EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

Similar documents
EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

MFD Mechanical Fireplace Damper

ENERVEX ADC100 DRAFT CONTROL

EBC 12 Modulating Fan Control

EW 40 Wireless Fan Control

ADC150 Automatic Draft Control

MEC 18 Mechanical Exhaust Control

ENERVEX MFD MECHANICAL FIREPLACE DAMPER

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

RS Chimney Fan for Gas & Oil Applications

RS Chimney Fan for Gas & Oil Applications

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

ENERVEX MDF MODULATING DAMPER

ENERVEX RSV CHIMNEY FAN

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

ENERVEX GSV GREASE FAN

ENERVEX IPVB INLINE POWER VENTER

RS chimney fan for gas and oil applications

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RSIB Power Venter

ENERVEX GSV GREASE FAN

IPVB EC inline power venter

GSV 9-16 Grease Fan for Solid Fuel Applications. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

GSV Grease Fan

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Humidity and Thermostat control box for Attic Fan

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

Integrated Ventilation System

Overload LED On & Power LED On

Installation Instructions Remote Blowers

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

PLEASE READ AND SAVE THESE INSTRUCTIONS

Operating Instructions and User s Information Manual for use by engineers and heating contractors VITOTRONIC 100 IMPORTANT

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

Operating instructions

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /1/10

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

External Roof-mounted Power Vent System

UNDER CABINET RANGE HOOD

,4X IMPORTANT SAFETY INSTRUCTIONS

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions

Model 600 Operation & Maintenance Manual

USER S INFORMATION MANUAL

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

USER S INFORMATION MANUAL

CHAPTER 8 CHIMNEYS AND VENTS

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Fig. 1 - Unit PGD4, PGS4, WPG4

Operating Instructions

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

WARNING FIRE OR EXPLOSION HAZARD.

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Installation Requirements for Models:

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

ELECTRONIC FIREPLACE DAMPER

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Bathroom Exhaust Fan/Fluorescent Light Combination


User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

Use, Care, and Installation Guide

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

T4398A,B Precision Electric Heating Thermostat

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor

USER'S MANUAL PGE Single Package Rooftop

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Owner s Information Manual

Transcription:

Installation & Operating Manual EFC 211 Fan Control USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter 5 Maintenance and Troubleshooting... Chapter 6 C INTERTEK LISTED CM Volko Supply - Enervex Fan Source www.enervexfansource.com 800 685 8263 US Job Name: Installer: Installation Date: ENERVEX Inc. 1685 Bluegrass Lakes Pkwy. Alpharetta, GA 30004 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@chimneyfans.com www.chimneyfans.com

1. Product Information 2. Specifications 3. Mechanical Installation 4. Electrical Installation 1.1 Product Information...3 1.2 Shipping...3 1.3 Warranty...3 3.1 Dimensions & Capacities...5 4.1 Location...6 5.1 Terminal Connections...7 5. Startup and Configuration 6.1 Pre-Operation Inspection...8 6.2 Setting the Control...8 6.3 Surveillance...8 6.4 Alarm Functions...8 Symbol Legend: The following terms are used throughout this manual to bring attention to the presence of potential hazards or to important information concerning the product. Danger: Indicates an imminently hazardous situation which, if not avoided, will result in death, serious injury or substantial property damage. Caution: Indicates an imminently hazardous situation which, if not avoided, may result in personal injury or property damage. TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed on the front of the manual. 2. Before servicing or cleaning the unit, switch off at service panel and lock service panel to prevent power from being switched on accidentally. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with applicable codes and standards. 4. Follow the appliance manufacturer s guidelines and safety standards such as those published by the National Fire Protection Associations (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. This unit must be grounded. How to use this manual This installation manual does not contain any system design documentation. System design documentation is available from any authorized EXHAUSTO representative. Accessories, fans and variable frequency drives are not covered by this manual. Please refer to these component s individual manuals. 2

1. Product Information 1.1 Function Use The EXHAUSTO EFC211 Fan Control is used with wood-fired heating appliances to monitor and maintain proper draft. This is achieved by maintaining the proper speed of a chimney fan. The EFC 211 is designed for use with EXHAUSTO Models RS, RSHT or GSV. The intended use of the control includes, but is not limited to: Controlling the speed of a chimney fan used with a wood-fired fireplace or stove Controlling the speed of a chimney fan used with a wood-fired pizza oven in a restaurant kitchen For indoor installation only. Function The EFC211 consists of a control box and a speed control unit. The control box is installed on the outside of the chimney or inside an attic. The speed control unit is installed in the room where the heating appliance is located. The fan control should be set to produce the desired fan speed or draft. The chimney fan starts with a 15 second boost to assure proper fan operation. At the same time, the green LED on the control panel will flash. After the 15 seconds, the chimney fan will continue to operate at the set speed. During operation the fan speed can be adjusted using the dial, which is also used to turn the fan on and off. The control measures the current draw of the motor every minute to determine if there is adequate draft in the chimney. If there is not, the control will send a signal to briefly increase the fan speed. If the draft remains inadequate, the fan speed will increase to maximum speed for 15 seconds. During this time the green LED will flash - as it does during start up. If the draft is adequate the chimney fan will continue to operate at the set speed. A green LED flashing during normal operation (after start up) is an indication that the minimum current in the power supply is set too low for the fan to operate. The factory setting for the motor power supply is 65 VAC. If the red LED flashes and the buzzer sounds, it can be caused by: Blocked Flue Defective chimney fan Disconnected power supply The control can be reset, and the alarm turned off, by pressing the reset button for 1-2 seconds. When used with a solid-fuel fired appliance a smoke detector shall be installed and maintained in accordance with NFPA72, National Fire Alarm Code. Listings Listed to UL378, Standard for Draft Equipment, when used with an EXHAUSTO Chimney Fan, Model RSHT 009-016. Approved for and meets the requirements of NFPA 211 Standard for Solid-Fuel Chimneys and Fireplaces. Intertek ETL Semko is not endorsing the connection of this controller to any draft fan, exhaust fan that is not of the models mentioned above. This controller model: EFC 211 is only recognized for connection to the above models that are manufactured by Exhausto Inc. as mentioned in the above paragraph and bearing the ETL mark for Canada and the USA. Use with a fan installed in a Solid Fuel Burning Appliance has not been proven to meet safety compliance. 1.2 Shipping The EFC 211 contains the following: Control box Speed Control Unit User manual 1.3 Warranty Complete warranty conditions are available from EXHAUSTO, Inc. 3

EFC 211 Control Components The EFC 211 control is built up around a main control units that controls all basic functions. The main control units controls the draft or exhaust function. It is connected directly to the power supply and feeds power to the chimney fan. The main control unit is shown below in Fig. 1: Front Back Terminals Fuse Terminals Fig. 1 The front panel serves as a cover for a 4x4 junction, while the control unit is mounted on the back of the cover. The board contains the wiring terminals as well as the triac used to control the speed of the chimney fan. The board is protected by a fuse. The speed control unit is connected to the main control unit. The speed control unit is shown below in Fig. 2: Front Back On/Off indicator Warning light Terminals Dial Battery Reset button Fig. 2 The speed control unit is used to turn the chimney fan on and off, set the fan speed and monitor the operation. It has indicator lights to confirm operation and to warn in case of malfunctions. The control has an audible alarm that sounds in case of power failure or other failure involving the chimney fan. The control unit has a rechargeable battery back-up used to operate the control s safety functions. 4

2. Specifications 2.1 Dimensions & Capacities Specifications Main Control Unit Speed Control Unit EFC 211 Main Control Unit Power supply V 1x120VAC Amperage A 5.8 Operating temperature F/ C -4 to 122/-20 to 50 Dimensions A in/mm 4.56/116 B in/mm 4.56/116 C in/mm 1.00/25 Weight lbs/kg 1.3/0.6 EFC 211 Speed Control Unit Power supply V 1x120VAC Amperage A 5.8 Operating temperature F/ C -4 to 122/-20 to 50 Output VAC 10-120 Dimensions D in/mm 2.73/69 E in/mm 4.44/113 F in/mm 0.50/13 G in/mm 1.00/25 Weight lbs/kg 1.3/0.6 A B D E C F G 5

3. Mechanical Installation 3.1 Location The main control unit can be installed indoors as well as outdoors. It fits a standard 4x4 weatherproof junction box, like the one that is supplied with the chimney fan. An extension ring must be used as shown on fig. 3: Fig. 3 Show the control taken apart on the side of the chimney Show the control mounted on side of chimney The speed control unit can only be installed indoors. It fits a standard 2x4 wall box. See fig. 4 Fig. 4 Show the control taken apart outside the wall box Show the control mounted on a wall 6

4. Electrical Installation 4.1 Terminal Connections Danger: Turn off electrical power before servicing. Contact with live electric components can cause shock or death. EFC 211 is designed for 1x120VAC power supply only. The terminals are connected as shown on Fig. 9: Fig. 9 7

5. Startup and Configuration 5.1 Pre-Operation Inspection After mounting and wiring has been completed, check the control for the following items before applying power: Check for wiring errors. Verify that there are no wiring chips, screws, etc. remaining inside the junction boxes. Check that all screws and terminal connections are tight. Verify that no exposed wire ends are touching other terminals. Apply power to the control. Let the control be turned on for 12 hours to allow the battery to be charged. Warning: Make sure the battery is fully charged before using the solid-fuel appliance. Failure to charge the battery will prevent the control from provide safe operation. 5.2 Setting the Control Turn the control on by turning the knob clockwise. A click is heard when know is turned which indicates the control is turned on. Adjust the knob to the desired speed. The speed must be set so no smoke escapes the solid fuel heating appliances (fireplace, stove, wood-fired oven etc.) through the opening into a room. The smoke should safely be exhausted through the chimney. The chimney fan will start with a 15 seconds boost to assure proper fan operation. The green LED on the speed control unit cover will flash After the 15 seconds the chimney fan will continue to operate at the desired speed. During appliance operation the speed setting can be adjusted. 5.3 Surveillance The control constantly monitors the chimney fan operation. It automatically measures the fan speed every minute and if necessary, it will increase the speed which can be heard as quiet hick-up from the fan. If necessary, the control will increase the speed to full speed for 15 seconds (green LED flashes), after which, if possible, it will slow the fan speed down to the desired speed. 5.4 Alarm Functions If the green LED flashes during operation (after the 15 seconds initiation) the fan speed is set too low or the fan wheel is somehow obstructed. If the red LED flashes and the buzzer sounds, it can be caused by: Defective chimney fan Disconnected power supply The control can be reset, and the alarm turned off, by pressing the RESET button for 1-2 seconds. Volko Supply - Enervex Fan Source www.enervexfansource.com 800 685 8263 ENERVEX Inc. 1685 Bluegrass lakes Pkwy. Alpharetta, GA 30004 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@chimneyfans.com www.chimneyfans.com