Commander Series Ultra Low NOx Commercial Gas Water Heaters
Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series features a unique down-fired premix power burner that aumatically regulates for optimum combustion and efficiency. Together with a two pass, multiple tube system, the Commander Series achieves excellent thermal efficiencies and meets the most stringent air quality Introducing the Commander Series, a new line of high standards for allowable NOx emissions. efficiency, ultra low NOx water heaters that redefines the standard in commercial gas water heating. Sequence of Operation With advanced features and technologies, the Commander Series provides higher performance levels, enhanced 2 4 The new Commander Series models are perfect for nearly all new or replacement commercial applications, including hotels, apartments, hospitals, restaurants, and office buildings. capabilities, cleaner emissions, and remarkable installation flexibility. Take charge of your commercial water heating demands and increase cusmer satisfaction with the new Commander Series from Bradford White. Highlights Up 82% Thermal Efficiency Smallest footprint of all Ultra Low NOx commercial gas models in its class ( 28.25 inch width) ICON HD Commercial Control System Direct Spark Ignition Initial call for heat initiates blower for a 0 second, air intake pre-purge. Gas valve opens and fuel mixes with intake air as direct spark ignites main burner. Flame signal confirmed. enter the st pass heat exchanger traveling down a single heat exchanger tube. reach a pass collecr and are redirected upwards in multiple, smaller heat exchanger tubes. Thermostat satisfies, gas valve closes, main burner turns off, and blower post-purges for 0 seconds. Two Pass Flue System Down-Fired Premix Power Burner Aumatically adjusts up,000 ft above sea level Atmospheric Vent All models vent atmospherically through Category I venting (B-Vent) Ductable Air Intake Optional Great Installation Flexibility! Ductable Air Intake - Optional (PVC, CPVC, ABS) Top and Side -/2" NPT Water Connections Venting Options Smallest footprint of all Ultra Low NOx commercial gas models in its class ( 28.25 inch width) Optional Side Space Heating Connections Overall shorter height allows for installation where existing venting restricts water heater height Moveable T&P and Drain Valve (left right) Direct vent from an outside wall or through a roof up 75 feet with optional air intake ducting No Dampers or Pressure Switches Top and side -/2" NPT water connections Meets California Ultra Low NOx Requirements T&P and drain valves are moveable (left right) in the field
Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series features a unique down-fired premix power burner that aumatically regulates for optimum combustion and efficiency. Together with a two pass, multiple tube system, the Commander Series achieves excellent thermal efficiencies and meets the most stringent air quality Introducing the Commander Series, a new line of high standards for allowable NOx emissions. efficiency, ultra low NOx water heaters that redefines the standard in commercial gas water heating. Sequence of Operation With advanced features and technologies, the Commander Series provides higher performance levels, enhanced 2 4 The new Commander Series models are perfect for nearly all new or replacement commercial applications, including hotels, apartments, hospitals, restaurants, and office buildings. capabilities, cleaner emissions, and remarkable installation flexibility. Take charge of your commercial water heating demands and increase cusmer satisfaction with the new Commander Series from Bradford White. Highlights Up 82% Thermal Efficiency Smallest footprint of all Ultra Low NOx commercial gas models in its class ( 28.25 inch width) ICON HD Commercial Control System Direct Spark Ignition Initial call for heat initiates blower for a 0 second, air intake pre-purge. Gas valve opens and fuel mixes with intake air as direct spark ignites main burner. Flame signal confirmed. enter the st pass heat exchanger traveling down a single heat exchanger tube. reach a pass collecr and are redirected upwards in multiple, smaller heat exchanger tubes. Thermostat satisfies, gas valve closes, main burner turns off, and blower post-purges for 0 seconds. Two Pass Flue System Down-Fired Premix Power Burner Aumatically adjusts up,000 ft above sea level Atmospheric Vent All models vent atmospherically through Category I venting (B-Vent) Ductable Air Intake Optional Great Installation Flexibility! Ductable Air Intake - Optional (PVC, CPVC, ABS) Top and Side -/2" NPT Water Connections Venting Options Smallest footprint of all Ultra Low NOx commercial gas models in its class ( 28.25 inch width) Optional Side Space Heating Connections Overall shorter height allows for installation where existing venting restricts water heater height Moveable T&P and Drain Valve (left right) Direct vent from an outside wall or through a roof up 75 feet with optional air intake ducting No Dampers or Pressure Switches Top and side -/2" NPT water connections Meets California Ultra Low NOx Requirements T&P and drain valves are moveable (left right) in the field
Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series features a unique down-fired premix power burner that aumatically regulates for optimum combustion and efficiency. Together with a two pass, multiple tube system, the Commander Series achieves excellent thermal efficiencies and meets the most stringent air quality Introducing the Commander Series, a new line of high standards for allowable NOx emissions. efficiency, ultra low NOx water heaters that redefines the standard in commercial gas water heating. Sequence of Operation With advanced features and technologies, the Commander Series provides higher performance levels, enhanced 2 4 The new Commander Series models are perfect for nearly all new or replacement commercial applications, including hotels, apartments, hospitals, restaurants, and office buildings. capabilities, cleaner emissions, and remarkable installation flexibility. Take charge of your commercial water heating demands and increase cusmer satisfaction with the new Commander Series from Bradford White. Highlights Up 82% Thermal Efficiency Smallest footprint of all Ultra Low NOx commercial gas models in its class ( 28.25 inch width) ICON HD Commercial Control System Direct Spark Ignition Initial call for heat initiates blower for a 0 second, air intake pre-purge. Gas valve opens and fuel mixes with intake air as direct spark ignites main burner. Flame signal confirmed. enter the st pass heat exchanger traveling down a single heat exchanger tube. reach a pass collecr and are redirected upwards in multiple, smaller heat exchanger tubes. Thermostat satisfies, gas valve closes, main burner turns off, and blower post-purges for 0 seconds. Two Pass Flue System Down-Fired Premix Power Burner Aumatically adjusts up,000 ft above sea level Atmospheric Vent All models vent atmospherically through Category I venting (B-Vent) Ductable Air Intake Optional Great Installation Flexibility! Ductable Air Intake - Optional (PVC, CPVC, ABS) Top and Side -/2" NPT Water Connections Venting Options Smallest footprint of all Ultra Low NOx commercial gas models in its class ( 28.25 inch width) Optional Side Space Heating Connections Overall shorter height allows for installation where existing venting restricts water heater height Moveable T&P and Drain Valve (left right) Direct vent from an outside wall or through a roof up 75 feet with optional air intake ducting No Dampers or Pressure Switches Top and side -/2" NPT water connections Meets California Ultra Low NOx Requirements T&P and drain valves are moveable (left right) in the field
The Commander Series Exclusive Technologies and Features ICON HD Commercial Control System Features an LCD digital display showing temperature set point and diagnostic codes aid in servicing and troubleshooting User-friendly uchpad and easily viewable data display area Down-Fired Premix Power Burner Proven design with over years of use in the field Self-compensating negative pressure system Aumatically regulates fuel flow when a change in combustion air is detected Optimum combustion and efficiency Aumatically adjusts for altitudes up,000 feet No Dampers or Pressure Switches Hydrojet Sediment Reduction System Helps prevent sediment buildup inside the tank BRADFORD WHITE CORPORATION Two Pass, Multiple Tube Flue System Two Pass, Multiple Tube Heat Exchanger System Submerged Combustion Chamber Minimizes radiant heat loss and improves efficiency Scan the QR code see the Commander Series video!
Standard Features Direct Spark Ignition For improved operational dependability and durability. Integrated Exhaust System New configuration and vent connecr height allow for easy replacement of existing atmospheric vent water heaters. Sanitizing Capability Complies with sanitation capabilities up F (82 C). Facry Installed Hydrojet Sediment Reduction System Cold water inlet sediment reducing device helps prevent sediment build up in the tank. Non-CFC Foam Insulation Covers the sides of tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity. Water Connections Facry installed true dielectric waterway fittings extend water heater life and eases installation. Multiple water connection locations allow for greater installation flexibility. " NPT Side Connections for Space Heating. Zero Inch Clearance Combustibles. Hand Hole Cleanout. NSF Construction Available. T&P Relief Valve Installed. Low Restriction Brass Drain Valve Durable tamper proof design. Ultra Low NOx Construction (4 ng/j NOx emissions) Natural gas models only. CSA Certified Low Lead Content. Specs at a Glance B H A G F K E D J C Model Number UCG-H-25-N UCG-H-99-N UCG-H-270-N UCG-H-99-N UCG-0H-99-N UCG-0H-270-N UCG-0H-99-N Capacity U.S. Gal. 0 0 98 Imp. Gal. 8 8 82 Input Nat. BTU/Hr. Input 25,000 99,999 270,000 99,999 99,999 270,000 99,999 GPH Recovery at Degree Rise* 40 F 0 F 40 F 08 49 5 90 49 5 994 2 97 2 84 97 2 98 88 4 90 274 4 90 284 A Top of Vent 4 4 8 7 7 77 B Vent. Dia. 5 8 8 C Cold Water Inlet For Propane Gas models change suffix "N" "X". Example: UCG-0H-99-X (UCG-0H-99 available in Natural Gas only). Natural gas models comply with the latest Ultra Low NOx requirements (4 ng/j or less). Amp Draw range =.0.8 amps. D T&P 52 /2 52 /2 52 /2 E Hot Water Outlet 55 /2 55 /2 55 /2 F Top of Heater 9 9 9 G Gas 55 55 55 55 H Depth 0 0 0 0 0 0 0 J Width 28 28 28 28 28 28 28 K Cold Water Inlet/Hot Water Outlet 54 54 54 54 Water Dia. Gas Dia. Relief Valve Open Approx. Shipping Weight lbs. 55 55 545 545 2 2 57 Dimensions and specifications subject change without notice in accordance with our policy of continuous product improvement. CMNDRB-0 Committed American Manufacturing, Wholesale Distribution, and Professional Installation. www.bradfordwhite.com