solar station 1 with flow volume display 10-40 l/min. Complete with or without circulating pump (DN 25, EL 180 mm) with 2 m connection cable; two 3-way ball valves with gravity brakes, manually adjustable in the return pipe; two contact thermometers (display range 20-150 ºC) integrated in the ball valve handle; safety group with TÜV-tested (Technical Monitoring Association) safety valve (identification letter H, response pressure 6 bar), pressure gauge (display range 0-10 bar), two scavenging, filling, and emptying ball valves, including hose nozzle and cap; connection possibility for an expansion vessel; flow volume indicator for high-flow and low-flow systems, securing material for wall mounting; two-part EPP insulation. Optionally with permanent air bleeder installed in flow pipe for permanent separation of air. Technical data Collector surface area Up to50 sq.m. Upper connection 1 female Lower connection 1 male Pump See Article number Axial separation 125 mm Components made of Brass, EPP insulation (l = 0.04 W / (m*k)), glass Sealing materials PTFE (Teflon), asbestos-free fibre sealing, EPDM Dimensions Approx. H 420 x W 250 x D 246 mm Temperature display 20 to 150 ºC Operating temperature Up to 110 ºC, briefly 130 ºC (take note of maximum permissible temperature of the pump) male connection for expansion vessel 3/4 Flow diagram flow rate/pressure loss diagram Two-line solar station L with permanent air bleeder Pressure loss [bar] without permanent air bleeder flow rate (l/h) 34

Two-line solar station S M L XL XXL Version: Art. No../each. Solar station L with Flow volume indicator 10-40 l/min without pump 45704.100 EA 276,00 with Grundfos pump Solar 25-120 45704.120 1020,00 with Wilo pump Top-S 25/10 45704.100 WI 726,00 with Wilo pump Stratos Para 25/1-11 A 45704.120 WI 998,00 As before, but with permanent air bleeder installed in the flow pipe for permanent separation of air Flow volume indicator 10-40 l/min. without pump 45722.100 EA 307,00 with Grundfos pump Solar 25-120 45722.120 1051,00 with Wilo pump Top-S 25/10 45722.100 WI 757,00 with Wilo pump Stratos Para 25/1-11 A 45722.120 WI 1029,00 Solar power The installation and assembly instructions from the pump manufacturers are to be respected. Accessories: Solar controller Designation: Art. No../each. BASIC: Digital temperature differential controller for thermal solar power systems (1 collector field, 1 storage container), large multi-functional LCD display with pictograms, central button control, 3 inputs for PT 1000 sensor, 1 electronic output, 230 VAC, pump speed regulation, fault monitoring, manual operation possibility, collector protection function, return line cooling function, including 2 universal temperature sensors PT 1000, sensor = 6 mm, length = 45 mm, cable length 2.5 m. for pump control via block modulation 45111.5 196,00 for pump control via PWM or 0-10 V signal 45111.5 HE 210,00 ENERGY: As for BASIC solar controller, but with pipe collector and reheating function, as well as possibility for yield measurement in combination with suitable flow detector (option). for pump control via block modulation 45111.7 265,00 for pump control via PWM or 0-10 V signal 45111.7 HE 281,00 MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection. for pump control via block modulation 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Rated flow Qn 1.5 45111.72 142,00 Rated flow Qn 2.5 45111.73 156,00 Other types on enquiry. 35

Solar station S M L XL XXL Solar XL Heat exchanger solar station Complete with two circulating pumps (EL 130 mm) with 2 m connection cable; two flow volume limiters; soldered stainless steel plate heat exchangers, including block insulation; two air bleeding possibilities; one primary sensor support; four shut-off ball valves; four scavenging, filling and emptying ball valves, including hose nozzle; all mounted on base plate and tested; stainless steel corrugated pipe connections with insulation; with metal cladding. Technical data Collector surfaceup to 22 sq.m., Art. No. 45140.7 and 45140.71 Collector surfaceup to 30 sq.m., Art. No. 45140.8 and 45140.81 Connection 1 female Pump See Article number Axial separation 65 mm Components made of Brass, EPP insulation (l = 0.04 W / (m*k)), glass Sealing materials PTFE (Teflon), asbestos-free fibre sealing, EPDM Dimensions Approx. H 810 x W 600 x D 210 mm Operating temperature Up to 110 ºC, briefly 120 ºC (take note of maximum permissible temperature of the pump) male connection for expansion vessel 1/2 female Flow diagrams flow rate/pressure loss diagram Solar station XL, primary side Flow volume display 4 15 l/min Pressure loss [bar] Flow volume display 10 40 l/min flow rate (l/h) flow rate/pressure loss diagram Solar station XL, secondary side Flow volume display 4 15 l/min Pressure loss [bar] Flow volume display 10 40 l/min flow rate (l/h) 36

Solar station S M L XL XXL Version: Art. No../each. Solar station XL with Flow volume indicator 4-15 l/min. primary with Grundfos pump Solar 15-65 secondary with Grundfos pump UPS 15-60 45140.7 1450,00 primär mit Wilo-Pumpe Stratos Para 15/1-7 A secondary with Grundfos pump UPS 15-60 45140.71 1660,00 Flow volume indicator 10-40 l/min.. primary side pump Wilo Star ST 20/11 Solar secondary with Grundfos pump UPS 15-60 C 45140.8 1520,00 primary with Wilo pump Stratos Para 15/1-11,5 A secondary with Grundfos pump UPS 15-60 45140.81 1710,00 Accessories: Safety module for Solar XL, consisting of: T-piece with screw terminal connections 3 x 22 mm Small safety manifold, connection possibility 3/4 male (flat-sealing) for an expansion vessel. Solar power Primary side (collector circuit): Safety valve 1/2 x 3/4, response pressure 6 bar (primary) Pressure gauge, display range 0...10 bar (primary) Safety module, primary 66325.11 XL 40,50 Secondary side: Safety valve 1/2 x 3/4, response pressure 3 bar (secondary) Pressure gauge, display range 0...4 bar (secondary) Safety module, secondary 66325.12 XL 37,70 Accessories: Solar controller Version: Art. No../each. MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection for pump control via block modulation 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Rated flow Qn 1.5 45111.72 142,00 Rated flow Qn 2.5 45111.73 156,00 Other types on enquiry. 37

Solar Station S M L XL XXL Solar XL - special variants Design as Solar Station XL; however without flow limiter on the secondary side and with integrated safety groups and primary changeover valve e.g. for two separate collector panels (east/west) or one collector circuit cooling system (primary) Type: Art. No../each Solar Station XL with flow limiter 10-40 l/min. (primary) primary side with Grundfos pump UPS 25-80 secondary side with Grundfos pump UPS 25-80 45140.20 2.000,00 as above; however, with secondary changeover valve e.g. for two separate storage loading circuits or pool heater flow limiter 10-40 l/min. (primary) primary side with Grundfos pump UPS 25-80 secondary side with Grundfos pump UPS 25-80 45140.21 2.100,00 as above; however, with primary and secondary changeover valve e.g. for two separate collector panels (east/west) and two separate storage loading circuits flow limiter 10-40 l/min. (primary) primary side with Grundfos pump UPS 25-80 secondary side with Grundfos pump UPS 25-80 45140.22 2.200,00 38

Solar Station S M L XL XXL System example for two separate collector panels and two separate storage loading circuits Solar power Accessories: Solar controller Version: Art. No../each. MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection for pump control via block modulation 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Rated flow Qn 1.5 45111.72 142,00 Rated flow Qn 2.5 45111.73 156,00 Other types on enquiry. 39

Solar station S M L XL XXL Solar XXL Heat exchanger solar station, complete with two circulating pumps, one copper-soldered stainless steel plate heat exchanger, including block insulation, two flow rate limiters, two safety valves and pressure gauges, one air separator (secondary), one strainer (secondary), shut-off devices with thermometer handles (flow side, secondary with backflow inhibitor), mounting frame made of aluminium profiles with height-adjustable feet. Technical data Collector surface Up to 95 sq.m., Art. No. 45142.1 Collector surface Up to 150 sq.m., Art. No. 45142.2 and 45142.21 Dimensions H/W/D in mm 820 x 890 x 290 Connections 1 1/4 female Axial separation in mm 103 Safety valves 3/4 x 1 (Response pressure primary: 6 bar; secondary 3 bar) Max. permissible operating temperature: 110 ºC Flow diagrams flow rate/pressure loss diagram Solar station XXL, secondary side Heat exchanger plate number 30 Pressure loss [bar] Heat exchanger plate number 60 flow rate (l/h) flow rate/pressure loss diagram Solar station XXL, primary side Heat exchanger plate number 30 Pressure loss [bar] Heat exchanger plate number 60 flow rate (l/h) 40 34

Solar station S M L XL XXL Version: Art. No../each. Solar station XXL with Flow volume indicator 10-40 l/min./heat exchanger, 30 plates Primary and secondary with Wilo Top S 30/10 pump 45142.1 4120,00 Flow volume indicator 20-70 l/min./heat exchanger, 60 plates Primary and secondary with Wilo Star 30/1-12 pump 45142.2 5380,00 Primary and secondary with Stratos Para 30/1-12 pump A 45142.21 5530,00 Accessories: Solar controller Solar power Version: Art. No../each. MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection for pump control via block modulation 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread 3/4 male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Rated flow Qn 1.5 45111.72 142,00 Rated flow Qn 2.5 45111.73 156,00 Other types on enquiry. 41

Components for solar power systems Solar controller Art. No../each. BASIC: Digital temperature differential controller for thermal solar power systems (1 collector field, 1 storage container), large multi-functional LCD display with pictograms, central button control, 3 inputs for PT 1000 sensor, 1 electronic output, 230 VAC, pump speed regulation, fault monitoring, manual operation possibility, collector protection function, return line cooling function, including 2 universal temperature sensors PT 1000, sensor = 6 mm, length = 45 mm, cable length 2.5 m. for pump control via block modulation 45111.5 196,00 for pump control via PWM or 0-10 V signal 45111.5 HE 210,00 ENERGY: As for BASIC solar controller, but with pipe collector and reheating function, as well as possibility for yield measurement in combination with suitable flow detector (option). for pump control via block modulation 45111.7 265,00 for pump control via PWM or 0-10 V signal 45111.7 HE 281,00 MAXIMAL Universal controller for solar power systems with up to two collector fields and two storage units; four relay outputs (electronic relays), low-voltage relay for reheating, 8 measurement inputs for temperature, flow rate meter and solar sensor. Easy operation, large at-a-glance display with background lighting. Functions: Temperature differential regulation; pump speed regulation of pumps; low-voltage relays for reheating function; storage and collector safety function; heating support; parallel loading of storage elements; storage priority with pendulum loading; low-flow function for layer storage; ebus for visualisation and data logger. Further functions: Actuation of an external heat exchanger; actuation of an external bypass; free allocation of the sensors with one or two storage sensors; second collector sensor for east/south orientation; thermostat and temperature comparison function; solar yield; collector monitoring; frost protection function; anti-legionella function; pump blocking protection 45111.9 377,00 Flow indicator for ENERGY / MAXIMAL solar controller Installation length 110 mm, connection thread? male, operating temperature max. +90 ºC. Rated flow Qn 1.5, pulse sequence 1 pulse/litre, incl. 1 temperature sensor PT1000 Rated flow Qn 1.5 45111.72 142,00 Rated flow Qn 2.5 45111.73 156,00 42

Components for solar power systems Version: Art. No../each. Powerfüll, mobile filling and flushing centre Transportable, compact, and completely assembled unit for filling (air bleeding, flushing, and separating) of closed systems, such as solar power systems, floor and wall heating systems, and drinking water networks. Delivery capacity: 5-50 l/min. Operating pressure: 0.8-5.5 bar Solar manual filling pump 45100.9 685,00 Piston pump with manual filling and topping up or increasing the pressure of the solar power system, 1 m filling hose, pressure build-up max. 6 bar. Solar power 45100.2 71,80 Solar extension set With angled bracket for direct flexible connection to the safety group of the solar station or to an additional screw connection in the solar return pipe. Consisting of: Stainless steel corrugated pipe 2 x 3/4 female union nut x 500 mm; two seals 3/4 ; one service coupling, Solar, 3/4 male/female for separation of the expansion vessel without emptying the system; angled wall bracket, including securing material. 66326.13 38,40 Expansion Vessel Solar Service coupling Quick-action safety coupling as per DIN 4751 Sheet 2/93, allows for rapid replacement of the expansion vessel, 3/4 male x 3/4 female. 69080.3 13,90 43

Components for solar power systems flex-fix-connections Solar In fixed lengths of Inoflex stainless steel corrugated pipe, can be bent in several planes, corrugated pipe ends machined at the plant to be flat-sealing. Scope of supply with two captive brass nuts and seals and high-temperature resistant rubber insulation, resistant up to 150 ºC, briefly up to 175 ºC, standard length 1000 mm. Dimension Insulation thickness Art. No../each DN 12 x 1/2 female (nut) 13 mm 4121.M04M04.100 16,30 DN 16 x 3/4 female (nut) 19 mm 4161.M06M06.100 21,40 DN 20 x 1 female (nut) 19 mm 4201.M08M08.100 24,00 All lengths in mm. Other lengths and dimensions on enquiry. Inoflex stainless steel corrugated pipe in single-ply insulation in lengths up to 25 m, high-temperature resistant rubber insulation, resistant up to 150 ºC, briefly up to 175 ºC, insulation thickness 19 mm. Dimension: Length without cable /m with cable /m DN 16 Meterware bis 25 m 46123 ES 15,10 46123 ESK 15,90 DN 20 Meterware bis 25 m 46122 ES 16,80 46122 ESK 17, 60 Dimension: Length without cable /Stk. with cable /Stk. DN 16 10 m 46123 ES 10 131,00 46123 ESK 10 138,00 DN 16 15 m 46123 ES 15 190,00 46123 ESK 15 201,00 DN 16 20 m 46123 ES 20 251,00 46123 ESK 20 267, 00 DN 16 25 m 46123 ES 25 310,00 46123 ESK 25 327, 00 DN 20 10 m 46122 ES 10 146,00 46122 ESK 10 153,00 DN 20 15 m 46122 ES 15 213,00 46122 ESK 15 223,00 DN 20 20 m 46122 ES 20 280,00 46122 ESK 20 295,00 DN 20 25 m 46122 ES 25 348,00 46122 ESK 25 367, 00 As above, but with protective film The film wrapping serves as protection against mechanical stress. Insulation thickness 14 mm Dimension: Length without cable./m with cable./m DN 16 Meterware bis 25 m 46123 ECS 15,40 46123 ECSK 16,20 DN 20 Meterware bis 25 m 46122 ECS 17,10 46122 ECSK 17, 90 Dimension: Length without cable./each. with cable./each. DN 16 10 m 46123 ECS 10 133,00 46123 ECSK 10 140,00 DN 16 15 m 46123 ECS 15 193,00 46123 ECSK 15 204,00 DN 16 20 m 46123 ECS 20 256,00 46123 ECSK 20 272,00 DN 16 25 m 46123 ECS 25 315,00 46123 ECSK 25 332,00 DN 20 10 m 46122 ECS 10 149,00 46122 ECSK 10 156,00 DN 20 15 m 46122 ECS 15 217, 00 46122 ECSK 15 227,00 DN 20 20 m 46122 ECS 20 286,00 46122 ECSK 20 301,00 DN 20 25 m 46122 ECS 25 354,00 46122 ECSK 25 373,00 44

Components for solar power systems Inoflex-Edelstahlwellrohr in Doppelstrangisolierung Inoflex stainless steel corrugated pipe with double-ply insulation Inoflex stainless steel corrugated pipe in lengths up to max. 25 m, high-temperature resistant rubber insulation, resistant up to 150 ºC, briefly up to 175 ºC, insulation thickness 14 mm with cable guide. Version without cable./m with cable./m DN 12 46125 TS 25,90 46125 TSK 26,90 DN 16 46123 TS 27,00 46123 TSK 27,80 DN 20 46122 TS 31,70 46122 TSK 32,50 DN 25 46121 TS 40,00 46121 TSK 40,80 Version Length without cable./m with cable./m DN 12 10 m 46125 TS 10 226,00 46125 TSK 10 233,00 DN 12 15 m 46125 TS 15 335,00 46125 TSK 15 346,00 DN 12 20 m 46125 TS 20 445,00 46125 TSK 20 460,00 DN 12 25 m 46125 TS 25 554,00 46125 TSK 25 572,00 Solar power DN 16 10 m 46123 TS 10 240,00 46123 TSK 10 247, 00 DN 16 15 m 46123 TS 15 357, 00 46123 TSK 15 368,00 DN 16 20 m 46123 TS 20 474,00 46123 TSK 20 490,00 DN 16 25 m 46123 TS 25 591,00 46123 TSK 25 608,00 DN 20 10 m 46122 TS 10 288,00 46122 TSK 10 295,00 DN 20 15 m 46122 TS 15 429,00 46122 TSK 15 439,00 DN 20 20 m 46122 TS 20 569,00 46122 TSK 20 584,00 DN 20 25 m 46122 TS 25 710,00 46122 TSK 25 729,00 DN 25 10 m 46121 TS 10 363,00 46121 TSK 10 370,00 DN 25 15 m 46121 TS 15 540,00 46121 TSK 15 550,00 DN 25 20 m 46121 TS 20 717,00 46121 TSK 20 732,00 DN 25 25 m 46121 TS 25 895,00 46121 TSK 25 914,00 Inoflex stainless steel corrugated pipe with double-ply insulation with protective film Inoflex stainless steel corrugated pipe in lengths up to max. 25 m, high-temperature resistant rubber insulation, resistant up to 175 ºC (briefly), insulation thickness 14 mm with cable guide. The film wrapping serves as protection against mechanical stress. Separable into two individual plies. Version without cable./m with cable./m DN 12 46125 CS 25,70 46125 CSK 26,50 DN 16 46123 CS 27,20 46123 CSK 28,00 DN 20 46122 CS 32,00 46122 CSK 32,80 Version Length without cable./m with cable./m DN 12 10 m 46125 CS 10 233,00 46125 CSK 10 240,00 DN 12 15 m 46125 CS 15 345,00 46125 CSK 15 356,00 DN 12 20 m 46125 CS 20 459,00 46125 CSK 20 473,00 DN 12 25 m 46125 CS 25 571,00 46125 CSK 25 590,00 DN 16 10 m 46123 CS 10 247, 00 46123 CSK 10 254,00 DN 16 15 m 46123 CS 15 369,00 46123 CSK 15 379,00 DN 16 20 m 46123 CS 20 490,00 46123 CSK 20 504,00 DN 16 25 m 46123 CS 25 610,00 46123 CSK 25 628,00 DN 20 10 m 46122 CS 10 298,00 46122 CSK 10 306,00 DN 20 15 m 46122 CS 15 444,00 46122 CSK 15 454,00 DN 20 20 m 46122 CS 20 588,00 46122 CSK 20 603,00 DN 20 25 m 46122 CS 25 734,00 46122 CSK 25 750,00 45

Components for solar power systems FixLock Rapid sealing quick-action screw connection for Inoflex corrugated pipe. Operating temperature up to 200 ºC. Operating pressure depending on pipe dimension Betriebstemperatur bis 200 C, Betriebsdruck in Abhängigkeit der Wellrohrdimension FixLock connection set Screw connection set for connecting Inoflex stainless steel corrugated pipe, consisting of: 4 union nuts, 2 double nipples with form sealing. Version: Art. No../each. DN 12 46105.1 FL 16,00 DN 16 46104.1 FL 15,80 DN 20 46103.1 FL 21,40 DN 25 46102.1 FL 33,00 FixLock screw connection set Union nut, spacer ring, counter-screw element with form seal female or male. Femal thread Outer thread DN 12 3/8 46115 FL 46105 FL 6,30 DN 16 1/2 46114 FL 46104 FL 7,40 DN 20 3/4 46113 FL 46103 FL 8,40 DN 25 1 46112 FL 46102 FL 11,30 FixLock screw fitting set with transition to clamp ring screw fitting (KLV) Union nut, spacer ring, counter-screw element with form sealing DN 16 22 KLV G 29611.11 FL 8,90 DN 20 22 KLV G 29611.12 FL 9,90 Reduzierringe siehe Seite S. 81 FixLock screw fitting set with transition on self-sealing connection female Union nut, spacer ring, counter-screw element with form sealing, outer thread with PTFE DN 16 3/4 AG 43.66124 FLP 9,00 DN 20 1 AG 43.66125 FLP 9,90 FixLock connection set with branch T-piece for tool-free corrugated pipe connection with female thread transition (B) to freely selectable pipe system. Scope of supply includes two union nuts and two spacer rings. A B DN 12 1/2 FL x 3/8 female x 1/2 FL 90250.042 FL 12,20 DN 16 3/4 FL x 1/2 female x 3/4 FL 90250.043 FL 15,70 DN 20 1 FL x 3/4 female x 1 FL 90250.931 FL 19,20 As above, but with female thread transition (C). C DN 12 1/2 FL x 1/2 FL x 3/8 IG 90250.045 FL 12,20 DN 16 3/4 FL x 3/4 FL x 1/2 IG 90250.044 FL 15,70 DN 20 1 FL x 1 FL x 3/4 IG 90250.932 FL 19,20 Note: Due to necessary manufacturing tolerances, FixLock can only be used in conjunction with Inoflex stainless steel corrugated pipe (guarantees will otherwise be excluded). Oval clamp set Set bestehend aus einer Ovallschelle zur Fixierung des Inoflex-Edelstahlwellrohres in Doppelstrangisolierung DN16 und DN20 inkl. Stockschraube M8 x 80 und Dübel. 69410.7 6,20 46

Components for solar power systems Flat-sealing screw connections Connection set Screw connection set for connecting Inoflex stainless steel corrugated pipe, consisting of: 2 double nipples; 4 union nuts, 4 seals, and 4 spacer rings. Version: Art. No../each DN 12 46105.1 11,20 DN 16 46104.1 15,80 DN 20 46103.1 21,40 DN 25 46105.1 33,00 Screw connection set consisting of: Union nut, one spacer ring, counter screw element, female or male, sealing. female thread Outer thread./each DN 12 3/8 46115 46105 5,40 DN 16 1/2 46114 46104 7,20 DN 20 3/4 46113 46103 8,20 DN 25 1 46113 46103 8,20 Solar power Supplement set, 10 spacer rings and 10 seals for corrugated pipe connections Art. No../each DN 12 46205 12,50 DN 16 46204 17, 70 DN 20 46203 19,80 DN 25 46202 22,90 Flange impact production set Tool set for problem-free production of flanges on flexible Inoflex stainless steel corrugated pipes. The set contains in each case: 1 impact tool, 1 flanging bar, and 1 set of clamping chucks. Version: Art. No../each. DN 12 46312 126,00 DN 16 46316 126,00 DN 20 46320 126,00 DN 25 46325 126,00 Also available as individual parts on enquiry. 47

Systems for domestic water heating Systems for domestic water heating Hygienic, economical domestic water heating without any problems with legionella* The product: for all systems with heating buffer reservoir (e.g. solar power systems, heat pump, solid-fuel boiler, block-type thermal power stations) Your advantage: High hot water output at constant temperature up to 39 l/min High economy thanks to low RP-temperature Insensitive to limescale, even with very hard water Space-saving installation No drinking water reservoir necessary Example of installation: Cold water Circulation *According to DVGW Worksheet W 551, Para. 5.2.2. Hot water 48

Fresh water station, electronically controlled LogoFresh fresh water station Basic station consisting of: Base plate with connection rails, white cover (H/W/D 800 x 600 x 210), heat exchanger (with large thermal length) made of copper-soldered stainless steel plates, Grundfos UPS 15/60 circulating pump (on the heating side), air bleeding possibilities on the heating side, backflow inhibitor for the heating circuit pump, electronic fresh water controller (proportional) for constant hot water temperature control as a function of the hot water temperature set and tapping capacity by modulation of the heating circuit pump. Including 3 shut-off ball valves 1 female. Version: Art. No../each 10270.2 1.680,00 LogoFresh fresh water station with domestic water circulation module As for the station described above, but with additional integrated circulation pump set consisting of: Circulating pump UP 15-30, backflow inhibitor, piping and screw connection parts mounted in the station and connected to the control system. Including 3 shut-off ball valves 1 female. 10270.21 1.830,00 Domestic water heating Performance data Heating of cold water ºK 40 40 40 40 40 40 flow temperature primary ºC 55 60 65 70 75 80 return temperature primary ºC 29 26 23 21 20 19 Tapping quantity drinking water l/min 17 22 27 31 35 39 Drinking water capacity kw 46 62 75 86 97 108 flow rate primary l/h 1550 1550 1550 1550 1550 1550 Pressure loss, bar, primary 0,23 0,23 0,23 0,23 0,23 0,23 Residual delivery height primary, bar 0,15 0,15 0,15 0,15 0,15 0,15 Pressure loss, bar, secondary 0,15 0,25 0,38 0,50 0,64 0,80 Technical data Connections, heating and cold water mains: 1 (female or male respectively) Operating pressure, heating: 3 bar Operating pressure, cold water mains: 6 bar Max. permissible flow temp.: 110 ºC Weight: 15 kg Protection class, controller: IP 54 Supply voltage: 230 VAC/50 Hz Dimensions (width x height x depth) in mm: 600 x 800 x 210 49

Fresh water station, thermostatically controlled Fresh water station, thermostatically controlled consisting of: Base plate with connection rails, white metal cover, heat exchanger made of copper-soldered stainless steel plates, Grundfos UPS 15-60 circulating pump, regulating valve with thermostat head and remote sensor, regulating valve in bypass stretch, backflow inhibitor, flow switch, strainer with KFE ball valve, terminal box for electrical connection, air bleeding possibilities, 3 shut-off ball valves. Version: Art. No../each 2-25 l/min. without circulation 10271.21 1.110,00 Fresh water station, thermostatically controlled with domestic water circulation module As for the station described above, but with additional integrated circulation pump set, with domestic water circulation pump Wilo Z15. 2-25 l/min with circulation 10271.2 1.300,00 As above, but with additional integrated digital week time switch 2-25 l/min with circulation and time switch 10271.2 DW 1.480,00 Technical data Hot water capacity: 2-15 l/min, 10-25 l/min Dimensions H/W/D in mm 800 x 500 x 210 Connections 3/4 female or male respectively (cold water supply) Thermostat control range 20... 70 ºC Max. operating pressure, heating 3 bar Max. operating pressure, cold water mains 6 bar Max. permissible temperatures 110 ºC (provide for scald protection if appropriate) 50

Cascade connection If a more substantial flow rate is required which exceeds the capacity of one single fresh water station, there is the possibility of a cascade connection. In this case, the overflow valve is adjusted in such a way that the downstream station takes up operation as soon as a desired drinking water flow volume is reached. Overflow valve: DN 25 for cascade connection, Setting range 100-500 mbar Fresh water station accessories Version: Art. No../each 69072.9 84,00 Cascade connection of installation Domestic hot Domestic cold Domestic water heating Fresh water charging station For direct charging of a drinking water storage tank without pump control, consisting of: Baseplate with connection rail, white metal cover, copper-soldered stainless steel heat transfer plates, Grundfos UP 15-30 circulating pump, changeover valve with thermostatic head and remote surface sensor for hot water temperature control, pump shut-off valve with integrated backflow preventer and thermometer integrated in the handle, contact thermometer, two KFE ball valves, manual bleeder. The safety equipment, integration of the controls in the charging pump and provision of the primary flow and differential pressure must be provided on site by the customer. Technical Data Hot water output (35K) :bs 45kW (18 l/min) Dimensions H/B/D in mm :50 x 390 x 165 mm Connections :3/4 male (flat sealing) Thermostat control range : 40... 70 C Max. perm. differential pressure across the changeover valve :1.2 bar max. perm. operating pressure: 6 bar Art. No../each 10271.6 747,00 47 51

Systems for large heating installations Complete system for heating installations up to 2300 kw The product: Complete system consisting of: Manifold for 2 or 3 heating circuits combinable as necessary 90 elbow connection in confined spaces Pre-assembled pump groups, DN 25 to DN 65 with large selection of pumps For delivery volumes up to 100 m3/h and capacity up to 2300 kw Heating maintenance unit = air separator, Dirt trap, hydraulic diverter, (optional) Magnetite separator (optional) Your advantage: Short installation times and rapid replacement of manifold systems Easy cost calculation Easy planning = Less risk and more yield Victaulic connections Victaulic is a well-known connection system. It sets itself apart through its fast and easy installation. During installation the pipes are laid end to end with butt joints and the Victaulic coupling is placed around the pipes so that they sit in the beads of the pipe ends. 52

System components For use of large-scale manifold pump groups 6 Item Name Page 1 External transition 6 2 Heating maintenance unit 4 3 Internal transition 4 4 Reducing set for V groups only 8 5 Pump groups 7/58/60/61 6 External transition set 1 7 Manifold 5 5 Reducing set for use with V groups only For use of large-scale manifold pump groups 1 2 3 4 Large heating installation 7 53

Heating maintenance unit, hydraulic diverter Heating maintenance unit (with or without hydraulic diverter) Housing: welded round tank with coupling made from seamless steel pipe incl. Victaulic groove Cleaning opening in the bottom with a 1 drain valve. The four 3/4 sockets in the bottom are for optional installation of magnetite separators, which are closed off with plugs on delivery. An automatic float bleeder, a flushing ball valve and an immersion sleeve for holding a temperature sensor are located in the top part. The heating maintenance unit is held by an adjustable-height base. Incl. EPS insulation. Max permissible pressure rating: PN 6 (PN 10 on request.) max. permissible temperature: 110 C Heating maintenance unit with hydraulic diverter Output Delivery rate Outer Pipe Art. No../each 135 kw 6 m 3 /h 60,3 66374.50 814,00 280 kw 12 m 3 /h 88,9 66374.80 847,00 700 kw 30 m 3 /h 114,3 66374.100 1.000,00 1150 kw 50 m 3 /h 168,3 66374.150 1.720,00 2300 kw 100 m 3 /h 219,1 66374.200 1.740,00 Heating maintenance unit without hydraulic diverter 135 kw 6 m 3 /h 60,3 66374.52 814,00 280 kw 12 m 3 /h 88,9 66374.81 847, 00 700 kw 30 m 3 /h 114,3 66374.101 1.000,00 1150 kw 50 m 3 /h 168,3 66374.151 1.720,00 2300 kw 100 m 3 /h 219,1 66374.204 1.740,00 Magnetite separator (1 set) Type Art. No.. for heating maintenance unit up to 280 kw 60364.500 264,00 for heating maintenance unit from 700 kw 60364.501 338,00 D Threaded transition fittings (system - internal) Heating maintenance unit (HZW) to the manifold (V), angle (W), heat generator (WEZ) Victaulic-Victaulic with insulation, 1 pair HZW V, W, WEZ Nom - pipe - pipe - Axial separation Art. No.. DN 50 60,3 114,3 225 66258.632 165,00 DN 80 88,9 114,3 225 66258.634 141,00 DN 100 114,3 168,3 340 66258.831 301,00 DN 150 168,3 168,3 450 66258.81 157, 00 DN 200 219,1 219,1 450 66258.91 191,00 54

Large-scale manifold 250 mm pipe separation = 1135 mm Manifold blocks (2-circuit or 3-circuit module) The manifolds consist of two chambers arranged on top of each other with thermal separation of the flow and return. The boiler circuit can be connected on the left or the right. All connections are prepared for use of Victaulic clips. The top outlets for connection of the heating circuits are in nominal size DN 50. All manifolds are delivered painted, pressure (leak) tested, completely insulated and with two adjustable height base feet. Further, 2 Victaulic couplings and 2 end caps with 1/2" bore and insulations for the Victaulic clips are also supplied. The bores are closed off with blank covers. Alternatively, a KFE tap can be screwed in for draining. The manifold system consists of elements for 2 or 3 heating circuits, which can be combined with each other in any way necessary, depending on the axial separation. Max permissible pressure rating: PN 10 max. permissible temperature: 110 C AD AA 2-circuit module incl. 2 Victaulic clips with blank covers and insulation Output Delivery rate Outer Axial Art. No../each 280 kw 12 m 3 /h 114,3 225 66457.0 430,00 700 kw 30 m 3 /h 168,3 340 66457.2 600,00 1150 kw 50 m 3 /h 168,3 450 66457.4 1.110,00 2300 kw 100 m 3 /h 219,1 450 66457.6 1.210,00 pipe separation = 1635 mm AD 250 mm AA 3-circuit module incl. 2 Victaulic clips with blank covers and insulation 280 kw 12 m 3 /h 114,3 225 66457.1 680,00 700 kw 30 m 3 /h 168,3 340 66457.3 930,00 1150 kw 50 m 3 /h 168,3 450 66457.5 1.460,00 2300 kw 100 m 3 /h 219,1 450 66457.7 1.680,00 Output data at ΔT = 20 K, max. temperature 110 C. arge heating Angle connection - 1 pair incl. 2 Victaulic clips and insulation 280 kw 12 m 3 /h 114,3 225 66457.100 380,00 700 kw 30 m 3 /h 168,3 340 66457.300 510,00 1150 kw 50 m 3 /h 168,3 450 66457.500 680,00 2300 kw 100 m 3 /h 219,1 450 66457.700 760,00 Nameplates for manifold insulation one pair (1x red, 1x blue), incl. anchor plugs and labelling strips. 66170 13,10 Threaded transition fittings (system - internal) Heating maintenance unit (HZW) to the manifold (V), angle (W), heat generator (WEZ) Victaulic-Victaulic with insulation, 1 pair HZW V, W, WEZ Nom - pipe - pipe - Axial separation Art.-No.. DN 50 60, 3 114,3 225 66258.632 165,00 DN 80 88, 9 114,3 225 66258.634 414,00 DN 100 114, 3 168,3 340 66258.831 301,00 DN 150 168,3 168,3 450 66258.81 157,00 DN 200 219,1 219,1 450 66258.91 191,00 55

Threaded transition fittings Threaded transition fittings (system - external) to the heat generator (WEZ) Victaulic-Victaulic, 1 pair Manifold/heating maintenance unit WEZ Nom - pipe - nom - pipe - Art.-No.. DN 50 60,3 DN 40 48,3 66259.23 72,60 DN 50 60,3 DN 50 60,3 66259.31 32,70 DN 80 88,9 DN 65 76,1 66259.532 93,20 DN 80 88,9 DN 80 88,9 66259.51 29,90 DN 100 114,3 DN 100 114,3 66259.61 44,50 DN 150 168,3 DN 125 141,3 66259.832 212,00 DN 150 168,3 DN 150 168,3 66259.81 97,60 DN 200 219,1 DN 200 219,1 66259.91 156,00 Victaulic-welded end, 1 pair DN 50 60,3 DN 40 48,3 66259.371 79,20 DN 50 60,3 DN 50 60,3 66259.372 36,30 DN 80 88,9 DN 65 76,1 66259.572 102,00 DN 80 88,9 DN 80 88,9 66259.573 46,80 DN 100 114,3 DN 100 114,3 66259.675 62,90 DN 150 168,3 DN 125 139,7 66259.872 316,00 DN 150 168,3 DN 150 168,3 66259.873 129,00 DN 200 219,1 DN 200 219,1 66259.972 203,00 Victaulic-flange PN 6, 1 pair DN 50 60,3 DN 40 Flange 66259.391 106,00 DN 50 60,3 DN 50 Flange 66259.392 66,60 DN 80 88,9 DN 65 Flange 66259.592 136,00 DN 80 88,9 DN 80 Flange 66259.593 89,50 DN 100 114,3 DN 100 Flange 66259.695 120,00 DN 150 168,3 DN 125 Flange 66259.892 411,00 DN 150 168,3 DN 150 Flange 66259.893 250,00 DN 200 219,1 DN 200 Flange 66259.992 346,00 Victaulic-welded end with insulation, 1 pair Manifold WEZ Nom - pipe - Nom - pipe - axial separation Art.-No.. DN 100 114,3 DN 40 48,3 225 66258.671 170,00 DN 100 114,3 DN 50 60,3 225 66258.672 172,00 DN 100 114,3 DN 65 76,1 225 66258.673 191,00 DN 100 114,3 DN 80 88,9 225 66258.674 145,00 DN 150 168,3 DN 100 114,3 340/450 66258.871 319,00 DN 150 168,3 DN 125 139,7 340/450 66258.872 363,00 DN 150 168,3 DN 150 168,3 340/450 66258.873 185,00 DN 200 219,1 DN 200 219,1 450 66258.972 235,00 Victaulic-flange PN 6 with insulation, 1 pair Manifold WEZ Nom - pipe - axial separation Art.-No.. DN 100 114,3 DN 40 Flange 225 66258.691 196,00 DN 100 114,3 DN 50 Flange 225 66258.692 202,00 DN 100 114,3 DN 65 Flange 225 66258.693 227, 00 DN 100 114,3 DN 80 Flange 225 66258.694 200,00 DN 150 168,3 DN 100 Flange 340/450 66258.891 375, 00 DN 150 168,3 DN 125 Flange 340/450 66258.892 476, 00 DN 150 168,3 DN 150 Flange 340/450 66258.893 308, 00 DN 200 219,1 DN 200 Flange 450 66258.992 378, 00 Further transitions available on request! 56

Großverteiler-Pumpengruppen UK DN 25-32 ca.470 Manifold pump group V-UK (unmixed circuit for manifold configuration) Complete with or without circulation pump (EL 180 mm) with 2m connection cable; two 3-way ball valves (return side with manually positioned gravity brake); two contact thermometers integrated in the ball valve handle (display range 0-120 C); one pump ball valve with Meibes flange; EPS insulation; axial separation from 175 mm freely selectable; bottom outlet 1 1/2" male flat sealing, top outlet female according to pump dimension; ca.175 Type: Art.-No../each DN 25 (1 ) without pump 66713 EA 169,00 with Grundfos pump UPS 25-40 66713 259,00 with Grundfos pump Alpha2 25-60 A 66713.30 466,00 with Wilo pump Star RS 25/4 66713 WI 255,00 mit Wilo-Pumpe Star E 25/1-6 66713.65 WI 363,00 with Wilo pump Stratos Para 25/1-7* A 66713.31 WI 446,00 DN 32 (1 1/4 ) without pump 66714 EA 232,00 with Grundfos pump UPS 32-40 66714 329,00 mit Grundfos-Pumpe Alpha2 32-60 A 66714.30 539,00 with Wilo pump Star RS 30/4 66714 WI 321,00 mit Wilo-Pumpe Star E 30/1-6 66714.65 WI 427, 00 with Wilo pump Stratos Para 30/1-7* A 66714.31 WI 519,00 Technical Data DN 25 32 Top connection: G 1 female G 1 1/4 female Bottom connection: G 1 1/2 male (flat-sealing) Pump: See Article number Axial separation: from 175 mm Components made from: Steel, brass, EPS insulation Dimensions: approx. H 420 x B 250 x D 246 mm Sealing materials: PTFE, asbestos-free fibre seal, EPDM Temperature display: 0 to 120 C Use temperature: up to 110 C Operating pressure: PN 6 kvs value: 9.7 11 Note: Side change from flow to return possible, retrofit overflow set *incl. additional option: Control signal 0-10 V Durchflussdiagramm arge heating installation Threaded transition fitting for the Meibes large-scale manifold 2 complete threaded couplings 1 1/2 female x 50 female (60.3 mm Victaulic) 66305.50 57,50 57

Large-scale manifold pump groups MK DN 25-32 ca.470 Manifold pump group V-MK (mixer circuit for manifolds configuration) Complete with or without circulation pump (EL 180 mm) with 2m connection cable; two 3-way ball valves (return side with manually positioned gravity brake); two contact thermometers integrated in the ball valve handle (display range 0-120 C); one 3-way T mixer incl. steplessly adjustable bypass; EPS insulation; axial separation from 175 mm (larger than 250 mm available for additional price); bottom outlet 1 1/2" male flat sealing, top outlet female according to pump dimension; Type: Art.-No../each ca.175 DN 25 (1 ) without pump 66733 EA 242,00 with Grundfos pump UPS 25-40 66733 332,00 with Grundfos pump Alpha2 25-60 A 66733.30 539,00 mit Wilo-Pumpe Star RS 25/4 66733 WI 328,00 with Wilo pump Star E 25/1-5 66733.65 WI 436,00 with Wilo pump Star Para 25/1-7* A 66733.31 WI 519,00 DN 32 (1 1/4 ) without pump 66734 EA 312,00 with Grundfos pump UPS 32-40 66734 409,00 with Grundfos pump Alpha2 32-60 A 66734.30 619,00 with Wilo pump Star RS 30/4 66734 WI 401,00 with Wilo pump Star E 30/1-5 66734.65 WI 507, 00 with Wilo pump Stratos Para 30/1-7* A 66734.31 WI 599,00 *incl. additional option: Control signal 0-10 V Technical Data Durchflussdiagramm DN 25 32 Top connection: G 1 female G 1 1/4 female Bottom connection: G 1 1/2 male (flat-sealing) Pump: See Article number Axial separation: from 175 mm (other spacings available for additional price) Components made from: Steel, brass, EPS insulation Dimensions: approx. H 420 x B 250 x D 246 mm Sealing materials: PTFE, asbestos-free fibre seal, EPDM Temperature display: 0 to 120 C Use temperature: up to 110 C Operating pressure: PN 6 kvs value: 6.2 6.4 Note: In 2 types (flow left or flow right), Threaded transition fitting for the Meibes large-scale manifold 2 complete threaded couplings 1 1/2 female x 50 female (60.3 mm Victaulic) 66305.50 57,50 with Servomotor incl. mounting set with 2 m cable wired for direct mounting on the mixer of the MK groups, 230 V/50 Hz, running time 140 s., 90, 6 Nm with emergency manual operation and visible position indicator. 66341 121,00 58

Accessories for large-scale manifold - pump groups DN 25-32 low loss header Including air and sludge separator, axial separation 200 mm, for horizontal or vertical installation, with manual air bleeder and KFE ball valve, including hose nozzle and cap, immersion sleeve 3/8 female (female diameter 10 mm) for flow circuit temperature sensor, screw connection set 1 1/2 female (primary side), complete with block insulation; see page 35 for wall fastenings. Typ Capacity (bei T = 20K) Side connection Art. No../each for V-pump groups kw = 100 1 1/2 66394.1 311,00 magnetite separator set (2 units) For subsequent upgrading of Boiler Guard K and low loss header. Typ Art. No../each for low loss header (1 unit) 60364.503 66,40 manifold beams (axial separation 200 mm, for wall mounting) EPP insulation, with 2 or 3 connection pairs upwards (1 1/2 union nuts, flat-sealing), one connection pair downwards (2 union nut, flat-sealing with screw-in part 2 male x 1 1/2 female), axial separation 200 mm, for mounting on pump groups V-UK, V-MK; complete with the necessary screw fittings and connection parts, 2 emptying possibilities 1/2, for capacities up to 100 kw (at deltat = 20K). 2 heating circuits kw=100 66301.80 276,00 3 heating circuits kw=100 66301.81 368,00 arge heating installation Wall mounting Pair, with screws and dowels for manifold beams described above 66337.10 43,50 Threaded transition fitting for other manifold manufacturers 2 complete screw fitting sets 1 1/2 male x 1 1/2 female 66305.5 64,80 59

Large-scale manifold pump groups UK DN 40-65 Flansch-Pumpengruppe FL-UK (unmixed circuit for large-scale manifolds) Axial separation from 250 mm freely selectable, completely assembled, sealed and tested in the factory. Circulation pump, 3 shut-off valves, integrated gravity brake, 3 KFE ball valves, 2 thermometers, additional 1/2 connection options in the flow and return pipe, dirt trap, piping and connection parts, inkl. Victaulic transitions to the manifold. Max permissible pressure rating: PN 10 max. permissible temperature: 110 C 920 / 1000 (DN 65) Type: Art. No../each DN 40 (1 1/2 ) with insulation without pump 66537 EA 1.080,00 Grundfos pump MAGNA 40-100 F A 66537.11 2.210,00 Wilo pump Stratos 40/1-4 A 66537.14 WI 2.170,00 Wilo pump Stratos 40/1-8 A 66537.16 WI 2.240,00 Pump dimension 250 mm ca. 495 DN 50 (2 ) without pump 66538 EA 1.180,00 Grundfos pump MAGNA 50-100 F A 66538.17 2.960,00 Wilo pump Stratos 50/1-8 A 66538.12 WI 3.080,00 Pump dimension 280 m DN 65 (2 1/2 ) without pump 66539 EA 1.420,00 Grundfos pump MAGNA 65-120 F A 66539.11 4.700,00 Wilo pump Stratos 65/1-12 A 66539.12 WI 4.640,00 Pump dimension 340 mm If delivered without pump, the pump cut-out must be made in the insulation on site by the customer. Output overview/volumetric flow rates v = 0,5 m/s v = 1,0 m/s v = 1,5 m/s Size Nominal Q in kw Q in kw Q in kw V in l/h ΔT= ΔT= V in l/hδ ΔT= ΔT= V in l/h ΔT= ΔT= 10 K 20 K 10 K 20 K 10 K 20 K 1 1/2 DN 40 2469 28 57 4938 57 114 7407 84 169 2 DN 50 3969 46 92 7938 92 184 11907 136 271 2 1/2 DN 65 6689 77 155 13378 155 311 20006 228 456 v = flow velocity V = flow rate Q = output T = Temperature spread between flow and return UK = direct heating circuit MK = mixed heating circuit IMPORTANT: Table of guideline values The flow rate is determined by the pump! 60

Large-scale manifold pump groups MK DN 40-65 Flange - pump group FL-MK (mixer circuit for large-scale manifolds) Axial separation 250 mm, completely assembled, sealed and tested in the factory. Circulation pump, 2 shut-off valves, integrated gravity brake, 3-way flange mixer, 3 KFE ball valves, 2 thermometers, additional 1/2 connection options in the flow and return pipe, dirt trap, piping and connection parts, incl. Victaulic transitions. Max permissible pressure rating: PN 10 max. permissible temperature: 110 C 920 / 1000 (DN 65) Type: Art. No../each DN 40 (1 1/2 ) with insulation without pump 66547 EA 1.290,00 Grundfos pump MAGNA 40-100 F A 66547.11 2.410,00 Wilo pump Stratos 40/1-4 A 66547.14 WI 2.370,00 Wilo pump Stratos 40/1-8 A 66547.16 WI 2.440,00 Pump dimension 250 mm ca. 495 DN 50 (2 ) without pump 66548 EA 1.430,00 Grundfos pump MAGNA 50-100 F A 66548.17 3.220,00 Wilo pump Stratos 50/1-8 A 66548.12 WI 3.330,00 Pump dimension 280 mm DN 65 (2 1/2 ) without pump 66549 EA 1.730,00 Grundfos pump MAGNA 65-120 F A 66549.11 5.010,00 Wilo pump Stratos 65/1-12 A 66549.12 WI 4.950,00 Pump dimension 340 mm If delivered without pump, the pump cut-out must be made in the insulation on site by the customer. Threaded transition fittings to the heating circuit, 1 pair Victaulic - Victaulic Nenn - Connectio Art.-No. /Pair DN 40 48,3 66259.21 31,30 DN 50 60,3 66259.31 32,70 DN 65 76,1 66259.41 35,40 Large arge heating heating installation Victaulic - male DN 40 1 1/2 AG 66259.26 49,50 DN 50 2 AG 66259.36 50,40 DN 65 2 1/2 AG 66259.46 56,40 Victaulic - welded end DN 40 48,3 66259.27 37, 90 DN 50 60,3 66259.37 40,80 DN 65 76,1 66259.47 45,00 Servomotor for FL-MK group DN 40/50, 230 V/50 Hz, 15 Nm not illustrated 66341.6 173,00 for FL-MK group DN 65, 230 V/50 Hz, 20 Nm, 66345.7 291,00 Running time 130 sec. for 90, with emergency manual operation. 61

Systems for flexible connections -stainless steel corrugated pipe and FixLock for heating, solar power, and cold water mains systems The product: Inoflex corrugated pipe The product: FixLock stainless steel corrugated pipe DN 12 to DN 40 with or without insulation in fixed lengths or by the metre tested and proofed quality product rapid screw connection for Inoflex corrugated pipe, with no need for tools operating temperature up to 200 ºC operating pressure: See corrugated pipe tested and proofed quality product Please refer t o the Technical Information for Inoflex corrugated pipe for technical data and installation guidelines. 62

Stainless steel corrugated pipe Length Length Basic length flex-fix connections Inoflex stainless steel material No. 1.4404 (1.4571) in fixed lengths, with and without insulation (insulation thickness 13 mm), can be bent in several planes. Corrugated pipe ends machined at the plant to be flat-sealing. Scope of supply includes two captive brass nuts (female=d) and two seals. Insulated corrugated pipes can be used up to max. 105 ºC (sustained temperature). Dimension Length Art. No../each/each Art. No../each without insulation with insulation DN 12/d=1/2 300 46154.30 8,80 46154.30 S 10,90 500 46154.50 10,70 46154.50 S 12,90 700 46154.70 12,30 46154.70 S 15,10 1000 46154.100 14,80 46154.100 S 18,30 DN 16/d=3/4 300 46153.30 10,40 46153.30 S 12,80 500 46153.50 12,40 46153.50 S 15,60 700 46153.70 14,50 46153.70 S 18,30 1000 46153.100 17,90 46153.100 S 22,40 DN 20/d=1 300 46152.30 11,10 46152.30 S 13,80 500 46152.50 13,70 46152.50 S 17, 00 700 46152.70 16,10 46152.70 S 20,00 1000 46152.100 20,10 46152.100 S 24,60 DN 25/d=1 1/4 300 46151.30 13,20 46151.30 S 15,40 500 46151.50 15,40 46151.50 S 18,70 700 46151.70 18,00 46151.70 S 22,10 1000 46151.100 22,10 46151.100 S 27, 10 DN 32/d=1 1/2 300 46150.30 14,10 46150.30 S 17,00 500 46150.50 17,10 46150.50 S 21,00 700 46150.70 20,50 46150.70 S 24,90 1000 46150.100 24,90 46150.100 S 30,30 All lengths in mm. Other lengths on request. - Stretch connection pipes made from stainless steel Supply in basic length (upset), can be extended up to 100%, and can be bent in several planes. Welded connections, on one side male conical, on the other side movable union nut, flat-sealing, 1x seal. See Technical Information for corrugated pipe for technical data and installation guidelines. female x male Dimension Basic length Art.No./each 3/8 x 3/8 DN 10 80 46001 10,30 105 46002 12,20 1/2 x 1/2 DN 15 70 46003 12,90 105 46004 14,60 180 46005 18,30 3/4 x 3/4 DN 20 70 46009 17, 50 105 46010 19,80 175 46011 26,90 1 x 1 DN 25 80 46012 22,80 105 46013 25,90 180 46014 35,10 1 1/4 x 1 1/4 DN 32 85 46015 36,00 105 46016 40,30 175 46017 50,20 1 1/2 x 1 1/2 DN 40 130 46018 48,10 205 46019 64,30 2 x 2 DN 50 120 46020 66,80 185 46021 86,50 reduced1/2 male x 3/4 female 3/4 x 1/2 DN 16 80 46006 14,60 105 46007 16,70 180 46008 21,10 All lengths and female diameters in mm. Fexible connection 63

B C Stainless steel corrugated pipe, length 6 m Stainless steel corrugated pipe Rolled materials and FixLock Version: Length Art.-No../each. Length Art.-No../each. DN 12 6 m 46125.1 S 56,20 80 m 46125 SW 80 666,00 DN 16 6 m 46123.1 S 67, 70 50 m 46123 SW 50 495,00 DN 20 6 m 46122.1 S 80,00 30 m 46122 SW 30 367, 00 DN 25 6 m 46121. 1 S 99,00 20 m 46121 SW 20 280,00 DN 32 6 m 46120.1 S 113,00 20 m 46120 SW 20 330,00 DN 40 6 m 46119. 1 S 142,00 20 m 46119 SW 20 406,00 FixLock Shaft sealing end Rapid screw connection for Inoflex corrugated pipe, heating, solar power, and cold water mains systems. Operating temperature up to 200 ºC, operating pressure as a function of the corrugated pipe dimension, DVGW-certified in the dimensions DN 12 to DN 20. FixLock screw connection set Union nut, spacer ring, counter-screw element with shaped seal, female or male. female thread Outer thread DN 12 3/8 46115 FL 46105 FL 6,20 DN 16 1/2 46114 FL 46104 FL 8,20 DN 20 3/4 46113 FL 46103 FL 9,40 DN 25 1 46112 FL 46102 FL 12,30 DN 32 1 1/4 46111 FL 46101 FL 18,20 FixLock screw fitting set with transition to clamp ring screw fitting (KLV) Union nut, spacer ring, counter-screw element with form sealing DN 16 22 KLV G 29611.11 FL 8,90 DN 20 22 KLV G 29611.12 FL 9,90 Reducer rings, see Page 81 FixLock screw fitting set with transition on self-sealing connection female Union nut, spacer ring, counter-screw element with form sealing, outer thread with PTFE DN 16 3/4 AG 43.66124 FLP 9,00 DN 20 1 AG 43.66125 FLP 9,90 FixLock connection set with branch T-piece for tool-free corrugated pipe connection with female thread transition (B) to any desired pipe system, scope of supply including two union nuts and two spacer rings. Version: Ref.-No./each. DN 12 1/2 FL x 3/8 female x 1/2 FL90250.042 FL 12,20 DN 16 3/4 FLx 1/2 female x 3/4 FL 90250.043 FL 15,70 DN 20 1 FLx 3/4 female x 1 FL 90250.931 FL 19,20 As above, but with female thread transition (C). DN 12 1/2 FL x 1/2 FL x 3/8 female 90250.045 FL 12,20 DN 16 3/4 FL x 3/4 FL x 1/2 female 90250.044 FL 15,70 DN 20 1 FL x 1 FL x 3/4 female 90250.932 FL 19,20 FixLock connection set Screw connection set for connecting Inoflex stainless steel pipe, consisting of: 4 union nuts, 4 spacer rings, 2 double nipples with shaped seal. DN 12 46105.1 FL 15,70 DN 16 46104.1 FL 19,10 DN 20 46103.1 FL 24,70 DN 25 46103.1 FL 24,70 Note: Owing to necessary manufacturing tolerances, FixLock can only be used in conjunction with Inoflex stainless steel corrugated pipe (guarantee is otherwise excluded) 64

Stainless steel corrugated pipe Accessories Flat-sealing screw connections Flange swaging set Tool set for problem-free flange creation on flexible Inoflex stainless steel corrugated pipes. Each set contains: One swage tool, one crimping bar, and one set of clamping chucks. Version: Art. No../each. DN 12 46312 126,00 DN 16 46316 126,00 DN 20 46320 126,00 DN 25 46325 126,00 DN 32 46332 84,40 DN 40 46340 84,40 Also available as individual items on enquiry. Verschraubungsset consisting of: Union nut, one spacer ring, counter-screw element female or male, seal Heating and solar power female male./each. Heating female male./each. DN 12 46115 46105 5,50 DN 25 46112 46102 11,30 DN 16 46114 46104 7,40 DN 32 46111 46101 15,90 DN 20 46113 46103 8,40 DN 40 46110 46100 26,70 Supplement set, 10 spacer rings and 10 sets for corrugated pipe connections Heating and solar power./each. Heating./each. DN 12 46205 12,50 DN 25 46202 22,90 DN 16 46204 17,70 DN 32 46201 25,00 DN 20 46203 19,80 DN 40 46200 29,20 Connection fittings Version: pc/box Art.-No../pce Counter-screw element female (flat-sealing) in MS 58 DN 12 1/2 M x 3/8 F 10 67550 3,20 DN 16 3/4 M x 1/2 F 10 90652.1 4,30 DN 20 1 M x 3/4 F 10 90652.2 4,70 DN 25 1 1/4 M x 1 F 5 90652.3 7,10 DN 32 1 1/2 M x 1 1/4 F 3 90652.4 10,20 DN 40 2 M x 1 1/2 F 2 90652.6 16,80 Nuts in MS 58 DN 12 1/2 F 10 43.511 MS 1,05 DN 16 3/4 F 10 43.520 MS 1,25 DN 20 1 F 10 43.530 MS 1,55 DN 25 1 1/4 F 5 43.540 MS 1,95 DN 32 1 1/2 F 3 43.550 MS 3,20 DN 40 2 F 2 43.560 MS 6,60 Soldered transition (flat-sealing) in MS 58 DN 16 3/4 x 18 mm 5 62418.02 2,90 DN 20 1 x 22 mm 5 62422.02 3,50 DN 32 1 1/2 x 28 mm 5 62428.02 8,20 DN 32 1 1/2 x 35 mm 5 62435.02 8,20 Version: pc/box Art.-No../pce Counter-screw element female (flat-sealing) in MS 58 DN 12 1/2 M x 3/8 M 10 90251.8 3,20 DN 16 3/4 M x 1/2 M 10 90651.1 4,30 DN 20 1 M x 3/4 M 10 90651.2 4,70 DN 25 1 1/4 M x 1 M 5 90651.3 7,10 DN 32 1 1/2 M x 1 1/4 M 3 90651.4 30,00 DN 40 2 M x 1 1/2 M 2 90651.6 33,00 Double nipple (flat-sealing) in MS 58 DN 12 1/2 M 10 43.66123.1 2,05 DN 16 3/4 M 10 43.66124 D 3,00 DN 20 1 M 10 43.66125 D 4, 80 DN 25 1 1/4 M 5 43.66126 D 8,00 DN 32 1 1/2 M 3 43.66133 D 10,90 Soldered transition (flat-sealing) in MS 58 DN 121/2 x 22 mm 5 G 29611.10 OP 5,20 DN 16 3/4 x 22 mm 5 G 29611.11 OP 5,20 DN 20 1 x 22 mm 5 G 29611.12 M 6,50 Fexible connection (For reduction from 22 mm to 18 and 15 see page 75) male = Outer thread, M female = female thread, F 65

Systems for flexible connections Armoured hoses for heating systems The product: Armoured hoses with galvanized braiding for heating systems (two-year guarantee) Armoured hoses with stainless steel braiding for heating systems and climate-control systems inside hose of EPDM (not diffusion-tight), resistant to water and glycol-based (max. 50%) anti-freeze products for temperatures up to +110 ºC Operating pressure up to 10 bar (from 11/2 up to 6 bar) Conditional manufacturing tolerances max. +/- 2.5% Follow assembly and installation instructions in accordance with the current technical information brochure. Your advantage: Flexible connections in tested quality Avoids stresses and noise Wide variety of connection variants -Wide variety of connection variants Note: In the event of possible condensation water forming (risk of corrosion), use armoured hoses with stainless steel jacketing (see p.48). Length female thread/outer thread female x male Length mm inside dia. mm Art. No../each 1/2 x 1/2 300 14 4325.0121.30 5,50 500 14 4325.0121.50 6,60 700 14 4325.0121.70 8, 00 1000 14 4325.0121.100 9,60 3/4 x 3/4 300 19 4325.0127.30 6,80 500 19 4325.0127.50 8,30 700 19 4325.0127.70 9,90 1000 19 4325.0127.100 11,70 1 x 1 300 25 4325.0134.30 10,60 500 25 4325.0134.50 12,70 700 25 4325.0134.70 14,90 1000 25 4325.0134.100 18,40 1 1/4 x 1 1/4 300 32 4325.0142.30 24,20 500 32 4325.0142.50 28, 50 700 32 4325.0142.70 32,90 1000 32 4325.0142.100 39,60 1 1/2 x 1 1/2 300 40 4325.0148.30 39,60 500 40 4325.0148.50 44,80 700 40 4325.0148.70 50,00 1000 40 4325.0148.100 57,70 2 x 2 500 50 4325.0160.50 62,30 700 50 4325.0160.70 69, 40 1000 50 4325.0160.100 80,00 Other lengths available on request. 66

Length Armoured hoses for heating systems with galvanized braiding female thread/female thread female x female Length mm inside mm Art.-No../each 1/2 x 1/2 300 14 4325.0221.30 5,50 500 14 4325.0221.50 6,60 700 14 4325.0221.70 8, 00 1000 14 4325.0221.100 9,60 3/4 x 3/4 300 19 4325.0227.30 6,80 500 19 4325.0227.50 8,30 700 19 4325.0227.70 9,90 1000 19 4325.0227.100 11,70 1 x 1 300 25 4325.0234.30 10,60 500 25 4325.0234.50 12,70 700 25 4325.0234.70 14,90 1000 25 4325.0234.100 18,40 1 1/4 x 1 1/4 300 32 4325.0242.30 24,20 500 32 4325.0242.50 28, 50 700 32 4325.0242.70 32,90 1000 32 4325.0242.100 39,60 1 1/2 x 1 1/2 300 40 4325.0248.30 39,60 500 40 4325.0248.50 44,80 700 40 4325.0248.70 50,00 1000 40 4325.0248.100 57,70 2 x 2 500 50 4325.0260.50 62,30 700 50 4325.0260.70 69, 40 1000 50 4325.0260.100 80,00 Other lengths available on request. Length Length Outer thread/bend male x bend Length mm inside mm Art. No./each 1/2 x 1/2 300 14 4327.0121.30 8,90 500 14 4327.0121.50 10,50 700 14 4327.0121.70 11,70 1000 14 4327.0121.100 13,60 3/4 x 3/4 300 19 4327.0127.30 10,40 500 19 4327.0127.50 11,70 700 19 4327.0127.70 13,30 1000 19 4327.0127.100 15,70 1 x 1 300 25 4327.0134.30 15,50 500 25 4327.0134.50 17, 60 700 25 4327.0134.70 19,70 1000 25 4327.0134.100 23,20 Other lengths available on request. female thread/bend female x bend Length mm inside mm Art. No../each 1/2 x 1/2 300 14 4327.0221.30 8,90 500 14 4327.0221.50 10,50 700 14 4327.0221.70 11,70 1000 14 4327.0221.100 13,60 3/4 x 3/4 300 19 4327.0227.30 10,40 500 19 4327.0227.50 11,70 700 19 4327.0227.70 13,30 1000 19 4327.0227.100 15,70 1 x 1 300 25 4327.0234.30 15,50 500 25 4327.0234.50 17, 60 700 25 4327.0234.70 19,70 1000 25 4327.0234.100 23,20 Other lengths available on request. Fexible connection 67

Armoured hoses for heating/air condition systems with stainless steel braiding -armoured hoses for heating and air-conditioning systems, stainless steel braiding with red identification marking Length female thread/outer thread female x male Length mm inside mm Art.-No../each 1/2 x 3/8 300 9 4315.0102.30 3,10 500 9 4315.0102.50 3,90 1/2 x 1/2 300 9 4315.0104.30 3,40 500 9 4315.0104.50 4,20 1/2 x 1/2 300 12 4315.1104.30 4,90 500 12 4315.1104.50 6,10 700 12 4315.1104.70 7, 50 1000 12 4315.1104.100 9,50 3/4 x 1/2 300 12 4315.1105.30 5,70 500 12 4315.1105.50 6,90 1/2 x 3/4 300 12 4315.1106.30 6,50 500 12 4315.1106.50 8,40 3/4 x 3/4 300 12 4315.1107.30 6,30 500 12 4315.1107.50 7, 60 700 12 4315.1107.70 8,90 1000 12 4315.1107.100 10,70 1/2 x 1/2 300 14 4325.1121.30 6,10 500 14 4325.1121.50 7,40 700 14 4325.1121.70 8,80 1000 14 4325.1121.100 10,70 3/4 x 3/4 300 19 4325.1127.30 8,50 500 19 4325.1127.50 10,20 700 19 4325.1127.70 11,80 1000 19 4325.1127.100 14,50 1 x 1 300 25 4325.1134.30 12,40 500 25 4325.1134.50 15,20 700 25 4325.1134.70 18,00 1000 25 4325.1134.100 22,00 1 1/4 x 1 1/4 300 32 4325.1142.30 26,10 500 32 4325.1142.50 30,90 700 32 4325.1142.70 35,70 1000 32 4325.1142.100 42,90 1 1/2 x 1 1/2 300 40 4325.1148.30 43,70 500 40 4325.1148.50 49,40 700 40 4325.1148.70 55,10 1000 40 4325.1148.100 63,60 2 x 2 500 50 4325.1160.50 70,30 700 50 4325.1160.70 78,40 1000 50 4325.1160.100 90,70 Other lengths available on request. 68

Armoured hoses for heating/air condition systems with stainless steel braiding Length female thread/female thread female x female Length mm inside mm Art. No../each 3/8 x 3/8 300 9 4315.0201.30 2,90 500 9 4315.0201.50 3,70 1/2 x 1/2 300 9 4315.0204.30 3,50 500 9 4315.0204.50 4,30 1/2 x 1/2 300 12 4315.1204.30 4,90 500 12 4315.1204.50 6,10 3/4 x 3/4 300 12 4315.1207.30 6,30 500 12 4315.1207.50 7, 60 1/2 x 1/2 300 14 4325.1221.30 6,10 500 14 4325.1221.50 7, 40 700 14 4325.1221.70 8,80 1000 14 4325.1221.100 10,70 3/4 x 3/4 300 19 4325.1227.30 8,50 500 19 4325.1227.50 10,20 700 19 4325.1227.70 11,80 1000 19 4325.1227.100 14,50 1 x 1 300 25 4325.1234.30 12,40 500 25 4325.1234.50 15,20 700 25 4325.1234.70 18,00 1000 25 4325.1234.100 22,00 1 1/4 x 1 1/4 300 32 4325.1242.30 26,10 500 32 4325.1242.50 30,90 700 32 4325.1242.70 35,70 1000 32 4325.1242.100 42,90 Other lengths available on request. Length Length Outer thread/bend male x bend Length mm inside mm Art. No../each 1/2 x 1/2 300 14 4327.1121.30 9,40 500 14 4327.1121.50 11,20 700 14 4327.1121.70 12,40 1000 14 4327.1121.100 14,60 3/4 x 3/4 300 19 4327.1127.30 12,00 500 19 4327.1127.50 13,50 700 19 4327.1127.70 15,10 1000 19 4327.1127.100 18,50 1 x 1 300 25 4327.1134.30 17,20 500 25 4327.1134.50 19,00 700 25 4327.1134.70 22,70 1000 25 4327.1134.100 26,70 Other lengths available on request. female thread/bend female x bend Length mm inside mm Art. No../each 1/2 x 1/2 300 14 4327.1221.30 9,40 500 14 4327.1221.50 11,20 700 14 4327.1221.70 12,40 1000 14 4327.1221.100 14,60 3/4 x 3/4 300 19 4327.1227.30 12,00 500 19 4327.1227.50 13,50 700 19 4327.1227.70 15,10 1000 19 4327.1227.100 18,50 1 x 1 300 25 4327.1234.30 17,20 500 25 4327.1234.50 19,00 700 25 4327.1234.70 22,70 1000 25 4327.1234.100 26,70 Other lengths available on request. Fexible connection 69

-silicone, Armoured hose for cold water mains, heating, and climate-control systems The product: NEW Armoured hoses with stainless steel braiding and red/red blue identification marking For domestic water sector as per DVGW (Test W543, W 270, KTW-A), Group I TÜV-certified for heating and climate-control systems female hose made of silicone, secure against bacteria (no smell, anti-allergic, neutral taste) Resistant to water and anti-freeze on glycol base (max. 50%) For temperatures up to +90 ºC Highly flexible Operating pressure up to 10 bar Conditioned manufacturing tolerances max. +/- 2.5 % Follow assembly and installation instructions in accordance with the current technical information brochure. Length female thread/outer thread W 543, W 270, KTW-A female x male Length mm inside mm Art. No../each 1/2 x 1/2 300 13 5615.1104.30 5,90 500 13 5615.1104.50 7,90 700 13 5615.1104.70 9,80 1000 13 5615.1104.100 13,10 3/4 x 1/2 300 13 5615.1105.30 6,30 500 13 5615.1105.50 8,30 1/2 x 3/4 300 13 5615.1106.30 6,60 500 13 5615.1106.50 8,60 3/4 x 3/4 300 13 5615.1107.30 7,20 500 13 5615.1107.50 9,10 700 13 5615.1107.70 11,00 1000 13 5615.1107.100 14,40 3/4 x 3/4 300 18 5625.1127.30 9,90 500 18 5625.1127.50 13,80 700 18 5625.1127.70 17, 60 1000 18 5625.1127.100 23,30 1 x 1 300 25 5625.1134.30 14,40 500 25 5625.1134.50 19,40 700 25 5625.1134.70 24,40 1000 25 5625.1134.100 31,90 1 1/4 x 1 1/4 300 32 5625.1142.30 28,60 500 32 5625.1142.50 35,30 700 32 5625.1142.70 42,00 1000 32 5625.1142.100 51,90 Length female thread/female thread female x male Length mm inside mm Art. No../each 1/2 x 1/2 300 13 5615.1204.30 5,70 500 13 5615.1204.50 7,70 700 13 5615.1204.70 9,60 1000 13 5615.1204.100 12,80 3/4 x 3/4 300 13 5615.1207.30 6,60 500 13 5615.1207.50 8,70 3/4 x 3/4 300 18 5625.1227.30 9,90 500 18 5625.1227.50 13,80 700 18 5625.1227.70 17,60 1000 18 5625.1227.100 23,30 1 x 1 300 25 5625.1234.30 14,40 500 25 5625.1234.50 19,40 700 25 5625.1234.70 24,40 1000 25 5625.1234.100 31,90 1 1/4 x 1 1/4 300 32 5625.1242.30 28,60 500 32 5625.1242.50 35,30 700 32 5625.1242.70 42,00 1000 32 5625.1242.100 51,90 Other lengths available on request. 70

-silicone for cold water mains, heating, and climate-control systems Outer thread/bend Length male x bend Length mm inside mm Art. No../each 1/2 x 1/2 300 13 5615.1604.30 6,20 500 13 5615.1604.50 8,50 700 13 5615.1604.70 10,70 1000 13 5615.1604.100 14,20 3/4 x 3/4 300 18 5627.1127.30 11,20 500 18 5627.1127.50 15,00 700 18 5627.1127.70 18,90 1000 18 5627.1127.100 24,60 1 x 1 300 25 5627.1134.30 15,30 500 25 5627.1134.50 20,30 700 25 5627.1134.70 25,30 1000 25 5627.1134.100 32,80 Other lengths on request Innengewinde/Bogen Length female x bend Length mm inside mm Art. No../each 1/2 x 1/2 300 13 5615.1704.30 6,10 500 13 5615.1704.50 8,40 700 13 5615.1704.70 10,40 1000 13 5615.1704.100 13,30 3/4 x 3/4 300 18 5627.1227.30 11,20 500 18 5627.1227.50 15,00 700 18 5627.1227.70 18,90 1000 18 5627.1227.100 24,60 1 x 1 300 25 5627.1234.30 15,30 500 25 5627.1234.50 20,30 700 25 5627.1234.70 25,30 1000 25 5627.1234.100 32,80 Other lengths on request -silicone for dishwashers and washing machines female thread/bend female x bend Length mm inside mm Art. No../each 3/4 x 3/4 1000 13 5615.1707.100 14,70 2000 13 5615.1707.200 24,70 Fexible connection Length Other lengths on request 71

-silicone for cold water mains, heating, and climate-control systems Fittings hoes for the domestic water sector DVGW, Gruppe I (W 543, W 270, KTW-A) Stainless steel braiding with red/red/blue identification marking Temperature up to 90 ºC, operating pressure up to 10 bar W 543, W 270, KTW-A female thread/outer thread (Fig. 1) female/male Length mm inside mm Art.-No../each 1/2 x 3/8 300 8 5615.0102.30 3,10 500 8 5615.0102.50 4,00 1/2 x 1/2 300 8 5615.0104.30 3,40 500 8 5615.0104.50 4,60 Length Length Length female thread/female thread (Fig. 2) female/female Length mm inside mm Art.-No../each 3/8 x 3/8 300 8 5615.0201.30 2,90 500 8 5615.0201.50 3,80 1/2 x 3/8 300 8 5615.0202.30 3,30 500 8 5615.0202.50 4,20 1/2 x 1/2 300 8 5615.0204.30 3,60 500 8 5615.0204.50 4,60 Fig. 1 Fig. 2 Fig. 3 female thread/bend (Fig. 3) female/bend Length mm inside mm Art.-No../each 3/8 x 3/8 300 8 5617.0201.30 4,40 500 8 5617.0201.50 5,30 Crimp connection/pipe end (Fig. 4) KLV x pipe Length mm inside mm Art.-No../each 10 mm x 10 mm300 8 5615.5310.30 3,20 500 8 5615.5310.50 4,10 Length Length Length female thread/crimp connection (Fig. 5) female x KLV Length mm inside mm Art.-No../each 3/8 x 10 mm 300 8 5615.2210.30 3,50 500 8 5615.2210.50 4,40 1/2 x 10 mm 300 8 5615.2212.30 3,60 500 8 5615.2212.50 4,50 Fig. 4 Fig. 5 Fig. 6 female thread/pipe end (Fig. 6) female x pipe Length mm inside mm Art.-No../each 3/8 x 10 mm 300 8 5615.5210.30 2,70 500 8 5615.5210.50 3,60 1/2 x 10 mm 300 8 5615.5212.30 3,10 500 8 5615.5212.50 4,00 Other lengths on enquiry 72

Accessories and special hoses AVersion pc/box Art. No. /each Nippel MS (flat-sealing) 3/8 10 43.66122 1,55 Nickel-plated 1/2 10 43.66123 1,70 3/4 10 43.66124 2,90 1 5 43.66125 4,00 1 1/4 1 43.66126 7,70 1 1/2 1 43.66133 11,00 female/male nipple MS 3/8 10 43.66132.10 1,55 (flat-sealing, nickel-plated) 1/2 10 43.66131.10 2,10 3/4 10 43.66127.10 3,20 1 5 43.66128.5 5,90 1 1/4 3 43.66129.3 7,70 1 1/2 2 43.66135.2 14,90 2 1 43.66136.01 53,10 female/male angle element MS 3/8 5 43.66141.5 3,10 (flat-sealing, nickel-plated) 1/2 5 43.66142.5 4,40 3/4 5 43.66143.5 5,90 1 5 43.66144.5 8,20 1 1/4 3 43.66145.3 15,00 1 1/2 2 43.66137. 2 27,60 2 1 43.66138.1 54,00 Seal (asbestos-free) 3/8 100 43.66151. 100 0,28 1/2 100 43.66152.100 0,28 3/4 100 43.66153.100 0,34 1 100 43.66154.100 0,34 1 1/4 100 43.66155.100 0,56 1 1/2 100 43.66156.100 0,63 2 100 43.66157. 100 0,95 Length Gas pressure hoses with stainless steel braiding (Operating pressure 4 bar); stainless steel corrugated pipe with stainless steel braiding (DVGW tested), tempered cast screw fitting with female thread and conical seal on one side, tempered cast hexagonal nipple with outer thread on the other side. Technical data Use for gas pipes and heating systems, stainless steel corrugated pipe (material No. 1.4404) with braiding (material No. 1.4301) Operating pressure for gas: 4 bar Operating data for heating: 25 bar at + 20 ºC 20 bar at +100 C 17 bar at +200 C 15 bar at +300 C Version Length mm Art. No../each Connection size = 1/2 DN 12 300 46163.30 66,40 500 46163.50 74,60 700 46163.70 89,00 1000 46163.100 94,00 Connection size = 3/4 DN 20 300 46162.30 80,70 500 46162.50 99,80 700 46162.70 128,00 1000 46162.100 127,00 Connection size = 1 DN 25 300 46161.30 97,10 500 46161.50 113,00 700 46161.70 145,00 1000 46161.100 154,00 Other sizes and connections on enquiry. Fexible connection 73

Meibes fittings Components for rapid installation The products: Meipass pipe intersection fittings Gravity brakes Ball valves Other fittings Your advantage: Durable and maintenance-friendly fittings Reduced installation times Approved quality 74

Expansion compensators Expansion compensator H6 Longitudinal expansion compensator with protective guide housing with pipe ends soldered on at the plant every 10 cm of length. Material: Bronze expansion sleeve, housing made of copper. Operating pressure: Max. 3 bar, operating temperature: Max. 110 ºC Follow the installation instructions from the current technical information brochure. Version Expansion accommodation Art. No../each DN 15 up to 7 mm 62220 20,60 DN 18 up to 7 mm 62230 23,10 DN 22 up to 7 mm 62240 24,10 DN 28 up to 7 mm 62250 30, 80 DN 35 up to 7 mm 62260 37,20 Expansion compensator SI 10 Solderable or screw-fitting longitudinal expansion compensator with protective guide housing. Material: Stainless steel expansion sleeve, housing and connections made of brass. Operating pressure: Max. 10 bar, operating temperature: Max. 130 ºC. Available with soldered ends or screw connections with female threads. Follow the installation instructions from the current technical information brochure. Version Expansion accommodation with female Art. No../each DN 15 up to 5 mm female = 1/2 62416* 62415* 44,30 DN 18 up to 5 mm 62418* 46,30 DN 22 up to 5,5 mm female = 3/4 62423* 62422* 56,60 DN 28 up to 6 mm female = 1 62429* 62428* 68,30 DN 35 up to 6 mm female = 1 1/4 62440* 62435* 84,90 DN 42 up to 11 mm female = 1 1/2 62444 62442 119,00 DN 54 up to 10 mm female = 2 62455 62454 194,00 *up to DN 35 with stroke and tension limitation Expansion compensator ES Stainless steel expansion sleeve and housing. Operating pressure: Max. 10 bar, operating temperature: Max. 130 ºC. Follow the installation instructions from the current technical information brochure. With welded ends consisting of ST 37 DN 65 (without protection and guide sleeve) 62465 OR 291,00 Other sizes and versions on request. Fittings 75

Gravity brakes d D h Version Art. No../each TYPE SB IR (in pipe non-return units) Backflow inhibitor made of brass, with seal, no space requirement, for installation in screw connections and fittings, dimensions in mm. FL = 3/4 h=23,5 d=20 D=30,5 58120 9,90 FL = 1 h=30 d=25 D=38,5 58100 10,20 FL = 1 1/4 h=30 d=31,5 D=50 58110 12,80 as above, but with air lock FL = 3/4 58121 11,20 FL = 1 58101 11,50 FL = 1 1/4 58111 14,20 Type SB TS (thermal shut-off) Gravity brake made of brass for direct screw fitting onto the pump body, with manual adjustment. female and male = 1 1/2 58130 18,00 female and male = 2 58140 24,90 as above, but with air lock female and male = 1 1/2 58131 19,30 female and male = 2 58141 26,30 Type SB female Gravity brake with female thread/flange, with manual adjustment FL and female = 1 (for union nuts 1 1/2 ) 58051 17,70 FL and female = 1 1/4 (for union nuts 2 ) 58058 26,30 as above, but with air lock FL and female = 1 (for union nuts 1 1/2 ) 58052 19,00 FL and female = 1 1/4 (for union nuts 2 ) 58059 27,80 Type SB male Gravity brake with outer thread/flange, with union nut and seal, manual adjustment FL and male = 1 (for union nuts 1 1/2 ) 58080 12,60 FL and male = 1 1/4 (for union nuts 2 ) 58081 17,00 as above, but with air lock FL and male = 1 (for union nuts 1 1/2 ) 58079 14,00 FL and male = 1 1/4 (for union nuts 2 ) 58078 18,20 Type SB male Gravity brake with outer thread/flange, with union nut and seal, manual adjustment FL 1 ; male 1 1/2 (for union nuts 1 1/2 ) 58041 18,10 FL 1 1/4 ; male 2 (for union nuts 2 ) 58046 26,30 as above, but with air lock FL 1 ; male 1 1/2 (for union nuts 1 1/2 ) 58043 19,00 FL 1 1/4 ; male 2 (for union nuts 2 ) 58054 27,80 Type SB RV (Euro RV) made of brass, bushing on both sides female = 3/8 58200 5,50 female = 1/2 58210 6,00 female = 3/4 58220 7,70 female = 1 58230 10,10 female = 1 1/4 58240 15,70 female = 1 1/2 58250 22,00 female = 2 58260 30,00 FL = Flange male = Outer thread female = female thread 76

Shut-off valves and threaded/flanged ball valves Version Art. No../each Pump slide valve Bushing on one side, Meibes special flange on the other side. Steam 6.5 bar up to 160 ºC; water, oil, air: 9 bar up to 110 ºC FL and female = 1 (for union nut 1 1/2 ) 61340 13,20 Pump slide valve but with gravity brake FL and female = 1 (for union nut 1 1/2 ) 68202 17,60 Ball valve, female/female Brass, standard design, with red butterfly toggle, 10 bar up to 130 ºC female= 3/8 61920.1 5,30 female = 1/2 61930.1 5,50 female = 3/4 61940.1 7,90 female = 1 61950.1 11,80 female = 1 1/4 61960.1 17,40 Ball valve female/male Brass, with red butterfly toggle, 10 bar up to 130 ºC 1/2 61972.3 6,40 3/4 61971.3 8,30 1 61970.3 11,80 Ball valve with Meibes flange Brass, for pumps and pipes, with red toggle, 10 bar up to 110 ºC FL and female = 1 (for nuts 1 1/2 ) 61810 13,20 FL and female = 1 1/4 (for nuts 2 ) 61840 27,40 Kugelhahn mit Meibes-Flansch Messing, mit integrierter Schwerkraftbremse, mit rotem Knebel, für Pumpen und Rohrleitungen, 10 bar bis 110 C FL and female = 1 (for nuts 1 1/2 ) 61850 19,90 FL = Flange female = female thread male = Outer thread Fittings 77

Flange ball valves/pipe intersection fittings Version Art. No../each Ball valve with Meibes flange Brass, with integrated gravity brake, with red toggle, for pumps and pipes, with air lock, 10 bar up to 110 ºC FL and female = 1 (for nuts 1 1/2 ) 61851 21,30 FL and female = 1 1/4 (ffor nuts 2 ) 61861 34,10 Ball valve, light Ball valve 1 female, with short flange for union 1 1/2 ; shut-off possibility with interior hexagonal socket and screwdriver slot, 10 bar up to 110 ºC FL and female = 1 (for nuts 1 1/2 ) 61804 8,80 FL = Flange female = Internal thread Union nut and seal Union nut 1 1/2" oder 2 including seal Union nut/seal 1 1/2 für (flange 1 ) 43.550 D 3,80 Union nut/seal 2 für (flange 1 1/4 ) 42602.01 D 7,60 -double intersection fittings A C AA1 C B Type RA 4 HZ (matches compact radiators and conventional commercial pipe clips), free throughflow 15 mm, connections A=15 mm, B=15 mm, C=15 mm, axial separation 1=50 mm, axial separation 2=35 mm 70633 13,50 A AA2 B Type RA 5 HZ (matches compact radiators and conventional commercial pipe clips), free throughflow 18 mm, connections A=18 mm, B=18 mm, C=15 mm, axial separation 1=50 mm, axial separation 2=35 mm 70641 14,50 A C AA1 A C B AA2 B Type RA 5 (matches compact radiators) free throughflow 18 mm, connections A=18 mm, B=18 mm, C=15 mm, axial separation 1=50 mm, axial separation2=30 mm 70611 14,00 -connection element between Meipass pipe fittings and radiator valve, especially well-suited for connection to valve radiatorsr Bends made of copper pipe for soldered or screw connections 15 x 1, arm lengths 65 x 100 mm 10540.02 2,90 78

Fittings Thermometers Thermometer, centric contact for pump groups Edition 7 Art.-No../each Red 58071.504 8,80 Blue 58071.505 8,80 Thermometers Contact thermometers, eccentric Version Art. No../each rot Ø 63 58071.05 9,40 blau Ø 63 58071.06 9,40 Connection fitting 1 female/male with lateral female thread 1/2 for connection of immersion thermometers, meter sensors, pressure gauges, or KFE ball valves 90256.10 7,40 Automatic mixer Thermostatic water mixer with an adjustment range from 30 ºC 60 ºC for hot water or temperature limitation in the heating system. Operating pressure max. 10 bar, connection dimension G 3/4 male 69050.5 56,80 Automatic mixer Fully adjustable from 35 ºC 65 ºC for hot water, 10 bar, with 3 clamp ring screw fittings 22 mm 69050 49,30 Safety valves for heating systems to DIN 4751, Part 2, TÜV-approved, type KD 1/2 x 3/4, MS 3 bar 69010.01 5,60 Safety valves for hot water systems TÜV-approved, type KBD (other pressures on enquiry) 1/2 x 3/4, MS 6 bar 69030 8,30 Sicherheitsventile mit Manometer für Heizungen to DIN 4751, Part 2, TÜV-approved 1/2 x 3/4, MS 3 bar 69020.12 12,40 Ring air bleeder for radiators 1 1/4 connection complete with seal Steel stoppers with brass ring, left-hand thread 1 1/4 67041 5,30 Steel stoppers with brass ring, right-hand thread 1 1/4 67051 5,30 Fittings strainer with KFE ball valve for emptying Suitable for vertical installation. Filter can be rinsed without replacing 58326.2 35,20 79

Fittings Version Art. No../each Overflow set ÜS for automatic pressure compensation for easy flat-sealing installation on 3-way ball valves or other 3/4 connections between flow and return circuits. Overflow valve 3/4 with visual display and connection parts Axial separation = 125 mm (can be shortened by customer) 69072.4 34,50 Axial separation = 200 mm (can be shortened by customer) 69072.2 35,90 Automatic air bleeder Brass, with 10 bar brass shut-off valve, 110 ºC, with reliable function even under repeated bleeding; additional upper expansion sealing with vertical outlet 3/8 67500 12,40 with side outlet, e.g. for radiators 3/8 67600 12,70 with vertical outlet 1/2 67502 12,80 with side outlet 1/2 67602 15,70 expansion vessel* cap valve Allows for rapid maintenance or replacement of the expansion vessel* without having to drain the system. Complete with pressure gauge for checking the system and vessel pressure without dismantling the vessel, with drain facility, including sealable cap. Can be used for 3/4 and 1 69088 54,40 *MEV = Membrane Expansion Vessel expansion vessel* service coupling for heating system Safety quick-action coupling to DIN 4751, Sheet 2/93, allows for rapid replacement of the expansion vessel* without draining the heating water, 3/4 male x 3/4 female Brass 69080 11,80 as above but for solar power systems 69080.3 13,90 KFE (fill-empty) ball valve with cap, hose socket, and lever 1/2. Brass 65051 MS 5,20 KFR safety feed valve Combined unit of KFE ball valve with grommet and non-return valve 1/2. Brass 65053 MS 16,60 Filly Automatic filling aid for heating systems, keeps the pressure constant. Suitable for pressures up to 10 bar. Controllable between 0.4 3 bar (preset to 1.5 bar), connected between the filling hoses and connected with hose clips. Type RM 8: (8 l/min) with filter, nonreturn valve, pressure gauge on one side, 1/2 female, and hose screw connection with clamp 59092 45,30 80

Compression screw fittings Version pc/box Art. No../each Type 610 (bushing) 15 mm 10 G 29610.2 2,70 18 mm 10 G 29610.4 3,30 22 mm 10 G 29610.5 4,40 Type 612 converter screw fittings female 15 mm x 1/2 10 G 29611.4 3,20 15 mm x 3/4 10 G 29611.5 4,00 18 mm x 1/2 10 G 29611.8 4,10 18 mm x 3/4 10 G 29611.9 4,00 22 mm x 3/4 5 G 29611.11 4,40 22 mm x 1 5 G 29611.12 5, 50 28 mm x 1 5 G 29611.14 6,60 35 mm x 1 1/4 3 G 29611.15 13, 10 Typ 612 Übergangsverschraubung IG 15 mm x 1/2 10 G 29612.4 3,00 15 mm x 3/4 10 G 29612.5 3,70 18 mm x 1/2 10 G 29612.8 2,80 22 mm x 3/4 10 G 29612.10 3,60 22 mm x 1 5 G 29612.11 5,10 28 mm x 1 5 G 29612.12 5,10 Type 615 (angle) 15 mm 10 G 29615.2 3,00 18 mm 10 G 29615.4 4,00 22 mm 5 G 29615.5 4,70 Type 616 converter screw fittings male 15 mm x 1/2 10 G 29616.3 4,00 18 mm x 3/4 5 G 29616.8 5,20 22 mm x 3/4 5 G 29616.7 6,20 22 mm x 1 5 G 29616.6 8,30 28 mm x 1 3 G 29616.9 8,90 Type 618 (T-piece) 15 mm 10 G 29618.210 4,80 18 mm 5 G 29618.405 5,20 22 mm 5 G 29618.505 6,50 Type 648 reducing rings 18 mm x 15 mm 10 G 29648.310 2,15 22 mm x 15 mm 10 G 29648.510 1,65 22 mm x 18 mm 10 G 29648.610 2,15 Fittings 81

Checklist for an enquiry regarding LogoFresh fresh water stations Bitte senden an: Meibes System-Technik GmbH, Ringstrasse 18, 04827 Gerichshain Fax: +49 (0) 34292/ 713-50 Heating system Type of use of object (E.g. Apartment building, hotel, sports facility, etc.) Minimum run-in temperature of the heating system (standard 65 ºC): C Heat generating capacity/buffer storage volume possibly already available: kw / l Fresh water station Number and type of taps (bath, shower, laundry room, etc.) and allocation to area (bathroom, kitchen) or total hot domestic water flow rate: Possible existing requirement for hot domestic water flow rate per tapping point (DIN Standard): Hot domestic water outlet temperature (standard 50 ºC) C Possible requirement for simultaneous function (standard DIN): 82

Large-scale manifold Enquiry form for large-scale manifold system Delivery rate m 3 /h 12 30 50 100 Output at ΔT=20 K kw 280 700 1150 2300 at ΔT=10 K kw 140 350 580 1150 Meibes System-Technik GmbH Ringstraße 18 04827 Gerichshain Fax: +49 (0) 34292/ 713-50 Side connections Victaulic-groove pipe 114,3 168,3 168,3 219,1 2-circuit module 3-circuit module Please enter required quantity. Angle module Pump groups Heating circuit 1 2 3 4 5 6 7 8 Delivery rate m 3 /h Vorhandene Existing output at ΔT=20 K kw Daten angeben. at ΔT=10 K kw Pump Note: DN 25, 30: Thread DN 40, 50, 65: Flange Name/ Type with mixer (IInfo: DN mixer = DN pump) with servomotor (3-point drive, 220V/50Hz) Please tick as applicable. Transitions to the heating circuit (1 pair) (DN 40, 50 and 65 only) Victaulic - Victaulic Victaulic - male thread Victaulic - welded end Please tick as applicable. Heating maintenance unit Delivery rate m 3 /h 6 12 30 50 100 Output bei ΔT=20 K kw 135 280 450 700 1150 bei ΔT=10 K kw 70 140 230 350 580 Side connections Victaulic-groove pipe 60,3 88,9 114,3 168,3 219,1 Transitions from heating maintenance unit to the manifold or angle incl. insulation block Hydraulic diverter function Magnetite separator Transitions to the heat generator (1 pair) yes no Please tick as applicable. Subject to change without notice. Transitions from heating maintenance unit, manifold or angle to the network Victaulic - Victaulic Heating maintenance unit/manifold/angle Network pipe pipe mm mm Quantity 60,3 48,3 60,3 88,9 114,3 168,3 219,1 76,1 88,9 60,3 76,1 88,9 114,3 141,3 168,3 219,1 Victaulic - flange (PN6) Heating maintenance unit/manifold/angle Network pipe flange mm DN Quantity 60,3 40 50 88,9 114,3 168,3 219,1 65 80 50 65 80 100 125 150 200 Victaulic - welded end Heating maintenance unit/manifold/angle Network pipe pipe mm DN Quantity 60,3 48,3 60,3 88,9 114,3 168,3 219,1 76,1 88,9 60,3 76,1 88,9 114,3 139,7 168,3 219,1 Notes Name: Company: Street: Town/City Tel.: Fax:

For the Logotherm product ranges Apartment stations, decentralised heat distribution and domestic water heating District heating stations Consumption water distribution Water manifolds please ask for the separate price lists www.meibes.de 84

Index A Air heater shut-off set Page 13 Armoured hoses and accessories Page 66-73 Automatic air bleeders Page 79-80 Automatic mixer Page 79 B Backflow inhibitors Page 76 Ball valves Page 77-78 Boiler charge set Page 11 Boiler connection assemblies Page 4-9 Brine manifold Page 19 C Circontrol Page 13 Compression screw fittings Page81 Connection fittings Page 65, 73, 81 Connecting tube assemblies Page 11 Constant heat regulation set Page7 Coupling for expansion vessels Page 80 Corrugated pipes Page 62-65, 44-45 Corrugated pipe connection set Page 46-47, 64-65 D Double intersection fittings (Meipass) Page 78 E Elbow for large manifold Page 55 Expansion compensators Page 75 Expansion sets Page 11, 43 Expansion sleeves Page 75 Expansion vessel cap valve Page 80 Expansion vessel cap valve/ service coupling Page 80 F Fittings Page 79-80 FixLock Page46, 64 Flange - pump groups (FL-UK/FL-MK) Page 60-61 Flange swaging set/accessories Page 65 Flexible connections Page 44, 63 Filling fittings/sets Page 80 Filling pump set (solar) Page 43 Fresh water station Page 48-51 G Gas pressure hoses Page 73 Gas pressure hoses with stainless steel braiding Page 73 Gravity brakes Page 76 Seite 48-53 H Heat exchanger solar station Page 28-29, 36-41 Heating maintenance unit Page 54, 11 Heat meter assemblies Page 6 Heat pump connection group Page 19 Hose accessories Page 73 Hoses Page 66-73 I Inoflex stainless steel corrugated pipes Page62-65 Inoflex stretch connection pipes made from stainless steel Page 63 K Klemmringverschraubungen Seite 75 Konstantwertregel-Set Seite 7 Kugelhähne Seite 71-72 Kupplung für Ausdehnungsgefäße Seite 74 L Large manifold system Page 52-61 LogoFresh fresh water station Page 48 Logotherm products separate price list Low-loss header Page 59, 11 M Magnetite separator Page 59 Manifold blocks Page 10, 55, 59 Manifold pump groups (V-UK/V-MK) Page 57-58 Manifolds Page 10, 19, 55, 59 Meiflex armoured hoses Page66-73 Meipass double intersection fittings Page 78 Meter assemblies Page 6 Mixer motor Page10, 58 O Oval clamp set Page 46 Overflow sets Page 10, 80 P Power filling station Page 43 Pump ball valves Page77-78 Pump groups (UK/MK) Page4-6 / 57-58 Pump shut-off sets Page 12-13 Pump slide valves Page 77 R Rapid air bleeder Page 80 Reducer set Page 59 Remote heating stations separate price list Return set Page 12 Return temperature regulation Page 8 Ring air bleeder Page 79 S Safety compensator Page 45 Safety feed valve Page 80 Safety group Page 11, 17, 37 Safety valves Page 79 Scavenging and filling valve Page 80 Separating systems Page 9, 16, 28-29, 36-41 Servomotors Page 10, 58 Shut-off sets Page 12-13, 77-78 Silicon armoured hoses Page 70-72 Solar connection equipment Page 43-47 Solar controller Page 42 Solar manual filling pump Page 43 Solar split system M Page 28-29 Solar stations Page 20-41 Solar station S Page 21-23 Solar station M Page 24-31 Solar station L Page 34-35 Solar station XL Page 36-39 Solar station XXL Page 40-41 Solaventec Page 32-33 Stainless steel corrugated pipes Page 44/45, 62-65