MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

Similar documents
ADF/ADFH 300 and 500

LARGE CAPACITY HEATERS

FEATURES AND BENEFITS

Gas-Fired Indoor and Outdoor Duct Furnaces

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Fired Heater Model AD Specification

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Direct Gas-Fired Make-Up Air

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Direct Fired Units w/ Packaged Cooling

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Gas-Fired Indoor and Outdoor Duct Furnaces

Indirect Gas-Fired Make-Up Air

Equipment Specifications

8+* Bulletin No November 1997

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

STR-Series Indirect-Fired Air Turnover Units

MERIT SERIES Downflow

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

! WARNING: FIRE OR EXPLOSION HAZARD

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

48TF GAS HEATING/ ELECTRIC COOLING UNITS

! WARNING: FIRE OR EXPLOSION HAZARD. Installation / Operation. Applies to: Air Handler Model PDH, Model SDH, Model PEH, Model PXH, and Model SHH

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

HVAC HEATING PRODUCTS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Infrared Heating Catalog

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

G34M Bulletin #69/ August 2003

FOR YOUR SAFETY FOR YOUR SAFETY WARNING:

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

CONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,

FOR YOUR SAFETY WARNING FOR YOUR SAFETY IMPORTANT CAUTION

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

Power Flame Incorporated

Modular Heating & Ventilating Unit Model IGX-HV

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

SAFETY CONTROL REQUIREMENTS FOR OVENS AND FURNACES

Power Flame Incorporated

DIVISION FINNED WATER-TUBE WATER HEATERS

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

RGE 13 A T - 1 A

CSD-1 COMMERCIAL BOILER CONTROLS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

ELITE SERIES Downflow - High Efficiency Blower Motor

BANANZA. B-Series Direct-Fired Heating, Cooling And Pressurization Systems. Equipment Specifications

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Owner s Information Manual

INFRARED RADIANT TUBE HEATER

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48TM GAS HEATING/ELECTRIC COOLING UNITS

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

DIVISION FINNED WATER-TUBE BOILERS

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE

LGB Gas fired boiler

Fig. 1 - Unit PGD4, PGS4, WPG4

INFRARED RADIANT TUBE HEATER

Indirect gas-fired air heater

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

INFRARED RADIANT HEATERS

VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES INDOOR GRAVITY VENTED UNIT HEATERS AND PACKAGED SYSTEMS

Direct Gas-Fired Make-Up Air Models DG and DGX

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

SERIES 19A. mith PRESSURIZED WET BASE

A. Product Data: Include rated capacities, furnished specialties and accessories.

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

OWNER S MANUAL PG9YAA HIGH EFFICIENCY GAS FURNACE ! WARNING SAFETY CONSIDERATIONS

THE CORPORATION OF THE CITY OF LONDON. POTTERSBURG POLLUTION CONTROL PLANT FILTER BUILDING ODOUR CONTROL Tender No ADDENDUM NO.

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Transcription:

MODEL ADF/ADFH 300 and 500 FOR INDUSTRIAL & COMMERCIAL APPLICATIONS Model ADF CSA 3.7 ANSI Z83.4 Non-Recirculating Industrial Air Heaters WARNING: GAS-FIRED APPLIANCES ARE NOT DESIGNED FOR USE IN HAZARDOUS ATMOSPHERES CONTAINING FLAMMABLE VAPORS OR COMBUSTIBLE DUST, OR AT- MOSPHERES CONTAINING CHLORINATED OR HALOGENATED HYDROCARBONS. IN- STALLATIONS IN PUBLIC GARAGES OR AIR- PLANE HANGARS ARE PERMITTED WHEN IN ACCORDANCE WITH ANSI Z223.1 AND NFPA 54 CODES OR CAN1 - B149 CODES AND ENFORCING AUTHORITIES. NOTES: (1) Model ADF/ADFH systems are not approved for residential use. (2) To retain certification, outdoor installations must include an optional screened inlet air hood or an optional evaporative cooling module. DESCRIPTION STANDARD FEATURES The Reznor ADF/ADFH Series units are direct-fired heating/makeup air systems designed for either indoor or outdoor installation. Model ADF/ADFH 300 and Model ADF/ADFH 500 systems are available to operate on either natural or propane gas. Maximum heating capacity is 750,000 BTUH. Maximum air handling capacity is 7300 CFM. The ADF Models provide discharge air at a maximum temperature of 120 F; ADFH Models are designed for applications requiring discharge air at a maximum temperature of 160 F. Standard electrical controls include a unit-mounted electronic circuit board with diagnostic lights, a motor contactor, and an intermittent hot surface ignition system. Standard gas controls include a single-stage valve controlled by a unit-mounted discharge air controller, main and pilot pressure regulators, a pilot solenoid valve, and main and pilot manual shutoff valves. Safety controls include a flame supervisor with 100% lockout, a low air flow proving switch, a pre-purge time delay, an energy cutoff device, and both automatic and manual temperature limit controls. The weatherized, insulated cabinet is mounted on a full curb cap base. The base is designed for mounting on a roof curb or on rails. Model ADF/ADFH units are approved for use in the United States to the latest editions of ANSI Standard Z83.4; and Canada to CAN 3.7 for non-recirculating gas-fired industrial air heaters. Weatherized, insulated, single-wall cabinet Horizontal configuration on a full curb cap base Horizontal inlet for 100% outside air Horizontal discharge - ADF Models Vertical (down) discharge - ADFH Models Cast iron direct-fired burner with stainless steel mixing plates Observation port for viewing pilot Natural gas fuel Manifold arrangement to 400 MBH 115/1/60 supply voltage 1/2 HP Open dripproof motor with contactor Adjustable belt drive Single-stage gas valve with air controller Main and pilot gas pressure regulators Pilot solenoid valve Manual gas shutoff valves Unit-mounted electronic circuit board with diagnostic lights Flame sensor with 100% lockout Hot surface intermittent ignition system with pre-purge time delay (U.S. Patent No. 5,556,272) 24 volt transformer (fused secondary) Automatic and manual limit controls Low & high air proving switch Burner and blower service switches Emergency cutoff limit control Page 12 Form C-RDF (Version G) * When two-speed motor is used on high speed, the burner is locked out.

OPTIONAL FEATURES - Factory Installed: OPTIONAL FEATURES - Field Installed: DIMENSIONS MODEL ADF/ADFH 300 and 500 Vertical (down) discharge - ADF Models 208/1, 230/1, 208/3, 230/3, 460/3, or 575/3 supply voltage 3/4-10 HP Open dripproof motors; 1/2-10 HP Totally enclosed motors, 1-10 HP Premium efficiency motors, or 1-10 HP Two-speed motors for heating/cooling* (see RPM/BHP Tables) Two-stage gas valve with unit-mounted ductstat, seven types of electronic modulation gas controls Manifold arrangements that are certified to ANSI, CSA, FM and GAP1 requirements Double-wall construction Evaporative cooling module (see Evaporative Cooling Catalog) Discharge dampers Freezestat Firestat High ambient burner cutout control Interlocking relays Gas pressure switches Starters for auxiliary motors Roof curb Outside screened air inlet hood Outside screened air inlet hood with integral 1 or 2 disposable, disposable pleated, or permanent aluminum filters Indoor filter cabinet with 1 or 2 disposable, disposable pleated, or permanent aluminum filters Gas inlet pressure regulator (for applications where gas supply pressure exceeds 14 or 1/2 psig; regulator must be mounted external to the cabinet) Control console Disconnect switch Door switch (for door heater application requirements; order Option BX1) Discharge Horizontal Vertical * Models ADF300 ADF500 ADF300 ADF500 ADFH300 ADFH500 in. mm in. mm in. mm in. mm in. mm in. mm A 34 864 47 3/4 1,213 34 864 47 3/4 1,213 34 864 47 3/4 1,213 B 31 787 44 3/4 1,137 31 787 47 3/4 1,213 31 787 44 3/4 1,137 C 85 3/4 2,178 85 3/4 2,178 85 3/4 2,178 85 3/4 2,178 109 1/2 2,781 109 1/2 2,781 D 11 7/8 302 12 3/4 324 - - - - - - - - E 15 1/4 387 17 3/4 451 - - - - - - - - F (inside) 15 1/4 387 14 3/4 375 16 406 14 3/4 375 16 406 14 3/4 375 G 17 1/2 445 16 3/8 416 - - - - - - - - H (inside) 13 3/4 349 16 1/8 410 - - - - - - - - J - - - - 64 5/8 1,641 62 3/8 1,584 64 5/8 1,641 62 3/8 1,584 K - - - - 13 3/4 349 16 406 13 3/4 349 16 406 M - - - - 7 178 8 1/8 206 7 178 8 1/8 206 N - - - - 8 1/8 206 21 3/4 552 8 1/8 206 21 3/4 552 P - - - - 7 3/8 187 7 3/8 187 31 1/8 791 31 1/8 791 * Models ADFH 300/500 have a motor compartment required for high temperature discharge. Models ADF 300/500 with optional vertical discharge have same cabinet length as the standard ADF 300/500 with horizontal discharge. Form C-RDF (Version G) Page 13

MODEL ADF/ADFH 300 and 500 DIMENSIONS (cont d) FILTER RACK LOCATION NOTE: 1. On outdoor installations, filter rack is part of outside air hood. 2. On indoor installations, filter rack is a separate cabinet (see page 40). VERTICAL DISCHARGE NOTE: The motor compartment applies only to Models ADFH 300/500. Models ADF 300/500 with optional vertical discharge do not have the additional cabinet. Page 14 Form C-RDF (Version G) Model Inlet Air Opening (Horizontal) Dimension in. mm ADF/ADFH 300 19 1/2 x 22 7/8 495 x 581 ADF/ADFH 500 19 1/2 x 36 5/8 495 x 930 DISCHARGE DUCT OPENINGS (with and without discharge dampers) Model Discharge Dimension ADF 300/500 Horizontal G x E ADF 300/500 Vertical F x K ADFH 300/500 Vertical F x K NOTE: Motor for optional dampers with horizontal discharge is externally mounted on the control side of the damper frame. Horizontal damper frame extends 6 5/8 beyond heater duct connection.

MODEL ADF/ADFH 700 and 1200 FOR INDUSTRIAL & COMMERCIAL APPLICATIONS CSA 3.7 WARNING: GAS-FIRED APPLIANCES ARE NOT DESIGNED FOR USE IN HAZARDOUS ATMO- SPHERES CONTAINING FLAMMABLE VAPORS OR COMBUSTIBLE DUST, OR ATMOSPHERES CONTAINING CHLORINATED OR HALOGE- NATED HYDROCARBONS. INSTALLATIONS IN PUBLIC GARAGES OR AIRPLANE HANGARS ARE PERMITTED WHEN IN ACCORDANCE WITH ANSI Z223.1 AND NFPA 54 CODES OR CAN1- B149 CODES AND ENFORCING AU- THORITIES. Model ADF ANSI Z83.4 Non-Recirculating Industrial Air Heaters NOTES: (1) Model ADF/ADFH systems are not approved for residential use. (2) To retain certification, outdoor installations must include an optional screened inlet air hood or an optional evaporative cooling module. DESCRIPTION STANDARD FEATURES The Reznor ADF/ADFH Series units are direct-fired heating/makeup air systems designed for either indoor or outdoor installation. Model ADF/ADFH 700 and Model ADF/ADFH 1200 systems are available to operate on either natural or propane gas. Maximum heating capacity is 1,250,000 BTUH. Maximum air handling capacity is 15500 CFM. The ADF Models provide discharge air at a maximum temperature of 120 F; ADFH Models are designed for application requiring discharge air at a maximum temperature of 160 F. Standard electrical controls include a unit-mounted electronic circuit board with diagnostic lights, a motor contactor, and an intermittent hot surface ignition system. Standard gas controls include a single-stage valve controlled by a unit-mounted discharge air controller, main and pilot pressure regulators, a pilot solenoid valve, and main and pilot manual shutoff valves. Safety controls include a flame supervisor with 100% lockout, a low air flow proving switch, a pre-purge time delay, an energy cutoff device, and both automatic and manual temperature limit controls. The weatherized insulated cabinet is mounted on a full curb cap base. The base is designed for mounting on a roof curb or on rails. Model ADF/ADFH units are approved for use in The United States to the latest editions of ANSI Standard Z83.4; and Canada to CAN 3.7 for non-recirculating gas-fired industrial air heaters. Weatherized, insulated single-wall cabinet Horizontal configuration on a full curb cap base Horizontal inlet for 100% outside air Horizontal discharge - ADF Models Vertical (down) discharge - ADFH Models Cast iron direct-fired burner with stainless steel mixing plates Observation port for viewing pilot Natural gas fuel Manifold arrangement to 400 MBH 115/1/60 supply voltage 1 HP Open dripproof motor with contactor Adjustable belt drive Single-stage gas valve with air controller Main and pilot gas pressure regulators Pilot solenoid valve Manual gas shutoff valves Unit-mounted electronic circuit board with diagnostic lights Flame sensor with 100% lockout Hot surface intermittent ignition system with pre-purge time delay (U.S. Patent No. 5,556,272) 24 volt transformer (fused secondary) Automatic and manual limit controls Low & high air proving switch Burner and blower service switches Emergency cutoff limit control * When two-speed motor is used on high speed, the burner is locked out. Form C-RDF (Version G) Page 15

MODEL ADF/ADFH 700 and 1200 OPTIONAL FEATURES - Factory Installed OPTIONAL FEATURES - Field Installed Vertical (down) discharge - ADF Models (requires additional motor compartment) 208/1, 230/1, 208/3, 230/3, 460/3, or 575/3 supply voltage motors, 1-20 HP premium efficiency motors, or 1-10 HP Two-speed motors for heating/cooling* (see RPM/BHP Tables) Two-stage gas valve with unit mounted ductstat, seven types of electronic modulation gas controls Manifold arrangements to meet IRI and /or FM insurance requirements Double-wall construction Discharge dampers Freezestat Firestat High ambient burner cutout control Interlocking relays Gas pressure switches Starters for auxiliary motors Roof curb Outside screened air inlet hood Outside screened air inlet hood with integral 1 or 2 disposable, disposable pleated, or permanent aluminum filters Indoor filter cabinet with 1 or 2 disposable, disposable pleated, or permanent aluminum filters Evaporative cooling module (see Evaporative Cooling Catalog). Gas inlet pressure regulator (for applications where gas supply pressure exceeds 14 or 1/2 psig; regulator must be mounted external to the cabinet). Control console Disconnect switch Door switch (for door heater application requirements; order Option BX1). DIMENSIONS INLET AIR HOOD & HORIZONTAL AIR DISCHARGE DIMENSIONS For vertical air discharge dimensions and inlet/discharge air duct dimensions, see next page. Page 16 Form C-RDF (Version G)

DIMENSIONS (cont d) MODEL ADF/ADFH 700 and 1200 VERTICAL AIR DISCHARGE NOTE: Both Models ADFH 700/1200 and ADF 700/1200 with optional vertical discharge have a motor compartment cabinet. For inlet air hood and horizontal air discharge dimensions, see previous page. Inlet Air Opening Dimensions (Horizontal) Model in mm ADF/ADFH 700 19 1/2 x 47 5/8 495 x 1,210 ADF/ADFH 1200 19 1/2 x 47 5/8 495 x 1,210 DISCHARGE HORIZONTAL VERTICAL Models ADF ADF/ADFH 700/1200 700 1200 Size in mm in mm in mm A 92 1/8 2,340 117 2,972 117 2,972 B - - 72 1/8 1,832 69 7/8 1,775 C - - 13 3/4 349 16 406 DISCHARGE DUCT OPENINGS (with and without discharge dampers) Model Horizontal in mm ADF 700/1200 48 15/16 x 22 1/8 1,243 x 562 Models Vertical in mm ADF 700/1200 C x 40 5/16 C x 1,024 ADFH 700/1200 C x 40 5/16 C x 1,024 NOTE: Motor for optional dampers with horizontal discharge is externally mounted on the control side of the damper frame. Horizontal damper frame extends 6 5/8 beyond heater duct connection. FILTER RACK LOCATION NOTE: 1. On outdoor installations, filter rack is part of outside air hood. 2. On indoor installations, filter rack is a separate cabinet (see page 40). Form C-RDF (Version G) Page 17