Rotameter series 250 metal tube variable area flowmeter

Similar documents
Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Ar-Mite TM Low Flow Armored Flowmeter

Level gauges Series LS Level indicator, switch and transmitter for liquids

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

PEPPERL+FUCHS GmbH

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Direct reading flowmeters type RM

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. Dimensions

Brooks MT3750 Low Flow Armored Flowmeter

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Inductive slot sensor

Flow Measurement SITRANS F C

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Ultrasonic Level Measurement nivopuls FDU 10 S

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Gas cylinder scale Model GCS-1

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Manual Power relay SR853

Technical Data. Dimensions

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

Supplementary Installation and Operating Instructions. Category II2G

Transmitters/Sensors. OLCT Series

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 5100 EC Detection of toxic gases and vapors

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Dräger Polytron 8000 Stationary gas detector (EC)

ProcessMaster, HygienicMaster FEX300, FEX500

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET-1000 (12 VDC)

DICTATOR Hold-Open Systems for Hazardous Areas

Model 144H. Product Data Sheet , Rev DB February Content

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Technical Data. Dimensions

OPTIBAR P 1010/2010 C Supplementary instructions

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Flange immersion heaters

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

VERSAFLOW VORTEX Supplementary instructions

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Dräger Polytron 5700 IR Detection of flammable gases and vapours

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

Annubar Flowmeter Series

Fan Heaters Type VLEx

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

SET Installation and Operating Instructions. Level switch for one sensor

Certificate of Compliance

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Bristol Babcock Oil Content Monitor "oil in water"

Enraf Servo Gauge 854 XTG

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

General Specifications

Oil Leak Detector NAR300 System

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Rosemount 3051CFP Integral Orifice Flowmeter

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

SIMRAD GD10 IR GAS DETECTOR

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Danfoss gas detection unit Type GD Heavy Duty

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Ultrasonic Flowmeters SITRANS F US SONO Operating instructions 01/2010 SITRANS F

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

WIO200 Water In Oil measuring instrument

Rosemount 3490 Series

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Level Measurement Continuous level measurement Ultrasonic transmitters

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Dräger Polytron 8000 Stationary gas detector (EC)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Glass Tube Variable Area Flowmeter

Transcription:

Technical data Sheet Flow meter Rotameter series 250 metal tube variable area flowmeter MODELES 250 Stainless Steel indicator 250 PTFE 250 indicator + Alarm 250 electronic transmitter 4-20mA 250 electronic transmitter 4-20mA ADF Houdec Instrument SAS

Flow meter Technical data Sheet Page 2

Technical data Sheet Flow meter Principle The instrument must be mounted in a vertical pipe with fluid circulation in the upwards direction. The self guiding cylindrical float is positioned inside a tapered tube. When the flow passes through the meter the float rises to a position of equilibrium where the weight of the float is balanced by the net force due to the fluid pressure. The float is magnetically coupled to a pointer indicating the rate of flow on the front scale. Applications The metal tube 250 series variable area flow meter is a specially designed instrument for measuring the flow of liquids and gases. Its robust design makes it highly suitable for use on hazardous and corrosive applications as found in most industrial processes. Description The instrument comprises: - A body formed in stainless steel with fixed flange connection - A stainless steel or an alloy float fitted with a magnet, with guide rods at each end - Two end stops in stainless steel used as a guide for the float - An indicator housing unit in aluminium alloy Features -Choice of connections - Industry standard length - High accuracy calibration option - Robust design - Magnetically coupled local indicator, transmitter option - Alarm options - PTFE versions available - Fastrack delivery on selective models Page 3

Flow meter Technical data Sheet Technical characteristic Precision : 2% of the maximum capacity (PTFE 3%) (class 1.6 VDI; VDE 3513 on request). Report/ratio of scale: 1 to 10 Extended of scale: to see table Ranges of flows. Pressure of service: Stainless 40 bar out of standard Up to 200 bar on request Note: With liquids, the operating pressure must be at least equal to two time pressure losses of the apparatus. At least five times with gases. Temperature of service Stainless Version: -40 with + 200 C : Version PTFE: -20 with + 125 C Heat shield required according to option Note: Versions high temperatures on request Materials: Parts in contact with the fluid (body and float) Z2 NDT 17.13 stainless (316L) Aluminium Version: Plate alloy support of aluminium, front aluminium cap moulded with epoxy painting/polyester Stainless version: to see options (Z10 code) Protection: Indicating case (IP65) Approximate mass: DN15 (1/2 ") = 4,5kg DN25 (1 ") = 5kg DN50 (2 ") = 8,5kg DN80 (3 ") = 15kg DN100 (4 ") = 18,5kg Conformity - Directives Tige guide de flotteur Flotteur Aimant Disque de mesure Disque de maintien Guide / butée basse 97/23/CE (Equipment under pressure) *, 94/9/CE (ATEX) *, 73/73/CE (Low tension) *, 89/336/CE (CEM) *, 98/37/CE (Machine) * Cadran gradué Aiguille de lecture Alarme basse réglable Flow range table DN 15 (½") 25 (1") 50 (2") 80 (3") or 100 (4") M code LIQUID Max liquid flow rates SG = 1 GAS Flow capacity m3/h MG code Air 20 C 1023 mbar Abs Pressure DROP mbar Code MP PTFE LINED Liquid Max flow SG = 1 pressure DROP M1 100 l/h 35 - M2 160 lh MG2 5 60 MP2 160 l/h 77 M3 250 l/h MG3 7.5 60 MP3 250 l/h 70 M4 400 l/h MG4 12 60 MP4 400 l/h 70 M5 600 l/h MG5 18 65 MP5 600 l/h 77 M6 1 m3/h MG6 30 70 MP6 1 m3/h 80 M5 600 l/h MG5 18 45 MP5 600 l/h 45 M6 1 m3/h MG6 30 80 MP6 1 m3/h 45 M7 1.6 m3/h MG7 48 55 MP7 1.6 m3/h 79 M8 2.5 m3/h MG8 75 80 MP8 2.5 m3/h 45 M9 4 m3/h MG9 120 85 MP9 4 m3/h 84 M10 6 m3/h MG10 180 125 - - - M8 2.5 m3/h MG8 75 55 MP8 4 m3/h 48 M9 4 m3/h MG9 120 80 MP9 6 m3/h 92 M10 6 m3/h MG10 180 55 MP10 10 m3/h 48 M11 10 m3/h MG11 300 80 MP11 6 m3/h 95 M12 16 m3/h MG12 480 95 - - - M13 25 m3/h MG13 750 130 - - - mbar M11 10 m3/h MG11 300 60 MP13 25 m3/h 50 M12 16 m3/h MG12 480 90 MP5 600 l/h 95 M13 25 m3/h MG13 750 60 MP6 1 m3/h 55 M14 40 m3/h MG14 1000 125 MP7 1.6 m3/h 100 M15 50 m3/h MG15 1500 - - - - M16 60 m3/h MG16 1800 - - - - M17 80 m3/h MG17 2400 - - - - Dimensions Standard model dimensions Size PN Ø D ØK ØL N A 15 16 95 65 14 4 80 40 95 65 14 4 80 ½" 150 lbs 88.9 60.3 15.9 4 80 300 lbs 95.2 66.7 15.9 4 80 2 16 115 85 14 4 92 40 115 85 14 4 92 50 150 lbs 107.9 79.4 15.9 4 92 300 lbs 123.8 88.9 19 4 92 1" 16 165 125 18 4 108 40 165 125 18 4 108 25 150lbs 152.4 120.6 19 4 108 300 lbs 165.1 127 19 8 108 80 16 200 160 18 8 122.5 3" 150 lbs 190.5 152.4 19 4 122.5 100 16 220 180 18 8 124 4" 150 lbs 228.6 190.5 19 8 124 Page 4

Technical data Sheet ALARM OPTION Intrinsic safety version «ia» Detectors Standards NAMUR and DIN 19234. Contact numbers with D.C. current 2 wire (SJ3,5. NR. Pepperl&Fuchs) of S.I 2 adjustable (high and/or low alarm) on the totality of the scale Note: Adjustment accessible on the dial with visual witness on the scale from flow. Can be associated the electronic transmitter. Connection on terminals with screw S=2,5mm ². Exit out of standard on press packs polycarbonate PG9 cables 5 to 8 Misters. Nominal voltage Tension of service No-load voltage Consumption Resistance of the line of order Temperature of service 8V= (IH ~ 1 kω) 5 with 25V= (of use of IS) 5.5 V, current of short-circuit Icc 52 ma out of alarm 1 ma except alarm: 3 ma (possible inversion by reversing the position of the detecting disc). 100 Ω 25 C to +60 C In use of a protection of S.I: Ex ia IIC T6 until an ambient temperature of 50 C Ex ia IIC T5 until an ambient temperature of 65 C Ex ia IIC T4 until an ambient temperature of 80 C Parameters relative to IF Cint 40 nf, Lint 160 µh Marking ATEX II 1/2 G Exia IIC T6 N certificate LCIE01ATEX6063X Conformity - Directives 94/9/CE (ATEX), 73/73/CE (low tension) *, 89/336/CE (CEM) *, 98/37/CE (Machine) * * when applicable Amplifiers recommended associated relays (on option) Flow meter Index réglable alarme haute Setting mark low alarm type KFD2-SR2-Ex1.W KFA5-SR2-Ex1.W KFA6-SR2-Ex1.W Power pack 20-30 Vcc 115Vca 45/65Hz 240V~ Consumption 0,5W 1W Cut of the contacts Assembly Classify protection 250V~/2A/cosφ>0,7; 120V~/4A; 40V=/2A on symmetrical rail DIN 35mm or fixing by screw IP20 Ambient temperature - 20 C with + 60 C ATEX Version (S) Note: Version of I.S. [EEx ia] (PTB97ATEX2271) to 1 or 2 input circuits The diagram of connection and dimensions depend on the selected model. To refer to additional documentation. (Wiring Plan and diagram on request). Version with contact and flame-proof case D Marking ATEX II 2G Exd IIC T6 N certificate LCIE01ATEX6060X Contact: Type THEY bistable SPDT Maximum tension 220V Running max 1 A Maximum power 60VA 30W resistive load Classify protection IP 66 Materials Case ADF out of aluminium alloy Electric connections on screw connector block (wire 1,5mm ²) Press standard packing certified aluminium Exd for armoured cables with 5 to 12 mm Conformity - Directives 94/9/CE (Atex), 73/73/CE (low tension) *, 89/336/CE (CEM) *, 98/37/CE (Machine) * * when applicable Notes: taking into account the hysteresis important of the contact THEY, it is recommended to limit the use of the contact with the respective beaches:. Contact with the descent: beach available from 15% to 75% of the full scale. Contact with the rise: beach from 25% to 100% of the full scale. To contact the engineering department for all additional information The apparatus is delivered with a press packs Aluminium Exd out of standard (for cables of 3 to 12 Misters. Other on request Page 5

Flow meter Technical data Sheet ELECTRONIC TRANSMITTER OPTION Standard VERSION (Pointer and scale plate indicator) "T5 code" Output signal: 4 à 20mA proportional from 10 to 100% of flow range 4mA corresponds to 0 of the scale (setted position marked --0). 5,6 ma corresponds to 10% of the fullscale (first measuring value 10%). 20mA corresponds to 100% of the full scale (top measuring value 100%). Transmission: Power supply: Linearity: Temperature deviation: Permissible ambient temperature: Page 6 2 wires (connection : see alarm) UB = 8 to 24 Vcc. 0,5% of max. current < 0.05% / C T= 25 à + 65 C in operation TYPE i250 Intrinsic safety version "T6 code" (to be specify while ordering) ATEX marquing: II 2 G Exia IIC T6 Certificate N : LCIE01ATEX6063X IS Characteristics: Only connect to an approved source in IS version: IS power supply: Conformity - Directives: Note : C interne=0nf; L interne=1,8mh; li=100ma; Pi=0,75W Ex ia lic T6 max. permissible ambient temperature 65 C. Voltage UB <30V dc; 94/9/CE (ATEX), 73/73/CE (Low voltage)*, 89/336/CE (CEM)*, 98/37/CE(Machine)* IS Alarm fitting (1 or 2 pces) is compatible with Is transmitter LCD indicator is not compatible with IS certificate. TYPE 250 B4 Explosion proof housing - "T4 code" (to be specify while ordering) ATEX marquing: II 2 G Exd IIC T6 Certificate N : LCIE01ATEX6060X Housing coating: Characteristics: Power supply: Conformity - Directives: Note : Mechanical OPTIONS Rough Aluminium finish or yellow painted (without dial) Umax = 230V Imax = 15A Pmax = 20W UB = from 8 to 24 Vcc. 94/9/CE (ATEX), 73/73/CE (Low voltage)*, 89/336/CE (CEM)*, 98/37/CE(Machine)* Local LCD indicator is not available in explosion proof version Type 250 B4 Stainless Steel Version - Z10 code - (to be specify while ordering) Stainless steel components (316L): Dimensions: Cover Main Support plate Nuts and screws Magnet assembly, plugs and cable gland(s) Unchanged Use : For corrosive atmospheres. (Sea area,...) Protection Level: IP66 Coating: Non painted in standard version Damper for gas floats - Z1 code (to be specify while ordering) Use : Availability: Generarly use for gas flow processes (could be used for liquid processes if needed) On any Nominal dimensions excepted PTFE version PTFE Version for liquids - C5-C6 code - ((to be specify while ordering) PTFE components Float, all wetted parts, flange seals (see ) Use : For corrosive, chemical processes, (NaOH, Hcl, H2SO4 ) Flow range Min 16-160 l/h - Max. 2,5-25 m3/h Fluid Only liquids Process temperature Max. 120 C Operating pressure Max. 16 bar at 20 C in standard * lorsque applicable

Technical data Sheet Flow meter CODING 250 INSTRUMENT TYPE I Code Connection code I 15 ISO PN Flange NFE 29203/ NE1092 - DN15 I 25 ISO PN Flange NFE 29203/ NE1092 - DN25 I 50 ISO PN Flange NFE 29203/ NE1092 - DN50 I 80 ISO PN Flange NFE 29203/ NE1092 - DN80 I 100 ISO PN Flange NFE 29203/ NE1092 - DN100 I 1/2" Flange ANSI B16-5 DN 1/2" I 1" Flange ANSI B16-5 DN 1 I 2" Flange ANSI B16-5 DN 2" I 3" Flange ANSI B16-5 DN 3" I 4" Flange ANSI B16-5 DN 4" I I Code Measuring element code I I M.. See flow range table I I I Code Construction code I I I C1 STAINLESS STEEL 316, ISO PN16 Flange RF I I I C2 STAINLESS STEEL 316, ISO PN40 Flange RF I I I C3 STAINLESS STEEL 316, Flange ANSI 150# RF I I I C4 STAINLESS STEEL 316, Flange ANSI 300# RF I I I C5 PTFE Construction, ISO PN16 Flange (RF) I I I C6 PTFE Construction, Flange ANSI 150# RF I I I CX Special Construction (on request I I I I Code Transmitter I I I I T6 I.S. magnetic transmitter 4-20mA II2G ATEX ExiaIICT6 (standard housing IP65) I I I I T5 Standard magnetic transmitter 4-20mA (standard housing IP65) I I I I T4 Magnetic transmitter 4-20mA (explosion -proof housing) II2G ATEX ExdIICT6 I I I I I Code Alarms I I I I I S1 1 low alarm (without relay) I I I I I S2 1 high alarm (with relay) I I I I I S3 2 high and low alarms (without relay) I I I I I S4 1 low alarm (with relay) I I I I I S5 1 high alarm (with relay) I I I I I S6 2 high and low alarms (with relay) I I I I I S7 2 high and low alarms explosion-proof housing ( II2G ATEX ExdIICT6) I I I I I I Code Options I I I I I I Z1 Damping system (essential for gas flow) I I I I I I Z2 High temperature shield I I I I I I Z3 Degreasing and specific packaging for oxygen I I I I I I Z4 Accuracy class 1.6 (liquids within viscosity limits) I I I I I I Z5 Intrinsic safety for codes T and/or S I I I I I I Z6 Special scale I I I I I I Z7 IS power supply + retransmission I I I I I I Z9 Epoxy painted indicator housing I I I I I I Z10 stainless steel indicator housing 250-25- C1- M8- T4- S3- Z1-Z6

Flow meter Technical data Sheet LIMITS CERTIFICATES Of INDIVIDUAL CALIBRATION BNM 2% or 1.6% VDI-VDE: Gas : 0,5 l/h to 55 m 3 /h Liquids : 0.1 l/h to 45 m 3 /h Standard certificate 2%: Gas : 0,5 l/h to 300 m 3 /h Liquids : 0.1 l/h to 100 m 3 /h Models PTFE: 3% TECHNICAL DATA FOR ESTIMATE/ORDER - Nature of the measured fluid (standard, group of dangerosity), - Minimum Flow and desired maximum, - Density, - Viscosity in the operating conditions, - Temperature of service of the measured fluid, - Operating Pressure of the fluid. Information required for quote or order: - Fluid type to be measured. - Maximum and minimum flow rate required. - Specific gravity and viscosity at operating conditions. - Normal working temperature of fluid to be measured. - Maximum temperature of fluid to be measured. - Normal pressure of fluid to be measured. - Maximum pressure of fluid to be measured. - Scale flow units M3/hr or litres per min Installation and maintenance Make sure the Rotameter is positioned as upright as possible and fluid flow is upwards. Keep the inside of the instrument in a good clean state. INSTALLATION To refer to the note of installation, use and maintenance (N 50466-088). Precautions to be taken: To ensure a verticality of the flowmeter as perfect as possible. To maintain the interior of the apparatus in good condition of cleanliness (especially in the case of fluid likely to create deposits). To envisage a minimal distance from 200mm of the apparatus to any magnetic source as well as any valve or bends (see opposite). SPARE PARTS - float and butted, - cap equipped, - graduated dial During the ordering of replacement, it is of primary importance to specify the job number of the apparatus to be repaired before giving reference of any spare part. Houdec Instrument S.A.S. Z.A. de la Tour ABREST France Tel: +33 (0)4.70.59.81.81. Fax: +33 (0)4.70.59.96.37. Email : contact@houdec.com Page 8 www.houdec.com copyright information