Mu-copper Faraday cages

Similar documents
Universal Shielding Corp.

RF EMI PORTABLE ENCLOSURE OPTIONS. Vestibule / Foyer - internal or external. RMEC0004 Canvas Carry Bag for enclosures 40 x 20 x 20

EMC Bayswater Pty Ltd

DESIGN PRODUCTION INSTALLATION MAINTENANCE OF RF CAGES AND AIR CONDITIONING SYSTEMS FOR MR ROOMS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

FEB. 17 Rev. A1

ISIS Design Division Electrical Engineering. S Birch. September 2012.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

Document Information Cover Sheet

CONTACT US AVIONICS & CONTROLS ADVANCED MATERIALS SENSORS & SYSTEMS

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Sunlight Supply, Inc.

MRI SOLUTIONS RF SHIELDING MRI SAFETY ENGINEERING SERVICES YOUR IMAGE IS SAFE WITH US

CERTIFICATE OF ACCREDITATION

ASPIRE Laboratory Aspirator

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ESD BASICS. Basic Concepts in ElectroStatic Discharge (ESD) Copyright 2005 DESCO INDUSTRIES INC. 9/05

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

Visqueen Vapour Control Tapes

SPECIAL SOLUTIONS. AE/PS EMC Enclosure Solutions... SPE 1-2. EMC Compatibility... SPE 3-4. Seismic/Zone 4 Applications... SPE 5-6

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

PM2.5. Summary of MEDAIR 4 Models. Air Treatment Unit Indoor Air Quality solution specialist

Instruction Manual (Supplementary) Open Type Inverter

STS Directory Accreditation number: STS 0009

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Multi Layer Varistor Overvoltage Protection Device

E529 Smart Digital Thermostat Product Guide

Q1 - Q2 - Q3 - Q4 Q2

PAL-245 Precision Architectural Loudspeakers

Questions on Installation? Call: 800.GE.CARES (US) WARNING RISK OF FIRE 4" DIA. METAL DUCT (RECOMMENDED) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Pellet Stove. Flex Pipe. Appliance Connector

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

M7100 Pressure Transducer

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

PAL-80, PAL-65, PAL-45 Precision Architectural Loudspeakers

Banda Cay Wallpaper. eskayel.com T South 6th Street Brooklyn, NY 11249

PAL-265 Precision Architectural Loudspeakers

DD15 Interface Module Product Guide

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

HIGH SECURITY VAULT DOORS. A complete line of high security attack-resistant vault doors and accessories. AN ISO 9001 CERTIFIED COMPANY

A ROUGH GUIDE TO CONSTRUCT A PASSIVE SOLAR AIR HEATER

Two (2) Side Rail Cable Tray

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Energy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation

BDM Direct Vent systems are for use with direct vent gas fired appliances.

MECHANICAL FIRE STOPPING SOLUTIONS

CERTIFICATE OF ACCREDITATION

Kalos Cameo Wallpaper

CABINET PARTS For Model: IRT (White)

Caledonian Fire resistant Coaxial Cables

AUGUST 2016 CONTENTS:

Laurel Forest Punta Grasscloth

Solatube Daylight Dimmer Installation Instructions

Always make sure to check the heating film before, during, and after installation of the floor covering.

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

Aerospace/ Military Thermal Management Systems Selection Guide

HOT AIR GUN MODEL NO: CHG1500D USER INSTRUCTIONS PART NO: GC0414

CABINET PARTS For Model: IST (White)

Be inspired... hanging wallpaper. CONTACT US ON 0861 SHAVES OR VISIT OUR WEBSITE AT FOR A STORE NEAR YOU

Please read operating instructions carefully before use and keep it for further reference.

C08. S05. P02 P05 Decorative effects

Energy-saving tips. For apartments and condos. pse.com/multifamilyretrofit. Bellevue, WA Puget Sound Energy. P.O. Box /17

Madagascar Sky Blue Wallpaper

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

WF2000 Inbuilt WF2000 Console

B-LINE SERIES. Product brochure. Firestop

FAN ENGINEERING. Sealing of Fan Housings

Custom Series In-Wall and In-Ceiling Loudspeakers

MONTAGE INSTRUCTIONS OF HEAT DECOR S HEATING FILM BELOW CONCRETE OR TILES

Do you know what you re getting into?

Safety Standards for Electronic Products

WESTINGHOUSE ELECTRONICALLY CONTROLLED A SERIES COMPACT SIDE BY SIDE REFRIGERATORS

Q3000 Smart Home Alarm. Kit Content and Installation Guide

Heating Mats. Single-side power supply Double-side power supply

Installation Electric Dryers Instructions 01

MICROELECTRONICS CAPABILITIES & PRODUCTS

DRYER INSTALLATION INSTRUCTIONS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Modular Radiant Panel

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

JGK-MS-2/3 Jacketed Concentric Neutral Cable Mid-Span Grounding Kit

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Compliance Engineering Ireland Ltd

WM-4510HZD Installation Instructions

SolderSleeve Insulated Electrical Termination Devices

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

The Prevention and Control of Electrostatic Discharge (ESD)

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

Transcription:

Mu-copper wall covering system Mu-Copper foil has high attenuation properties in the electrical field (up to 120 db) as well as in the magnetic field (see shielding performance table). It is easy to apply, like wallpaper, thanks to its special adhesive for walls, ceilings and floors. The interior finish can be plaster board, foam tiles or plywood. The 0.12 mm thick Mu-Copper is used to transform a regular room into a shielded room; the product has excellent shielding performance even at low frequencies. The system is easy to mount on shielded doors with clamping devices. The standard width of Mu- Copper is 1000 mm; the foil can be delivered on rolls or as ready-made sheets. Mu-copper Faraday cage, Mu-copper wall covering system Overlap options For the joints you can use a 50 mm overlap. For extra high performance you can fully solder the joints or use a seaming /copper tape with a conductive self-adhesive to apply over the joints. Mu-copper wallpaper overlap options Advantages Cost-effective / takes up little space Light weight / high floor load Can be constructed with local labour Standard interior finish possible like plasterboard Can be delivered with 10 year guarantee Maintenance free Delivery with turnkey measurement report Shielding performance 1 Mu-copper Faraday cage shielding performance Basic values for the material and Mu-copper cage These values are measured under laboratory conditions. In other situations, results may differ; please read our Guarantee.

Field Frequency Mu-copper H 1 khz 22 db H 10 khz 33dB H 200 khz 68 db E 10 khz 99 db E 200 khz 127 db E 1 MHz 125 db E 18 MHz 101 db P 400 MHz 120 db P 1 GHz 110 db P 10 GHz 120 db Shielding performance of mu-copper foil 0.12 mm thick These values are measured under laboratory conditions. In other situations, results may differ; please read our Guarantee. Measurements according to MIL STD 285 and the following situation: Mu-copper foil 0.12 mm thick, fully soldered Dimensions 10 x 6 x 4 m 1 Door 0.9 x 2.1 m 2 Ventilation panels 4 Power filters You can create a Faraday cage with high shielding performance yourself in an economic way, using local labour. This is possible in existing buildings as well as in new ones, without loss of space. Depending on the quality of the doors, vent panels, filters and/or windows used, attenuation levels up to 80-100 db in the E-field can be realized. When more layers are applied, it is possible to achieve over 120 db. Ventilation For ventilation we have developed honeycomb ventilation panels. Especially for the Mu-copper Faraday cages we can deliver honeycomb vent panels with a Mu-copper flap around the edges. It is easy to solder these into the Mu-copper Faraday cage. Honeycomb ventilation panels with Mu-copper flap For other honeycomb ventilation panels, see our Honeycomb ventilation webpage. 2 Ceiling The system can be used with a detachable or fixed ceiling to separate existing ducts and cables from the shielded room.

Mu-copper Faraday cages Mu-copper detachable ceiling Mu-copper detachable ceiling construction Applications 3 EMI shielded server room Revision date: 11-04-2016

EMI shielded MRI room Server rooms EMC test rooms Computer rooms Medical examination rooms MRI, EEG, EMG EVP Rooms for physiotherapy Radar protection/airport TEMPEST Sites Military EMC protection Board room shielding Industrial espionage/ Secure room Buildings for intelligence agencies For more information, please download the datasheet "Medical solutions" Modified RF shielded door 4 Shielding Faraday cage sliding door When a lower performance of e.g. 40-60 db is acceptable, we can retrofit your existing door. The door is then equipped with gaskets at the top and sides, and with a conductive copper brush and doorstep at the bottom. Both swinging and sliding doors are suitable for being shielded this way.

For heavy duty applications we can supply Faraday cage doors that offer up to 140 db reduction. For more information see our Faraday cage doors webpage. Components In addition to EM shielded doors and windows, the screened rooms can be equipped with the following components: Shielded doors Shielded windows Shielded ventilation panels Power and signal filters We also offer shielding solutions for water pipes, medical gases, and ventilation when needed. Mu-copper Faraday cage example projects Project: University Amsterdamtest labaratory Project: Animal hospital Belgium, Horse MRI room Partnumber / Ordercode: XXX.. XXX.. XXX Sample of Partnumber: 60.. WA.. WS * Note: The red blocks are required 5