Propaq LT Outline Train the Trainer

Similar documents
Atlas Monitor Outline Train the Trainer

BeneVision TM80 Telemetry Monitor

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

T1 BEDSIDE MONITOR GUIDELINE

1 Appendix - Product Specifications

HeartStart XL+ Configuration Worksheet

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

Omni (K) PATIENT MONITOR

OMNI TOUCH SCREEN PATIENT MONITOR

DPM Summary of Features and Benefits

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

PM-9000 Express Portable Patient Monitor

PATIENT MONITORING SYSTEMS

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

BeneVision Central Monitoring System. Quick Reference Guide

SERVICE MANUAL YM6000 Patient Monitor

Clinical Information Center Pro v5 (CIC Pro)

QAM.L L550 series. Patient Monitor Manual QAM.L

Connex Integrated Wall System 2.2 Software Version

Multi-Parameter Patient Monitor

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

Multiparameter. er Monitor DM

General Skills. yes. Device controls, buttons, indicators, and connectors

Connections That Last

Veterinary Portable Multi-parameter Patient Monitor. Operation Manual

SECTION L MONITORING EQUIPMENT

HBP Patient Monitor. Operator s Manual. EU representative OBELIS S.A Bd. Général Wahis, Brussels, Belgium.

BEDSIDE MONITORING Dash 3000/4000 V5

Vitalmax 4000 CL Product Specifications

MRI Patient Monitoring System (Model )

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

T1 Monitor/Module Default Settings

Patient Monitoring System YM5500. Service Manual

DPM4 Bedside Monitor Default Settings

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

and Mobile Acuity LT Central Monitoring Systems

User s Guide. Cardell Touch Veterinary Vital Signs Monitor. For Models:

SOFTWARE VERSION 8.5 FAQs

User Guide. Cardell Insight Veterinary Monitor. For Models: 8014 Blood Pressure Blood Pressure, Pulse Oximetry

Guide, Quick Start, Short, X-100 System

INSTRUCTIONS FOR USE. IntelliVue X2. Multi-Measurement Module Release G.0 with Software Revision G.0x.xx. Patient Monitoring

OMNI. Patient Monitor USER S MANUAL

Propaq M Operator s Guide

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

The information in this document is subject to change without notice.

Instructions for Use Vista 120

PATIENT MONITORING SYSTEMS

PATIENT MONITORING SYSTEMS

Multi-parameter Patient Monitor STAR8000H. User Manual

INSTRUCTIONS FOR USE. IntelliVue Patient Monitor. MP5 Release G.0 with Software Revision G.0x.xx. Patient Monitoring

THE CLINICAL CONNECTION

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

BeneVision TMS60. Telemetry Monitoring System. Operator s Manual

PM Portable Multi-parameter Patient Monitor. Operation Manual

DPM 4 Patient Monitor. Operator s Manual

Fire Command Keypad. XR5 User s Guide

GIMA VITAL SIGNS MONITORS VITAL PRO-SNET

Syringe Pump. User Manual

Multi-parameter Patient Monitor Operator s Manual

BM3VET User Manual Code Veterinary Monitor Rev. 2.4

qube mini Overview

T1 Patient Monitor. Operator s Manual

Infinity M300 Patient Worn Monitoring

ANGELUS (Ver 2.03) Patient Monitoring System

SERVICE MANUAL. Patient Monitor M30. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

SPECIFICATION FOR MULTIPARAMETER MONITOR

Vital Signs Monitor PC-900. User Manual

User s Manual. Multiparametric Vital Sign Monitor

Infinity M300+ Telemetry

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

M9500 Patient Monitor User s Manual

Vital Signs Monitor. Operator s Manual

Vital Signs Monitor 300 Series

PAT I E N T M O N I TO R I N G N E T W O R K

Vital Signs Monitor 300 Series

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

OMNI Express VS VERSATILITY IN VITAL SIGNS

CLEO VERSATILITY IN VITAL SIGNS

SECTION L MONITORING EQUIPMENT

Vital Signs Monitor 300 Series

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

Ultraview SL2400 With Wireless-LAN-Option

L505. Patient monitor user manual. Technology that doesn t miss a beat. Tel:

Alarm and Measurement Default Settings

N-600. Pulse Oximeter Home Use Guide

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

IntelliVue Cableless Measurements

ARGUS LCM. Patient monitor ARGUS LCM and ARGUS LCM PLUS. Operating Instruction. Art. no.: rev.: d

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

Product Specifications

TOUBRO LIMITED ELECTRICAL & ELECTRONICS DIVISION - ELECTRONIC PRODUCTS 510(K) SUMMARY. (Per section )

Model 900. Pulse Oximeter User s Manual

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

DYGIZONE GJD910 Lighting Controller & Enunciator

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Checkout Procedure Manual

Addendum to the Instructions for Use

CREATIVE MEDICAL. PC-3000 Multi-Parameter Monitor

TidalGuard HD. Handheld CO 2 / SpO 2 and CO 2 monitors. Operating Manual Rev. H (8/15)

Quick start guide. English

Transcription:

Train the Trainer A. Propaq LT and LTR Propaq LT Standalone monitor Propaq LTR Monitor that has the wireless Acuity feature enabled 1. Lightweight (Less than 2 pounds) 2. Uses rechargeable lithium ion battery 3. Compatible with 3 or 5 lead ECG cables 4. Neonatal, pediatric and adult modes 5. One or Two ECG channels displayed 6. Color LCD screen for display of numerics and waveform data 7. Rugged and tolerant of brief water exposure 8. Do not clean ECG leads with alcohol 9. Store monitor in cradle when not in ambulatory use 10. Show the exterior connections for ECG/RESP, NIBP, SPO 2, Battery/Charger Cradle Cradle B. Propaq LT Buttons 1. Suspend/Resume Alarm: 2. Changes display format (3 views): 3. Arrow buttons move the cursor on the display: 4. Select the highlighted item or confirm a choice: 5. Start/Stop NIBP: 6. Record full disclosure snapshot: 7. Color transflective LCD screen is viewable in all indoor/outdoor settings. 1

8. Flashing green LED: indicates normal operation 9. Flashing yellow LED: indicates equipment alert 10. Continuous yellow LED: indicates an alarm limit is disabled 11. Flashing red LED: indicates patient alarm 12. Continuous red LED: indicates a patient alarm is suspended C. Propaq LT/Acuity Setup Procedure 1. Apply ECG leads/spo 2 /NIBP cables on the patient first 2. Press the power button to apply power to the monitor 3. To prepare for a new patient, highlight Start a New Patient, then press Select. 4. Use the arrow buttons and Select to enter the patient s name and ID (or ID at Acuity) 5. Check the patient mode and make sure it is correct. If not, use the arrow keys to scroll to highlight the existing patient mode. Then press Select, and change to the correct patient mode. D. Tips for successful ECG monitoring 1. Using pre-gelled silver/silver chloride electrodes is recommended. Electrodes with dissimilar metals can prevent obtaining an ECG tracing and can compromise recovery time after defibrillation. 2. Prepare electrode sites (skin preparation): a. Remove hair from electrode sites. Shave or clip hair according to hospital policy b. Thoroughly clean skin where electrodes will be attached and lightly rub dry c. Use soap and water, isopropyl alcohol, or special skin preparation pads to cleanse the skin d. To avoid allergic reactions to electrodes, refer to the electrode manufacturer s guidelines 3. Proper electrode placement a. Increased artifact due to patient movement greatly affects telemetry monitoring b. Place electrodes in flat areas; avoid fatty/bony areas and major muscles 4. Suggested lead placement: RA (white)-place near right mid-clavicular line directly below the clavicle LL (red)-place near 7 th intercostals space in line with or lateral to the midpoint of the left clavicle LA (black)-place near left mid-clavicular line directly below the clavicle. RL (green)-place near 7 th intercostal space in line with or lateral to the midpoint of the right clavicle C (brown)-place in the intercostal space equivalent to the V1, V2, V3, V4, V5, or V6 position you want to monitor 5. Always attach lead wires to electrodes before applying to patient. Confirm that the Propaq LT displays the ECG waveform, heart rate, and other patient data. If the Propaq LT detects that some lead wires are not properly connected, the Propaq LT indicates which leads are disconnected. 6. Electrodes should be replaced when loose and daily after bathing (according to policy). 7. Contributors to a poor ECG tracing: Not properly supporting a patient s monitor Dried Electrodes Placing an electrode on site affected by motion Hair at electrode sites Using electrodes with dissimilar metals 2

Note: Use stress loops to help decrease artifact (demonstrate guidelines) We recommend inserting the ECG and/or SpO 2 cables into top of Propaq LT to monitor patient at this time. This will decrease the number of equipment alerts and potential alarms. 8. Three methods of ambulating with the Propaq LT: a. Carrying strap b. IV Pole mount c. Patient wearable: Place strap on patient first, connect the strap securely to each side of the Propaq LT monitor, carefully arrange the strap and monitor on the patient (hand bag design). E. Alarms 1. There are 6 alarm parameters that can be set and adjusted on the Propaq LT 2. Once you have your Propaq LT monitor on, use your arrows keys and select key to highlight the blue bell icons on the bottom of the LCD screen 3. You must highlight/underline the Blue bell icon or parameter label that represents the following alarm parameter that you wish to change -- Heart Rate numeric (Green), Systolic BP (Aqua), Diastolic BP (Aqua), Mean BP (Aqua), Respiratory (Purple), Pulse Ox (Yellow). 4. Once you highlight the parameter (for example: HR), you then press the select key (icon), or use your up/down arrows to scroll up and down the menu, you use your left/right arrow keys to increase/decrease the numeric limits 5. A solid blue bell indicates that the lower and upper limits are on for that parameter 6. A half solid blue bell indicates that one limit is turned off; if the left half of the blue bell icon is empty, then the upper alarm limit is off and if the right half of the blue bell icon is empty that means the lower alarm limit is off. 7. An empty blue bell indicates that alarms parameter is completely turned off (upper and lower limits) You will also see the Yellow light on the front of the monitor stay on continuously 8. Managing Alarms: a. Suspend the alarms b. Paramset c. Manually adjusting the alarm limits F. Propaq LT MENU s 1. TRENDS Menu: a. Press Select to display the control settings b. Scroll to Trends and press Select to display the trends c. The Trend Viewer allows you to select and view each of the available trends in either tabular or graphical format 2. SNAPSHOTS Menu: a. Press Select button to display the control settings b. Scroll to Snapshots and press Select to display the Snapshot viewer c. The Snapshot Viewer allows to you select and view each of the available Snapshots (max is 20 snapshots) 3. SET UP Menu: a. Press Select button to display the control settings b. Scroll to Setup and press the Select button c. This will take you to Setup Menus for: ALARMS: To set alarms 3

ECG: Menu for Bandwidth, Filter, Pacer NIBP: Menu for Format, Units, Smartcuf TIMINGS: Menu for Backlight Timeout, Display Timeout, Demo SERVICE: Menu for qualified personnel d. Silence Audio Alarms: Options of times to choose from to silence alarms e. Alarm Tone: OFF, LOW, MED, HIGH Option to choose tone G. ECG Lead/Vector Menu 1. Highlight the green colored vector - there are 7 options of vectors: Lead I, II, III, AVR, AVL, AVF, V 2. Press the Select button to obtain a drop down menu of vectors that can be viewed (6 seconds at a time) 3. The Resp (24 seconds) and SPO 2 are two other waveforms that can be viewed 4. The Add 2 nd Wave Option is available for the user to view 2 waveforms at the same time on the LCD screen H. Battery Management Charging Light 1. Recharge a Battery a. Confirm that the green LED (on the right) is on at the charging station, indicating that AC power is connected b. Slide the monitor all the way down into the Charging station until the monitor clicks into place c. Confirm that a green LED (on the left) is on at the Charging station. This indicate the battery is now charging d. When the battery is fully charged, the green LED (on the left) is off. e. Message: LOW BATTERY: < than 30 minutes, VERY LOW BATTERY: < than 15 minutes 2. Inspect and Clean the Monitor and Accessories a. To clean the Propaq LT, Charging station, Accessories: Wipe with equipment with a nearly dry cloth moistened with one of the approved cleaning solutions in the Directions For Use manual. b. Do not let the cleaning solution run into connector openings, latches, and crevices. 4

I. Monitoring with Wireless Network (from Acuity SW 6.4 to present) 1. Your monitor should automatically display an antenna symbol,, indicating the status of network connection. 2. After the monitor is connected to the network, the following data must be completed at the monitor: Patient name, Patient ID, Room # 3. If you did not specify the patient information at the monitor before network connection, the monitor will present a series of menus and messages requesting the information. For example: Select an Acuity Unit Select a patient from the patient list Select a patient room from the patient list 4. Patient out of network: A DROPOUT equipment alert occurs at the Acuity Central Station An equipment alert occurs at the monitor with the message Acuity Connection Lost press Select to acknowledge this alert When the patient returns within range of the network, the monitor automatically reconnects to the network 5. Disconnect from the Network: Highlight the wireless status symbol,, then press Select Scroll to highlight Disconnect, then press Select and confirm your selection to disconnect 6. Reconnect a Recently Monitored Patient to the Network Highlight the wireless status symbol, then press Select The monitor will want the user to provide information-acuity unit, patient name, room #. This is a user responsibility!! J. Configurator Options: The monitor can be configured in the following ways: 1. Each facility can define a custom default configuration for its monitors so that the monitors conform to the local requirements. 2. Clinicians can temporarily adjust settings to meet the needs of individual patients. While monitoring a patient, you can temporarily adjust many of the monitor settings to accommodate the needs of a specific patient. These patient-specific settings persist until they are changed manually or by Acuity or until the monitor is powered down and then powered up to monitor a different patient. 3. When a wireless monitor is in communication with an Acuity Central Station, Acuity imposes several monitor settings to assure conformance and consistency among all monitors on the network. These settings override the factory configuration, the default configuration, and any temporary patient-specific settings. When the monitor comes into communication with the Acuity Central Station, Acuity uploads values to the monitor for the following parameters: NOTE: The Acuity-defined configuration persists until the monitor moves out of range of the Acuity network or until the monitor is powered down and powered up. HR/PR source can disable HR/PR alarm limits power source filter HR/PR upper and lower alarm limits (adult, pediatric, and neonate) NIBP mode systolic upper alarm limit (adult) o Diastolic upper alarm limit (adult) o Systolic lower alarm limit (adult) 5

o Diastolic lower alarm limit (adult) o Mean upper alarm limit (adult) o Mean lower alarm limit (adult) NIBP auto interval o Smartcuf On default (adult) o Smartcuf On default (pediatric) o Smartcuf On default (neonate) o SpO2 upper and lower alarm limits (adult, pediatric, and neonate) Respiration on/off respiration vector select (adult, pediatric, and neonate) Respiration upper and lower alarm limits (adult, pediatric, and neonate) Patient name room number Language buttons lock-out enable Back light time out ECG bandwidth 6