Secure connection system

Similar documents
klik Lighting connection and control catalogue

Lighting, Connection & Control

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

, ,

LPCMPIRM65 & LPCMPIRDSI65

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LPC3BSP65 & LPC3BDP65

Integrated PIR detectors

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Lighting & Controls Motion & Presence Detectors

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBMHS (standard & slim-line PSU)

Tebis application software

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

IP65 High Bay Dual Sense Sensor

Sensors and Detectors

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

IP65 High Bay Dual Sense Sensor

Ceiling PIR HS presence detector. Product Guide. Overview. Features

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

SENSA MRE DDM MR

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Built-in HF Sensor for High Bay

SWITCHLITE MRE DDM ADJ

Direct Dim Microwave Presence/Absence Detector

Tri-level Control Sensor

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

Tri-level Control HF Sensor

False Ceiling HF Sensors

Analogue Dimming Microwave Presence/Absence Detector

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Tri-level Control HF Sensor

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Fixing points M6 (1/4 )

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Premium Version Tri-level Dimming Control

UP 258E11 OPTISENS OFFICE

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Connections, displays and operating elements C D E G H. Installing the control unit

SWITCHLITE MRE SLDM ADJ

Standalone Presence Detectors

Product and Applications Description

Devices for Special Applications

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

MWS3 Ceiling Mount Microwave Occupancy Detector

Uniclass. Epic K4:Y46 (63) X (R5) Vitesse Modular. Reinventing lighting connection systems 2.2. Issue

µdim Microwave Sensors User Manual

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

DALI MSensor 02 Multi-sensor for DALI system

MWS3A-PRM Product Guide

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

EBDSPIR-PRM-LV Product Guide

Tri-level Control HF Sensor

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

FR-A180 FR-A360. Occupancy detector. Use

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

1. Basic safety information 3 2. Proper use 3

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Movement-based energy control

Integrated SensorDIM LED Driver Daylight Monitoring Version

Ceiling Microwave presence/absence detector 12-24V AC/DC

CHALLENGER 66 INDUSTRIAL

Controller - 4 x 1-10 V outputs - BUS/KNX

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI

DALI MSensor 02 Multi-sensor for DALI system

Infrared Wall Mount Occupancy Sensor

ARGUS presence detectors. Move towards energy efficiency

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Daylight harvest function to regulate light output for maintaining required lux level

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

1. Basic safety information 3 2. Proper use 3

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Highlights. SMARTHOME product combinations. Starter Set 4 radiator control for saving energy wirelessly controlled 2013/1.

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

The Power To Supply... All Your Electrical Products

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Detector switch - Dual Tech

Fully addressable lighting control system. Issue

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Passive infrared ceiling sensor

D-Tect 2 GJD300 Quad PIR Movement Detector

Transcription:

klik.system Secure connection system klik.system can be used as a simple stand-alone digital lighting control unit or as part of a more complex building management system for distribution of power and data. The klik.system range of unique plug and play connectors has been enhanced with a choice of products ideal for electrical contractors who want to add digital lighting control solutions to their offer.

Marshalling Boxes 11.30 Luminaire Leads 11.30 Occupancy Sensors 11.31 Conduit Boxes / Surface Connectors 11.31 klik

Occupancy sensors Pluggable standard and digital Our range of occupancy sensors detect infra-red radiation and ambient light levels to provide simple and cost effective means of lighting control. The EEK range of sensors should be mounted in the centre of the group of luminaires to be controlled and the optimum all round coverage is achieved with the unit mounted at a height of 2.5m. The coverage for these sensors at this height is approximately 5m diameter for small movement such as working at a desk, and 7m for larger movements such as walking. 2 3 4 1 The advantages for you Technical data Digital switching capability, up to 24 DSI or DALI ballasts. Automatically detects and conigures to DSI or DALI ballasts. Integral photocell allows for lighting control which can provide energy savings by not operating when suficient natural light levels exist. Wide operating range to suit most commercial applications. Allows overrun of lighting to be customised to installation. Available pre-wired, reduces installation time on site and requirement for non-standard cable. Integral photocell 5-1000 lux Detection: High sensitivity detection up to 5m diameter Motion detection up to 7m diameter Time out adjustment: 2 min - 57 min with remote programmer 1 min - 1 hour with potentiometer Pre-wired cable: 3m 1.5mm 2 Low Smoke Zero Halogen for Relay model 3m 0.75mm 2 Low Smoke Zero Halogen for Digital model

Quick tips 1 Integral Photocell Automatic lighting control which can provide energy savings by not operating when suficient natural light levels exist. 1 110011001110 010110001101 010110010000 011011110110 11001100110 Digital Switching Up to 24 DSI or DALI ballasts. Automatic detection of ballast type. 2 Potentiometers Hidden behind a discreet sliding cover the potentiometers allow limited control of sensors. 2 Detection High sensitivity detection will react to small movements, such as somebody working at a desk. Motion detection will react to larger movements, such as walking. 3 Lux setting via remote Allows set point to be increased or decreased in 100 lux steps on digital light ittings from the EE807 remote programmer. Makes adjustment of photocell set point convenient. 3 EE807 Programming Tool Programming tool is easy to use with 2 memory settings to enable repeatability. 4 Time out adjustment Wide operating range to suit most commercial applications. Allows overrun of lighting to be customised to installation. 4 EE808 Remote Control Comes with a wall mounting bracket for storage and allows room occupant to have control of lighting output.

klik.system The klik.system range of unique plug and play connectors has been enhanced with a choice of products ideal for installations where digital control solutions are utilised. Marshalling box The KLMB marshalling box allows the connection and control of multiple luminaires. The LMB utilises a robust extruded aluminium body: 7 pole, 4, 6, 8, 10, 12 outlet, 16A rated, BS 5733:2010, short-circuit tested: 1500A conditional rating. Luminaire lead The marshalling box is connected to the luminaire via a pre-wired plug and lead, all leads are low smoke zero halogen and are factory connected and tested: 1mm² CSA, 3m and 5m lengths, standards, digital and emergency luminaires, 6A rated, BS 5733:2010, BS EN 61535, short circuit tested: 1500A conditional rating. Description Characteristics Pack Cat. ref. qty 7-Pin Marshalling boxes 4 way 7 pole box 16A 1 KLMB4W single supply wire in, plug out 6 way 7 pole box 16A 1 KLMB6W 8 way 7 pole box 16A 1 KLMB8W KLMB4W 10 way 7 pole box 16A 1 KLMB10W 12 way 7 pole box 16A 1 KLMB12W 7-Pin Marshalling boxes 5 way 7 pole box 16A 1 KLMB5P single supply plug in, plug out 7 way 7 pole box 16A 1 KLMB7P 9 way 7 pole box 16A 1 KLMB9P 11 way 7 pole box 16A 1 KLMB11P Pre-lexed standard luminaire 3m, 1mm², 3core LSOH, 10A 1 KLB/3/1W leads with klik.system plug and pre-sleeved wire ends 5m, 1mm², 3core LSOH, 10A 1 KLB/5/1W with emergency 3m, 1mm², 1 KLJ/3/1W 4core LSOH, 10A KLx/x/1W with emergency 5m, 1mm², 1 KLJ/5/1W 4core LSOH, 10A Pre-lexed digital luminaire 3m, 1mm², 5core LSOH, 10A 1 KLP/3/1W leads with klik.system plug and pre-sleeved wire ends 5m, 1mm², 5core LSOH, 10A 1 KLP/5/1W with emergency 3m, 1mm², 1 KLT/3/1W 6core LSOH, 10A with emergency 5m, 1mm², 1 KLT/5/1W 6core LSOH, 10A Pre-lexed special leads retractive dimming/on/off 1 KLD/5/1-5W with klik.system plug 5m, 1,5mm², 3core LSOH, 16A retractive absence/override 1 KLL/5/1-5W 5m, 1,5mm², 3core, 16A emergency exit 1 KLE/3/1-5W 3m, 1,5mm², 3core, 16A emergency exit 1 KLE/5/1-5W 5m, 1,5mm², 3core, 16A 11.30

klik.system Occupancy sensor The control on klik.system is provided by a range of occupancy sensors. The sensors are available for relay control and digital control. The digital sensors will automatically conigure for DSI and DALI protocols. Sensors can be programmed with the infra-red tool or potentiometers. The sensors can be pre-wired and pluggable directly into the marshalling box, or hardwired into the marshaling box terminals. All cable is low smoke zero halogen: standard relay / digital, detection range 7m, standard: IEC 60669-2-1, rating 16A max, 5-1000 lux photocell. Conduit box and surface connector Hager have developed a 7 pole conduit box / surface connector to allow the easy connection of digital lighting within traditional ixed wire installations. The connector is itted directly to trunking or conduit allowing the luminaire to be connected / disconnected via the pluggable luminaire lead: 7 pole, 16A rated, standards: BS 5733:2010, short circuit tested: 1500A conditional rating. Description Characteristics Pack Cat. ref. qty Occupancy sensors - standard relay sensor complete with 3m lead 1 EEK513P klik complete with 5m lead 1 EEK515P EE815 without cable/plug 1 EE815 - digital relay sensor complete with 3m lead 1 EEK523P complete with 5m lead 1 EEK525P without cable/plug 1 EE816 Occupancy sensors KNX - standard relay sensor complete with 3m lead 1 TKK513P complete with 5m lead 1 TKK515P without cable/plug 1 TCC510S - digital relay sensor complete with 3m lead 1 TKK523P complete with 5m lead 1 TKK525P without cable/plug 1 TCC521 Conduit boxes and connector 1 KLPCR/7 Surface connector KLPCR with 5core 3m 1mm² 1 KLPCR/P/3/1W digital luminaire lead with 6core 3m 1mm² 1 KLPCR/L/3/1W digital emergency luminaire lead with 5core 1m 0.75mm² 1 KLPCR5000 digital luminaire lead with 6core 1m 0.75mm² 1 KLPCR6000 digital emergency luminaire lead 11.31

klik 7 pin Lighting Control Module Lighting Control Module with KlikLink KLCM412W The KLCM allows connection and control of multiple luminaires with four separate channels. Switching Dimming (DSI & DALI) Corridor hold Partition switching Daylight switching & dimming Scene settings Integral emergency test times Reset proiles Light leave offset (channel to channel) Description Cat. ref. 12 Way 4 Channel LCM Plug in, Plug out KLCM412P 13 Way 4 Channel LCM Wire in, Plug out KLCM413W SmartLink ipad App Lighting Control Module Occupancy Sensor klik LCM occupancy sensors come complete with a 5m RJ11 lead and have integrated daylight sensing. Sensing options are selected via the kliklink app (e.g. presence/ absence) KLCM-OS LCM Occupancy Sensor with KlikLink Klik LCM Occupancy Sensor with KlikLink (provided with 5m RJ11 Lead) KLCM-OS Lighting Control Module Switch Drop Lead SELV (Grey) RJ45 to switch (wire-in) lead available in a variety of lengths SELV RJ45 connector (Cables supplied standard with RJ45 plug on both ends) KLO15RJ45G 5m RJ45 SELV Switch Drop Lead 10m RJ45 SELV Switch Drop Lead 15m RJ45 SELV Switch Drop Lead 20m RJ45 SELV Switch Drop Lead 30m RJ45 SELV Switch Drop Lead 40m RJ45 SELV Switch Drop Lead 50m RJ45 SELV Switch Drop Lead KLO5RJ45G KLO10RJ45G KLO15RJ45G KLO20RJ45G KLO30RJ45G KLO40RJ45G KLO50RJ45G Lighting Control Module Switch Drop Lead SELV (Red) RJ45 to RJ45 link lead SELV RJ45 connector (Cables supplied standard with RJ45 plug on both ends) KLO15RJ45R 5m RJ45 SELV Link Lead 10m RJ45 SELV Link Lead 15m RJ45 SELV Link Lead 20m RJ45 SELV Link Lead 30m RJ45 SELV Link Lead 40m RJ45 SELV Link Lead 50m RJ45 SELV Link Lead RJ45 Splitter KLO5RJ45R KLO10RJ45R KLO15RJ45R KLO20RJ45R KLO30RJ45R KLO40RJ45R KLO50RJ45R KLORJ45CON 11.32

Product Standards Product Description klik Product identiication BS number Description klik.system Marshalling Boxes KLMB*W BS 5733:2010 General Requirements for Electrical Accessories. Occupancy Sensor Conduit Box / Surface Connector Luminaire Leads LS0H Flexible Cord EEK* IEC 60669-1, IEC 60669-2-1 KLPCR/7 BS 5733:2010 KLB*, KLJ*, KLP*, KLT* Supplied with luminaire lead BS 5733:2010 BS EN 61535 BS 6500:2000 BS 7211:1998 Switches for household & similar ixed electrical installations Part 2-1 for Electronic switches. General requirements for Luminaire supporting couplers for domestic, light industrial & commercial use. General Requirements for Electrical Accessories. Installation couplers intendend for permanent connection in ixed installations. Flexible cords rated to 300/350V for use with appliances & equipment intended for domestic, ofice & similar environments. klik 11.33

IR Commissioning Remote Control for EE807 Description EE807 LED Use The remote control allows the user to set or modify presence detector settings. When the potentiometer is on auto test it allows single and multiple settings. The SET key is used to send the IR messages to the occupancy sensors. Multiple settings can be stored in Memo 1 and Memo 2 and re-called to set several devices. Single setting Example: reset + The acknowledgment LED blinks during the sending of the IR message. Technical speciication Power supply:1x 3V CR2032 Shelf life of battery: 2½ years Protection index: IP 30 Multiple settings Deine the parameters to be changed and press SET to send. Example: for 25 minutes and corridor use, press 20, 5 and corridor. + + + Settings available In the case of 2 opposite states the green LED denotes ON and red LED denotes OFF (except Presence / Absence). When no function is selected all LED s are OFF. Key Meaning Indication Function Presence Green LED on Presence on (automation mode) Absence Red LED on Absence on (semi automatic mode) Power Up Green LED on The light is automatically switched on for 30 seconds after power up Red LED on During warm up phase, the light output is off Reset LED on To return to factory settings (Lux = 400, time = 20 min, presence on, power up off and cell active) Test LED on To validate the detection area Time LED on To set the time It is possible to add times together e.g. press 2 and 5 for a time value of 7 Day level 1000 Lux LED on To set the value to 1000 Lux Learn LED on To learn the current Lux level Corridor 200 Lux Ofice 400 Lux LED on LED on To set the value to 200 Lux To set the value to 400 Lux Lux + LED on To increase the Lux level (+100) Lux - LED on To decrease the Lux level (-100) Active cell Green LED on The light is continuously measured Passive cell RED LED on The sensor will not switch the light off even if the ambient luminosity is suficient Memo and set Key Meaning Indication Function Press LED is on until a setting is changed To load/unload Memo 1 Long press LED is on for 5s, then will blink until released. After release, the LED goes off in case of setting change To save the current setting as Memo 1 Press LED is on until a setting is changed To load/unload Memo 2 Long press LED is on for 5s, then will blink until released. After release, the LED goes off in case of setting change To save the current setting as Memo 2 Short press (<5s) LED lashes To send an IR message of the current setting Long press (>5s but <10s) only available if no setting active LED blinks until release press To toggle automatic mode on DALI/DSI 11.34

Occupancy Sensors Description LED Use The remote control allows the user to set or modify settings on the presence detectors EEK513P/EE815 and EEK523P and EE816 Each button corresponds to a command. The acknowledgment LED blinks during the sending of the IR message. Technical speciication Power supply:1x 3V CR2032 Shelf life of battery: 3½ years Protection index: IP 30 klik Settings available Key Action Function Product Type + Short Press (< 5s.) On EEK513P / EE815 EEK523P / EE816 Long Press (> 5s.) Dim up EEK523P / EE816 Short Press Off EEK513P / EE815 EEK523P / EE816 Long Press (> 5s.) Dim down EEK523P / EE816 Short Press To start scene 1 EEK523P / EE816 Long Press (> 5s.) To start scene 1 Short Press To start scene 2 Long Press (> 5s.) To start scene 2 Short Press To start scene 3 Long Press (> 5s.) To start scene 3 Short Press To start scene 4 Long Press (> 5s.) To start scene 4 11.35

IR User Remote Controls for EE808 Technical Characteristics Detection range EEK513P / EE815 Supply voltage 230 V AC + 10% -15% Frequency EEK523P / EE816 motion area: diameter 7m (product installed at 2½m height) presence area: diameter 5m (product installed at 2½m height) 50/60 Hz Local lux threshold setting 5 to 1000 lux 3 modes available Local time setting Commissioning via installer remote control 1 min to 1hr EE807 for power up, absence / presence mode, timer active / passive cell Control with IR user remote control EE808 for ON / OFF override EE808 for ON / OFF override and dimming up / down Output Push button input Terminals 16A AC1 relay output (cut live): - 2300W incandescent or 230V halogen: > 26000 cycles - 1500W VLV halogen lamps with ferromagnetic or electronic transformer: > 35000 cycles - 1000W / 130 μf parallel compensated fluo tube: > 50000 cycles -23 x 23W fluo-compact with electronic ballast: > 20000 cycles phase input for absence / presence detection (semi-automatic / automatic mode) same phase as power supply. for 1.5mm 2 rigid / lexable wires Power dissipation 300mW 60mW Isolation class Protection Operating temperature Storage temperature II IP41 / IK03-10ºC to +45ºC -20ºC to +60ºC Standards IEC 60669-1, IEC 60669-2-1 14V / 50mA (for a DALI bus with 24 ballasts) - No isolation between the mains and the DALI bus to dim up / down and absence / presence detection (semi-automatic / automatic mode) same phase as power supply. Detection areas Mounting h 10 < t < 28mm t ceiling D 5m x y S h 2.5m 3m 3.5m x 5m 5m 5m y 7m 8m 9m protective cover cable clamp 2.5m 2.5m auto test 1 1m Settings EEK513P/EE815 EEK523P/EE816 2 on 1 min lux Connection Pluggable directly into marshalling box. 1 h 20 min 11.36

Mounting Methods Mounting Methods Hanging from ceiling suspension system with Caddy Clips Direct ixing to lighting trunking Direct ixing to ceiling or wall with No. 8 screws Screw or nail gun to surface via clip in attachment (attachment connects to top or rear extrusion). klik Screw direct to surface Drop rods to top via channel nut Drop rods to top via channel nut 11.37