Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Similar documents
Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery Ventilators

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Energy Recovery with Cooling and Heating

Bill McCullough. Director ERV Products. Dallas, TX

Modular Supply Make-Up Air Unit

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Direct Gas-Fired Make-Up Air Models DG and DGX

Indirect Gas-Fired Make-Up Air

MiniCore Ventilator (500, 1000) Series Engineering Guide

Modular Heating & Ventilating Unit Model IGX-HV

GreenJet Transfer Fans

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Plenum Fans. Model HPA. Direct Drive

The ultimate fresh air solution.

THE ULTIMATE ROOFTOP SOLUTION

Energy Recovery Ventilators MCV CORE Series. Customer for Life: Power of Connections Johnson Controls, Inc Page 1

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

MAXA-MI$ER Energy recovery solutions

SEQUENCE OF OPERATIONS

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Electric Duct Heaters. IDHB & IDHC Series

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Make-Up Air Systems. Performance. Model DGK, DG, DGX

BOOK 2 SPECIFICATIONS

Product Release Summary

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

RT-OA TM Rooftop Outdoor-Air (DOAS)

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

62DA,DB,DC,DD,DE,DF07-38

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

Total Recovery for ALL Climates Models TR & TRC

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

BOOK 2 SPECIFICATIONS

************************************************************************************************************************

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

Put the V back in HVAC

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Cultivator & Hybrid Cultivator

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Maverick II Commercial Rooftop Systems 15 to 75 tons

Submittal Data Performance Data Electrical Data

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

10-year industry best core warranty. 5-year warranty on balance of unit.

Outside Air Requirements... SOLVED!

Make-Up Air March 2012

Designing Energy Efficient Outdoor Air Systems

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Scholar III Unit Ventilator

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

48PGD/E/F/L/M/N PG20-28

************************************************************************************************************************

1.1 This section applies to air handling units for HVAC Systems.

XeteX, Inc. All Rights Reserved.

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Flexible & Innovative. Cooling Solutions

THE RIGHT SPEC. RIGHT NOW.

Submittal Summary Page

Adding More Fan Power Can Be a Good Thing

SA Series Start up Report

REPLACEMENT PARTS LIST

RoofPak Applied Rooftop Systems

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

************************************************************************************************************************

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

SAFETY AND INSTALLATION MANUAL MODEL 8100

COMcheck Software Version Mechanical Compliance Certificate

50TM COMBINATION HEATING/COOLING UNITS

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

Addendum Downsville Pike Hagerstown MD April 29, 2016

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

COMcheck Software Version Mechanical Compliance Certificate

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Reference Guide for Microprocessor Controller

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Transcription:

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017

Heat Recovery Ventilators Greenheck s model PVe is a sensible idea for your fresh outdoor air needs. This aluminum plate air-to-air heat recovery unit transfers sensible (heat) energy from the exhaust airstream to the supply airstream. This provides pretempered fresh outdoor air to the building, allowing you to reduce the size of your heating and cooling equipment, resulting in lower utility bills year round. Light industrial applications, as well as bathroom and locker room exhaust, are great places to use Greenheck s model PVe. Typical heat recovery ventilator applications are listed below. Locker Rooms Schools Casinos Dormitories Animal Shelters Bars and Clubs Office Buildings Printing Shops Maintenance Shops Nursing Homes Auto Repair Buildings Veterinary Hospitals Features Industry Leading Selection Software (CAPS) Compliance with Industry Standards Benefits Greenheck s Computer Aided Product Selection (CAPS) software reduces design time by quickly analyzing system design parameters and providing a list of units to minimize cost and optimize performance. The program outputs fan, electrical, and plate heat exchanger data, as well as configuration-specific 2-D and 3-D Revit drawings for easy implementation into building schedules and plans. ASHRAE standards and energy codes have a mandated enthalpy recovery ratio of 50% or greater. Greenheck s CAPS program can help you select a compliant unit that has verified performance data by AHRI. Code officials and building owners recognize the benefits of utilizing energy recovery in applications with large amounts of ventilation air and Greenheck can help provide the best unit. Maintenance/ Serviceability Greenheck s heat recovery ventilators have been designed to allow easy access to filters, blower assemblies and plate heat exchanger. As reassurance to the customer, each unit carries a one year warranty. System Efficiency/ Payback The incorporation of heat recovery allows for equipment downsizing as well as continued lower energy costs throughout the life of the equipment. This downsizing moderates the variability of loads on the system, increasing the efficiency of furnaces, electric heaters, DX coils and water systems. Product Certifications Greenheck takes pride in offering a high quality, reliable product. We invest our resources into designing, testing and manufacturing products to ensure customer satisfaction. ETL Listed for electrical and overall unit safety. Every unit is tested at the factory before it is shipped to the jobsite. Energy recovery wheels are certified by the AHRI Air-to-Air Energy Recovery Ventilation Equipment Certification Program in accordance with AHRI Standard 1060. Actual performance in packaged equipment may vary. Certified ratings are available in the Certified Product Directory at ahridirectory.org. 2

Standard Operation and Unit Controls How does the plate heat exchanger work? Improving building indoor air quality requires fresh outdoor air be provided to the building. A heat recovery ventilator combines both airstreams into one unit and transfers energy between the airstreams while keeping the air separated. This unit reduces energy consumption while meeting the ventilation requirements of your building. Winter Operation On cold winter days, the warm exhaust air (return air) from the building heats up the plate heat exchanger. Cold outdoor air hits the warm plate heat exchanger which heats the air entering the building with a sensible effectiveness of up to 70%. In this example, if the space temperature is 72 F during the winter, on a 0 F day, the air coming off of the plate heat exchanger (supply air) would be 50 F. The heating equipment now only needs to heat from 50 to 72 F, rather than 0 to 72 F saving significant amounts of energy all winter long. 0 F Return Air 72 F Heat Recovery Technology PVe plate heat exchanger Air 22 F Supply Air 50 F Summer Operation On hot summer days, the unit takes cool conditioned air from the space and passes it through the plate heat exchanger. Hot summer outdoor air hits the cool plate heat exchanger which cools the air entering the building with a sensible effectiveness of 70%. In this example, if your space is air-conditioned to 75 F during the summer, on a 105 F day, the air coming off of the plate heat exchanger (supply air) would be 84 F. The cooling equipment now only needs to cool from 84 F to 75 F saving significant energy throughout the summer. 105 F Return Air 75 F Heat Recovery Technology PVe plate heat exchanger Air 96 F Supply Air 84 F Unit Controls Remote Panel - With the optional remote panel, you have control and the information you want. Monitoring lights, on/off time-clock control, or on/off/auto switch are a few of the available options. So whether you want to control the unit operation via a 7-day time clock or simply want to monitor unit performance, the remote panel is the option that provides valuable information. Network Interface - An optimum solution for connecting the unit to a Building Management System (BMS). The network interface offers an easy-to-use, remote-mounted display. It easily integrates to BACnet IP, BACnet MSTP, LonWorks or Modbus. Two operating options are available: Monitor only: Allows the BMS to monitor the status and functions of the unit through a factory-installed controller. Control commands will be provided by terminal-style signals from a remote panel or external to the unit. Monitor and Control: Allows the BMS to monitor the status and command the basic functions of the unit through a factory-installed controller. A remote panel is not available with this option. 3

Standard Features and Optional Accessories 1 Weatherhood Downturn intake hood 2-inch aluminum mesh filters (mist eliminating) hood with integral backdraft damper 6 Aluminum Heat Exchanger AHRI Standard 1060 Certified Performance High heat transfer up to 70% sensible effectiveness Corrosion-resistant 2 Construction Double-wall construction with 1-inch insulation secured in place between solid inner and outer panels Insulation density of 1.5 lbs/cu. ft. Easy lift-off removable hinged access doors with stainless steel hinges and quarter-turn latches 1 2 3 4 3 Dampers Low-leakage, factory-mounted and wired insulated or non-insulated dampers 6 5 4 Frost Control Optional timed exhaust frost control cycles the blower on and off based on a factoryprovided timer Optional face and bypass dampers allow air to bypass the plate heat exchanger when the temperature of the exhaust air leaving the exchanger drops below the adjustable setpoint allowing warm exhaust air to melt the frost 5 2-inch MERV 8 or MERV 13 outdoor or exhaust filters 7 Integral Drain Pan Stainless steel Double-pitched for true condensate drainage 4

Standard Features and Optional Accessories 8 Integral Base Solid base with half-inch upturned lips around bottom openings, perimeter and joints to prevent water from leaking through the base and into the building S Standard Feature O Optional Feature Optional Accessories CO 2 Sensor - Engages the unit based on CO 2 levels, or it can increase or decrease airflow through the use of a VFD. Can be unit-mounted or space-mounted depending on your application. Dirty Filter Sensor Indicates when filters become dirty. An indicator light may be wall/beam mounted or provided with a remote control panel. Only Operation Allows for the exhaust fan to run continuously while the fan in off. Factory-Mounted Sensors - Amp draw, pressure or temperature sensors are available to monitor unit operation or to actively control the unit with controls by others. Plate Economizer Control - Integral face and bypass dampers allow cool air to bypass the plate heat exchanger when it s in the free cooling range (temperature or enthalpy). When the conditions are too warm or cold, the dampers cycle back to allow heat recovery. Service Receptacle A 115 volt GFCI outlet is mounted externally in a NEMA-3R box for the convenience of service personnel. A separate 115 volt power source is required. 9 7 9 8 9 and Supply Fan Double-width, double-inlet forwardcurved wheels Neoprene isolation Optional factory-provided Variable Frequency Drive (VFD) 10 Control Center (not shown) 24 VAC control voltage Control transformer Disconnect switch UL Listed, Recognized or Classified electrical components Factory-wired for single point power connection 5

Typical Applications The PVe unit can add to the benefit of a building design anywhere that outdoor air is required and the exhaust air is Class 3 or lower per standard ASHRAE 62-2016. Class 3 air is defined as significant contaminant concentration, significant sensory-irritation intensity, or offensive odors. With the aluminum plate heat exchanger s minimal crossleakage design, Greenheck has targeted light industrial applications in addition to commercial and institutional comfort applications. With Ducted Air Handlers The PVe unit may be combined with ducted air handling units or fan coil boxes. A single heat recovery ventilator provides fresh outdoor air for multiple air handling units or in a one-to-one ratio where a single heat recovery ventilator and air handler serves only one space. AIR HANDLING UNIT (AHU) Heating Coil Cooling Coil Heating Coil Cooling Coil SUPPLY AIR AHU OUTDOOR AIR UNIT (OA unit) WITH HEAT RECOVERY OUTDOOR AIR Fan EXHAUST AIR 72 F 50% 72 F 50% ZONE 1 ZONE 2 Plate Heat Exchanger RESTROOM RELIEF AIR OUTDOOR AIR With Packaged Rooftop Equipment RETURN DUCT SIDE VIEW SUPPLY DUCT This diagram illustrates how heat recovery ventilators may be used in conjunction with packaged rooftop equipment. Fresh, outdoor air enters the heat recovery ventilator and is pretreated before entering the heating/ cooling equipment. This pretreating occurs because the plate heat exchanger is transferring sensible energy between the outdoor air and the building exhaust air. RESTROOM ZONE 1 72 F 50% Fan AIR HANDLING UNIT (AHU) OUTDOOR AIR SIDE VIEW EXHAUST AIR Heat Plate Exchanger PLATE HEAT RECOVERY VENTILATOR (PVe) HeatingCooling Coil Coil SUPPLY AIR SUPPLY DUCT RETURN DUCT 6

Dimensional Data Model A B C D E Approx. Weight (lbs.) Airflow Range (cfm) Motor HP PVe-20 104.1 59.7 41.5 20.3 20.7 1,300 1,000-2,200 1/4-2 PVe-35 104.1 59.7 49.2 25.2 17.7 1,600 2,200-3,400 1/2-3 PVe-45 110.6 59.7 61.1 25.2 19.0 2,100 3,400-4,500 1-5 PVe-55 116.5 59.7 76.1 25.2 23.8 2,700 4,500-6,000 1 1 2-5 These weights include sheet metal weights added together with the largest motors, blowers and accessories for the units. D A Weatherhood Face/Bypass Damper Plate Ventilator B Weatherhood E Weatherhood Bypass Damper Face Damper Plate Ventilator C Control Center Available Intake/Discharge Positions Option Bottom Top Side End Intake X Supply Air Discharge X X Return Air Intake X Air Discharge X 7

Additional Energy Recovery Products Model MiniVent A low-profile preconditioner designed for compact indoor installations requiring 150 to 850 cfm and may be floor mounted or ceiling hung. Model MiniCore This preconditioner utilizes an energy recovery core for indoor installations ranging from 300 to 1,000 cfm. Designed to be mounted vertically or horizontally with optional intake and discharge connections configurable on site. Model ERV This reliable preconditioner provides total energy recovery primarily designed for indoor applications requiring 500 to 12,000 cfm. Model ERVe This preconditioner provides total energy recovery for outdoor applications requiring 1,000 to 6,000 cfm. Model ERCH This dedicated outdoor air unit combines the benefits of total energy recovery with supplemental heating and cooling in applications designed to supply 100% outdoor air. Airflow capacities range from 1,000 to 10,000 cfm. Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Greenheck P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com Prepared to Support Green Building Efforts Copyright 2017 Greenheck Fan Corp. 00.TAP.1001 R4 4-2017 IW