Journal of Physics: Conference Series. Related content. To cite this article: S Gendebien et al 2012 J. Phys.: Conf. Ser.

Similar documents
PERFORMANCES OF DAHT CONNECTED TO BUILDING AIRTIGHTNESS AND INDOOR HYGRO- THERMAL CLIMATE

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

Purdue e-pubs. Purdue University

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Low GWP Refrigerants for Air Conditioning Applications

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

DRYING YELLOW-POPLAR IN A SOLAR-DEHUMIDIFIER KILN WITH HEAT STORAGE AND HEAT RECOVERY SYSTEMS

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Compression of Fins pipe and simple Heat pipe Using CFD

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

2. HEAT EXCHANGERS MESA

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

A WET-VAPOUR INJECTION AND VARIABLE SPEED SCROLL COMPRESSOR AIR TO WATER HEAT PUMP MODEL AND ITS FIELD TEST VALIDATION

Injection with front ends open at the ESRF

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Evaluation of moisture content in drying of grated coconut meat using grain moisture meter

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Pharmaceutical Facility Design

Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Effects of seawater flow rate and evaporation temperature on performance of Sherbet type ice making machine

Evaluation the Effect of Washing on the Heat Transfer Capacity and Air-Side Flow Resistance of Air Cooled Condensers

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Air Liquide Advanced Technologies Division Sassenage, 38360, France

A660 Air Conditioning Laboratory Unit

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Recent Advances in Energy, Environment and Economic Development

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

Low Global Warming Refrigerants For Commercial Refrigeration Systems

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

How Wicks and Orientation

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

Challenges and Methods of Estimating a Conceptual HVAC Design

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Study on a novel variable capacity technology and control strategy for refrigerated shipping container unit

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Simscape Refrigerant Loop Product

VERSO Air Handling Units

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Appendix 13. Categories of Cooling and Heating systems

This document is a preview generated by EVS

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Closed Circuit Cooling Towers

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Solar Drying of Fruits and Vegetables

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Transcription:

Journal of Physics: Conference Series Experimental investigation on a decentralized air handling terminal: procedure of aeraulic and thermal performance determination of the entire unit in several operating conditions To cite this article: S Gendebien et al 2012 J. Phys.: Conf. Ser. 395 012061 Related content - Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers M Kessler and S Kabelac - Experimental Investigation of Microstructured Evaporators W Wibel, S Westermann, S Maikowske et al. - Buoyancy driven flow in counter flow heat exchangers C O Olsson View the article online for updates and enhancements. This content was downloaded from IP address 37.44.204.9 on 12/12/2017 at 09:17

Experimental investigation on a decentralized air handling terminal: procedure of aeraulic and thermal performance determination of the entire unit in several operating conditions S Gendebien 1, L Prieels 2, V Lemort 1 1 Thermodynamics Laboratory, University of Liège, Belgium 2 Greencom Development SCRL, Liège Belgium E-mail: sgendebien@ulg.ac.be Abstract. A new local ventilation device is actually developed in such a way to procure ventilation on demand in each room, with a maximal effectiveness. It consists in a wall or window frame mounted plane-parallel box, containing two (injection and extraction) fans, an electronic control, and a heat recovery exchanger. The present paper describes the experimental investigations carried out on some single components and on the entire unit in order to characterize the aeraulic and thermal performance of the device. 1. Introduction Nowadays, important efforts are deployed to reduce the actual residential building energy consumption. The most common retrofit option concerns the thermal insulation and the air tightness improvement. However, this latter retrofit option could decrease the air indoor quality because of a reduction of air infiltration flow rate. Installation of heat recovery ventilation allows for an efficient combination between consumption reduction due to the air tightness improvement and acceptable air indoor quality. The principle of such system is very simple: vitiated air, extracted from the building is used to pre-heat (in winter) or pre-cool (in summer) the fresh air flow rate coming from the outdoor environment. Most of commercialized units are centralized, which involves a high number of air extracting and air pulsing ducts through the house. From this fact, centralized units are not well adapted to refurbishment because of the absence of room dedicated to pulsing and extracting ducts in existing buildings. The present paper describes the experimental apparatus developed to characterize the aeraulic and thermal performance of a decentralized air handling terminal (DAHT). Experimental investigations have been carried out on some single component (such as heat recovery exchanger or the fan) of the device but also on the entire unit in order to determine the flow rate it delivers. The first part of the paper presents and describes characteristics of the new local ventilation device. The second part of the paper presents the experimental apparatus developed to characterize the thermal and the aeraulic performance of the unit. Some experimental results are given. Finally, the discussion section presents the under-development test bench to determine the thermal performance of the entire unit in several operating conditions, such as freezing ones. 2. Presentation of the investigated device Published under licence by Ltd 1

2.1. Context and advantages The principle of heat recovery ventilation is well-known and rather widespread, but most of already commercialized units are centralized, which involves a high number of air extracting and air pulsing ducts through the house. Figure 1 : Comparison between a centralized and a decentralized air handling unit Usually, vitiated air is extracted from wet rooms such as bathroom, kitchen and fresh air is pulsed into dry rooms such as living room, bedroom. This system is commonly known as Controlled Mechanical Ventilation (CMV) or system D with heat recovery. As observed in Figure 1, the main advantage of the decentralized unit is the suppression of the ducts, and the easiness of placement of the units, especially after a refurbishment. But this advantage involves a considerable challenge: developing a very compact heat recovery device with a high thermal efficiency despite of a small volume. Attention has also to be paid to aeraulic performance, which has to be maximized in order to minimize the fan consumption (lower than 25 [W] expected, for the highest delivered flow rate) and hence, the generated noise. In the design step of this kind of device, it is important to keep in mind that the heat recovery device will be installed in rooms and has to be as silent as possible. According to the NBN S01-400-1 [1], the normal acoustic comfort for life and bed rooms are respectively 30 [db] and 27 [db]. For a considered superior acoustic comfort, 27 [db] and 25 [db] are required. 2.2. Description of the entire unit Double flow ventilation can be handled through Decentralized Air Handling Terminals (DAHT) integrated in walls or window ledges and provided with heat recovery exchangers. Figure 2 shows a perspective and section of the studied system [2]. Flow configurations inside the unit are also represented in Figure 2. Figure 2 : Investigated Decentralized Air Handling Terminal (DAHT) and flow configurations inside the unit The proposed design differentiates from other ones, mainly by: - the high effectiveness counter-flow heat exchanger, - the adaptability of heat exchanger and fans to different window sizes and flow rates. The investigated DAHT consists in a parallelepiped box containing two (injection and extraction) fans, two filters, an electronic control, and obviously, a heat recovery exchanger. 2

2.3. Heat recovery exchanger The heat recovery exchanger is the most important component of the device. The developed heat recovery exchanger is made in synthetic material with a high enlargement factor, and hence, a high compactness (456[m 2 /m 3 ]). This type of heat exchanger shows a quasi counter-flow configuration since, except the supply and exhaust zones, the central and major part of the device is in counter-flow configuration. Figure 3 : Flow configurations in the heat exchanger 2.4. Fan One of the goals of the device is to well-balance the extracted and pulsing flow rates. The device is supposed to be symmetrical for both sides and hence, to have the same aeraulic performance curve. From these facts, identical extracting and pulsing centrifugal fans were selected. 3. Experimental investigations The present section describes the experimental investigations carried out to determine the thermal and aeraulic performance of some components of the system. 3.1. Thermal performance: investigation on the heat recovery exchanger 3.1.1 Test bench. A schematic representation of the test bench dedicated to the heat recovery exchanger performance assessment and pictures of its practical achievement are given in Figure 4. Fresh air can be cooled down by means of the direct-expansion evaporator of an air-cooled chiller. In order to avoid freezing of the evaporator, the latter is supplied with fresh air delivered by an air compressor coupled to an industrial dryer. It is possible to control the fresh air temperature at the inlet of the heat exchanger by post-heating the fresh air flow rate with the use of variable electrical resistances. Ducts containing fresh air flow are insulated by mineral rock of 25 [mm] thickness. Vitiated air (ambient air) can be cooled down and/or dried by by-passing part of the flow rate exhausting from the evaporator in a mixing box situated at the inlet of the vitiated air fan. Here also, it is possible to control with precision the vitiated air temperature by means of variable electrical resistances. Humidity is controlled by the use of electrical steam generators supplied with variable electrical power. Figure 4 : Experimental set-up to test heat recovery exchangers 3

The mass flow rate of both fluids (fresh and vitiated air) can be adjusted by means of a set of regulating valves and are measured by means of orifice plates, as recommended in the ISO 5167 [3]. Differential pressure sensors dedicated to the flow rates measurement have an accuracy of +/- 2.5 Pa. Air temperatures are measured with type T thermocouples with accuracy of +/- 0.3 K. In the rest of the paper, the mean supply and exhaust temperatures correspond to the average of five measurements each by type T thermocouples, as mentioned in the NBN 308 [4]. The pressure difference between the inlet and the outlet of the heat exchanger is measured by means of two distinct differential pressure sensors: one dedicated to the lowest air flow rates with an accuracy of +/- 1 Pa with a full-scale value of 100 Pa and another one with an accuracy of +/- 2.5 Pa with a full-scale value of 500 Pa. The relative humidities (RH) at the inlet and at the outlet of the vitiated exhaust air stream are measured by means of humidity sensors with an accuracy of +/- 2 percent points. These sensors have been calibrated by means of LiCl and NaCl, which permits to create an atmosphere at respectively 11.3% and 70% of relative humidity. The heat exchanger is located in a box insulated by 30 [mm] thick polystyrene in order to reduce heat losses to the atmosphere. In order to ensure a uniform air flow rate through the heat exchanger, dampers with filters are placed in the box upstream the heat exchanger. All the measurements were automatically stored in a PC by means of several data acquisition cards. Two tests have been carried out on the heat exchanger: one focusing on the aeraulic and the other on the thermal performance of the device. 3.1.2 Aeraulic performance: testing conditions and experimental results.concerning the aeraulic performance, the pressure drop was determined for several air flow rates (ranging approximately from 30 to 100 [m 3 /h]). The conditions at the inlet of the heat exchanger for these tests were 22 [ C] and 40 [%] of relative humidity. Each presented result for the several air flow rates concerning the aeraulic performance of the heat exchanger corresponds to a stabilized time test of 200 [sec]. Two differential pressure sensors were used for the determination of the aeraulic performance: one with a full scale value of 100 [Pa] for the lowest air flow rates and one with a full scale value of 500 [Pa] for the highest air flow rates. 3.1.3 Thermal performance: testing conditions and experimental results. Investigated flow rates are comprised between 0 and 100 [m 3 /h]. Since the flow rates are rather small, the temperature difference between both inlets of the heat exchanger was chosen in a range comprised between 30 to 40 [K] (between 30 and 40 [ C] for the inlet vitiated air and between 0 and 10 [ C] for the inlet fresh air). Obviously, these conditions (especially the high virtual indoor temperature) do not correspond to the usual operating conditions of the device but allow minimizing the relative error on the heat transfer measurement. The results presented in the following part of the paper correspond to the average value of stabilized time regime of 500 [sec]. The stabilized time regime is longer than for the determination of the aeraulic performance of the device. This choice has been made to avoid any potential thermal derive of the system. The aim of these tests was to determine the performance of the heat exchanger in dry conditions. Part of the dry air coming from the dryer and exhausting from the chiller evaporator was deviated into the mixing box situated at the inlet of the vitiated air pulsing fan (see Figure 4). The operation in dry regime was checked by means of the measurements of the humidities at the inlet and at the outlet of the heat exchanger and was achieved during the whole set of tests. In order to be as close as possible to the nominal operating conditions, another condition concerning these tests was to well-balance both mass air flow rates. This condition was fulfilled by using regulating valves of the test bench. 4

Since experimental conditions have been chosen in order to avoid condensation in the exchanger, heat transfer rates Q in [W] were measured on both the vitiated and fresh air sides, respectively, by the two following equations: Q av = C av t su,av t ex,av (1) Q af = C af t ex,af t su,af (2) The difference between these two values is always lower than 3.2 %, and the mean relative difference is equal to 1.8%, which was considered as satisfying considering the small investigated flow rates. The first step to determine effectiveness from measurements consists in weight averaging the supply and exhaust temperature measurements provided by the several type T thermocouples for each flow rates. Two effectiveness s can be determined from measurements: the one measured at the fresh air side and the one measured at the vitiated air side. The presented effectiveness is the one permitting to avoid error measurements on the mass flow rates by comparing the two capacity flow rates, as explained hereafter: if C min = C av then ε meas = C av t su,av t ex,av C min t su,av t su,af = t su,av t ex,av t su,av t su,af = ε meas,av Else ε meas = C av t ex,af t su,af C min t su,av t su,af = t ex,af t su,af t su,av t su,af = ε meas,af End (3) (4) 3.1.4 Experimental results. The experimental results in terms of aeraulic performance for each side of the matrix (c1and c2) are given in Figure 5a. As observed, the discrepancies between aeraulic performances for each side of the matrix reveal a dissymmetry of the matrix. Figure 5 : Aeraulic (a) and thermal (b) performance of the heat exchanger (experimental results) If the air mass flow rate is converted into a volumetric flow rate in standard condition (25 [ C] and 101325 [Pa]), the evolution of measured effectiveness shown in Figure 5b is obtained. Horizontal error bars indicate the uncertainty on measurements of the flow rates and vertical error bars indicate the uncertainty on measurements on the effectiveness. 5

3.2. Aeraulic performance of the device The present section focuses on the experimental investigation carried out to characterize the aeraulic performance of the entire system. 3.2.1 Delivered flow rate by the device. It is rather difficult to determine the delivered flow rates by means of velocity sensors since the velocity at the exhaust of the device is quite small and not homogeneous. Moreover, use of intrusive sensors can modify the delivered flow rate. A method initially dedicated to fan-coil unit and described by Hannay and Lebrun [5] was applied. Figure 6 : Schematic representation of the experimental apparatus to determine the delivered flow rate by the device This method consists in connecting the exhaust slit of the device into a pressure-compensated box. As shown in Figure 6, at the exhaust of the compensating box, a set of orifice plates is used to determine the flow rate. In order to annihilate the decrease of the delivered flow rate due to the passage through the orifice plate (which induces an additional pressure loss), a balancing fan is used. A differential pressure sensor is placed between the atmosphere and the inside of the compensated box. Once the measured differential pressure is equal to zero, the device is supposed to operate in nominal conditions and the volumetric flow rate measured by means of the orifice plate is the one really delivered by the unit. The delivered flow rate was measured for each side of the unit (with and without filter) and for several rotational speed of the fan. 3.2.2 Determination of fan curve. The same experimental apparatus than the one used to determine the delivered flow rate has been used to determine fan curves (total pressure versus volume flow rate). Fan rotational speed can be modified by means of an electronic control integrated in the device. Since the fan manufacturer only indicates the fan curve for the nominal rotational speed, it has been decided to determine the curves for several other rotational speeds. The developed experimental apparatus is shown in Figure 7. For a given rotational speed, it is possible to modify the total differential pressure drop between the inlet and the outlet of the fan by means of the set of regulating valves and the rotational speed of the balancing fan. The mass flow rate delivered by the fan is measured by means of a set of orifice plates, according to ISO 5167 [2], at the exhaust of the pulsing box. Figure 7 : Determination of fan curve for several rotational speed The total pressure drop between the inlet and the outlet of the fan is given by the following equation: ΔP tot = ΔP stat + ΔP dyn [Pa] (5) 6

The differential static pressure drop is measured by means of differential pressure drop sensor and the dynamical pressure drop is deduced, knowing the measured volumetric flow rate (orifice plates) and the supply and exhaust flow areas of the fan. 3.2.3 Determination of total pressure drop for a given rotational speed. The method presented in section 3.2.1 allows for determining the volumetric flow rates for a given rotational speed of the fan. In order to determine the aeraulic characteristic curve of the unit (flow rate total pressure drop), the total pressure drop at the outlet and the inlet of the fan was determined in the same manner than the one already explained in section 3.2.2 Once again, total pressure drop was determined for a device with and without filter. 3.2.4 Reconciliation of experimental results. The three previous tests can be used to represent the total aeraulic performance of the device, as represented in Figure 8. The rotational speed of the fan was measured by a tachymeter. Figure 8 : Aeraulic performance of the device Figure 8 permits to quantify the influence of the filter on the delivered flow rate. 4. Further work Further work will consist in testing the entire system in a climatic chamber. In reality, both (fresh and vitiated) volumetric air flow rates are pulsed through slits of the same length of the heat recovery device. Figure 9: Schematic representation of the experimental apparatus dedicated to the thermal performance of the entire unit 7

From this fact, it is very difficult to determine a fresh and vitiated mean temperature at the exhaust of the exchanger. Moreover, in order to take into account the conduction effects in the unit and an eventual degradation of thermal performance due to a mis-distribution of the flow rate through the heat exchanger, the best way to determine the thermal performance of the entire device is to test it into a climatic chamber by merging all tests presenting here above, in this paper. The idea is to place the unit in a wall separating an outdoor and an indoor room of a climatic chamber. Flow rate delivered by each side of the unit are measured by the same method than the one exposed in section 3.2.3. The mean outlet temperature of each side of the device is determined by means of five thermocouples T (placed as mentioned by NBN 308 [3]) situated at the exhaust of the pressure-compensated box. The main advantage of the present exposed method is that the test bench allows for testing in several operating conditions, which includes freezing ones. From this fact, electronic control dedicated to avoid freezing in the unit (by mis-balancing the fresh and vitiated flow rate, as an example) could also be tested. COP of the system could also be determined by measuring the supply electrical power delivered to the unit. 5. Conclusion The present paper offers a description of the experimental investigations that can be carried out to determine the thermal and aeraulic performance of a decentralized air handling terminal (DAHT). Compared to a centralized one, even if its thermal effectiveness is lower (mainly due to the small dedicated volume), this system presents a set of advantages. From the fact that its installation avoids pulsing and extracting ducts through the house, it is appropriate for heat recovery ventilation of retrofitted houses. Avoiding ducts also means shortening the aeraulic circuit, and hence the pressure drop related to the passage of air flow rates through these. It induces an improvement in terms of environmental hygiene (by avoiding a potential dust accumulation in ducts). Accessibility of each component and hence the maintenance of the system (particularly, the filters replacement) is easier. The first part of the paper focuses on the experimental investigation that can be carried out in dry regime on the heat recovery exchanger (one of the components of the DAHT). Experimental investigations dedicated to thermal and aeraulic performance of the components are presented. The second part of the paper focuses on the aeraulic performance of the unit. Finally, a method dedicated to determine the thermal performance of the entire DAHT in several operating conditions is presented. 6. References [1] NBN S01-400-1. Norme nationale belge. Critères de l isolation acoustique pour les immeubles d habitation. Janvier 2008. [2] Masy, G., Lebrun, J., Prieels, L., Vincent, B. and Hansen, N. 2011. A model of Decentralized Air Handling Terminals interacting with Building Infiltration, Roomvent, 2011. [3] ISO 5167. Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full. ISO Standard. First edition (1980) [4] NBN EN 308. Norme nationale belge. Echangeurs thermiques Procédures d essai pour la détermination de la performance des récupérateurs de chaleur air/air et air/gaz. Mars 1997 [5] Hannay, J., Lebrun, J., (1972). Méthode d essais applicable aux ventilos convecteurs, Thermique et aéraulique, Juin 1972. 8