Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

Similar documents
Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Vertical Inline Models

INSTRUCTION AND REPAIR MANUAL

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

569, 570, 571, 572 Series

569, 570, 571, 572 Series

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

IN-TANK TECHNOLOGY REPAIR GUIDANCE: MOTOR REPLACEMENT FOR BX3000 & BX5000

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

568X, 587X, 588X Series

Mechanical seals external, single or double, to DIN EN 12756

Audi-Larm Audible Alarm

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Operations Challenge Maintenance Event

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

Ceiling Fan Blade Arm Replacement

Platen Heater Pad Replacement

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

STAINLESS STEEL UNITS

Operation, Maintenance and Installation Manual

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

Rhino AB Upper Check Valve Replacement

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

Installation Instructions

Altra Series Dampener

Mechanical Seal RG-4 stationary, double, liquid sealed

CR A-F-A-E-HQQE 3x400/ HZ

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

Installation and operating instructions. E.2 Series high efficiency circulator

E.2 series high efficiency circulator. Installation and operating instructions

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

D1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

AC6/6H & AC8/8H Horizontal Metric Models

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

Heat Exchanger Block Replacement Instructions

MG200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential and Pressure Sewer Applications.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

SuperKlean Washdown Products

Service Documentation Market Release 7/84. Braun Kitchen machine KM 32 B 4209 with lamp

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

HEATING AND VENTILATION

MODEL 4246 MIXER-GRINDER

SMF PUMP OWNER S MANUAL

Carbon Rack Enclosure

CBT Bowl & wrap replacement

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

INSTALLATION & OPERATING INSTRUCTIONS

Fly / Rear Deltoid. Owners Manual

TEXAS WATER 2013 WALTER CHIANG

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Two Tier Illumifalls Patio Pond

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

Motor/Frame Assembly. Drain Cleaning Machine K Position Fan as Shown. Fan Mounting Detail

Services Unlimited Inc./Parts Guru. Beverage Dispensers. Mini, Standard, Heated, Whipper and Super Bowl Models. Service Manual

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Drain Cleaning Machine K-39

Installation and Care Instructions

Dyna-Star HP, HF, 10:1 Pumps: 120# and 400# Drum Cover and Follower Plate

Vertical Multistage. HP Phase Voltage Amps

Hustler Z Bac Vac Parts Manual ,

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Water Distiller Service Manual

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Used with: Pre NT, 3P605NT Pre , 1006 Native Grass Pre PNG12, 3PNG15, 2SNG24, 2SNG30, NG12 Grass Seeder

E, F & G SERIES CENTRIFUGALS INSTALLATION INSTRUCTIONS

BMW E36 Thermostat Removal And Coolant Flush

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

TECHNICAL INSTRUCTIONS

KITCHEN FAUCET COS-KF222C

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

Transcription:

GRUNDFOS CR Series Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 5 Grundfos Pumps Corporation 17100 W. 118th Terrace Olathe, Kansas 66062 Telephone: 91.227.00 Fax: 91.227.500 www.grundfos.com LCR-STK-15 02/0 PRINTED IN USA

These instructions cover the replacement of stack after the pump has been isolated from the system. Before removing the pump from the system, make sure all valves are closed. Relieve any built up pressure by opening the vent plug screw. The power source should be turned off and locked out before starting any work. Removal of field wiring to the motor wires may be required. Color coding or numbering the wires will aid in reinstallation. 1 2 Using a screwdriver, remove Coupling Guard Screws (Pos. 7a). Then, remove the Coupling Guards (Pos. 7). Remove the Hex Head Coupling Bolts (Pos. 9) from the Coupling Halves (Pos. 10a). Now remove Coupling Halves and the Shaft Pin (Pos. 10). Remove the cartridge Shaft Seal (Pos. 105) by: Loosening the three 2.5 mm Shaft Seal Securing Allen Screws (Pos. 11). Do not fully remove screws as this may cause the seal assembly to come apart in component form. Remove the Motor Bolts (Pos. 28) and lift the motor off the Motor Stool (Pos. 2). Using 00SV2007 or a 6 mm deep socket, fully unscrew the Shaft Seal from the Motor Stool (Pos. 2) or Pump Head (Pos. 77) on I and N models. Slide the Shaft Seal up and off the Shaft (Pos. 51). 5 6 Remove the Motor Stool (Pos. 2) and Pump Head (Pos. 77) on I and N models. (Light upward blows with a rubber mallet may be required.) Remove the four 19 mm Staybolt Nuts (Pos. 6) and Washers (Pos. 66a). 2

7 8 Lift out the Stack. If the unit had leaked around the Sleeve (Pos. 55), removal of the Sleeve may be required. Grip Staybolts (Pos. 26) diagonally. Then, using your thumbs, press against the Sleeve to release it from the Pump Housing (Pos. 6). Lift off sleeve. (Light upward blows with a rubber mallet may be required.) 9 THE PUMP IS NOW COMPLETELY DISASSEMBLED. Remove, check, and replace damaged Sleeve O-rings (Pos. 7) in the Motor Stool (Pos. 2) or Pump Head (Pos. 77) and the Pump Housing (Pos. 6).

Reassembly Dismantling Procedures CR(I/N) 1S/1//5 1 2 Spray soapy water on the Sleeve O-rings (Pos. 7). Then lower and press Sleeve (Pos. 55) firmly into place. Lower new Stack Kit into the Pump Housing. Make sure it seats fully into the machined recess. Spray soapy water on the Sleeve O-rings (Pos. 7) in the Motor Stool or CR(I/N) Pump Head. Then lower and fully press in place. For I/N models, place the Motor Stool Bracket (Pos. 2) over the Pump Head and press against this to seat the Pump Head. Place the Washers (Pos. 66a) over the Staybolts (Pos. 26). Then, lubricate with a light oil. Place the 19 mm Staybolt Nuts (Pos. 6) onto Staybolts and tighten diagonally to CR/CRI: 29.5 ft.-lbs. or 0 Nm CRN: 7 ft.-lbs. or 50.2 Nm 5 6 Lower the new Shaft Seal (Pos. 105) over the Shaft, then tighten to 26 ft.-lbs. or 5 Nm. Do not tighten the three 2.5 mm Spray soapy water onto the Seal O-ring Seating Surface of the Pump Head and the Shaft (Pos. 51). Shaft Seal Securing Allen Screws (Pos. 11) at this time; this will be done after step 12.

Dismantling Reassembly Procedures CR(I/N) 1S/1//5 7 8 Lower motor onto Motor Stool, then install and tighten Motor Bolts (Pos. 28) diagonally to the proper torque. Place the Shaft Pin (Pos. 10) into the Shaft (Pos. 51). 10 ft.-lbs. or 1.55 Nm for UNC /8" bolts, and 2 ft.-lbs. or 1 Nm for UNC 1/2 bolts 9 10 11 CORRECT Top View Gap between coupling iew ling Keyway Keyway Install Coupling Halves (Pos. 10a). Spray a light machinery oil onto the Coupling Bolts (Pos. 9). Install loosely into the Couplings. Using a screwdriver, lift the Shaft to its full travel upward, then lower half the distance and tighten and torque the Coupling Bolts. M6 to 10 ft.-lbs. or 1 Nm M8 to 2 ft.-lbs. or 1 Nm M10 to 6 ft.-lbs. or 62 Nm Ensure the gap between the two Coupling Halves are even. See Installation Operation Manual. CORRECT NOT CORRECT 12 Spin the shaft by hand; proceed only if the shaft spins freely. If the shaft does not spin freely: Stop and start over, inspecting the components for any cause of binding. 1 1 Install the Coupling Guards (Pos. 7) and the Screws (Pos. 7a). Torque to 2 ft.-lbs. or 2.5 Nm. THE PUMP IS NOW COMPLETELY ASSEMBLED. Open the isolation valves in the system to fully vent and fill the pump. Restore power supply. Tighten the three Shaft Seal Securing screws (Pos. 11) to the Shaft. Finish torque of 2 ft.-lbs. or 2.5 Nm. 5