This manual must be kept with the appliance

Similar documents
FASTflo. Working towards a cleaner future

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Sirius FS. Working towards a cleaner future

Sirius WH. Working towards a cleaner future

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Multipoint Technical Data

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

INTA ION MODERN BAR / BATH SHOWER MIXER CP

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Installation and Servicing Instructions. Alpha FlowSmart

Installation and Servicing Instructions. Alpha GasSaver GS-1

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Alpha CombiMax 350 and 600

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Copper-Fin GAS-FIRED WATER HEATERS

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

the electric heating company ELECTRIC BOILER HANDBOOK

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

HOT WATER SYSTEMS.

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Broag Pressurisation equipment

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

SATK 30 heat interface unit

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Tried. Tested. Trusted.

SEALED THERMAL STORE

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Hydraulic Installation

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

Black is the new green

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Working towards a cleaner future. Andrews Water Heaters Product Guide. 9.5kW to 550kW

Installation and Servicing Instructions. Alpha GasSaver GS-2

WHHR Midi & Midi Lite

Unvented Hot Water Storage Cylinders Installation and Maintenance Instruction Manual

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

TRIPLE CONTROL THERMOSTATIC SHOWER VALVE

maximise the sun s energy with warmflow solar Warmflow Solar

Installation and Servicing Instructions. Alpha CD50

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION. For Super SXD, SX, SCI & SC

Instructions for Use Installation and Servicing

Alpha FlowSmart 25 and 50

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Stored Water District Heating Interface Units. Heat Interface Units

Link-Up. Solid Fuel Association Guide to Central Heating.

INTADUO THERMOSTATIC BATH/SHOWER MIXER

Series 1000 & Storage Water Heaters

Installation and User Instructions HS10U, HS15U.

Installation & User Instructions

Exceeding the Standard

Installation & Technical Guide. Domestic & Commercial.

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

VAILLANT SPARE PART CATALOGUE

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Super high efficiency heating and hot water boilers for every type of home and commercial property.

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

Installation and Servicing Instructions. Alpha CB50

Instructions for use Installation and Servicing. Unvented Hot Water Cylinders/ Hydracyl

Performance on demand

Installation & User Instructions

Unvented Hot Water Criteria

MAXIMISER Semi-Storage Calorifiers

INSTALLATION GUIDE, OPERATION AND SERVICE MANUAL

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

PLEASE LEAVE THIS MANUAL WITH THE AQUAFLOW UNIT AFTER INSTALLATION. For capacities litres

LBF RANGE BALANCED FLUED WATER HEATERS

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Schuco SS-TC/SC Cylinders

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

StainlessLite HP. Design, Installation & Servicing Instructions. Unvented cylinders specifically designed to work with a heat pump

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

Light commercial products. High output boilers Cascade systems

Unvented water heating

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Transcription:

This manual must be kept with the appliance October 2010 Part No E835 FASTflo Installation Design Guide Continuous Flow Wall Hung Balanced Flue Water Heaters for Natural Gas and Propane WH42, WH56, WHX56, LWH56, WHX56, LWHX56 Working towards a cleaner future

Reproduction of any information in this publication by any method is not permitted unless prior written approval has been obtained from Andrews Water Heaters. Andrews Storage Water Heaters have been designed and manufactured to comply with current international standards of safety. In the interests of the health and safety of personnel and the continued safe, reliable operation of the equipment, safe working practices must be employed at all times. The attention of UK users is drawn to their responsibilities under the Health and Safety Regulations 1993. All installation and service on Andrews Water Heaters must be carried out by properly qualified personnel and, therefore, no liability can be accepted for any damage or malfunction caused as a result of intervention by unauthorised personnel. Andrews Water Heaters policy is one of continuous product improvement and, therefore, the information in this manual, whilst completely up to date at the time of publication, may be subject to revision without prior notice. Further information and assistance can be obtained from: Andrews Water Heaters Wood Lane, Erdington, Birmingham B24 9QP Tel: 0845 070 1055 Fax: 0845 070 1059 Email: andrews@baxigroup.com Website: www.andrewswaterheaters.com THE ANDREWS WATER HEATERS COVERED IN THIS GUIDE ARE FOR USE WITH NATURAL GAS OR PROPANE ONLY Copyright Andrews Water Heaters 2010

Andrews Installation Design Guide for WH and WHX Model Water Heaters Fig No. DESCRIPTION 1 Typical Installation - Single Heater 2 Typical Installation - Single Heater with Secondary Return 3 Typical Installation - Two Heaters 4 Typical Installation - Two Heaters with Quick Connect Cord 5 Typical Installation - Three Heaters with Secondary Return 6 Typical Installation - Four Heaters with Electronic System Controller Kit 7 Technical Note - Water Flow Rates and Performance Chart 8 Typical Installation - Electronic System Controller Kit 9 Technical Note - Unvented System Kits 10 Typical Installation - Single Heater with ST Range Storage Cylinder 11 Typical Installation - Two Heaters with ST Range Storage Cylinder, Quick Connect Cord and Secondary Return 12 Typical Installation - Three Heaters with ST Range Storage Cylinder and Secondary Return 13 Technical Note - Flow Rate Head Loss and Pump Sizing 14 Technical Note - Pump Curves 15 Heater Dimensions - WH56 and LWH56 16 Heater Dimensions - WHX42, LWHX42, WHX56 and LWHX56 17 WH42, LWH42, WH56 and LWH56 Pre-assembled dual manifold unit dimensions 18 WH42, LWH42, WH56 and LWH56 Pre-assembled triple manifold unit dimensions 19 WHX56 and LWHX56 Pre-assembled dual manifold unit dimensions 20 WHX56 and LWHX56 Pre-assembled triple manifold unit dimensions

Fig No.1 Andrews WH and WHX Single Water Heater Installation Without Secondary Return Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details Water Supply Pressure Min 1.0 bar Max 10.0 bar Min flow 3.5 ltrs/min 1 Remote controller kit (part no. B285) Gas Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Dynamic Pressure NG 20 mbar Propane 37 mbar Cold Supply 1. Stop cock HWS flow Hot Outlets

Fig No.2 Andrews WH and WHX Single Water Heater Installation with Secondary Return Water Supply Pressure Min 1.0 bar Max 10.0 bar Min flow 3.5 ltrs/min Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details 5 Remote controller kit (part no. B285) 7 Gas Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Dynamic Pressure NG 20 mbar Propane 37 mbar 1 2 3 4 Cold Supply 1. Stop cock 2. Strainer 3. Pressure reducing valve 4. Non return valve 5. Expansion vessel 6. Expansion valve + tundish 7. Andrews bronze pump c/w ball valve unions (part no. B249) 6 HWS flow Bronze secondary return pump see Fig. No s. 13 and 14 Hot Outlets

Fig No.3 Andrews WH and WHX Multiple Water Heater Installation without Secondary Return Remote controller kit (part no. B285) Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Water Supply Pressure Min 1.0 bar Max 10.0 bar 1 Gas Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Dynamic Pressure NG 20 mbar Propane 37 mbar Cold Supply 1. Stop Cock HWS flow Where output may be below 7 ltrs/min see Fig. No. 4

Fig No.4 Andrews WH and WHX Multiple Water Heater Installation with Quick Connect Cord Kit Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details Single remote controller Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Water Supply Pressure Min 1.0 bar Max 10.0 bar 1 Gas Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Dynamic Pressure NG 20 mbar Propane 37 mbar Cold Supply 1. Stop Cock HWS flow Quick Connect Cord Kit (part no. B286) Hot Outlets

Fig No.5 Andrews WH and WHX Multiple Water Heater Installation with Secondary Return Cold Supply Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details 1. Stop cock 2. Strainer 3. Pressure reducing valve 4. Non return valve 5. Expansion vessel 6. Expansion valve + tundish 7. Andrews bronze pump c/w ball valve unions (part no. B249) 5 6 Gas Remote controller kit (part no B285)* *An Electronic System Controller Kit can be used as an alternative when manifolding up to six units. (see Fig. No s 6 and 8) Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Dynamic Pressure NG 20 mbar Propane 37 mbar 1 2 3 4 4 HWS flow 7 Bronze secondary return pump see Fig. No s. 13 and 14 Hot Outlets

Fig No.6 Andrews WH56 and WHX56 Multiple Water Heater Installation with System Controller Kit Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details System Controller in unit No. 1 (see Fig. No. 8) Single remote controller Water Supply Pressure Min 1.0 bar Max 10.0 bar Gas rate per NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Cold Supply Gas Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr 1. Stop Cock 1 HWS flow Dynamic Pressure NG 20 mbar Propane 37 mbar Hot Outlets

Fig No.7 Andrews WH and WHX Water Flow Rates Performance Chart Andrews Model Temperature Temperature Temperature Temperature Temperature Temperature Reference Rise 25ºC Rise 35ºC Rise 45ºC Rise 55ºC Rise 65ºC Rise 75ºC L sec L min L sec L min L sec L min L sec L min L sec L min L sec L min Water flow at different temperature rises WH42,LWH42 0.40 24.0 0.29 17.4 0.22 13.2 0.18 10.8 0.15 9.2 0.13 8.0 WH56, LWH56 0.53 31.8 0.38 22.8 0.30 18.0 0.24 14.4 0.20 12.3 0.18 10.6 WHX56,LWHX56 0.53 31.8 0.38 22.8 0.30 18.0 0.24 14.4 0.20 12.3 0.18 10.6 The flow rate will vary dependant upon the temperature selected at outlet and the incoming water temperature. The flow rate can be calculated using the following formula or by reference to the charts above. WH42, LWH42 = 42 kw output WH56, LWH56 = 55.8kW output WHX56, LWHX56 = 55.8 kw output Flow rate L/S = (heater output) kw Δt (temperature rise) x 4.2 specific heat In addition to the above the maximum flow through each heater is pre-set independent of temperature, maximum flow rate for the WH42 is 24 L/min and maximum flow rate for the WH56 and WHX56 is 31.8 L/min.

Fig No.8 Andrews System Controller Kit (Part No. B287) for WH56, LWH56, WHX56 The System Controller Kit can be used as an alternative to the Quick Connect Cord Kit (two unit installation) or for controlling up to six manifolded water heaters. The master unit (No.1) contains the System Controller module and includes plug connectors to enable the control cords from the other units to be connected up to the master unit. In addition the System Controller incorporates the following standard features, BEMS fault indication, Remote Power On indication, Primary Pump connection via cylinder thermostat, Secondary Circulation Pump connection and Remote Switching. A comprehensive installation manual is available from our sales department. System controller Kit (Part No. B287) Unit No.6 Unit No.5 Unit No.4 Unit No.3 Unit No.2 Unit No.1 Single remote controller P C B P C B P C B P C B P C B P C B Typical installation System operation The control panel randomly selects some heaters at the ready stage and some at the standby stage, and heaters will start dependent upon water flow and temperature settings. The system rotates the lead and standby units after every eight hours operating time. As the flow rates increases additional units will fire thus maintaining the required system flow temperature. The remote controller must be connected to Unit No. 1 and temperature settings on this controller will be communicated to the other manifolded heaters on the system. The System Controller is not required when the installation incorporates a storage cylinder/ buffer vessel or if a constant large volume of hot water is required.

Fig No.9 Andrews WH & WHX Unvented System Kits If continuous flow water heaters are used on circulation systems or linked to a storage cylinder/buffer vessell an unvented system kit is required to allow for expansion of the hot water system. The kit includes the necessary safety devices required to conform to the current building regulations. Three sizes of kit can be supplied and each contains a combined strainer/pressure reducing valve set to 3.5 bar, check valve, expansion valve set to 6.0 bar, tundish, 5 litre expansion vessel, wall bracket and hose. When the system includes a storage cylinder/buffer vessel, a combined temperature/pressure relief valve must be sized to suit the total input of all the water heaters installed (see table below). This valve must be located at the top of the storage unit (see Fig. No. 10). In addition the size of the expansion vessel must also be increased to suit both the storage cylinder plus the contents of the system pipework (see expansion vessel table). Unvented System Kit Part No. Size B235 3 /4 inch dia. B234 1 inch dia. B276 1 1 /4 inch dia. Expansion Vessel Part No. Size C782 25 litre, 3.5 bar C789 40 litre, 3.5 bar E047 60 litre, 3.5 bar C890 80 litre, 3.5 bar Temperature and pressure Relief Valves Tundishes Part No. Total Output Quantity & Size of Valves Part No. Size C380 Up to 56kw 1 x 1 inch C384 1 inch - 1 1 /4 inch E242 Up to 112kw 1 x 1 1 /2 inch E326 1 1/2 inch - 2 inch E242+C456 Up to 126kw 1 x 1 1 /2 inch + 1 x 3 /4 inch E497 2 inch - 2 1 /2 inch E291 Up to 168kw 1 x 2 inch E497 2 inch - 2 1 /2 inch E291+C380 Up to 224kw 1 x 2 inch + 1 x 1 inch E497+C384 2 inch - 2 1 /2 inch+ 1 inch - 1 1 /4 inch

Fig No.10 Andrews WH and WHX Single Water Heater Installation with ST Range Storage Cylinder 1. Stop cock 2. Strainer 3. Pressure reducing valve 4. Non return valve 5. Expansion vessel 6. Expansion valve + tundish 7. Andrews bronze pump c/w ball valve unions (part no. B249) 8. Combined temperature and pressure relief valve + tundish Remote controller set to 70ºC 1 2 3 4 5 7 Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details Gas Supply Pump (See Fig. No s. 12/13) Storage cylinder HWS flow 8 Hot Outlets Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Cold Supply NB. Size mains pressure group to suit building design flow rate 6 Tank thermostat kit (part no. C927) set to 65ºC Dynamic Pressure NG 20 mbar Propane 37 mbar

Fig No.11 Andrews WH and WHX Multiple Water Heater Installation with ST Range Storage Cylinder, Quick Connect Cord Kit and Secondary Return Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details Remote controller set to 70ºC 1. Stop cock 2. Strainer 3. Pressure reducing valve 4. Non return valve 5. Expansion vessel 6. Expansion valve + tundish 7. Andrews bronze pump c/w ball valve unions (part no. B249) 8. Combined temperature and pressure relief valve + tundish 1 2 3 4 Quick connect cord kit (part no. B286) 5 7 Gas Supply Pump (See Fig. No s. 12/13) 8 Storage cylinder HWS flow Hot Outlets Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Cold Supply NB. Size mains pressure group to suit building design flow rate 6 Bronze secondary pump Tank thermostat kit (part no. C927) set to 65ºC Dynamic Pressure NG 20 mbar Propane 37 mbar

Fig No.12 Andrews WH and WHX Multiple Water Heater Installation with ST Range Storage Cylinder and Secondary Return Please refer to the FASTflo Specification Sheet and Flue Selection Guide for Flue Kit and termination details Remote controller kit (part no B285)* *An Electronic System Controller Kit can be used as an alternative when manifolding up to six units. (see Fig. No s 6 and 8) 1. Stop cock 2. Strainer 3. Pressure reducing valve 4. Non return valve 5. Expansion vessel 6. Expansion valve + tundish 7. Andrews bronze pump c/w ball valve unions (part no. B249) 8. Combined temperature and pressure relief valve + tundish 1 2 3 4 5 6 7 Pump (See Fig. No s. 12/13) Gas Supply 8 Storage Cylinder HWS flow Hot Outlets When using multiple units in conjunction with a storage vessel the full output of all heaters is required to provide maximum recovery volume. In this case the primary pump must be sized to give 8 litres/min for each heater. See Fig No s. 12 and 13. Gas rate for NG units WH42-5.1 m 3 /hr WH56, WHX56-6.5 m 3 /hr Cold Supply NB. Size mains pressure group to suit building design flow rate 6 Bronze secondary pump Tank thermostat kit (part no. C927) set to 65ºC 4 Gas rate for Propane units LWH42-1.9 m 3 /hr LWH56, LWHX56-2.5 m 3 /hr Dynamic Pressure NG 20 mbar Propane 37 mbar

Fig No.13 Flow Rate Head Loss and Pump Sizing The WH and WHX units will operate within a water inlet pressure range from 1.0 bar to 10.0 bar. When a pump is used with a storagae system or for secondary return circulation only bronze or stainless steel pumps must be used. The pump must be sized to give a minimum flow rate of 8 L/min through each heater. The head loss through the FASTflo range of products is due to the friction generated when the water flows through the heat exchanger and associated components. Head Loss (bar) 2.5 2 1.5 1 0.5 0 0 5 10 15 20 25 30 Water Flow (litres/minute) Pump Selection using multiple heaters (pump required for first unit only) Number of units Flow rate required Approximate head Speed setting 1 8 l/min - 0.13 l/sec 50 kpa 2 Pump selection using multiple heaters (flow through all units) 2 16 l/min - 0.27 l/sec 50 kpa 2 3 24 l/min - 0.40 l/sec 60 kpa 3 4 32 l/min - 0.53 l/sec 60 kpa 3 5 48 l/min - 0.67 l/sec 60 kpa 3 6 48 l/min - 0.80 l/sec 60 kpa 3 A suitable 3 speed bronze pump kit with ball valve unions to 28mm cu. can be supplied by Andrews, part no.b249 (see Fig No. 14)

Fig No.14 Pump Curves for Andrews 3 Speed Bronze Circulating Pump. Part No.B249 H (m) 8 7 6 5 4 3 2 1 SPEED 1 SPEED 2 SPEED 3 0 0 0.2 P1 (W) 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Q(1/s) 200 160 120 80 40 0

Fig No.15 Dimensions WH42/LWH42/WH56 and LWH56

Fig No.16 Dimensions WHX56 and LWHX56

Fig No.17 WH42, LWH42, WH56 and LWH56 Pre-assembled dual manifold unit dimensions

Fig No.18 WH42, LWH42, WH56 and LWH56 Pre-assembled triple manifold unit dimensions

Fig No.19 WHX56 and LWHX56 Pre-assembled dual manifold unit dimensions Note: Pipework covers are optional

Fig No.20 WHX56 and LWHX56 Pre-assembled triple manifold unit dimensions Note: Pipework covers are optional

October 2010 Baxi Commercial Division Wood Lane, Erdington, Birmingham B24 9QP Email: andrews@baxigroup.com www.andrewswaterheaters.co.uk Sales: 0845 070 1056 Technical: 0845 070 1057