T H E CHA R L E S T O N S E R I E S

Similar documents
REPLACEMENT PARTS LIST WARNING

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

GETZ MANUFACTURING PART # CYLINDER DRYER

GA3650TB Blower Accessory

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

Bathroom Exhaust Fan/Fluorescent Light Combination

MaxLite LED Vapor Tight Linear Fixture

Bathroom Exhaust Fan/Fluorescent Light Combination

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Sound Cover [ , , , ]

MaxLite LED High Bay Fixtures

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

Industrial Vacuums, Inc

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

Installation Instructions

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

Expanded Backup Control Installation & Operator s Instruction Manual

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

INSTRUCTION MANUAL HS-229G

SYSTEM CONTROL KIT Model: CK-41P

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 2021 NEFE AM-1 ELECTRIC FIREPLACE MANTEL

MODEL ZCVF36 MODEL ZCVF42

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

NorthlineExpress.com Toll-Free

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Cordless Electric Broom

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

MaxLite LED Round Pendant Highbay Series

MaxLite LED MICRO-T PANEL

DUST FREE CARBON Whole House Air Purifier

PORTABLE AIR CONDITIONER OWNER S MANUAL

Easy installation in both new construction and retrofit

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

ELECTRIC FIREPLACE OWNER S MANUAL


INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

FW-RA-LED Remote Multiplex Annunciator Panels

Installation & Maintenance Instructions

Instruction Manual. Nacho Cheese Dispenser and Warmer

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

User s Manual & Operating Instructions

Wax Base Heater & Dispenser

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

OWNER'S MANUAL. 12W6v3 Subwoofer Driver

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

FloorHeat Installation Manual

PORTABLE AIR CONDITIONER OWNER S MANUAL

Model SBF-300 Circulator INSTALLATION AND OPERATING INSTRUCTIONS

Installation & Operation Manual Ice Cream Freezers

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

Design Criteria. Installation

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

Installation Instructions

Air Pump Up to 800 gallons

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Inline Heater for Solvent or Gas. Installation and Operation Manual

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

Instruction Manual for the Globe Mixer. Model SP8-RL

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ETL CHFP-50A ELECTRIC FIREPLACE ! WARNING

Robotic Vacuum. Operation Manual P4900

User s Manual and Operating Instructions

MH70230AS MH70236AS MH70248AS

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

3 Scotch Mini-Weld Adhesive System User s Manual

TAILORED S PECTRUM. Commercial Grow Luminaire SQRT670CX1 INSTRUCTION MANUAL

TrueClean ToteCleaner

16" and 20" Economy Incandescent Full Hoods Owner s Manual

Spa Control System OWNER S MANUAL

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

64&3 (6*%& Distributed by! ALDI, INC.! Batavia, IL 60510!

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

1 HP Air Mover. Owner s Manual

Please consider the option to recycle the packaging material and donate any appliance you are no longer using.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Installation Instructions

O w n e r s M a n u a l

Part No Revised November / Instruction Manual Model #8150 AND #8151

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

OWNER'S MANUAL RSL MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local:

User s Manual and Operating Instructions

Classic & Deluxe Pants Press SPP-0669 SPP-0670

e Bath Fan with Light User s Guide

D E S I G N G U I D E REVISED 10 / 2017

Easy installation in both new construction and retrofit

D E S I G N G U I D E REVISED 9 / 2018

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

MODEL HBX-1 P/N 3G59332

SEALING FIBER SEALING COMPOUND

15-Year Limited Warranty

Transcription:

T H E CHA R L E S T O N S E R I E S BLOWER (MODEL # BL-101) FOR VENT FREE UNIVERSAL FIREBOX MODEL NUMBERS: VFB(C)32 VFB(C)36(A) VFB(C)42(A) Installation Instructions:Circulating Air Blower! WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

I n s t a ll a t i on I ns t r u c t i o n s INSTALLER/CONSUMER SAFETY INFORMATION READ AND SAFE THESE INSTRUCTIONS. This book contains your installation instructions and should be kept in a safe place. For you to realize all of the advantages and use of the reliable service that has been engineered into your Sure Heat Manufacturing Fireplace, you must carefully follow all of the instructions contained in this manual regarding installation and operation of the fireplace. It is suggested that you wear work gloves and safety glasses to protect your hands and eyes when installing your Blower Kit. These Instructions should be read carefully in their entirety before beginning installation of the Blower Kit. Electrical Junction Box Wiring should be connected at provided junction box, in the firebox, prior to the installation of the Blower Kit. See instruction on page 3. Electrical Services If an electrical supply of 120V has been roughed in to the fireplace junction box to provide for installation of the optional blower kit, the wiring should be connected to the junction box. NOTE: A FEW BASIC SAFETY RULES BEFORE YOU START: A. Make sure you have and and are using/wearing proper personal safety devices such as, but not limited to: gloves, safety eye glasses/eye protection. B. Check to ensure that electrical service has been provided to the junction box located in the bottom chamber of the firebox. C. Check local building codes before installation of the Blower Kit. D. All wiring must be installed and/or inspected as necessary to comply with the local authority having jurisdiction. E. The circuit breaker controlling the power supply to the pre-wired junction box in the appliance must be in the OFF position before beginning installation of the Blower Kit. 2

Installation Instructions Optional Electrical Junction Box Junction Box Wiring If installation of an accessory blower, or other linevoltage powered accessory MAY be desired, you should install the J-Box accessory, and wiring at the time of fireplace installation. IT WILL NOT BE PRACTICAL TO INSTALL THIS LATER! 1. Remove (2) J-box retaining screws. (See Fig. 3) 2. Install J-Box Assembly into Fireplace (See Fig. 4) Wiring should be connected at a customer provided junction box, outside the firebox. 3. Attach household 110 VAC supply wire to Receptacle. Electrical Services 4. Tighten Cable Clamp, install Receptacle and Cover If an electrical supply of 120V is being roughed in to the fireplace junction box to provide for future installation of the optional blower kit, the wiring should be connected to the internal J-Box (junction box) kit (PROVIDED WITH THIS ACCESSORY). 6. Verify operation of outlet assembly in Fireplace NOTE: A FEW BASIC SAFETY RULES BEFORE YOU START Fig. 2 1. All electrical connections (Fig. 1) are to be made in accordance with CSA Standard C22.1 Canadian Electrical Code part 1 or with the National Electrical Code, ANSI/NFPA 70 (latest edition) and/or in accordance with local codes. 2. Make sure you have and are using/wearing proper personal safety devices such as but not limited to gloves, safety eye glasses/eye protection. 3. Check local building codes before installation of the firebox and blower kit. 4. All wiring must be installed and/or inspected as necessary to comply with the local authority having jurisdiction. INSTALLER: WIRE INTERNAL RECEPTACLE TO 110VAC HOUSE WIRING PER APPLICABLE LOCAL CODES Fig. 3 FIREBOX ENCLOSURE STEEL HANDI-BOX W/SINGLE GANG RECEPTACLE BLOWER MOTOR ACCESSORY M Fig. 4 SPST BLOWER SWITCH VFBC BLOWER WIRING DIAGRAM, ALL SIZES Fig. 1 Outlet wil be positioned horizontally in models VFBC36 A and VFBC42 A 3

i n s ta l l a t i o n i n s t r u c t i o n s Step 1 Installing Blower Kit - Model BL101 Step 1. Remove Blower Access Panel. Use 1/4 nutdriver to remove four (4) screws. The access panel will be located toward the front in models VFBC36A and VFBC42A. Step 2 Step 2. Place Blower Cable in box. Route switch terminals through firebox side and then up and out through the switch hole on the Front Side panel on VFBC32,36 and 42. The switch will be located in the front right corner of the fireplace floor on VFBC36A and VFBC42A. Step 3 Step 3. Slide connectors onto the spades on the back of the switch (wires can be connected to either terminal). Bend tabs slightly downward only on VFBC32,36 and 42. Step 4 Step 4. Slide Switch and wire terminals back into the switch hole. Firmly seat the switch to lock in place. 4

Installation Instructions Installing Blower Kit - Model BL101 (cont.) Step 5. Step 5a. a. Attach red and black wire connectors to blower motor terminals. b. Set blower onto firebox bottom. Step 5c. c. Attach green ground wire to self-tapping screw to back firebox panel. FIREBOX ENCLOSURE INSTALLER CONNECT TO 110VAC HOUSE WIRING PER APPLICABLE LOCAL CODES STEEL HANDI-BOX W/SINGLE GANG RECEPTACLE BLOWER MOTOR ACCESSORY M! DANGER: DO NOT ATTACH RED OR BLACK WIRE TO BACK FIREBOX PANEL! Self-tapping screw SPST BLOWER SWITCH WIRING DIAGRAM - AL L SIZES - Step 6. Peel off backing of Velcro hold down pads, insert blower into unit, align properly, and firmly press down to attach to Firebox Base. On models VFBC32,36 and 42 the velcro will be facing the fireplace floor with the outlet of the blower pointed rearward. Models VFBC36A and VFBC42A the velcro will be between the blower and fireplace back with outlet of the blower pointing upward. Step 7. Plug Blower Power Cable into supplied receptacle. Turn power ON and test unit. Step 8. Replace Blower Access Panel. Step 6. Step 7. Step 8. NOTE: If you are uncertain or unclear with any instructions or parts, STOP and immediately contact the seller or manufacturer listed on these instructions for further explanation and/or direction. 5

Limited One Y e a r W a rrant y Limited Warranty shall apply to the original purchaser at the original installation point only. The Blower components are warranted for one year to the original owner, subject of proof of purchase. General Warranty: This Limited Warranty will be void if the appliance is not installed by a qualified installer in accordance with the installation insructions. The Limited Warranty will also be void if the appliances is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to 1) blower damage by accident, neglect, misuse, abuse, alteration, negligence of others, including the installation thereof by unqualified installers, 2) the costs of removal, reinstallation or transportation of defective parts on the appliance, or 3) incidental or consequential damage. All service work must be performed by an authorized service representative. This warranty is expressly in lieu of other warranties, express or implied, including the warranty of the merchantability of fitness for the purpose and of all other obligations or liabilities. Sure Heat Manufacturing does not assume for any other obligations or liabilities in connection with the sale or use of the appliance. In states that do not allow limitation on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you. You may also have the additional rights not covered in this Limited Warranty. Sure Heat Manufacturing reserves the right to investigate any and all claims against the Limited Warranty and decide upon method of settlement. All costs for removal and reinstallation are the expressed responsibility of the purchaser. Servicing: Repair and replacement work should only be done by a qualified service person. Always shut off the gas supply and make sure the appliance is cool before beginning any service operation. For repair or replacement of a defective part or parts, contact our Customer Service Department at: 1-800-229-5647 You will be asked to provide valid warranty registration, proof of purchase and model number. Purchased From : Date: Model: BL-101 Name: Date: Address : City : State: Zip: Phone : ( ) Contact Sure Heat Manufacturing for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Sure Heat Distributor or Dealer. You will need the correct name, part number and model number of the appliance when ordering replacement parts. Should you need additional information beyond what your dealer can furnish, contact: Sure Heat Manufacturing 1861 West Oak Parkway Marietta, GA 30062 www.sureheat.com RMH-130-0073 07/2012