HERO SERIES-DC INVERTER HEAT PUMPS

Similar documents
BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

Air-to-water Heat Pump Monobloc Versati

S-Therm Air to Water Heat Pumps

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Multi Inverter Air Conditioning Condensing Units - Summary

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Air-cooled modular Chiller. Nick Technical Engineer

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C


AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

DC inverter VRF presentation

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Product Line Introduction. Karl Zhang Technical support engineer

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

MODULAR CHILLER. R410a R22

EVI Scroll Air To Water Heat Pumps

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

HEAT PUMP. Dongguan New Times New Energy Science & Technology Co., Ltd.

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

HEAT PUMPS MANUFACTURING EXPERT CUBIC CUBIC. Catalog. Cubic Electrical Appliance Co., Limited

Air Conditioning System

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

AIR COOLED CONDENSING UNIT

AHU Plus. DX Air Handling Units

Technical Guide. Split Air-Conditioners Equipment Residential COS Series

PAC BT LOW TEMPERATURE HEAT PUMP

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

All DC Inverter Multi VRF

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

Aperçu de la gamme Therma V

DC Inverter Smart VRF Products(R410A)

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

DAIKIN Modular Inverter Air Cooled Chiller

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Lennox Mini-Split Systems Year-Round Comfort and Performance

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Call or visit solarshop.com.au

Service manual. MIV V4+ Mini

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Inverter Ducted Air Conditioners

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Q Series. Inverter Split Systems

V017-EN-01 AIR TO WATER HEAT PUMPS HEART OF YOUR HOME

Cozy Hi Wall Inverter Air Conditioner

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Floor-Standing Type(E Series)

Submittal Data Sheet

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

Air cooled industrial chillers

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

2009 Panasonic Marketing Europe GmbH / All rights reserved

DAIKIN Huizhou Factory Profile

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

we care about Better Air

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

K sin. Mini Split Air Conditioners and Heat Pump

Heat pump & cooling unit in one

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

Advance Split

Aqua 1 plus Air-water heat pumps for domestic hot water production

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

PRODUCT LINE-UP Residential & Light Commercial air conditioners

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

[U] Serie MOV. Manual de Ingeniería

Modular Air Cooled Scroll Chillers

HEAT PUMP & HEAT PUMP & SOLAR HYBRID SOLAR HYBRID AIR CONDITIONER AIR CONDITIONER

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

V016-EN-01 AIR TO WATER HEAT PUMPS 2016 HEART OF YOUR HOME

Air to water Heat Pump System

Condensing Units w/ Screw Compressors

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Transcription:

HERO SERIES-DC INVERTER HEAT PUMPS PHNIX DC inverter heat pump can work efficiently with floor heating, water fan coils or radiators for heatingcooling.

WATER FAN COILS DC INVERTER HEAT PUMP FLOOR HEATING TANK + OR DC INVERTER HP PHNIX DC inverter heat pump can work efficiently through floor heating, water fan coil or radiator heatingcooling. The monobloc design makes it easy for outdoor installation. FLOOR HEATING Floor heating application makes the heat evenly distributed in the room. FAN COIL OR RADIATOR The water fan coil designed by PHNIX, is with DC fan motor inside and uses precise temperature control. The Hero Series also work with standard radiators, reaching 55 o C outlet water.

PHNIX ADVANCED HEAT PUMP TECHNOLOGY ENERGY SAVING UP TO 30% With the use of inverter compressors, brushless DC fan motors and PFC control method, the units can regulate the running capacity. With no frequent start-ups and stop runnings, the units work in stable condition with high efficiency. The energy consumption is 30% less than that of standard heat pump units. SAVE 30% 0.5 O C PRECISE CONTROL The units can change the operating frequency of the compressors automatically according to the heating or cooling demand. When the target temperature is reached, the units run at a lower frequency, and the temperature control accuracy can be as precise as 0.5 o C. Temperature 20 Heating Fast start-up Little temperature fluctuation The compressor adjusts the frequency according to the water temperature. SPEED UP HEATINGCOOLING TIME When there is a large difference between the actual temperature and the programmed temperature, the unit can run at a higher frequency to make fast heating or cooling to increase or decrease the temperature rapidly. Temperature Fast heating Set temperature Too hot Too cold Start up Standard heat pumps PHNIX inverter heat pumps

INTELLIGENT DEFROSTING Traditional Defrosting Method Traditional defrosting method is with fixed defrosting time and start temperature. Once the ambient temperature reaches or is lower than -7 o C, the unit will start defrosting. It's easy to cause energy wasting when there is no defrost and will reduce the heating performance at the same time. Intelligent Defrosting Method Hero series intelligent defrosting uses the pressure sliding defrosting technology to figure out the exact defrosting time and start pressure according to the real ambient temperature. It saves energy and makes the heat pump work in high efficiency. 13bar Defrosting Temperture Traditional Pressure Sliding Hero series Ambient Temperature NO FROSTING IN THE BOTTOM With the use of the special liquid distribution technology, in heating mode, the temperature of refrigerant in the air exchanger s bottom copper tube will not decrease in order to ensure no frosting on it and smooth drainage. WIRE CONTROLLER PHNIX self-developed wire controller with glass panel and touch screen can be installed on the wall inside the house. It provides you a convenient way to control the heat pump and is applicable to RS485 communication. CORE COMPONENT The use of the famous and reliable brand compressor ensures the unit working in the perfect performance.

FINNED HEAT EXCHANGER The finned heat exchanger uses riffled copper tube which Riffled Copper Tube greatly improves the heating efficiency. Louvered fins with greater airflow distribution effectively improve the heat exchanging efficiency. Louvered Louvered Fins TUBE-IN-SHELL HEAT EXCHANGER Refrigerant Cooling Water Copper Tube Cross Section Cooling water and refrigerant circuit is of counter current design, which ensures the refrigerant outlet subcooling and improves the performance of the heat pump system. Spiral copper coil enlarges the water heat exchanging area so that the water can sufficiently exchange heat with gas. Gas Refrigerant Shell Liquid Refrigerant It s not easy to cause lubricant retention because of the small gap between the refrigerant circuit and shell. It makes the lubricant flow smoothly. 5.0MPa Pressure Test No welding point inside the Water Coil There is no welding point inside the water coil which avoids the leakage of the refrigerant. 5.0MPa pressure test ensures the heat exchanger always work stably.

Model H8A H15B H25T H30T HERO SERIES-DC INVERTER HEAT PUMPS Heating Capacity Range 2.5 10.8 5.0 17.3 7.0 25.1 10.0 33.0 Heating Power Input Range 0.8 2.77 1.2 4.55 2.5 6.54 5.0 9.07 Cooling Capacity Range 2.0 10.0 5.0 14.5 7.0 20.0 9.0 24.0 Cooling Power Input Range 1.0 3.4 1.6 5.6 2.5 9.0 3.5 10.0 Frequency Hz 30 90 ErP Level (35 C) ErP Level (55 C) A+ Power Supply 208-240V~50Hz 380-415V3N~50Hz Electric Heater 3.0 6.0 Max. Running Current A 18.0+13.7 27.0 14.0 18.0+11.0 Refrigerant R410A Compressor Brand Mitsubishi Electric Mitsubishi Electric Mitsubishi Electric Hitachi Water Pump Brand Water Connection 1" 1 14" 1 14" 1.5" Water Pump Head m 12.5 22 23 21 Fan Motor (DC or AC) Type DC DC DC AC EEV Brand Pressure Sensor 1 Bar Pressure Sensor 2 Bar Noise db(a) 54 58 62 64 Net Weight kg 110 163 219 337 Gross Weight kg 123 180 243 383 Net Dimension (LWH) mm 980465900 9903951320 11754001588 110010001635 Shipping Dimension (LWH) mm 1010486910 10304151330 12905301760 114010401650 Operation Ambient Temp. C -20~52 The above data is tested under: Heating: Ambient Temp.(DBWB): 7 C6 C, Water Temp.(InOut): 30 C35 C. Cooling: Ambient Temp.(DBWB): 35 C24 C, Water Temp.(InOut): 12 C7 C. GUANGDONG PHNIX ECO-ENERGY SOLUTION LTD. TEL: +86-4009400900 FAX: +86-20-39067770 E-mail: phnixen@phnix-e.com Website: www.phnix-e.com