Similar documents

CESI EXTENSION D. 02/12 ~ FGH ~ to EC-Type Examination Certificate CESI 03A TEX057X Equipment: Explosion proofsolenoid series OA-; OZA; MZA-A- Manufac

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

IECEx Certificate of Conformity

IECEx Certificate of Conformity

manual addendum DELPHI Ex

Operating Instructions for Liquid Level Transducer Model : MM Series

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Inductive slot sensor

Technical Data. General specifications. Rated operating distance s n 5 mm

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

IECEx Certificate of Conformity

Explosion-proof Immersion Heater Type D-8660

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Certificato numero: 300 RIVA TECNOIMPIANTI S.R.L. UNI EN ISO 9001 : 2015 ISO 9001 : 2015

IECEx Certificate of Conformity

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Certification Supplement Manual

EU DECLARATION OF CONFORMITY

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

INSTRUCTION MANUAL (ATEX / IECEx)

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

Drive systems for the chemical, oil and gas industry. Electric drives and systems

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Operating instructions For Vibration level switch. Model NSV

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

IECEx Certificate of Conform ity

Technical Data. Dimensions

Flameproof Manual Call Points Series MCP

IECEx Certificate of Conformity

Approvals, Certificates and Conditions

OPTIBAR DP 7060 Supplementary Instructions

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

INSTRUCTION MANUAL. PLASTIC MENDER mod. ITA

OPTIBAR P 1010/2010 C Supplementary instructions

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

IECEx Certificate of Conformity

IECEx Certificate of Conformity

EU Declaration of Conformity EMC Directive 2014/30/EU, ATEX Directive 2014/34/EU, PED Directive 2014/68/EU No: MMI SE

OPTIWAVE X500 Supplementary Instructions

IECEx Certificate of Conformity

ATEX, NOMENCLATURE AND CODING

User s Manual YTA610 and YTA710 NEPSI Certification

Certificate of Compliance

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

Exp, pressurized systems

Manual Power relay SR853

Supplementary Installation and Operating Instructions. Category II2G

INSTRUCTION MANUAL (ATEX / IECEx)

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate of Compliance

Certificate of Compliance

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

Physikalisch-Technische Bundesanstalt

IECEx Certificate of Conformity

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

MICROpeL 75 Combustible Gas Sensor Part Number: PM

ATEX QAN and IECEx QAR, DNV 06 ATEX 0425Q & Presafe 15 ATEX 7122Q ClampOn project reference Replaced by Replacement for Number of pages

4) Intrinsic Safety Certification

Certification Supplement Manual

Technical Data. Dimensions

Annubar Flowmeter Series

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Instruction Manual Captive Air Level Control. Model NLP

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Electrical Installations Design, Selection, Erection and Inspection

ATEX, NOMENCLATURE AND CODING

UL HAZARDOUS LOCATIONS SERVICES


Certification Supplement Manual

ATEX Explained A brief Introduction

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Certificate Surveillance audit

TRASCO ATEX Couplings

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

UE/CE DECLARATION OF CONFORMITY

ANNEX GD-CERT-EX-EN SIT

Centurion Guided Radar HAWK CGR SERIES

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

IECEx Certificate of Conformity

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Transcription:

CESI,...dlSmES!r.~t: EXTENSION n. 05/15 ~ FGH ~ to EC-Type Examination Certificate CESI 02ATEX015X Equipment: lnductive transducer type ETHA-4/. Manufacturer: ATOS S.p.A. Address: Via alla Piana, 57-210 18 Sesto Calende (Varese) - Italy Admitted variation Updating to EN60079-0 (2012) and EN60079-31 (2014) standards. Updating nameplate for multi-certification ATEX I IEC EX l... Updating ofthe documentation. The details ofthe admitted variations are specified in the descriptive documents annexed to this extension. Marking The equipment shall be marked as follows: ~ II 2G Ex d I1C T6, T5, T4 Gb ~ II 2D Ex tb mc T85 -c, TIOO-c, T135 -c Db IP66/67 The temperature class and/or the maximum surface temperature are function ofthe ambient temperature: Tamb: -40 C I +40 CI+70 C. Electrical characteristics Ali electrical characteristics remain unchanged. Detailed characteristics are reported in the descriptive documents annexed to the certificate. This extension and annexed descriptive documents must be annexed to the EC- Type Examination Certificate CESI 02A TEXO 15X. This document may only be reproduced in its entirety and without any change. Date 21 May 2015 - Translation issued the 21 May 2015 Verified Approved Roberto Piccin PRO N. 018B Membro degli Accordi di Mutuo Riconoscimento EA. IAF e ILAC f/3rua,:f{feg~::(litt:.t;r~!'t:ec;,ts (ESI S.p.A. Via Rubattino 54 1-20134 Milano - Italy Tel: +390221251 Fax: +390221255440 e-mail: info@cesi.it www.cesi.it (Robe Capitale sociale (8.550.000 interam nte ver o C.F. e numero iscrizione Reg. Impre e i Milano 00793580150 P.I. IT00793580150 N. R.E.A.429222

CESI EXTENSION D.05/15 to EC-Type Examination Certificate CESI 02ATEX015X Report n. EX-B50 I0825. Routine test Unchanged. Descriptive documents (prot. EX-B50 10836) - Technical Note n. SAS-563-D/O (pg.2) - Safety Instructions n. TTl90-5 (pg.3) - n. 4 -ETHA-21 0000- I rev. I - n. 6 -ETHA-I 00050 - Declaration of Conformity TTI87/4 (fac simile) One copy of ali documents is kept in CESI files. dated dated dated dated dated 08.05.2015 11.05.2015 25.03.2015 25.03.2015 08.05.2015 Special conditions for safe use (X) Beginning from this extension the "X" sujjìx is added to the cesi 02ATEXO 15 certificate number and it becomes CESI 02A TEX015X for the insertion of the following special condition for safe use: The flamepaths are specified in the manufacturer drawings. For information regarding the dimensions of the flameproofjoints the manufacturer shall be contacted. The characteristics ofthe connecting cables and ofthe accessories used for cable entries shall be suitable for the use in the ambient/operating temperature of the transducer. For the selection of the operating temperature of the cable, depending on the installation and 1 or operation temperatures of the transducer, refer to the Safety Instructions provided by the Manufacturer. The accessories used for cable entries shall be certified separately and suitable for the installation hazardous area. Information relating to use, installation, repair and maintenance of the equipment are included within the safety instructions. Essential Health and Safety Requirements The Essential Health and Safety Requirements are assured by compliance to the following standards: EN 60079-0: 2012 - Explosive atmospheres - Equipment - Generai requirements. EN 60079-1: 2007 - Explosive atmospheres - Equipment protection by flameproof enclosures "d". CEI EN 60079-1: 2008 (annex I) - Explosive atmospheres - Equipment protection by flameproof enclosures "d". EN 60079-31: 2014 - Explosive atmospheres - Equipment dust ignition protection by enclosures "t". Prot. 85010833 P: 2 This document may only be reproduced in its entirety and without any change Page 2/2

Dichiarazione di conformità Declaration of conformity TT187/4 Atos spa CE La Ditta / The Company ATOSs.p.a. 21018 Sesto Calende /Italia via alla Piana 57 Dichiara con la presente la conformità al Prodotto / herewith dec/ares conformity of the Products Prodotto / Product Tipo / Type TRASDUTTORE INDUTTIVO INDUCTIVE TRANSDUCER ETHA-4/* Modo di rotezione / Protection mode Il 2 G Ex d IIC T6, T5, T4 Gb Il 2 D Ex tb IIIC T85 C, T1oo-c, T135 C Db IP66/67 Certificato / Certificate CESI 02 ATEX 015 X In accordo alle norme sottostanti / in accordance with the below applicable regulations Direttive CEE applicabili / applicable EC Directive 12004/108/cE) 194/9/CEj In quanto conforme alle Norme Europee Armonizzate / As in accordance to the European Armonized Standards EN 61000-6-1 EN 61000-6-3 EN 60079-0 (2012) EN 60079-1 (2007) EN 60079-31 (2014) CESI protocollo 85010836 allegato al certificato Organismo Notificato I Notified body n 0722 CESI 02 ATEX 015 X 21/05/2015 Notifica / Notification CESI 02 A TEX 034Q Data/Date: 08.05.2015 Firma/Signature:. Pago 1/1