Improving Quality and Productivity with Non-Contact Temperature

Similar documents
Innovative Technology for Traditional and Challenging Applications

ARE ALL SINGLE-WAVELENGTH INFRARED THERMOMETERS ALIKE?

PRO SERIES NONCONTACT TEMPERATURE SENSORS

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

optris TM Temperature Monitor for Infrared Sensors Operators manual

SS-100. Pyrometer. Temperature Range: 800~2400

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

Address: 2857 Sherwood Heights Dr. Unit 2, Oakville, ON, Canada. L6J 7J9 Toll free: LOGIKA

Infrared Temperature Sensor

INSTALLATION AND OPERATION MANUAL FOR THE PILOTEYE 2000

INSTALLATION AND OPERATION MANUAL FOR THE PYROSIGHT SERIES

Maxline 2 Thermal Imaging Solutions for Manufacturing

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

INSTALLATION AND OPERATION MANUAL FOR. The Flame Intensity Monitor

Williamson Pro Series Pyrometer

Raytek /Ircon Solutions Guide

Raytek /Ircon Solutions Guide. The Worldwide Leader in Noncontact Temperature Measurement

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

INSTALLATION AND OPERATION MANUAL FOR. The Flare Monitor

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

IRT2 Dual Laser IR Thermometer - User Guide

Heated tools. Semiconductor equipment

Dual Laser InfraRed (IR) Thermometer

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Dual Laser InfraRed (IR) Thermometer

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

RS Pro Infrared Temperature Sensor

R2310. Infrared Thermometer. Instruction Manual

An FT-NIR Primer. NR800-A-006

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

PUV, PIR and PFO Series BROCHURE

Temperature Sensors & Compression Seal Fittings

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Sitron s CF Line of Flow Switch Monitors

I/A Series 716C 1/16 DIN Temperature Controller

SUPERTHAL. Heating Modules for Customized Furnaces and Heaters

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Cabinet Cooler Systems

Heat Pipe Applications Introduce

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Ceramic Fiber Heaters

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Thermal Devices, Inc. Mount Airy, Maryland USA

Precision Infrared Thermometer. Users Manual

ADPRO PRO Series by Xtralis

Infrared Sensors for Industrial Automation. Raytek The Worldwide Leader in Noncontact Temperature Measurement

SENSORS AND SYSTEMS FOR THE STEEL INDUSTRY

UDC100 Universal Digital Controller Specifications

More Precision. thermometer // Non-contact IR temperature sensors

Strip/Clamp-On Heaters

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Using the DewTrak II Dew Point/ Humidity Transmitter

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

Using the Model 1500 Portable Chilled Mirror Hygrometer

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Open-area Smoke Imaging Detection (OSID)

Dräger Polytron Pulsar 2 Open Path Gas Detector

Model D12-IR. Digital Gas Transmitter...

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Advantages / Characteristics

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Flame 2500 Flame Detection

Danfoss gas detection units

A New Standard of Excellence

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

-REOTEMP s TC/RTD Background - Field Solutions - Product Overview -The REOTEMP difference

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SLAG DETECTION SYSTEM CONTINUOUS THERMAL MONITORING

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

PSA Series. Particle Size Analyzer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

THERMAL PROCESSING THEORY

High Temperature InfraRed Thermometer with Laser Pointer

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Infrared Sensors for Industrial Automation. Raytek The Worldwide Leader in Noncontact Temperature Measurement

OVEN INDUSTRIES, INC.

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Danfoss gas detection unit Type GD Heavy Duty

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Aspirated Smoke Detectors

2 General Application Photoelectric Sensors

Transcription:

Pro Series

Improving Quality and Productivity with Non-Contact Temperature INFRARED THERMOMETERS Temperature is commonly measured in manufacturing operations to monitor and control product quality and process productivity. For many applications, contact devices like thermocouples and RTDs are used, but for applications where these devices are inaccurate, too slow, or difficult to use, infrared thermometers are the perfect solution because they measure a target s temperature without contact. This capability is ideal for applications involving: High temperatures Moving targets Hostile or hazardous environments Fast response times With a complete range of infrared thermometers, Williamson can offer the optimal sensor for virtually any application. ADVANCED Dual and Multi-wavelength TEMPERATURE MEASUREMENT CAPABILITIES Williamson s Pro Series dual and multi-wavelength infrared thermometers feature state-of-the-art technology to provide accurate and reliable measurements for traditional and challenging applications including heavyindustrial environments. As the table below illustrates, these sensors feature many advanced measurement capabilities to outperform all others. Standard dual and multi-wavelength sensor features Temperature limits 200 to 4500 F / 95 to 2500 C Line of sight, visual aiming, laser aiming, and fiber optic aim light alignment options A selection of narrow band wavelengths for precise measurement on demanding applications A selection of wide angle and high resolution optics Each model can be used as a stand alone transmitter or connected to a panel meter, recorder, PID Controller or PLC. Programmable 4-20mA and voltage outputs, as well as RS232 and RS485 communications Built-in human interface with an intuitive text-based menu for sensor adjustments Rugged NEMA4X (IP65), NEMA7, and CENELEC enclosures An optional Interface Module and ProView PC Software are available for remote display and data logging capabilities To simplify sensor installation and provide added protection in severe environments, Williamson also offers a wide selection of innovative options and accessories including mounting brackets, flanges, water cooling and air purge 2 year warranty Pro 80 Pro 100 Greater Accuracy Advanced Capabilities of Dual and Multi-Wavelength Sensors The Pro body materials and difficult applications. Greater Reliability Industry-leading signal dilution capability eliminates the need for precise alignment and improves the accuracy in hostile environments where the target energy is diluted by intervening media. Williamson s patented ESP Filters (1) enable dual and multi-wavelength sensors to recognize extreme intermittent measurement conditions and only report valid temperature values. Simple Installation and Operation Pro 90 Pro 200 Text-based menu system assures easy setup and operation. A complete selection of wavelengths, optics, sensor configurations, and accessories enables each sensor to be optimized for the requirements of each application. Built-in signal strength/emissivity and signal dilution measurements continuously verify process conditions. For example, these parameters validate sensor alignment and surface properties of metals. (1) Pat. No. 6,840,671 B2 2

Measurement UNEQUALLED PERFORMANCE for DIFFICULT APPLICATIONS The Pro Series dual and multi-wavelength sensors accurately measure temperatures of complex materials under diverse operating conditions. Sample applications are highlighted below. Iron and Steel Ironmaking: Iron Stream, Stove, Coke Guide, Sinter Steelmaking & Caster: Vacuum Melting, Molten Metal Pour, Caster Containment Zone Hot Strip & Plate Mill: Furnace Soak Zone, Rolling Stands, Coiler Wire, Rod, Bar & Structural Mill: Furnace Soak Zone, Rolling Stands, Cooling Bed Finishing: Welding, Annealing, Hot Dip Coating, Heat Treating Tube & Pipe: Centrifugal Casting, Welding, Annealing, Coating, Forming, Heat Treating Foundry: Auto Pour Systems, Investment Die Preheat EASY TO INSTALL, OPERATE, AND MAINTAIN Pro Series sensors are configured using an intuitive text based menu accessed from the sensor, an optional Interface Module, or via a computer with ProView software. Nonferrous Metals Aluminum & Copper Extrusion: Billet, Profile Aluminum & Copper Forging: Billet, Die Aluminum & Copper Rod Mills: Cast Strand, Rolling Stands Aluminum & Copper Strip Mills: Ingot, Breakdown Mill, Finishing Mill, Coiler Nonferrous Drawing, Rolling, Forming and Heat Treating When in the stand-alone mode, the local user interface is used to display the temperature and adjust sensor settings including a programmable output and alarm. Industrial Heating Casting, Forming, Joining & Heat Treating of Metals Induction, Resistance, Friction, Flame and Laser Heating Forging: Billet, Die, Heat Treat Wire Drawing: Annealing, Drawing, Coating Rotary Kilns: Product, Flame Thermal Reactors: Reactor Wall, Fly Ash Solid Fuel Power Boilers: Flame, Fly Ash Glass Forming: Mold Engineered Materials: Carbon Densification, High Temperature Ceramics, Crystal Growing, Plasma Vapor Deposition, Plasma Ion Nitriding Other Industrial Applications The optional Interface Module is ideal for installations requiring remote temperature display and/or multiple programmable outputs and alarms. Wire Forging Foundry PetroChemical Glass Cement ProView PC software can be used to log and analyze data and to make remote sensor adjustments. 3

Innovative Technology for Traditional and Challenging Applications FIBER OPTIC SENSORS The Pro 90 and Pro 200 Class sensors utilize innovative fiber optic features for greater durability and flexibility when installations involve confined spaces or severe environments. These sensors use a small, Teflon-sealed fiber optic cable to view the target while the sensor is mounted in a remote or more convenient location. While the sensor ambient limit is typically 140 F / 60 C, the fiber cables can withstand ambient temperatures as high as 400 F / 200 C or higher with optional accessories. Teflon Sealed Fiber Optic Cable Lens Barrel Field of View ACCURATELY COMPENSATE FOR SURFACE EMISSIVITY CHARACTERISTICS Infrared thermometers collect the infrared energy emitted by an object and convert it into a temperature value. While many factors affect a sensor s measurement accuracy, the most important consideration is the selection of the sensor technology that most effectively compensates for the emissivity characteristics of the measured surface. Emissivity is a term used to quantify a material s tendency to emit infrared energy. It is measured on a scale of 0 to 1.0, and it is related to the reflective and transmission characteristics of a material. For example, a highly reflective surface like aluminum has a low emissivity of 0.1, while a dull surface like refractory brick has a higher emissivity of 0.9. As the figure to the right illustrates, emissivity characteristics can vary with the type of material and the measured wavelength. Consequently, it is important to select the sensor technology and wavelength that most accurately compensates for the emissivity characteristics of the material. The table below provides some guidelines to help select the most appropriate sensor technology for each application. Sensor Williamson Sensor Selection Guide Application Characteristics Single Wavelength T > -40 F / -40 C Surface Emissivity Characteristics Spectral Emissivity 1.0 0.8 0.6 0.4 0.2 Blackbody/Near Blackbody = High and constant emissivity Greybody = Lower and changing emissivity NonGreybody = Low and changing emissivity that varies by wavelength 1 2 3 4 5 6 7 8 9 10 Wavelength (µm) Target The fiber optic sensors feature cable lengths ranging from 3 to 30 feet (1 to 9 meters) as well as a variety of unique mounting and protective accessories for hostile operating conditions. This includes a choice of: Standard glass (G) and quartz (Q) fiber optic cables or optional 0.05in/1.3mm diameter monofilament (M) cables are available Flexible, lightweight Stainless Steel Braid (SSB) with built in Air Purge for extra mechanical protection Heavy Duty ArmorGurard (AG) with built in Air Purge for the ultimate mechanical protection Silver C,M,U (line of sight) Gold 20 (Laser) Gold 30 (Fiber optic) PRO 40 (Visual) PRO 50 (Fiber optic) PRO 80 (Visual) PRO 90 (Fiber optic) PRO 100 (Visual) PRO 200 (Fiber optic) Single-wavelength sensors tend to measure an average temperature value of the measured target area. Short wavelengths are recommended to reduce errors due to optical obstructions and emissivity variation. Advanced signal processing techniques enable broad temperature ranges, measurement of low temperatures with short wavelengths (auto null sensors), and long term calibration stability. Recommended applications involve: Most materials possessing a high and constant emissivity An unobstructed view of the target with a full field of view Low temperature measurements of low emissivity materials Dual Wavelength T > 200 F / 95 C Dual-wavelength sensors tend to measure the hottest temperature viewed in the target area. They provide automatic compensation for emissivity variations of greybody materials. With a unique single-detector design and the industry s highest signal dilution factor, Williamson s dual-wavelength sensors outperform all other ratio sensors. Recommended applications involve: Materials such as ferrous metals which have low and varying emissivity values Intervening media such as dirty optics, scale, steam, dust, or water spray A partially filled field-of-view caused by a mechanical obstruction or a small or wandering target Multi Wavelength T > 200 F / 95 C Multi-wavelength sensors utilize ESP algorithms to provide aim-and-read capabilities for non-greybody materials that are not accurately measured by single and dual-wavelength sensors. Recommended applications involve: Non-greybody materials such as annealed, galvannealed, and stainless steels as well as aluminum, brass, copper, and zinc Intervening media such as dirty optics, scale, steam, dust, or water spray A partially filled field-of-view caused by a mechanical obstruction or a small or wandering target. Some applications do require a full field-of-view with multi-wavelength sensors. 4

GREATER ACCURACY, RELIABILITY, AND REPEATABILITY As the figure and table below illustrate, accurate temperature measurements require careful consideration of many application issues, and with the advanced capabilities of the Pro Series, Williamson simplifies these issues to out perform all others. General Features and Benefits Misalignment and Opaque Optical Obstructions Small or wandering Targets Water, Steam, Clean Flames, Combustion Gasses, Plasma, Diode & YAG lasers Temperature Gradients or Surface Scale Low-Temperature Measurements Emissivity and Signal Dilution Measurements Advanced ESP Filtering Background Reflections Full Field of View Target fills the measured area Spray Plasma Steam Dust Smoke Sensor Field of View Intervening MEDIA Partially Filled Field of View Target does not fill the measured area, but it is centered in the area Williamson s Advanced Design vs Traditional Technology Williamson Dual-Wavelength With a unique single detector design, these sensors offer long-term calibration stability, flexibility to select the optimal wavelengths for advanced measurement requirements, and an industry leading signal dilution capability for measurements with low energy conditions. Signal dilution capability is 20 to 100 times greater than two-color models, producing stable temperature readings were two-color sensors falter or fail. By measuring the hottest spot within a relatively large optical area, the sensor maintains alignment to the target. The optimal wavelengths are selected to view through each of these common optical obstructions without error. Produces a 20-times-greater heavilyweighted average towards the hottest temperature viewed (1) due to a greater separation between wavelengths. Able to measure temperatures 200 F / 95 C and above. Included in all models and useful for sensor and process diagnostics. Included in all models to eliminate intermittent interferences. Partial Obstructions Dirty Windows Target Area Wandering Field of View Target does not fill the measured area, and it moves within the area Traditional Two-Color / Ratio With a two detector design that mounts one detector on top of the other, these sensors are susceptible to long-term drift, a limited choice of wavelengths, and a reduced signal dilution capability that limits their performance on many applications. Signal dilution capability limited by top detector obstructing bottom detector s view and inability to select operating wavelength. High resolution optics with small spot sizes require precise alignment to the moving target. Each of these common optical obstructions creates an error due to restricted wavelength options. Cooler temperatures are averaged into the temperature reading causing a less accurate measurement. Most brands are limited to high temperatures only. Not available. Not available (1) A temperature gradient or surface scale that produces a 60 degree error for a twocolor sensor will produce an error of only 3 degrees for select dual-wavelength models. ACCURATE MEASUREMENTS UNDER ADVERSE CONDITIONS The Pro Series dual and multi-wavelength sensors use state-of-the art technology to provide superior accuracy, reliability, and repeatability to satisfy virtually any application requirement. This includes measurements with: Emissivity Variation: Dual-wavelength sensors are appropriate when emissivity varies equally across wavelengths (greybody materials). A multi-wavelength sensor is recommended when emissivity change varies by wavelength (non-greybody materials). Optical Obstruction: The ability to tolerate optical obstruction is measured by the sensor s signal dilution capability. Williamson sensors offer the highest signal dilution capability in the industry with typical values 20 to 100 times greater than two-color sensors. Optical Interference from Intervening Media: Water, steam, combustion gas, plasma and laser energy possess different transmission properties at different wavelengths. Thoughtful wavelength selection is essential to assure that the sensor is able to view through these interference sources without error. Scale and Temperature Gradients: The greater the wavelength separation the greater is the tendency to measure only the hottest temperature viewed. Select Williamson sensors tolerate surface scale and temperature gradients 20 times better than two-color sensors. OPTIMAL WAVELENGTHS Williamson s innovative technology permits the selection of the optimal wavelengths for a wide range of application requirements. This includes unique capabilities such as measurement through steam, water (see figure), and plasma coatings as well as low temperature dualwavelength measurements. With a two detector design, the traditional two color/ratio sensors are restricted to use 0.7-1.1μm and 1.0-1.1μm wavelengths. Transmission (%) 100 80 60 40 20 0 Transmission thru 0.375 in. of Water Transmission thru 0.094 in. of Water 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 Wavelengths (Microns) WILLIAMSON SENSOR WAVELENGTHS 5

ESP Technology Provides Greater Accuracy, Reliability, and ADVANCED CAPABILITIES THAT ARE EASY TO USE With an easy-to-use text-based menu system, the Pro Series sensors can be configured for a variety of process monitoring and control applications. The menu system can be accessed from the sensor, an Interface Module, or via ProView PC software. The menu is organized as follows: Signal Conditioning Average Time Peak/Valley Hold Temperature Scale ( F/ C) E-Slope Offset Rate of Change Multiplier Configure Inputs and Outputs Select Parameter Select Scale (4-20mA, 0-20mA) Configure the Output Range Configure Remote Input for E-Slope or Alarm Set Point Configure Alarms Select Parameter Select Set Point Value Configure ESP Select Application Algorithm (only available with multiwavelength sensors) Enable ESP Filter Select Range for ESP Filter Average Time for Signal Strength and Signal Dilution Diagnostics Analog Output Test Alarm Test Menu Lockout Status Messages Out of Temperature Range ESP Filter Status High Ambient Warning Aiming System Status Status of Digital Communications SIMPLIFY SENSOR INSTALLATION, OPERATION AND MAINTENANCE The Pro Series dual- and multi-wavelength sensors are able to characterize and compensate for a wide range of application conditions because they continuously measure five unique parameters. Each parameter can be viewed on the sensor s displays or sent elsewhere via programmable outputs and alarms. To verify the accuracy of a sensor s temperature measurement, simply check the measured signal strength and/or signal dilution to confirm they are in a normal range for the application. For example, abnormally low values can indicate misalignment, an optical obstruction, or a dirty lens/window abnormally high values can indicate a high temperature interference or background reflections Temperatures Pro Series Parameters Filtered Temperature: The measured target temperature with signal conditioning filters applied. Adjust the signal conditioning settings as required to achieve the desired readings. Unfiltered Temperature: The measured target temperature with no signal conditioning filters applied. It can be viewed simultaneously with the filtered temperature to better understand the measurement conditions. Signal Strength/Emissivity: The signal strength value is a measure of the effective emissivity. When the sensor s field-of-view is filled. With no sight path interference or background reflections, this value represents the emissivity of the measured surface. Signal Dilution: Signal dilution is a relative measure of the infrared energy received from the target. A signal dilution value of 500:1 indicates the sensor is collecting 500 times more infrared energy than is required to make a reading. Ambient Temperature: The ambient temperature inside the sensor is measured to verify that the sensor is within its ambient operating limits. A status message is displayed when the limits are exceeded. ESP FILTERS ASSURE VALID MEASUREMENTS with applications involving an extreme intermittent interference While Williamson s dual- and multi-wavelength sensors outperform all others with application issues such as flames, hot background reflections, steam, and smoke, there are applications where extreme, intermittent conditions make it difficult to maintain an accurate temperature measurement. With these applications, Williamson s patented ESP Filters can enable the sensor to recognize and ignore these troublesome intermittent error sources. This advanced feature is easy to use and is popular for measurement of molten metal streams, forging dies, and any measurement with extreme intermittent interferences. With the ESP Filters, the sensor is programmed to read a real-time temperature value only when the measured signal strength and/or signal dilution values are within their normal range. If an interference causes these values go out of range, then the sensor can be configured to: hold the last valid reading until the valid measurement conditions resume display no reading at all and a status that the ESP filters are out of range In either case, the reported sensor reading is unaffected by the interference. The two figures below compare the measurements of a sensor without ESP to a sensor with ESP and the hold feature enabled. With ESP Temperatures Without ESP Without ESP With ESP Signal Dilution Signal Dilution Intermittent Reduction of Energy Due to Intervening Media Intermittent Increase in Energy Due to High Temperature Interference / Reflection 6

Ease of Use ESP ALGORITHMS CORRECT FOR EMISSIVITY IRREGULARITIES Single- and dual-wavelength (i.e. ratio or two-color) sensors are unable to provide accurate and reliable temperature measurements on non-greybody materials due to their complex emissivity characteristics. By using application specific ESP algorithms, Williamson s multi-wavelength infrared thermometers outperform all others on these challenging non-greybody materials. With greater temperature measurement accuracy, Williamson s customers are able to achieve new levels of process control for applications previously considered difficult and impossible to measure. Typical non-greybody materials include: Multi-wavelength sensors use ESP algorithms to characterize infrared energy, emissivity, and the measured wavelengths to accurately calculate the temperature and emissivity of complex non-greybody materials. These algorithms are computer-based empirical models developed from extensive data collected from off-line simulations and on-line trials. Each multi-wavelength sensor can include up to four menu-selectable, factory-programmed ESP algorithms plus a dual/ratio mode for dual-wavelength measurement. ESP algorithms may be combined with ESP filters to enable measurement of non-greybody materials under adverse operating conditions. Popular multi-wavelength applications include: Aluminum and Copper Extrusion, Forging, Continuous Casting and Rolling Continuous Annealing of Steel and Stainless Steel Strip and Tube Zinc-Coated Steel Strip and Tube Heating, Forming and Annealing of High-Silicon and High-Nickel Steel Alloys, including high strength steels, rail steel, high-temperature steel, electrical steel and motor rotors Chrome, Stainless Steel and Iron Molds for Glass Forming Measurement of all non-grey metals listed above An example of a popular multi-wavelength application is a steel continuous annealing line. As the graph below illustrates, single- and dual-wavelength sensors can produce significant errors as the emissivity and e-slope vary while the Williamson multi-wavelength technology is able to accurately correct for these variations which are due to: Changes in alloy, surface texture, surface oxidation, grain growth, elemental migration Abnormal operating conditions, such as a furnace leak, a bad roll, or a reheated coil These results are achieved under a wide range of operating conditions without any adjustments to the multi-wavelength sensor. Temp. (F ) Error Aluminum Brass Bronze Chromium Copper 150 125 100 75 50 25 0-25 -50-75 Magnesium Manganese Molybdenum Nickel Silicon Multi-Wavelength Sensors on Steel Annealing Lines Single-Wavelength Sensor: 1 λ Emissivity Setting = 0.3 2 λ Multi-Wavelength Sensor: Μ λ ESP Algorithm = Annealing Stainless Steel Tin Titanium Tungsten Zinc Dual-Wavelength Sensor: E-Slope Setting = 1.0 0.20 0.30 0.40 0.50 0.60 Surface Emissivity 78 67 56 44 33 22 11 0-6 -11-22 -33-44 Temp. (C ) Error DUAL AND MULTI-WAVLENGTH SENSOR SPECIFICATIONS Temperature Limits 200 to 4500 F / 95 to 2500 C Accuracy 0.25% of Reading or 2 C whichever is greater Repeatability Better than 1 C Response Time 100ms (95% of Response) update time is 50ms E-Slope (E-Slope Offset) 0.000 to 2.000 (+/- 1.000) Input Power 24Vdc (300mA) Analog Outputs 4-20mA, 0-20mA, or voltage outputs and a TTL alarm Digital Communications RS485 or RS232 Ambient Temperature Limits 0 to 140 F / -17 to 60 C 0 to 120 F / -17 to 50 C (some low temperature models) With Water Cooling limit is 350 F / 175 C Fiber Optic Assembly limit is 400 F / 200 C Enclosure Corrosion Resistant, Aluminum Cast Enclosure with NEMA 4X (IP65) Rating. Optional NEMA 7 and CENELEC enclosures are available INTERFACE MODULE SPECIFICATIONS For installations requiring remote temperature display and advanced programming capabilities, the interface module offers the following: 2 programmable 4-20mA, 0-20mA, or voltage outputs 1 programmable 4-20mA, 0-20mA, or voltage input 2 programmable SPDT relay alarms Bi-directional RS485/RS232 communications Built-in power supply with 90-260Vac input Note: Assumes Strip Temperature of 1400 F (760 C) 7

Unequaled Performance in Temperature Measurement Williamson Overview With the Silver, Gold, and Pro Series sensors, WIlliamson offers a complete range of infrared thermometers to provide accurate and reliable measurements for traditional and challenging applications. The Silver Series offers miniature, low cost configurations for many general purpose applications. The Gold Series offers a complete selection of wavelengths, optics, and configurations for traditional and challenging applications including heavy industrial environments. The Pro Series offers the most advanced capabilities with a complete selection of wavelengths, optics, and configurations for traditional and challenging applications including heavy industrial environments. A COMPLETE RANGE of infrared thermometers for every application Silver U Class Silver C Class Silver M Class Class Sighting Single-Wavelength Sensors Silver C, M, & U Line of Sight Gold 20 Line of Sight or Laser Gold 30 Fiber optic w/ Aim Light Pro 40 Visual or Laser Pro 50 Fiber optic w/ Aim Light Dual-Wavelength Sensors Pro 80 Visual or Laser Pro 90 Fiber optic w/ Aim Light Multi-Wavelength Sensors Pro 100 Visual or Laser Pro 200 Fiber optic w/ Aim Light For more details on Single-Wavelength models, see Williamson s Single-Wavelength Industrial Infrared Thermometers brochure and data sheets. Sample Industries Served Iron and Steel Nonferrous Metal Industrial Heating, Thermal Surface Treatment Engineered Materials, Semiconductor Glass and Ceramics including Bricks, Cement, Glass, and Refractory Incinerators, Boilers, Rotary Kilns, Flares, Thermal Reactors Paper, Textile, Plastic, Rubber Pharmaceutical Food Aggregate, Ores, Soil and Asphalt Gold 20 Pro 40, 80, 100 Gold 30 Pro 50, 90, 200 DMWL Rev. 0 WILLIAMSON CORPORATION 70 Domino Drive, Concord, Massachusetts 01742 TEL: (978) 369-9607 FAX: (978) 369-5485 (800) 300-8367 (USA) sales@williamsonir.com www.williamsonir.com