MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN. Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION

Similar documents
GALATEA DOMUS. Dal 1901 COD

Parts and Service Manual

MOD. i300 i500. Pagina 1/1. All our products are in accordance with CEE rules: 89/392/CEE 91/368/CEE 93/44/CEE 93/68/CEE 73/23

MITICA. Dal 1901 COD

B2009 compact. Dal 1901 COD

Bravo. Troubleshooting Guide

MATRIX 2 - COD REV.00

B2009 compact. Dal 1901 COD

MATRIX 2 - COD REV.02

B COD REV.02

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for GRANDIMPIANTI

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

SCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E

B2016 / WOODY 2 - COD REV.03

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

vending machine [CINO EC PRO] spare parts manual Latest Update 10/01/2014 Manual PDF Generated on :47

Using the Model 1500 Portable Chilled Mirror Hygrometer

The i500 Series Professional Steam Products

PARTS MANUAL Rev 1.00B DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA FAX

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

SPARE PARTS LIST TPC A P - TPC VA P

Laboratory Freeze Dryer CRYODOS

Service part catalogue

Professional sterilization systems

Water Distiller Service Manual

FCHRT. Wash arm Rinse arm Tank HR. Rinse E-HR-HRT. Rinse aid injector Control box with electronic printed circuit Detergent dispenser

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

HWD-2110 Hot Water Dispenser

2 - Hood DESCRIPTION CABLE HOLDER PG16 WITH HOLE PLUG FOR DOOR (BR-BC-FC) SLIDING WASHER TIE ROD FC

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

BUNN TECHNICAL TRAINING ICB

SpeedClave Steam Sterilizers

Spare parts list. Ref: LPTB02764 Model: FLOOR WASHER PT80 BT55+CB+BAT NE/GR

Global-Tek (Singapore) Pte Ltd

HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine.

E32 CONVECTION OVEN SERVICE MANUAL -1- Revision 1/F3508

Parts Manual Manuel de pièces

TABLE TOP - STEAM STERILIZER Dental & Hospital Application

Parts Manual Manuel de pièces

Parts Manual Manuel de pièces

Granule Gastro/Combi

Service part catalogue SelfCooking Center 102 validity: 10/2008

Parts Manual. Counter Type Electric Convection Steamer. Series: SteamCraft Models 21CET East 179 th Street Cleveland, Ohio 44110

E32 CONVECTION OVEN SERVICE MANUAL

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

Washer-Extractor. Parts. Refer to Page 4 for Model Identification. Part No. D1662

Installation Manual BCS 1000/1500

Spare parts list. Ref: LPTB01858 Model: FLOOR WASHER CT71 XP70 GR/VE

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

BRAVO AUTOCLAVES. Installation Notes. BRAVO 1 Quick Start Guide SD-402 Rev. 1.0 Copyright 2012 SciCan Ltd. All rights reserved

E25 CONVECTION OVEN E25MS CONVECTION OVEN SERVICE MANUAL

COLIBRI' 5 CONTENITORI - Z ESPRESSO INSTANT VOLT - 50 HZ

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

- 12 VDC. HHE M - 12 VDC.

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Appliance Bottom Model :97100 DE 4002 Steam Cleaner (Chemical-Free)

Barrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR18P_

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Spare parts list. Ref: LPTB02702 Model: FLOOR WASHER CT30 B45+BAT GR/VE JP/USA

Parts Manual Manuel de pièces

Spare parts list. Ref: LPTB02916 Model: FLOOR WASHER CT15 B35R+BAT CK GR/VE

BD 14/4 AUTOMATIC SCRUBBER MODEL NO: 99414

Liberty-Classic. Operator s Manual

Parts Manual Manuel de pièces

COMPUTERIZED UNIT FOR RECOVERY, RECYCLING, VACUUM, CHARGE AND FLUSHING. User s manual ENGLISH

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI

NC SERIES. Horizontal Steam Sterilizers

Beck. The differential pressure transmitter for air

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Orbis Battery Scrubber OBS38130

VS LD series vertical steam sterilizers

Fountain Classic. Installation and Owner s Manual. Page 16

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

Parts Manual Manuel de pièces

TECHNICAL INSTRUCTIONS

Harvey Chemiclave EC Series Sterilizers

Hydrogen Generator Model HPNM 1. Instruction manual. 166 Keystone Drive Montgomeryville, PA Phone: Fax:

Spare parts list. Ref: LPTB02680 Model: FLOOR WASHER CT80 BT60 GR/VE

SERVICE MANUAL C24EO SERIES ELECTRIC COUNTERTOP STEAMERS - NOTICE - C24EO5

1901 COD REV.08

CM24T, CM24P Coffee Systems

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

monty 4200 Truck Tire Changer Spare Parts list

Parts Manual Manuel de pièces

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Parts Manual Manuel de pièces

Spare parts list. Ref: LPTB01856 Model: FLOOR WASHER CT71 BT55 GR/VE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for MIWE

E32M CONVECTION OVEN SERVICE MANUAL. Revision 1/F

MODEL CMA-130VL PARTS MANUAL Rev 1.00

PRE AND POST VACUUM CLASS B AUTOCLAVE

CATALOG OF REPLACEMENT PARTS

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

Transcription:

MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 1

SUMMARY 1. ACCESS TO THE MENU WITH PASSWORD... 3 1.0 LOGO... 3 1.1 SERIAL NUMBER... 4 1.2 SW VERSION... 4 1.3 CALIBRATION... 5 1.3.1 CHAMBER PRESSURE... 5 1.3.2 T1 CHAMBER TEMPERATURE PROBE... 6 1.3.3 T2 CHAMBER- TEMPERATUREPROBE... 6 1.3.4 T3 VAPORIZER... 7 1.3.5 T4 BODY... 7 1.3.6 T5 RESISTANCE... 8 1.3.7 T6 RADIATOR... 8 1.3.8 CONDUCTIVITY METER... 9 1.4 INCREASE BAR... 9 1.5 TIMED REFILLING... 10 1.6 VACUUM MAX... 10 1.7 VACUUM DRY... 11 1.8 VAPORIZER TEMPERATURE... 11 1.9 IRON TEMPERATURE CHAMBER 121... 11 1.10 IRON TEMPERATURE CHAMBER 134... 12 1.11 IRON TEMPERATURE DRYING PHASE... 13 1.12 EXTERNAL RESISTANCE TEMPERATURE... 13 1.13 RADIATOR TEMPERATURE... 14 1.14 CHECK ACTUATORS... 14 3 FUSES SCHEME... 16 4 TECHNICAL EQUIPMENT... 16 5 CALIBRATION AND ALIGNMENT... 17 5.0 COLD PROBES ALIGNMENT... 18 5.1 PROBES ALIGNMENT ON TEMPERATURE... 19 6 CALIBRATION... 20 7 RESET COUNTERS... 20 8 SPARE PARTS... 21 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 2

1. ACCESS TO THE MENU WITH PASSWORD PASSWORD 0 0 0 0 Warning! Menu without security! For authorized technician only.. SETTINGS CONFIGURATIONS Contact the Manufacturer for access to the password. We recommend the extreme confidentiality of the same! After entering the password hold START until the display turns on. Press START and the following screen will open 1.0 LOGO LOGO SERIAL NUMBER SW VERSION CALIBRATION INCREASE BAR FILLING Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 3

We do not recommend change the logo, but only to display it. LOGO S E R E N A O N L Y B C Y C L E 1.1 SERIAL NUMBER LOGO SERIAL NUMBER SW VERSION CALIBRATION INCREASE BAR FILLING We do not recommend change the serial number. SERIAL NUMBER 0 0 0 0 0 1 1.2 SW VERSION LOGO SERIAL NUMBER SW VERSION CALIBRATION INCREASE BAR FILLING Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 4

We do not recommend change the SW version. SW VERSION 1.00 1.3 CALIBRATION Warning! Before proceeding to calibration, the machine must be completely cold and preheating must be switched off! LOGO SERIAL NUMBER The following screen will appear SW VERSION CALIBRATION INCREASE BAR FILLING CHAMBER PR. T1 CHAMBER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE By using a certified instrument, adjust the calibration so that the data on the display corresponds to the test instrument. 1.3.1 CHAMBER PRESSURE CHAMBER PR. -004 mbar 1000 mbar Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 5

1.3.2 T1 CHAMBER TEMPERATURE PROBE CHAMBER PR. T1 CHAMBER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE T1 CHAMBER +0.2 C 047.1 C To proceed to the alignment of the sensors T1 and T2, see pg. 16. 1.3.3 T2 CHAMBER- TEMPERATUREPROBE PR.CHAMBER T1 CHAMBER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE T2 CHAMBER +0.2 C 045.9 C Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 6

1.3.4 T3 VAPORIZER PR. CHAMBER T1 CHAMBER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE T3 VAPORIZER +0.9 c +028.2 C 1.3.5 T4 BODY CHAMBER PR. T1 CHAMBER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE T4 BODY +0.3 C 052.7 C Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 7

1.3.6 T5 RESISTANCE PR. CHAMBER T1 CHAMBER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE T5 RESISTANCE +0.6 C 048.8 C 1.3.7 T6 RADIATOR T1 CHAMBER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE T6 RADIATOR T6 RADIATOR +0.1 C 025.9 C Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 8

1.3.8 CONDUCTIVITY METER T2 CHAMBER T3 VAPORIZER T4 BODY T5 RESISTANCE T6 RADIATOR CONDUCTIVITY METER Warning! By a certified instrument verify the quality of water in the tank. Take a small amount of water from the blue grasp and proceed with the verification. THE FIRST THREE NUMBERS are used for calibration. Act with up / down arrow to change so that the other three numbers correspond to the value found with the certificated instrument. Values are expressed in µs. CONDUCTIVITY METER 000 012 micro 1.4 INCREASE BAR LOGO SERIAL NUMBER SW VERSION CALIBRATION INCREASE BAR REFILLING It detects the pressure (P) during vacuum phases. INCREASE BAR 1300 mbar Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 9

1.5 TIMED REFILLING SERIAL NUMBER SW VERSION CALIBRATION INCREASE BAR TIMED REFILLING TIMED REFILLING 090 s ONLY IN THE MANUAL REFILLING:The value indicates the seconds that remains active the pump for filling water clean. To change the values act on up / down arrow. 1.6 VACUUM MAX SW VERSION CALIBRATION INCREASE BAR TIMED REFILLING VACUUM MAX It is the max depression that the sterilizer must achieve in the vacuum phases. It is also the point of alarm in case the vacuum does not occur. VACUUM MAX 0250 mbar Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 10

1.7 VACUUM DRY CALIBRATION INCREASE BAR TIMED REFILLING VACUUM MAX VACUUM DRY The values (D) indicate the range in which the bacteriological filter is activated VACUUM DRY MIN 0240 mbar MAX 0400 mbar 1.8 VAPORIZER TEMPERATURE TIMED REFILLING VACUUM MAX VACUUM DRY VAPORIZER TEMPERATURE The following screen will appear: The values indicate the range in which occurs the injection of water that becomes steam. VAPORIZER TEMPERATURE MIN 150 C MAX 160 C 1.9 IRON TEMPERATURE CHAMBER 121 The values indicate he temperature during all the phases EXCLUDED THE DRY, that is the DRYING PHASE. Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 11

VACUUM MAX VACUUM DRY VAPORIZER TIMED IRON TEMPERATURECHAMBER 121 The values indicate the range in which the resistance tries to maintain the temperature of the metal The following screen will appear. IRON TEMPERATURE CHAMBER 121 MIN 110 C MAX 117 C 1.10 IRON TEMPERATURE CHAMBER 134 The values indicate the temperature during all the phases EXCLUDED THE DRY, hat is the DRYING PHASE. VACUUM MAX VACUUM DRY VAPORIZER TEMPERATURE IRON TEMPERATUE CHAMBER 134 IRON TEMPERATURE CHAMBER 134 MIN 132 C MAX 138 C The values indicate the range in which the resistance tries to maintain the temperature of the metal Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 12

1.11 IRON TEMPERATURE DRYING PHASE IRON TEMPERATURE CHAMBER 121 IRON TEMPERATURE CHAMBER 134 IRON TEMPERATURE DRYING PHASE IRON TEMPERATURE DRYING PHASE 115 C The value indicates the temperature ONLY during the DRYING phase. 1.12 EXTERNAL RESISTANCE TEMPERATURE IRON TEMPERATURE CHAMBER 121 IRON TEMPERATURE CHAMBER 134 IRON TEMPERATURE DRYING PHASE EXTERNAL RESISTANCE TEMEPRATURE EXTERNALE RESISTANCE TEMPERATURE MIN 140 C MAX 145 C The values indicate the range within which the resistance band is still active. Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 13

1.13 RADIATOR TEMPERATURE IRON TEMPERATURE DRYING PHASE EXTERNAL RESISTANCE TEMPERATURE RADIATOR TEMEPRATURE RADIATOR TEMPERATURE MIN 080 C MAX 085 C The values indicate the range of the temperature of the drain water 1.14 CHECK ACTUATORS IRON TEMPERATURE DRYING PHASE EXTERNAL RESISTANCE TEMPERATURE RADIATOR TEMPERATURE CHECK ACTUATORS CHECK A E Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 14

PRESS START to verify the actuators 2 CHECK ACTUATOR: A => clean water above the minimum level B => clean water above the maximum level C => dirty water tank full E => open door D => door approached F => closed door EV VAC => 3-way electro valve EV LOAD => vaporizer pump EV DSCH => water drain electro valve EV VAP => not connected EV BYPS => bypass electro valve EV FLT => bacteriological filter electro valve EV RETE (NETWORK) => purifier electro valve VENT => condenser fan P. VAC => vacuum pump P. LOAD => charging pump clean water tank R. CHAM => resistance chamber R.VAP => vaporizer resistance CLOSE DOOR => the engine is in the closed position and the micro are activated OPEN DOOR => it opens and closes the door without considering the pressure. Warning! Before opening the door verify that the pressure of the chamber is under vacuum or ambient pressure. IMPORTANT NOTE: do not hold START when you do NOT hear the engine noise (ENGINE UNPROTECTED). If you are unable to open the door in any way, proceed as follows: SETTINGS-> CONFIGURATION-> PASSWORD -> CHECK ACTUATOR -> OPEN DOOR -> START press the button and release immediately when open the door! In the process disappears F and appear the E. Release the button just disappears the F and opens the door. Do not hold pressed the button when appears the E! Otherwise, the motor of the door BURNS (menu without protection!). Use this procedure to open the door in case of EMERGENCY! MENU WITHOUT PROTECTION! Danger of burning the motor of the door! Press ESC to exit and return to the main menu Warning! If the controls do not respond properly, it is necessary to check the two fuses alongside the electronic card. The correct positioning of the fuses is marked by a small noise of joints. Small vibrations of the writings on the display indicate that there are anomalies in some component. Water consumption: 1 lt every 2200 cycles -> 0,45 cc for 1 cycle Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 15

3 FUSES SCHEME T1: Transformer F1 (250V T3,15A 5X20): It protects the power P. load, P. Vacuum, Fan, E.V. system, E.V. bacteriological filter, E.V. by pass, E.V. vaporizer, E.V. drainage, E.V. load vaporizer pump, E.V. vacuum pump F2 (250V T3,15A 5X20): It protects the power P. load, P. Vacuum, Fan, E.V. system, E.V. bacteriological filter, E.V. by pass, E.V. vaporizer, E.V. drainage, E.V. load vaporizer pump, E.V. vacuum pump F3 (250V T500mA 5X20): It protects the power of the display and the SD card low-voltage components BT: Battery (VARTA CR2032 3Vdc) 4 TECHNICAL EQUIPMENT MINIMUM EQUIPMENT THAT THE TECHNICIAN MUST HAVE AT DISPOSAL FOR THE CALIBRATION: CERTIFIED THERMOMETER WITH PROBE NO MORE THAN 3.2 mm INSTRUMENT FOR MEASURING THE ENVIRONMENTAL PRESSURE INSTRUMENT FOR MEASURING THE QUALITY 'OF WATER TESTER TO VERIFY THE CONSUMPTION TESTER TO CHECK THE SHORT CIRCUITS AND RESISTANCES ALWAYS KEEP AN ORIGINAL PACKING AVAILABLE FOR EVENTUAL SHIPMENT OF THE STERILIZER Note: All instruments must have the calibration certificate not expired! Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 16

5 CALIBRATION AND ALIGNMENT OPTIONS ->OPENING DOOR -> START OPENING DOOR START Once pressed START, use the arrows UP / DOWN to VISUALIZE THE TEMPERATURE T1 c Tv c Tr c Pr mb. Volt T2 c Tm c Tc c Vo im. Micron A DF Press INFO button to visualize the technician data with the door closed T1 chamber probe temperature Tv vaporizer probe temperature Tr chamber resistance temperature Pr chamber mb pressure T2 chamber probe temperature Tm chamber metal temperature Tc condenser temperature Vo water quantity volume Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 17

The data shown in the first line (eg +1.1 C) corresponds to the delta T of Calibration. The data shown in the second row (eg 082.5 C) corresponds to the temperature detected at that time. 5.0 COLD PROBES ALIGNMENT To align the probes temperatures, proceed as follow: 1. Remove the outer casing 2. Unscrew the cap of ¼ placed on the top of the sterilization chamber 3. Introduce a certified thermometer 4. Start a 134 universal sterilization cycle 5. Wait until the maintenance phase is reached and the temperature has stabilized 6. About half of the PPH phase, press the info button to view the temperatures T1 and T2... 7. Record the temperature of the certified thermometer of T1 and T2 Example: CERTIFIED THERMOMETER SHOWS 134.8 - T1 and T2 SHOWS 134.5 8. At the end of the sterilization cycle, go to the SETUP menu and provide the CALIBRATION. As in the example T1 should be increased of +5 and T2 of +3 9. At this point, the probes should be perfectly aligned 10. Make a further test cycle to ensure that the alignment is done properly. Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 18

5.1 PROBES ALIGNMENT ON TEMPERATURE a) Start the sterilization cycle at 134 PRIONE b) In the middle of the sterilization phase (STR), proceed as follows: - Press and hold INFO. Within 5 seconds after you pressed INFO, press and release at least 5 times, pressing UP (UP ARROW). The menu T1 appears. - From now on, whenever you press INFO, it enters the pages T1-T2-INFO - To return to the usual mode, press and hold INFO for more than 5 seconds. c) At a pressure of 3200-3300 mbar, align the temperature to 135.5 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 19

6 CALIBRATION SETTINGS -> CONFIGURATIONS -> PASSWORD (hold START for 5 seconds till the menu appears) - >CALIBRATION Proceed with the calibration using UP / DOWN buttons Press ESC to confirm LOGO SERIAL NUMBER SOFTWARE VERSION CALIBRATION INCREASE BAR TEMP. REFILLING. VACUUM MAX VACUUM DRY VAP. TEMPERATURE. IRON CHAMBER TEMP. 121 IRON CHAMBER TEMP 134 IRON TEMP. DRYING PHASE TEMP.EXT. RESISTANCE RADIATOR TEMP. ACTUATORS CHECK LOGO it is possible to change the pre-existing logo SERIAL NUMBER it is the serial number given to the machine SOFTWARE VERSION it is assigned by the provider and identifies a type of software installed CALIBRATION the most important calibrations are PR - T1, T2 and μs INCREASE BAR it is the maximum pressure during the vacuum peaks TIMER FILLING Min 000s Max 180s It is the time in which the filling clean water pump is primed. MAX VACUUM (0300mb) It is the maximum vacuum that the machine reaches more an x time. If does not go under it the machine goes into alarm DRY VACUUM min 0500mb max 0900mb vacuum during drying phase When it reaches the 0500mb it opens the valve of the bacteriological filter till 0900mb VAPORIZER TEMPERATURE min 140 C, max 150 C The vaporizer is turned on until the beginning of sterilization. The pump that will produce steam injects water between the two temperatures established. 121 CHAMBER IRON TEMPERATURE min 120 C, max 125 C max It is the metal temperature of the chamber during the 121 cycle 134 CHAMBER IRON TEMPERATURE min 132 C, max 138 C max It is the metal temperature of the chamber during the 134 cycle IRON TEMPERATURE DRYING PHASE It is the metal temperature of the chamber during the drying phase115 EXTERNAL RESISTANCE TEMPERATURE min. 140 C, max 145 C It is the maximum temperature that the resistance can reach RADIATOR TEMPERATURE min. 080 C, max 085 C It is the maximum temperature for condensing the steam The values shown are purely indicative and subject to change. Before the amendment contact the manufacturer for updated data 7 RESET COUNTERS The machine is equipped with counters that indicate the time when is important to change some details, such as the door gasket and the bacteriological filter. Once proceeded with the replacement of spare parts, it is important to reset the counter to zero by performing the following operation -> MAINTENANCE: - Position on the counter - Simultaneously press the down and up arrow for a few seconds until it resets Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 20

8 SPARE PARTS 5189 ELECTRONIC POWER BOARD ASSEMBLY Nr. Cod. Description Q.ty 1 5359 ELECTRIC BOX 1 2 1420 SPACER M3X5 5 3 3645 SCREW M5X10 TBCE 5 3 0900 NUT M5 5 3 2207 SPACER M3X8 5 3 3665 SPACER M3X12 5 3 2912 SCREW M3X6 5 4 3645 SCREW M5X10 1 5 0268 CROSS CABLE 1 6 5169 DOOR AND WATER WIRING 7 5172 ACTUATOR AMPI8 WIRING 8 5171 ACTUATOR AMPI6 WIRING 9 5023 ELECTR. POWER BOARD 1 10 5379 F3 FUSE T500mA5x20 1 11 5380 F1 F2 FUSE T3,15 5X20 2 12 5279 BATTERY CR2032 3Vdc 1 1 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 21

5081/5082 18/23lt. PHASE 1 Nr. Cod. Description Q.ty 1 1067 BACTERIOLOGICAL FILTER 1 2 5335 F JUNCTION BLACK 1 3 5334 F JUNCTION WITE 2 4 5221 DOOR COVER 5 5222 INSIDE COVER 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 22

5081/5082 18/23lt. PHASE 1 Nr. Cod. Description Q.ty 1 5158 DOOR MICROSWITCH 1 2 5025 INOX CHAMBER 18lt. 1 2 5026 INOX CHAMBER 23lt. 1 3 5123 T1-T2 PT1000 PROBE 1 4 5055 SAFETY VALVE 2,5bar 1 5 1352 PLUG M 1/4 2 6 3245 L CONNECTION M 6/4 1/4 2 7 0449 CONNECTION M 6/4 1/4 1 8 0867 CROSS CONNECTION MF 1/4 9 0911 CONNECTION M 6/4 1/4 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 23

5081/5082 18/23lt. PHASE 1 Nr. Cod. Description Q.ty 1 5060 ALLUMINIUM BELT 23lt. 1 1 5059 ALLUMINIUM BELT 18lt. 1 2 5093 HEATER THERMOSTAT 1 3 5089 HEATER 1 4 5235 HEATING PROBE PT1000 1 5 5224 COVER CHAMBER 18lt. 1 5 5225 COVER CHAMBER 23lt. 1 6 5118 PT1000 PROBE 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 24

5081/5082 18/23lt. PHASE 1 Nr. Cod. Description Q.ty 1 5027 MICROSWITCH UNIT 1 2 5028 ELECTRIC MOTOR UNIT 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 25

5197 DOOR ASSEMBLY Nr. Cod. Description Q.ty Nr. Cod. Description Q.ty 1 5037 HINGE PIVOT 2 9 5029 CAST DOOR 1 2 5032 NUT M6 1 10 5036 HINGE FLANGE 2 3 1557 WASHER Ø6X18 1 11 5038 SCREW VTE 8X65 UNI 5737 ZB 4 3684 SCREW TSP M5X10 1 12 5035 DOOR BLOCK 2 5 3015 WASHER Ø10.5X20X0.8 4 13 5031 INOX SHELL DOOR 1 6 5041 BRACKET FOR STUD 1 14 5042 RING FOR STUD 1 7 5043 SCREW M5X25 1 15 5030 SILICON GASKET 1 8 2013 WASHER Ø5X15X1.2 1 16 5040 LARGEST STUD 1 2 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 26

5198 SD CARD AND PRINT CABLE ASSEMBLY Nr. Cod. Description Q.ty 1 5203 CONTROL BRACKET 1 2 3322 SCREW M3X10 4 3 1569 WASHER Ø3 4 4 1831 SCREW M3X16 2 5 2207 SPACER M3X8 4 6 1420 SPACER M3X6 6 7 5202 POWER CABLES 1 8 5170 PRINTER LABELLER WIRING 9 0538 GREEN SWITCH 1 10 5212 SD CARD BOARD 1 11 5165 SD CARD WIRING 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 27

5186 TRASNDUCER ASSEMBLY Nr. Cod. Description Q.ty 1 5187 TRANSDUCER SUPPORT 2 5125 TRANSDUCER 18/23 1 3 0519 COPPER WASHER ¼ 2 4 0449 CONNECTION F 6/4-1/4 1 5 5144 TRANSDUCER CABLE 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 28

5151 USED WATER TANK ASSEMBLY Nr. Cod. Description Q.ty 1 3655 PLASTIC TANK 1 2 4233 LEVEL FLOAT PROBE 1 3 3686 HOSE 8 1/8 3 4 4354 CONNECTION INOX 1/8 1 5 3687 TANK COVER 1 6 0302 SPRING BLOCK 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 29

5149 FILL WATER TANK ASSEMBLY Nr. Cod. Description Q.ty 1 3655 PLASTIC TANK 1 2 3907 LEVEL FLOAT PROBE 1 3 5150 TEFLON HOSE 6X4X100 4 5302 L CONNECTION 6-1/8 1 5 4354 CONNECTION INOX 1/8 6 3686 HOSE 8 1/8 2 7 3687 TANK COVER 1 8 0302 SPRING BLOCK 1 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 30

5244 WATER DRAIN HOSE 5245 FILL WATER HOSE 5364 EMERGENCY FILL WATER HOSE Nr. Cod. Description Q.ty 1 5364 EMERGENCY FILL WATER HOSE 2 5366 NUT 8/6-1/8 1 3 5345 TRASPARENT SILICON HOSE 1 4 0048 FUNNEL 1 5 5245 FILL WATER HOSE 1 6 5361 TRASPARENT SILICON HOSE 1 7 5336 QUICK CONNECTION Ø8mm 1 8 5244 WATER DRAIN HOSE 1 9 5360 RED SILICON HOSE 1 10 5336 QUICK CONNECTION Ø8mm 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 31

5363 DISPLAY ASSEMBLY Nr. Cod. Description Q.ty 1 5201 DISPLAY 1 2 5223 FRONT COVER 1 3 2473 SCREW 3.9X9.5 TSP 1 4 5206 DISPLAY WIRING 1 5 5308 DISPLAY PROTECTION 1 6 5103 KEYBOARD 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 32

5177 STEAM GENERATOR AND VOLUMETRIC COUNTER ASSEMBLY Nr. Cod. Description Q.ty Nr. Cod. Description Q.ty 1 5152 STEAM GENERATOR 1 12 2255 CLAMP 160X2,5 2 2 5367 FIBER GLASS FELT 1 13 5057 T CONNECTION 1 3 5093 220 C THERMOSTAT 1 14 5174 STEAM GENERATOR SUPPORT 1 4 4297 N.C. SOLENOID VALVE 1/8 1 15 4994 PT1000 PROBE 1 5 0109 CLAMP 2 16 5347 RED SILICON HOSE Ø7X13 L=100 6 4926 VIBROPUMP 1 17 5348 TEFLON HOSE Ø6X8 L=30 1 7 4927 PUMP SUPPORT 1 18 4744 SILICON HOSE Ø5X8 L=80 1 8 5175 SILICON HOSE Ø4X6X400mm 1 19 5345 SILICON HOSE Ø5X8 L=250 1 9 2948 ONE WAY VALVE 1 20 3998 VOLUMETRIC COUNTER 1 10 4290 SPRING CLAMP 4 21 5412 L CONNECTION FOR PUMP 1 11 1484 WATER FILTER Ø6 1 22 5166 VOLUMETRIC COUNTER WIRES 1 23 5168 STEAM GENERATOR WIRES 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 33

5333 COIL 18lt. ASSEMBLY Nr. Cod. Description Q.ty 1 3653 SCREW 4X16 TSP 4 2 5326 COIL SUPPORT 1 3 4360 RADIATOR 1 4 0793 NUT M4 4 5 4361 FAN 18LT 1 6 0139 SCREW 3,9X13 TCI 4 7 4994 PT1000 PROBE 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 34

5191 COIL 23lt. ASSEMBLY Nr. Cod. Description Q.ty 1 3653 SCREW 5X20 TSEI 4 2 4360 RADIATOR 1 3 5192 FAN 23LT. 1 4 0139 SCREW 3,9X13 TCI 4 5 5195 COIL SUPPORT 1 6 4994 PT1000 PROBE 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 35

5181 SOLENOIDS VALVES ASSEMBLY Nr. Cod. Description Q.ty Nr. Cod. Description Q.ty 1 5182 SOLENOIDS VALVES SUPPORT 1 10 3245 L CONNECTION 6/4-1/4 1 2 3028 N.C. SOLENOID VALVE 1/8 3 11 TEFLON HOSE 6X8 L=170 1 3 3821 L CONNECTION HOSE 1/8 3 12 3024 L CONNECTION 1/8 2 4 5351 SILICON HOSE 8X5 L=350 1 13 5183 SILICON HOSE 7X13 L=260 1 5 TEFLON HOSE 6X4 1 14 5411 T CONNECTION 1/8 1 7 SILICON HOSE 7X13 1 15 5193 SILICON HOSE 7X13 L=230 1 8 SILICON HOSE 7X13 1 16 1483 CONNECTION HOSE 1/8 2 9 3246 3 WAY SOLENOID VALVE 1 17 2948 ONE WAY VALVE 1 18 5017 L CONNECTION HOSE 1/4 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 36

5154 FILL WATER PUMP ASSEMBLY Nr. Cod. Description Q.ty Nr. Cod. Description Q.ty 1 5057 T CONNECTION 1 7 5062 WATER CONDUCTIVITY 1 2 4290 METAL CLAMP SPRING 3 8 5321 CENTRAL BRIDGE 1 3 1484 WATER FILTER 1 9 5325 TANK SUPPORT 1 4 0715 VIBRO-PUMP 1 10 2256 MAMMUT FASTON 12 PLACE 1 5 1483 1/8 CONNECTION 1 11 5389 SILICON HOSE 7X13 L=255 1 6 3677 RUBBER ANTI-VIBRATION 2 12 5346 SILICON HOSE 7X13 L=55 1 13 5164 WATER CONDUCTIVITY WIRE 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 37

5305 VACUUM PUMP 23lt. ASSEMBLY Nr. Cod. Description Q.ty 1 5180 VACUUM PUMP SUPPORT 1 2 5179 RED SILICON HOSE L=500mm 3 5237 VACUUM PUMP 23LT. 1 4 5306 VACUUM PUMP PROTECTION 5 5264 WATER FILTER GROUP 1 6 5346 RED SILICON HOSE L=50mm 2 7 5057 T CONNECTION M 2 8 5349 RED SILICON HOSE L=200mm 9 5418 SILICON HOSE 8x5 L=20mm 2 1 1 1 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 38

5153 18lt. Nr. Cod. Description Q.ty 1 5180 VACUUM PUMP SUPPORT 1 2 5104 VACUUM PUMP 18LT. 1 3 5057 T CONNECTION M 2 4 5264 WATER FILTER GROUP 1 5 5346 RED SILICON HOSE L=50mm 2 Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 39

5104 VACUUM PUMP 18lt. Autoclave SERENA/Manual for technician/rev.01/23.05.12 Pagina 40