Electric Duct Heaters. IDHB & IDHC Series

Similar documents
HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

Electric Duct Heaters

M1 SERIES DUCT HEATERS

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER

Construction Electrical

Duct Heater Product Catalog

Electric Coils. Blower Coils. Product Information

Custom Duct Heaters. Special Applications

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Standard Duct Heaters Open Coil

GreenJet Transfer Fans

Custom Duct Heaters. Special Applications

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH

Bulletin A Brasch Manufacturing Co., Inc.

Plenum Fans. Model HPA. Direct Drive

Series HF custom designed flange and insert heaters.

TABLE OF CONTENTS page 2

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

ULTRA-SAFE Explosion-proof Duct Heaters

Commercial Duct Heaters. Our products do more in a wide range of applications. Expect More.

SINGLE DUCT TERMINAL UNITS

Direct Gas-Fired Make-Up Air

Heatrix Electric Duct Heater HXOB Installation Instructions

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Modular Supply Make-Up Air Unit

ULTRA-SAFE Explosion-proof Duct Heaters

Lynergy Comfort Control SCR Electric Heater Application Guide

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER

Energy Recovery Ventilators

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

SECTION AIR DUCT ACCESSORIES

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

GreenPark. GreenJet Throw Performance

SECTION DUCTWORK

4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available

Chilled Water DOAS Fan Powered Terminal Units

UNIFIED FACILITIES GUIDE SPECIFICATIONS

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Energy Recovery with Cooling and Heating Model ERCH

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Indirect Gas-Fired Make-Up Air

Steam Humidification Light Commercial Applications. Better technology means better business.

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

AG Series Electric Heaters

DACC Health Sciences Building Air Handler Assessment/Study

Direct Gas-Fired Make-Up Air Models DG and DGX

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Gas-Fired Indoor and Outdoor Duct Furnaces

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Your safety and the safety of others are very important.

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Installation Instructions

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Visit our web site at

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

VAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC

INSTALLATION INSTRUCTIONS

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Installation and Maintenance Manual IM 1102

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

HE-B Series Commissioning Report & User Guide

Neptronic Toll Free: TEL: (514) Fax:(514)

Installation Instructions

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015

MANUAL INSTALLATION + SERVICE. Electric Coils. For VAV Terminals. v100 Issue Date: 01/09/ Price Industries Limited. All rights reserved.

ASHRAE JOURNAL ON REHEAT

Installation Instructions

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

catalog CDV Fan-Coil Units High-Performance, Vertical

Installation Instructions

HRV Vertical Unit Ventilators

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

( )

(770) wwww.southgateprocess.com

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Digital Precise Air Control - DPAC

MERIT SERIES Downflow

Installation Instructions

50TM TFF COMBINATION HEATING/COOLING UNITS

Transcription:

Electric Duct Heaters IDHB & IDHC Series May 2014 1

Duct Heaters Greenheck has a complete line of configurable electric duct heaters that are perfectly suited to your HVAC application. Our CAPS configuration tool helps you save time with its industry leading selection speed and information packed submittals. With quick lead times and a proven history of on time shipping, we can ensure that your heater will be available when you need it. Experience the difference by choosing Greenheck duct heaters for your project. Applications Greenheck duct heaters are used in forced air applications to provide dedicated space heat or to supplement existing heating systems. Typical applications are: Space heating Primary heating Secondary and/or auxiliary heating Reheat Multi-zone and VAV systems Replacement Models: IDHB & IDHC Greenheck offers two heater styles: IDHB and IDHC series. All heaters are factory assembled and wired for 50/60 Hertz. Both models feature: Fan interlock Ground lugs Automatic limit switch for primary over temperature protection Manual reset limit switch for secondary over temperature protection Disconnecting contactor Power terminal board Control panel constructed of heavy gauge corrosion resistant steel Control terminal board Left hand offset control box (standard) Control components secured to a raised plate UL 1996 Listed 105 C appliance wire IDHB Series IDHC Series 2

IDHB & IDHC Two frame types are available: Slip in - allows you to slip the heater into the opening in the ductwork. Flange - allows you to bolt into place between two sections of flanged duct. Slip in Flange Double Lip Wrapper Wrapper Terminal or Control Box Heating Elements Terminal or Control Box Heating Elements Why would I choose Greenheck heaters versus other brands? We provide: Bi-directional airflow in horizontally mounted applications Hinged access cover with latch All limit controls are resettable Proven wire rack system provides very low pressure drop and extended element life Zero clearance rating for installations into ducts All components (except the SCR) are mounted inside the control panel IDHB IDHC Voltages/Stages 120/1-480/3 120/1-575/3 Capacity 0.5-39.9 kw 0.5-500 kw Minimum Size 8 x 8 8 x 8 Maximum Size 36 x 36 120 x 144 Controls 1 or 2 stage Pneumatic Stage Step SCR control Vernier SCR (Larger kw) Pneumatic Thermostat Room Room Duct 3

Options/Accessories Control Panel Removable hinged access door with latch (standard) Detailed wiring diagram Configurable with left or right offset Available options: Dust tight construction with gasketed cover and sealed seams Vapor barrier Recess for internally insulated ducts Flush mount configuration 1 - Airflow Switch Fan Interlock switch (standard/ul required) Optional airflow switch senses air pressure across the heater surface closing the electrical switch and allowing the heater to activate. This switch is available with fixed or adjustable set point. 2 - Disconnect Switch A door interlocking disconnect switch is used to prevent the control door from being opened until power to the heater is disconnected. 8 3 - Power Fusing UL and NEC codes require heaters in excess of 48 amps be subdivided into circuits of 48 amps or less. If 48 amps or greater, fusing comes standard. Less than 48 amps, fusing is optional. 7 4 - Terminal Blocks Terminal blocks are standard on all heaters for quick and easy integration with field installed control wiring. 5 - Contactors Disconnecting contactors break all ungrounded lines on UL listed duct heaters and are UL approved for 250,000 cycles. There are two types available: Magnetic - standard for all heaters Mercury - used where silent operation and/or frequent cycling is desired (optional) 4

Options/Accessories 6 - Control Transformer Control transformers are used to provide single point wiring when the control voltage differs from the line voltage. The transformer is available as fused or unfused. 1 2 7 - Capacity Controls Staged Control One to four stages are provided standard. Pneumatic Pneumatic controls allow a pneumatic building control system to operate heaters with up to three stages. An airflow switch is standard with this option. Proportional Controls 6 5 3 Model IDHC is available with the following proportional control options which are compatible with a 0-10Vdc or 4-20mA analog signal from a BMS, Room or Duct T-stat. Electronic Step Controller An electronic step controller provides electronic sequencing control of an electric duct heater up to 12 steps. When interruption of power occurs all stages cycle off. Upon restoration of power the step sequence resumes. SCR (pictured) Solid state relays are used to provide continuous modulation. SCR is the most precise form of heater control. Vernier SCR (Step and SCR) Vernier SCR control combines the benefits of Step and SCR control to provide precise proportional control on heaters in excess of 135 amps. 4 8 - Elements Standard heater elements are 60% Ni grade C wire which exhibit excellent performance in standard applications. Elements are supported with a wire rack system that significantly reduces element sag and pressure drop. Optional features include: 80/20 NiCr, grade A element wire provides superior corrosion resistance in reheat and high humidity applications Derated coils aid in longer element life in single and multi-zone air handler applications 5

Options Pilot Light Pilot lights are installed on the side panel and used to indicate heater conditions as follows: - heater energized - step energized - airflow switch open Available with 24V or 120V control voltages Time Delay Relay A time delay relay provides a delay of 30 to 60 seconds when energizing or de-energizing the circuit controlled. Standard control voltages are 24V through 277V Pressure Electric Switches (PE) A PE switch is used to control the heater with a pneumatic air signal. Requires field adjustment for specific job requirements Thermostat Room stat - Controls heater to maintain adjustable space temperature when heater is used as primary heating method Duct stat - Controls heater to maintain adjustable discharge temperature. This is the preferred method of control for preheat and reheat applications. This option is only available with SCR, Vernier SCR, or Step controller systems. Heater Selection This diagram shows typical information that you will need when selecting a duct heater. Dimensions Width Height Mounting Type Slip-in Flanged Capacity (kw) Given or Calculated 6

Performance Data Minimum Air Velocities WATTS PER SQUARE FOOT, DUCT AREA Static Pressure Drop - inches of water (w.g.) 22,000 20,000 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000.16.14.12.10.08.06.04.02 200 400 BELOW 78 F INLET AIR 600 78 TO 90 F INLET AIR 91 TO 110 F INLET AIR 800 Velocity (fpm) 1,000 Pressure Drop Through Heater 1,200 4 3 2 1 1,400 General A. The minimum airflow through a duct heater is directly related to the inlet air temperature. Consideration must be given to both airflow across the heater and the inlet temperature. B. To calculate the watts per sq. ft. (square foot) of duct area, divide the total watts required by the duct size (Watt density = watts/duct area (ft 2 ). Example: Duct size equal 2 ft. x 3 ft., total watts equal 20,000 watts per sq. ft. 20,000 = 3333 6 C. If airflow in the duct is expressed in FPM, then a direct cross reference can be made by comparing the temperature of the air (as it enters the duct heater) to the kw rating on the table at the rated air velocity. 1. Draw a line horizontally from the watts per sq. ft required to the inlet air temperature being used. 2. From this point of intersection on the inlet temperature line, draw a line down vertically to establish the air velocity. 3. In cases where the velocity is less than that determined from the chart, then the velocity must be increased, the kw required must be reduced, or both must be done. D. In cases where the airflow is expressed in CFM, convert to FPM by dividing the CFM by the duct area. CFM = FPM Duct Area(ft 2 ) 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000 2,200 Air Velocity - FPM 1, 2, 3 and 4 - the number of rows of heater coils. When the number of rows of heater coils is unknown, assume 4. Power Source Voltage Phase Control Type Staged Stepped Proportional Accessories 7

Formula for Calculating Line Currents AMPS = Single Phase AMPS = WATTS LINE VOLTAGE Three Phase WATTS LINE VOLTAGE x 1.73 TO CONVERT kw TO WATTS MULTIPLY kw BY 1,000 Line Voltage Factor Line Voltage x 1.73 208 x 1.73 = 359.8 220 x 1.73 = 380.6 230 x 1.73 = 397.9 240 x 1.73 = 415.2 440 x 1.73 = 761.2 460 x 1.73 = 795.8 480 x 1.73 = 830.4 550 x 1.73 = 951.5 600 x 1.73 = 1038.0 Capacity Calculator (Standard Air Conditions) kw = CFM x 1.08 x T 3414 T = Temperature rise Enjoy Greenheck s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3-5-10-15- or 25-day production cycles, depending upon their complexity. Greenheck s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. Our 3D service allows you to download, at no charge, easy-to-use AutoDesk Revit 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts 8 P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com 00.DMP.1015 R1 6-2014 IW Copyright 2014 Greenheck Fan Corp.