Test Lamp for 210 series flame detectors Non EX

Similar documents
Design Manual Installation Operation Maintenance

Testing Emission Source ITES Operating Manual OM

Model TL104 MANTL104. Test Lamp for Flame Detection

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

KM300 Carbon Monoxide Detection System Installation Manual

Flame Simulator User Manual. Publication Rev. A

ESV1500 Illuminated Cabinet INSTRUCTION MANUAL

Excel Click & Go Lite

UV/IR Flame Simulator Model FS-1200

ANTIBACTERIAL HAND VAC WITH UV LIGHT

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Dräger REGARD -1 Control System

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Preamplifier Power Supply PPS-02 user's guide

EU Declaration of Conformity Annex

C Note! LGI16... Burner Controls. Building Technologies

Installation instructions

EC-Declaration of Conformity

Operating instructions (translation) Stunning Device for Small Animals

Lawnmowers (pedestrian controlled, battery powered)

Operating Manual ECCO/ECG Couch

Instruktions manual. At skræmme fugle med laser!

C e r t i f i c a t e Of Conformity No.: 0560-CPD /AA/05

VISION H. Instruction manual

Operating Manual 3 part Multi Couch 2017

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

WIRELESS MOTION SENSOR USER MANUAL MULTI LANGUAGE START-LINE TRANSMITTER AWST-6000

EM8651 PIR Motion Detector

EU Declaration of Conformity Annex

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Gas cylinder scale Model GCS-1

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Operating Manual 3 part Endoscopy Couch

HYTEK ATEX APPROVED TANK ALARM

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

HYTEK ATEX APPROVED BUND ALARM

Installation Guide. Ceiling PIR Detector (311) Features and Connections

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Hand Vacuum Cleaner User's manual

GAN Electronic 750W/1000W DE EU

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

ORIGINAL INSTRUCTIONS

Dräger Flame 2500 Flame Detection

Chain saws (electric mains powered and battery powered)

RESISTENT PLUS D A CH Gebrauchsanleitung GB IRL AUS USA NZ CDN IND Instructions for Use... 12

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

HXL. Operating instructions

Clam Basic. 28x38 cm 38x38 cm 40x50 cm OPERATOR S MANUAL.

The SharpEye 40/40I (IR3) Flame Detection

RE-PR3-E-27 3-Phase Panel Mount 27kW

Garden blowers, vacuums and blower/vacuums (electric mains powered)

Electronic timeswitch

English... 5 Čeština Slovenčina Magyarul Polski Русский... 85

With this symbol Gavita declares that this product complies with legal European requirements.

Instruction manual EN

compact office 24V compact office 24V Lux

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

Downlight ENCORE DL6 15W 2700K

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY INFRARED HEATED SEAT MASSAGER MODEL C90005

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Clam Basic Cap. 9x16 cm OPERATOR S MANUAL.

Dräger Flame 2700 (Multi-IR) Flame Detection

Product Manual Glue Applicators MS 80 and MS 200

Flame Simulator: FS-UVIR-975. User Manual

Robotic Mowers (battery powered and charging station connected to electric mains or low voltage supply)

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

GB Operating instructions

EBDSPIR-PRM-LV Product Guide

FEC403EN Installation Manual

Lawn trimmers and lawn edge trimmers (hand held electric mains powered)

Operating Manual Bathroom Balance

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

General Alarm System. User Manual. Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND

compact office 24V compact office 24V Lux

Dräger Flame 2500 (IR3) Flame Detection

Flame detector. The QRA4.U is for use with the following types of burner control:

Sprint Mag XS. 15x15 cm OPERATOR S MANUAL.

0051 CPR 0423 CONTROL AND INDICATING EQUIPMENT WITH INTEGRATED POWER SUPPLY EQUIPMENT. ELECTRICAL AUTOMATIC CONTROL AND DELAY DEVICE (optional)

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Dräger Flame 2350 (UV&IR) Flame Detection

PVL1300 INSTRUCTIONS FOR USE

Specification for testing to be conducted at periodic surveillance of products and systems

The SharpEye 40/40M (Multi IR) Flame Detection

Flame Detection Jon Sarfas

Gebrauchsanweisung User manual 使用手冊マニュアル

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Flame detector. The QRA4.U is for use with the following types of burner control:

POL-200-TS User Manual

EU Declaration of Conformity EMC Directive 2014/30/EU, ATEX Directive 2014/34/EU, PED Directive 2014/68/EU No: MMI SE

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

MGC Dock User s Manual

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

E-17 Flammable Gas Detection and Alarm System

MOBILE CALL GSM Alarm System User s Manual

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Transcription:

Manual TC-169/1 Test Lamp for 210 series flame detectors Non EX http://sense-ware.com Check the website www.sense-ware.com for the latest information and latest version of this manual as well as the applicable Declaration(s) of Conformity. Due to the policy of continued product development Sense-WARE Fire and Gas Detection BV reserves the right to alter or amend information in their publications without prior notice and no responsibility can be accepted for errors or omissions.

Content 1. Safety instructions... 2 2. Description... 3 3. Operation... 3 4. First use... 3 5. Charging:... 4 6. Battery replacement... 4 7. Failure analysis... 4 8. Warranty, returns and repairs... 5 9. Appendix: EU declaration of conformity... 6 1. Safety instructions Please read this manual carefully and study the cautions, before you start installing or using this equipment. Herewith you ensure a safe and proper use of this equipment. These safety instructions provide important information and must be consulted. 1. Only suitable for SENSE-WARE 210 series flame detectors: UV/IR-210/1, UV-185/5 and IR3-109/1 2. The life time of the battery is negatively influenced if you use the test lamp continuously longer than 10 minutes and in one go. 3. The T-169/1 test lamp has a protective grate which should not be removed. 4. Do not stick objects through the grate. 5. Store the test lamp clean and dry. A dirty reflector will reduce the test range. 6. Do not use the test lamp in wet conditions. 7. Keep away from children. 8. Do not point directly at eyes from a short distance. Do not look directly into the light. 9. The test lamp should not be used when damaged. 10. Do not open the lamp, send it back for repair. Contact SENSE-WARE for details. 11. Do not throw the unit in a fire. The battery could explode when exposed to intense heat. 12. Warning, after use the grate may be hot. 13. The sealed lead battery has a lifetime of several years. Please ask your local city official how to dispose the unit. 14. Make sure testing of the flame detectors does not activate unwanted alarm signals. 15. Only for use in safe areas. carrying case P 2/6

2. Description The non EX SENSE-WARE TC-169/1 flame detector test lamp activates 210-series flame detectors from SENSE- WARE; the UV/IR-210/1, the UV-185/5 and the IR3-109/1. For all models the detection range is 4 meters (13 ft). The TC-169/1 test lamp is non EX, suitable for use in safe areas only. Cautions The TC-169/1 test lamp is only compatible with the 210-series flame detectors of SENSE-WARE. The test lamp is not suitable for flame detectors of other brands. Specifications: Adapter (charger) 100-240 Vac, 500 ma switching with plugs for US, EU, GB and AU Test range for all 210 series flame detectors Up to 4 m (13 ft) from SENSE-WARE Not suitable for detectors of other brands Battery sealed Lead Acid battery, 12 Vdc / 2.7 Ah Lamp H3, 12 Vdc / 100 W Use 10-15 minutes under optimal conditions and continuous use Housing ABS (plastic) black Ingress protection rating IP30 Temperature range +4 to +40 0 C (+39 to +104 0 F) Country of Origin/Intrastatistic Number EU, 8531 10 30 Material carrying case Case: polypropylene, inlay polyurethane Shipping dimensions (box) carrying case 440 x 340 x 280 mm (17 3/8 x 13 3/8 x 11 ) Shipping weight incl. test lamp carrying case 5.0 kg (11.1 lbs) 3. Operation Before a test is carried out make sure the flame detector is switched on and the alarm outputs are in override. Please avoid unwanted alarm signals as a result of your test. The test lamp will turn on/off by pressing/releasing the trigger. 1. Point at the flame detector within the test distance and on the central axis of the cone of vision of the detector. 2. Press the trigger and wait until the Flame detector is activated. 3. Operate the test lamp for max. 30 seconds. The 210 series flame detector should always come into alarm within this time period. 4. Do not use the test lamp for longer than 1 minute. 5. Wait at least 30 seconds after each test before performing the next test. 4. First use 1. Remove the cover of the battery compartment (on the top of the test lamp). 2. Take the battery. 3. Place the battery into the battery compartment in such a way that the terminals of the 12 Vdc battery are making contact with the terminals of the lamp. 4. Place the cover of the battery compartment in the original position. 5. Charge the battery for at least 4 hours (6 hours max.). Remark: The battery is already charged when leaving the factory. However, the unit should be charged immediately after purchase. P 3/6

5. Charging: 1. Plug in the charger and apply the charger cable to the Test Lamp. The charge time for a completely discharged battery is +/- 4 hours. Do not charge for more than 6 hours. 2. The Test Lamp must be fully charged when stored immediately after use. 3. Every 3 months the unit should be recharged when stored without using. 4. During charging the red LED on the left of the test lamp is on. However, when the test lamp is completely discharged, during the first hours the red LED may be off. 6. Battery replacement 1. The battery can be ordered locally by means of the battery information in the specification. 2. Remove the cover from the battery compartment. 3. Slide the new battery in the battery compartment. Make sure that the poles are heading in the direction of the terminals of the test lamp. 4. Place the cover of the battery compartment in the original position. 5. Charge the new battery charged immediately for at least 4 hours (6 hours max.). Battery specifications: 46 Battery type Battery voltage and capacity Terminal type Terminal position Dimensions Type Ordering information sealed rechargeable lead acid battery 12 Vdc/ 2.7 Ah spade see drawing battery terminal position l x w x h 103 x 70 x 46 mm BATT4P Catalog Code Part # Description TC-169/1 SW1153 Test lamp for 210 series flame detectors non EX 7. Failure analysis Possible root causes of faults: 1. The flame detector to be functionally tested is not a 210-series flame detector from SENSE-WARE. 2. The flame detector is not working properly and will thus not be activated by the test lamp. 3. The batteries of the test lamp are empty 4. The electronics of the test lamp is damaged. Remarks If you ask for the support of SENSE-WARE, make sure that you well-reported the fault in the log. - + 103 70 Battery terminal position P 4/6

8. Warranty, returns and repairs Warranty: In the Warranty arrangement the conditions are mentioned which apply for the SENSE-WARE flame detector test lamp. If not explicitly mentioned in this manual, the Orgalime S2012 delivery terms and conditions apply. SENSE-WARE provides for the T-169/1 test lamp a warranty of 12 months after supply, for defects in the material, providing normal use and maintenance. SENSE-WARE will under these circumstances, during the warranty period free of charge repair and replaces parts of products which are returned according to the instructions of this warranty section. All replaced parts become property of SENSE-WARE. The warranty is only valid for companies which directly purchased the goods from SENSE-WARE and cannot be transferred to other parties. From the warranty are excluded: 1. Defects which are caused by improper use, an incident or lack of maintenance. 2. Defects or damages which are caused by improper installation or manipulating the hardware and/or software. 3. Applying the wrong operating voltage, water damage etc., or wrongly executed repairs and repairs with nongenuine spare parts. 4. Products from which the serial number is removed or unreadable. 5. Normal wear and tear, including cosmetic damage. Returns and repairs: 1. Ask via your supplier for a SENSE-WARE RMA (Returned Material Authorization). For returns to the factory an RMA is always required. 2. You will get an RMI (Returned Material Information) fill-in form on which you or your supplier fills in the SENSE- WARE invoice number, the serial number and the type of fault. 3. In case of an authorization SENSE-WARE will provide your supplier an RMA number which you have to add to the packing list of the return shipment. You also have to include the RMI form in the shipment plus faxing or emailing it to SENSE-WARE. 4. The shipping cost to and from SENSE-WARE are for the buyer. 5. Make sure that the test lamp is packed thoroughly before you return it to SENSE-WARE. 6. In case you did not buy the test lamp directly from SENSE-WARE please contact your supplier for an RMA. 7. For goods with an RMI, which require a repair within the warranty period, you can request SENSE-WARE an advance replacement via your supplier. Remark: The test lamp does not contain parts which are suitable for a local or field repair. P 5/6

9. Appendix: EU declaration of conformity In accordance with EN/ISO/IEC 17050-1:2010 Sense-WARE Fire and Gas Detection B.V. Storkstraat 7, NL- 3905 KX Veenendaal, the Netherlands, EU Description: Flame detector Test Lamp Brand Name: SENSE WARE Model: T(C)-169/1 Article T(C)-169/1 Specification Flame detector Test Lamp EMC Directive 2014/30/EU Complies with the requirements of the European Community Directive on the Harmonization of the Legal Regulations of the Member States on Electromagnetic Compatibility. Electromagnetic Compatibility was based on the following standards: EN 61000-6-3: generic emission standard house hold environment EN 61000-6-2: generic immunity standard for industrial environment RoHS2 Directive 2011/65/EU Conforms to: EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances. Signed for and on behalf of the manufacturer by: Jan Nijkamp, Business Development Manager Veenendaal, 21 November 2016 P 6/6