Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Similar documents
PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Remote Chexit Module (RCM) System. General Information

DE5300 Delayed Egress System. General Information

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for models:

Series. Access Power Controllers. Installation Guide

Installation Guide for models:

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Rack Mount Series Installation Guide

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Access Power Controllers with Power Supplies

AL800ULADA. NAC Power Extender. Installation Guide

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Public Safety DAS Annunciator Panel

MODEL B2 INSTALLATION MANUAL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

TECHNICAL DATA OBSOLETE

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

631RF Amp Power Supply

AL600ULX Series. Power Supply/Charger. Installation Guide

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

AL600ULADA. NAC Power Extender. Installation Guide

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

D A R A - 4. Data Aire Relay Auto-Changeover

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

CALL YOUR SALES CONSULTANT TODAY,

/ How To Order

Pump-Down Controller MODEL 4052

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Model 17A00 Expansion Enclosure

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Exit Stopper. STI-6400 Series

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Pump-Up Controller MODEL 4062

RELEASE DEVICE CONTROLS

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Exit Stopper. STI-6400 Series

Programmable Thermostat

Strikemaster ES Engineering Manual

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Addendum for STI-6406 with Dual Access Control

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

/9308 External Battery Chargers Installation Instructions

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

Remote NAC Power Supply D7038

Specification/ Data Sheet

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

DS160/161 Request To Exit PIR sensors Installation Instructions

Power Supplies. Overview

Analog Room Pressure Monitor RPC Series

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Carbon Monoxide Transmitter

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Fire / CO Alarm Interface

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Transcription:

F1! 44487023 These instructions cover the following parts: PS902 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS902 power supply. 900-KL Keylock (optional) - Page 2! WARNING:! WARNING: DANGER! DANGER: PS902 Power Supply - Pages 1-3 900-BB Battery Backup (optional) - Page 3 PS902 Power Supply Specifi cations: Input 120/240 VAC, 1.1 A, 50/60Hz, High Voltage Class 1 Wiring Required Output 2 Amp DC @ 12/24 VDC Enclosure 14 H x 12 W x 4 D (8 knockouts, 1/2 or 3/4 ) Temperature Range 32-120 F (0-49 C) Fuse F1, T3.15A 250VAC! CAUTION: For protection against risk of fi re, replace fuse with same type and rating Compliance Compatible Boards (Optional, 1 board maximum) Fire Alarm Input Board (Optional) Battery Backup Board (Optional) AC Monitor Output UL 294, ULC-S318, RoHS, & FCC Part 15, Class 2 Output 900-2Q 900-4R 900-4RL 900-8F 900-8P 900-FA 900-BB INST. INSTRUCTIONS - 44487098 INST. INSTRUCTIONS - 44487106 INST. INSTRUCTIONS - 44487080 INST. INSTRUCTIONS - 44487106 INST. INSTRUCTIONS - 44487106 INST. INSTRUCTIONS - 44487072 INST. INSTRUCTIONS - 44487064 Form C Contacts, 30 VDC, 1 Amp, Resistive Load 2010 Ingersoll-Rand Company 1-877-671-7011 44487023 Rev. 10/10_a 1 of 4

MOUNTING NOTES The PS902 must be installed in accordance with the article 760 of the National Electrical Code or NFPA 72, Canadian Electrical Code, or any other applicable codes. Install the PS902 indoors within the protected premises. Check national and local codes for additional installation requirements. Enclosure must be firmly mounted to a solid surface using hardware suitable for the surface. 1 MOUNT POWER SUPPLY 1a Mark 2 Top Holes 1b Secure Enclosure with 4 Screws x x Board not shown for clarity 2 SECURE ENCLOSURE DOOR If No Keylock Enclosure will be secured with 2 screws as shown (done as last step) If Keylock Remove knockout and insert key cylinder, then slide in clip OR a b 2 of 4

3 PS902 SETUP AND TESTING 3a Connect AC Wiring AC (In) 120/240 VAC Green (Ground) White (Neutral) Black (Hot) NEU LINE AC Input! DANGER: Ensure AC Breaker is Turned Off 900-BB Connector! DANGER 3b Use Jumper to Select 24 VDC or 12 VDC Output 24 VDC Output Setting OR 12 VDC Output Setting F1 High Voltage If main board must be removed, turn off AC power and wait 8 minutes before removal Do not remove this cover, no serviceable parts 24 12 Minimum of 1/4 separation between AC and DC wiring as well as power limited and non-power limited. NC C NO AC Monitor Active when AC present and F1 fuse not open (Form C dry contacts) AC Input (Green LED)! DANGER: If AC LED is off, turn off AC breaker prior to checking F1 fuse Fire Alarm Jumper Remove when 900-FA installed 900-FA Connector 12/24 VDC Output Terminals DC Output (Red LED) 4 INSTALL 900-BB BATTERY BACKUP (IF INCLUDED) 4a Place Batteries in Box with Terminals to the Left Refer to 900-BB instructions for additional info Battery Supervision Terminals (Form C Dry Contacts) NO C NC (Shown AC Off) 4b Attach Wires from Battery Board Red wires = (+) Black wires = (-) Active AC On Inactive AC Off Allow 24 hours for batteries to fully charge Red Wires = (+) + + Battery 1 Battery 2 Black Wires = (-) On-Solid AC On Batteries Charging BB LED (Amber) On-Blinking AC Off Batteries Supplying Power 5 TURN ON AC BREAKER TO TEST POWER SUPPLY Verify AC LED is On = GREEN Verify DC LED is On = RED Verify BB LED (if applicable) is On = AMBER 3 of 4

6 WIRE 900-FA (FIRE ALARM BOARD) IF INCLUDED Terminal Definitions NC C NO FA1 FA2 Refer to 900-FA instructions for additional info If FA is installed on PS902: Supervision Output Contacts Shown FA Active (open) Fire Alarm Input PS902 when fire alarm is active One 900-FA Board - Automatic Reset One 900-FA Board - Manual Reset NC C NO FA1 FA2 NC C NO FA1 FA2 Fire Alarm Contact Closed = no fire Open = fire Manual Reset (Temporarily close to reset) Fire Alarm Contact Closed = no fire Open = fire OPTION BOARDS Refer to appropriate instructions if any board shown below is factory-installed Option Board to be Plugged into Option Connector 900-2Q 900-8F 900-8P NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS (PROVIDED) OR KEYLOCK 4 of 4

! WARNING: F1 DANGER! DANGER:!! WARNING: 44487072 The 900-FA Fire Alarm board can be installed on any one of the following power supply or option boards (refer to installation instructions): 900-FA Fire Alarm Input Installation Instructions Input (Fire Alarm) Dry contacts required (Closed = no fi re alarm) Connect control contacts between FA1 and FA2 Output (Supervision) 30VDC, 1A resistive dry contact Board Input Power Board requires 0.05A max. of power supply output current to operate Temperature Range 32-120 F (0-49 C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring 900-FA board. In the event a fi re alarm is active, this board will remove power from the PS902 DC output and any 900-series option board output. PS902 Power Supply 900-2RS (2 Relay) 900-2Q (2 Relay w/com) If 900-FA was factory installed, go to step 2 If installing to option board, go to 1a If installing to PS902 main board, go to 1b 900-4R (4 Relay) 900-4RL (4 Relay w/logic) 900-8F (8 Zone Distribution-fuse) 900-8P (8 Zone Distribution-PTC) 1a IF INSTALLING TO OPTION BOARD Choose Option Board where 900-FA is to be Installed Remove Jumper from Option Board (900-2RS option board shown) 1 2 3 If using battery backup, location 3 is not available. Install 900-FA to Option Board Option board may be in any of these three locations. 2010 Ingersoll-Rand Company 1-877-671-7011 44487072 Rev. 10/10_a

1b IF INSTALLING TO PS902 MAIN BOARD Remove Jumper Install 900-FA Here Complete power failure shall result in a fail safe operation. When connected to a fire alarm releasing control unit, total loss of power for the locking mechanisms shall be configured for a fail safe operation. 2 900-FA WIRING Terminal Definitions NC C NO FA1 FA2 Use 18 gauge wire for all wiring. Wire length dependent on physical layout. Supervision Output Contacts Shown FA Active (open) Fire Alarm Input One 900-FA Board - Automatic Reset One 900-FA Board - Manual Reset NC C NO FA1 FA2 NC C NO FA1 FA2 Fire Alarm Contact Closed = no fire Open = fire Two 900-FA Boards on one power supply Automatic Reset Manual Reset (Temporarily close to reset) Fire Alarm Contact Closed = no fire Open = fire Two 900-FA Boards on two power supplies Automatic Reset NC C NO FA1 FA2 NC C NO FA1 FA2 NC C NO FA1 FA2 NC C NO FA1 FA2 Fire Alarm Contact Closed = no fire Open = fire Fire Alarm Contact Closed = no fire Open = fire NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK

44487106 This sheet covers: 900-4R 4 Independently Controlled Relays PS-900 Series Option Boards 900-8F 8 Fuse Protected Outputs Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board 900-8P 8 PTC Protected Outputs Page 2 Page 3 Page 4 Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. INSTALL OPTION BOARD(S) INTO POWER SUPPLY a Review Available Board Mounting Locations (gray) b Plug Cable into any Available Option Connector Option 1 PS902 PS902 1 1 Option 1 Option 2 PS904, 914 Option 1 Option 2 Option 3 PS906 PS904 PS914 1 2 (900-4R board shown) c Secure Board(s) with Screws For UL listed installations, use only UL listed locks and strikes PS906 1 2 3 2010 Ingersoll-Rand Company 1-877-671-7011 44487106 Rev. 10/10_a

900-4R 900-4R Specifi cations: Inputs I1-I4 Dry contacts required (Closed = Active) Connect control contacts between SC (Signal Common) and any input Outputs O1-O4 Form C contacts rated 30VDC, 3A (dry) 12/24VDC, 3A (wet) when AC powered 9.6-13.2VDC or 19.2-26.4VDC when battery powered Maximum load cannot exceed power supply ratings or 6A for outputs combined Board Input Power Board requires 0.18A max. of power supply output current to operate Temperature Range 32-120 F (0-49 C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) Function: Four independent dry-contact inputs control four Form C outputs. Powered Outputs (Default) Dry Contact Outputs (Optional) By default, all outputs provide12/24vdc Jumpers factory installed For dry contact outputs, remove appropriate jumpers and rotate 90, then reinstall (Zone 1 - Zone 4) Jumper rotated 90 Zone 2 Output 2 Zone 2 Output 2 Zone 4 Zone 3 Output 4 Output 3 Zone 4 Zone 3 Output 4 Output 3 Zone 1 Output 1 Zone 1 Output 1 LED (each zone) On = input active 900-4R Wiring Example Fail Secure and Fail Safe Electric Strikes Fail Secure Electric Strike 2 Fail Safe Electric Strike 1 Control 2 Control 1 PS902 or PS904 or PS906 NC2 C2 NO2 I2 NC1 C1 NO1 I1 SC 4R 120/240 VAC 50/60Hz NC4 C4 NO4 I4 NC3 C3 NO3 I3 SC 2 Fail secure output only allowed if approved by Authority Having Jurisdiction Refer to Wire Table (page 4)

900-8F 900-8F Specifi cations: Each Output Rated for supply maximum 12/24VDC when AC powered 9.6-13.2VDC or 19.2-26.4VDC when battery powered Maximum load cannot exceed power supply ratings or 6A for outputs combined Board Input Power Board requires 0.045A max. of power supply output current to operate Temperature Range 32-120 F (0-49 C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) F1 - F8 F9 Main Fuse 32V, 7.5A, ATO blade style 300V, 15A, 3AG style! CAUTION: For protection against risk of fi re, replace fuse with same type and rating Function: Provides 8 independently-fused outputs. LED (each output) Off = fuse blown or missing F9 F8 F7 F3 F2 Output 8 Fire Alarm setting (if 900-FA installed) 08 07 06 05 04 03 02 01 Terminals Refer to Wire Table Fail secure output only allowed if approved 3

900-8P 900-8P Specifi cations: Each Output 1.4A maximum 12/24VDC when AC powered 9.6-13.2VDC or 19.2-26.4VDC when battery powered Maximum load cannot exceed power supply ratings or 6A for outputs combined Board Input Power Board requires 0.045A max. of power supply output current to operate Temperature Range 32-120 F (0-49 C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) Function: Provides 8 independent outputs, each protected by an automaticallyresettable thermal fuse. LED (each output) Off = over-current condition Output 8 08 07 06 05 04 03 02 01 Fire Alarm setting (if 900-FA installed) Terminals Fail secure output only allowed if approved Wire table (suggested maximum) Wire Ga (AWG) Device Current (Amps DC) Output* (max. ft) 14 0.3 850 0.5 500 18 0.3 340 0.5 200 Input (max. ft) 1200 *Wiring allows for 10% voltage drop at device current at 12 or 24VDC Max. ft = one way distance between power supply and device NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK 4

Tools for Install 44487098 900-2Q Specifi cations: Inputs I1,I2 QEL Wiring and Configuration Instructions with 900-2Q To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board 1. QEL must be powered by a PS900-Series Power Supply with 900-2Q board 2. QEL requires 18AWG minimum wire. Maximum wire run is 200 between power supply and QEL device. 3. QEL will NOT operate with a Von Duprin 4RL or 2RS power supply board. Dry Contacts required (Closed = Active) Connect control contacts between SC (Signal Common) and any input Outputs O1,O2 24VDC, 3A (wet) when AC powered 19.2-26.4VDC when battery powered May be used with PS914 to power EL device at 24VDC, 16A, 300ms Maximum load cannot exceed power supply ratings or 3A for outputs combined Board Input Power Board requires 0.08A max. of power supply output current to operate Temperature Range 32-120 F (0-49 C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914.! DANGER: ⁵ ₈" Drill Bit 1 DRILL WIRE ACCESS HOLE 1a 1c Drill ⁵ ₈" dia. access hole through device side of door. ⁵ ₁₆" a c b 1b 1d a b 2010 Ingersoll-Rand Company 1-877-671-7011 44487098 Rev. 10/10_a 1 of 4

2 ROUTE TWO WIRES FROM QEL EXIT DEVICE TO POWER SUPPLY QEL Electrical Load PS900-Series Power Supply with 900-2Q Option Board Voltage: Current: 24 VDC 2 A inrush (0.5 sec.) 0.35 A holding 18 AWG required Maximum distance = 200' Electric Power Transfer QEL Exit Device 3 INSTALL 900-2Q OPTION BOARD(S) INTO POWER SUPPLY 3a Review Available 900-2Q Mounting Locations (Gray) 3b Plug 2Q Cable into any Available Option Connector Option 1 PS902 1 900-2Q Board (2 QEL s) max PS902 1 Option 1 Option 2 PS904, 914 2 900-2Q Boards (4 QEL s) max 1 Option 1 Option 2 Option 3 PS906 3 900-2Q Boards (6 QEL s) max PS904 PS914 1 2 3c Secure Board(s) with Screws Power supply model needs to be set to 24VDC to operate this device PS906 1 2 3 2 of 4

4 CONNECT INPUT AND OUTPUT WIRES TO 900-2Q OPTION BOARD Sequential Mode - Typical Wiring wire between I1 and I2 120/240 VAC 50/60Hz 2RS Input I1 will activate both outputs SC I1 01 I2 02 Individual Mode - Typical Wiring 2RS SC I1 01 I2 02 120/240 VAC 50/60Hz Control for Device 2 Input I1 will activate output 1 Input I2 will activate output 2 EPT-2/10 QEL Device 2 (not polarized) EPT-2/10 EPT-2/10 EPT-2/10 allowed if Jurisdiction Control for Devices 1 & 2 QEL Device 1 (not polarized) QEL Device 2 (not polarized) Control for Device 1 QEL Device 1 (not polarized) 5 APPLY POWER TO POWER SUPPLY. IF 900-BB IS USED, THEN RECONNECT BATTERIES 6 SET TIME DELAYS ON 900-2Q BOARD View Current Time Delays Press once Output 1 (green) 1 flash per 5 seconds 1 Output 2 (red) 1 flash per 5 seconds 1 Green/red alternating flash indicates all delays have been displayed Set Delay(s) Press and hold until LED turns green Press once for each 5 seconds desired 2 (Output 1) Wait for red Press once for each 5 seconds desired 2 (Output 2) Wait for green/red alternating flash 1. For example, 2 flashes = 10 seconds. If no delay has been set, no flashes will be displayed. 2. For example, 2 presses = 10 seconds. (Minimum time delay 5 seconds) (Maximum time delay 60 seconds) (Adjustable in 5 second increments) Set All Delay(s) to Zero (0) Seconds. Press and hold until LED turns green Wait for green/red alternating flash 3 of 4

7 CHECK OPERATION a. Activate input(s) and verify all QEL devices operate properly. NOTE: During the first activation, each device will perform a self calibration. This is normal. b. Check LED on the 900-2Q board for the following indications: Output LEDs on 900-2Q Board Solid Flashing Indication Input active Input has been released, and time delay is running c. If any device does not operate properly, see step 8 for troubleshooting. 8 IF NECESSARY, TROUBLESHOOT OPERATION Maintain input and then check for the following indications: NOTE: The setup LED flashes slowly to indicate 900-2Q board is powered. If Output LED on 900-2Q Board is: Off Solid Solid Solid Solid Solid Solid and LED on Device is: Off Off Solid green Flashing green Solid red Flashing red Flashing green/red Indication Problem with input wiring or input device Problem with wiring between power supply and exit device No detectable failures Adjustment in progress Pushpad may vibrate when powered. This indicates that rods or mortise lock are misadjusted. See rod or mortise lock adjustment in installation instructions. If necessary, go to www.vonduprin.com/installation_instruction_library.asp or contact Technical Services at 1-877-671-7011 Contact Technical Services at 1-877-671-7011 Excessive tamper (automatically clears after 2 minutes) Output 1 LED Output 2 LED Setup LED Calibration Button (contact technical services for details) LED on Device 9 REINSTALL COVER AND END CAP a b NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK 4 of 4

44487080 900-4RL Specifi cations: Inputs I1-I4 900-4RL Option Board Dry contacts required (Closed = Active) Connect control contacts between SC (Signal Common) and any input Installation Instructions Outputs O1-O4 Form C contacts rated 30VDC, 3A (Dry) 12/24VDC, 3A (Wet) when AC powered 9.6-13.2VDC or 19.2-26.4VDC when battery powered May be used with PS914 to power EL device at 24VDC, 16A, 300ms Maximum load cannot exceed power supply ratings or 6A for outputs combined Board Input Power Board requires 0.18A max. of power supply output current to operate Temperature Range 32-120 F (0-49 C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) 1 INSTALL 4RL BOARD(S) INTO POWER SUPPLY! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board 1a Review Available 900-4RL Mounting Locations (Gray) Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. PS902 1 1b Plug 4RL Cable into any Available Option Connector Option 1 PS902 1 Option 1 Option 2 PS904, 914 PS904 PS914 1 2 Option 1 Option 2 Option 3 PS906 1c Secure Board(s) with Screws PS906 1 2 For UL listed installations, use only UL listed locks and strikes 3 2010 Ingersoll-Rand Company 1-877-671-7011 44487080 Rev. 10/10_a

2 CHOOSE FUNCTION OF 900-4RL BOARD BY SETTING SW2 DIP SWITCHES ON OFF 1 2 4TD Four Zone Controller Function (4TD): Controls up to four inputs and four outputs with time delay. This is the default setting. Function LED will blink one time every 5 seconds ON OFF 1 2 AO Auto Operator Function (AO): Coordinates the unlocking of one or two zones with the signaling of an auto operator. Function LED will blink two times every 5 seconds SW1 OFF ON Function LED (D17) SW2 1 2 ON OFF 1 2 SI Security Interlock Function (SI): Controls multi-door interlocks. Two through six door systems are possible (additional boards required for three to six doors). Function LED will blink three times every 5 seconds 3 TO COMPLETE CONFIGURATION AND WIRING, GO TO APPROPRIATE SECTION For 4TD: Go to pages 3-4 For AO: Go to pages 5-6 For SI: Go to pages 7-8 Basic Troubleshooting: Go to page 8 (OPTIONAL) DRY CONTACT CONFIGURATION Powered Outputs (Default) By default, all outputs provide12/24vdc Jumpers factory installed Dry Contact Outputs (Optional) For dry contact outputs, remove appropriate jumpers and rotate 90, then reinstall (Zone 1 - Zone 4) Jumper rotated 90 Zone 2 Output 2 Zone 2 Output 2 Zone 4 Zone 3 Output 4 Output 3 Zone 4 Zone 3 Output 4 Output 3 Zone 1 Output 1 Zone 1 Output 1 2

4TD - SET TIME DELAY USING SW1 DIP SWITCHES Summary of Operation Output turns ON when input is activated (closed). Time delay begins when input is released (opened). Locking Device output will remain ON during time delay. If I1-I4 inputs are wired together, outputs will sequence. DIP switches on SW1 can be turned ON by moving them in the direction that the arrow is pointing. Switches below shown in OFF position ON SW1 OFF 1 2 3 4 5 6 7 8 SW1 SW2 12345678 12 Enable Time Delay Allows you to choose which outputs will have the below time delay. Set Time Delay (0-75 seconds, 5 second increments) 0 Sec: Switches 5-8 OFF 75 Sec: Switches 5-8 ON SWITCH NUMBER 4TD DIP SWITCH DEFINITIONS All switches shown in OFF position in wiring diagram 1 Turn ON to enable time delay for Locking Device 1 2 Turn ON to enable time delay for Locking Device 2 3 Turn ON to enable time delay for Locking Device 3 4 Turn ON to enable time delay for Locking Device 4 5 Adds 5 seconds to the time delay when ON 6 Adds 10 seconds to the time delay when ON 7 Adds 20 seconds to the time delay when ON 8 Adds 40 seconds to the time delay when ON 4TD INPUT / OUTPUT TERMINAL BLOCK DEFINITIONS Input 1 Control 1 Input 2 Control 2 Input 3 Control 3 Input 4 Control 4 Output 1* Lock 1 Output 2* Lock 2 Output 3* Lock 3 Output 4* Lock 4 *See page 2 for dry contacts 3

4TD - WIRING EXAMPLE - FAIL SECURE EPT 2 or 10 EL Device 2 (not polarized) EPT 2 or 10 Control 2 PS914 x 4RL NC2 C2 NO2 I2 NC1 C1 NO1 I1 SC 4RL 120/240 VAC 50/60Hz NC4 C4 NO4 I4 NC3 C3 NO3 I3 SC Control 4 EPT 2 or 10 EL Device 4 (not polarized) EPT 2 or 10 EL Device 1 (not polarized) Control 1 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire Control 3 To control EL1 & EL2 with Control 1, jumper I1-I2 To control EL1 - EL4 with Control 1, jumper I1-I2-I3-I4 EL Device 3 (not polarized) Fail secure output only allowed if approved by Authority Having Jurisdiction 4TD - WIRING EXAMPLE - FAIL SAFE Mag Lock 2 Mag Lock 1 Control 2 PS902 or PS904 or PS906 NC2 C2 NO2 I2 NC1 C1 NO1 I1 SC 4RL 120/240 VAC 50/60Hz NC4 C4 NO4 I4 NC3 C3 NO3 I3 SC Control 4 Mag Lock 4 Mag Lock 3 Control 1 Control 3 To control Mag Locks 1 & 2 with Control 1, jumper I1-I2 To control Mag Locks 1-4 with Control 1, jumper I1-I2-I3-I4 4 Refer to Wire Table (page 7)

AO - SET CONFIGURATION USING SW1 SWITCHES DIP switches on SW1 can be turned ON by moving them in the direction that the arrow is pointing. Switches below shown in OFF position ON SW1 OFF 1 2 3 4 5 6 7 8 SW1 SW2 12345678 12 Set Auto Operator Signaling Option Determines when the auto operator signal will be active SW1 SWITCH NUMBER 1 Off 2 Off 1 On 2 Off 1 Off 2 On 1 On 2 On Not Used 3 Not used Set Individual Mode or Sequential Mode Individual Mode - One input will trigger one locking device. Sequential Mode - One input will trigger two locking devices. Set Time Delay* (0-30 seconds, 2 second increments) 0 Sec: Switches 5-8 OFF 30 Sec: Switches 5-8 ON * Time Delay begins when an input is released. AO DIP SWITCH DEFINITIONS All switches shown in OFF position in wiring diagram Operator is signaled when latch monitor switch becomes active. Monitor switch required Operator is signaled 0.5 seconds after control switch becomes active. No monitor switch used. Operator is signaled 1.0 seconds after control switch becomes active. No monitor switch used. Operator is signaled 1.5 seconds after control switch becomes active. No monitor switch used. 4 Turn OFF (default) to enable Individual Mode (single doors). Turn ON to enable Sequential Mode (double doors). 5 Adds 2 seconds to the time delay when ON 6 Adds 4 seconds to the time delay when ON 7 Adds 8 seconds to the time delay when ON 8 Adds 16 seconds to the time delay when ON AO INPUT / OUTPUT TERMINAL BLOCK DEFINITIONS Input 1 Control 1 Input 2 Lock Monitor 1 Input 3 Control 2 Input 4 Lock Monitor 2 Output 1* Lock 1 Output 2* AO Signal 1 Output 3* Lock 2 Output 4* AO Signal 2 *See page 2 for dry contacts 5

AO - WIRING EXAMPLE - TWO SINGLE DOORS Summary of Operation For each door, access control input unlocks door. Latch monitor (LX) triggers auto operator. Single Door Board Configuration 1. Position jumpers for dry contact for outputs 2 and 4 (see page 2). 2. Turn on switches 5 and 6 on SW1 (6 second time delay). 3. If LX is not used, turn on switch 1 on SW1. Auto Operator 1 Gray White LX (Optional) EL EL-LX Device 1 EPT 10 Control for Device 1 PS914 x 4RL NC2 C2 NO2 I2 NC1 C1 NO1 I1 SC 4RL 120/240 VAC 50/60Hz NC4 C4 NO4 I4 NC3 C3 NO3 I3 SC 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire ON OFF SW1 1 2 3 4 5 6 7 8 EPT 10 Control for Device 2 Auto Operator 2 EL Gray White SW2 1 2 LX (Optional) EL-LX Device 2 AO - WIRING EXAMPLE - DOUBLE DOORS Summary of Operation control input unlocks both doors. Both latch monitors (LX) trigger auto operators. Double Door Board Configuration 1. Position jumpers for dry contact for outputs 2 and 4 (see page 2). 2. Turn on switches 4, 5, and 6 on SW1 (6 second time delay). 3. If LX is not used, turn on switch 1 on SW1. Fail secure output only allowed if approved by Authority Having Jurisdiction Refer to Wire Table (page 7) PS914 x 4RL NC2 C2 NO2 I2 NC1 C1 NO1 I1 SC 4RL 120/240 VAC 50/60Hz NC4 C4 NO4 I4 NC3 C3 NO3 I3 SC EPT 10 ON OFF SW1 1 2 3 4 5 6 7 8 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire Auto Operator Gray White Auto Operator White Gray SW2 1 2 Second auto operator, if needed EPT 10 EL LX (Optional) LX (Optional) EL Control for Devices 1 & 2 EL-LX Device 1 EL-LX Device 2 6

SI - CONFIGURE SW1 DIP SWITCHES DIP switches on SW1 can be turned ON by moving them in the direction that the arrow is pointing. Switches below shown in OFF position ON SW1 OFF 1 2 3 4 5 6 7 8 SW1 SW2 12345678 12 Enable Time Delay Allows you to choose which outputs will have the below time delay. Enable Interlock Set Time Delay (Output Active)* (0-30 seconds, 2 second increments) 0 Sec: Switches 5-8 OFF 30 Sec: Switches 5-8 ON SI INPUT / OUTPUT TERMINAL BLOCK DEFINITIONS Input 1 Control 1 Input 2 Control 2 Input 3 Lock Monitor 1 Input 4 Lock Monitor 2 Output 1* Lock 1 Output 2* Lock 2 Output 3* Follows Output 1 by.5 Sec Output 4* Follows Output 2 by.5 Sec *See page 2 for dry contacts SWITCH NUMBER SI DIP SWITCH DEFINITIONS All switches shown in OFF position in wiring diagram 1 Turn ON to enable time delay for Locking Device 1 2 Turn ON to enable time delay for Locking Device 2 3 Turn ON to remove O2 from interlock (Allows a single independent door) 4 Turn ON for global interlock (interlocks with other SI boards that have this switch ON ) 5 Adds 2 seconds to the time delay when ON 6 Adds 4 seconds to the time delay when ON 7 Adds 8 seconds to the time delay when ON 8 Adds 16 seconds to the time delay when ON SI Board #1 GLOBAL INTERLOCK SWITCH SETTING EXAMPLES SI Board #2 SI Board #3 Application SW1-3 SW1-4 SW1-3 SW1-4 SW1-3 SW1-4 Off Off Off Off Off Off Each SI board is a standalone, 2-door interlock. Off On Off On Off On 6-door interlock by setting all boards global. Off On On On A three-door interlock, plus an additional independent door on output 2 of SI Board #2. Off On Off On Off Off 4-Door interlock (SI Board #1,2) and a standalone 2-door interlock (SI Board #3). Wire table (suggested maximum) Wire Ga (AWG) Device Current (Amps DC) Output* (max. ft) Input (max. ft) *Wiring allows for 10% voltage drop at device current at 12 or 24VDC 14 0.3 850 0.5 500 Max. ft = one way distance between power supply and device 18 0.3 340 0.5 200 1200 12 Using EL device with EPT or Door Loop 200 14 (PS914 required) 100 12 Using EL device with Electric Hinge/Pivot 150 14 (PS914 required) 75 7

SI - WIRING EXAMPLE - 2 TO 6 DOOR INTERLOCK, NORMALLY LOCKED SI Configuration 1.Turn on switches 1, 2, 4, 5, and 6 on SW1. 2. Install 2 doors per SI board. 3. Add up to 2 additional SI boards for a total of 6 door interlock per power supply: PS902 (2 doors maximum) PS904 (4 doors maximum) PS906 (6 doors maximum) Mag Lock 2 DPS 2 (contact shown with door closed) Control 2 PS904 x 4RL NC2 C2 NO2 I2 NC1 C1 NO1 I1 SC 4RL 120/240 VAC 50/60Hz NC4 C4 NO4 I4 NC3 C3 NO3 I3 SC ON OFF SW1 1 2 3 4 5 6 7 8 DPS 1 (contact shown with door closed) Control 1 Mag Lock 1 SW2 1 2 Fail secure output only allowed if approved by Authority Having Jurisdiction Refer to Wire Table (page 7) BASIC TROUBLESHOOTING FOR ALL FUNCTIONS Symptom 900-4RL Function LED (yellow) is not blinking, and inputs and outputs are inactive 900-4RL Function LED (yellow) is blinking, but inputs and outputs are inactive Inputs and outputs behaving incorrectly. Check Verify 900-4RL cable is plugged into an option connector on the main board. Check AC wiring and AC breaker. Check PS-900 main board F1 fuse. Use voltmeter to verify 12 VDC or 24 VDC output on PS-900 main board. If 900-FA option is installed onto 900-4RL, verify fi re alarm contacts are closed across FA1 and FA2. If 900-FA option is not installed, then verify jumper wire is installed into FA-JMPR connector on the 4RL board. Verify 2-position DIP switch is set for proper function. Watch yellow LED to confi rm 4RL function setting. See page 2. (Verify each DIP switch is pushed into its fully-on or fully-off position.) Verify 8-position DIP switch is set properly for your application. If you are unsure of proper settings, contact Technical Services for assistance. (Verify each DIP switch is pushed into its fully-on or fully-off position.) Verify wiring for all input and output hardware is connected to proper terminals. (Reminder: If 900-4RL is mounted in location 1, top terminals will be. If 900-4RL mounted in location 2 or 3, top terminals will be SC.) NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK 8

44487064 900-BB Battery Backup Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring 900-BB board BATTERY SPECIFICATIONS Battery Life Model PS906 = 6A @ 24V } Model PS904 = 4A @ 24V Suitable for Canadian Class IV standby power for access control Model PS902 = 2A @ 24V Model PS914 = 4A @ 24V Battery Type 12VDC, 7Ah Gel Sealed Rechargeable Battery (2 included) 5 Year Service Life Replacement Part Number Schlage 991280! CAUTION: Charge only Schlage 991280 batteries. Other types may burst, causing personal injury and damage. Observe the proper polarity when connecting the batteries. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. 1 INSTALL 900-BB ONTO MAIN CIRCUIT BOARD AND SECURE WITH SCREW Plug Connector Here (PS914 main board shown) Secure with Screw Here 2010 Ingersoll-Rand Company 1-877-671-7011 44487064 Rev. 10/10_a

2 INSTALL AND CONNECT BATTERIES 2a Turn On AC Breaker to Energize Power Supply 2b Place Batteries in Box with Terminals to the Left Battery Supervision Terminals (Form C Dry Contacts) Active NO C NC Inactive (Shown AC Off) AC On AC Off 2c Attach Wires from Battery Board Red wires = (+) Black wires = (-) 2d Verify That Battery LED is On If LED is not on, cycle AC power off and then back on. Allow 24 hours for batteries to fully charge Red Wires = (+) + + Battery 1 Battery 2 Black Wires = (-) On-Solid AC On Batteries Charging BB LED (Amber) On-Blinking AC Off Batteries Supplying Power! WARNING: Incorrect connection may cause damage to the batteries NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK