MANDATORY MEASURES DAYLIGHTING. (Reference: Sub-Chapter 4, Section 130)

Similar documents
MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

Code Review TITLE PRESENTED BY POURIA NIKNAM

WSA120: New Energy Codes and Lighting Controls

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

TITLE 24 ICONOGRAPHY. Iconography System

What s New in the 2013 Energy Code? Changes to mandatory Title 24 lighting requirements

Are LED s ready for Prime Time?

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

California Title Design Guide for Smart Lighting Control and Energy Solutions

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Here we see the list of auto shutoff controls we will cover in the next few slides

ASHRAE October 18, 2013

Decoding 2016 Title 24, Part 6

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

C A L I F O R N I A E N E R G Y C O M M I S S I O N

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Oregon Non-Residential Building Energy Code

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

Lighting Application Guide for K-12 Classrooms

visual environment technologies etcconnect.com

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Daylighting Control Design and Application Guide

PRESCRIPTIVE APPROACH

A Guide for Applicants and Lighting Designers

miniz Quick Start Guide

Wireless Lighting Control Made Easy

Advanced Lighting For Office

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

High Performance Lighting. Terry Egnor Senior Consultant NBI

Cosmetology Lab Redesign

WELCOME TITLE 24 REQUIREMENTS & THE MAXLITE PRODUCT LINE. 9/5/14 Webinar Presented by: Greg Murphy

Hubbell Controls Application Guide to CA Title 24 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

FR-A180 FR-A360. Occupancy detector. Use

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

Codes and Controls Commercial Building Energy Code Requirements for Light Control. Michael Jouaneh, CEM, LEED AP September 20, 2012

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

2016 Electrical Supplemental Plan Review List

ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*

A Guide to the Commercial Building Tax Deduction. Effective: January 1, 2006 to December 31, 2008 HL /07

Application Guide to CA Title 24

COMcheck Software Version Interior Lighting Compliance Certificate

The Children s storytelling area

Sensors Explained AUTOMATION

Eligible Prescriptive Measures List:

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Lecture 8 OPENINGS &ORGANIZATION OF FORM AND SPACE

New LED Product Offerings

Linergy II. England and Wales Cricket Board, Truro Linergy

Advances in Non-Residential Lighting Technologies

Lighting Summary - Interior

Lighting Controls An Introduction and Review

Buidling 661 Annual Daylight Performance Modeling Studies

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Code Compliance Commercial Application Guide

Lighting Design Criteria: Codes and Standards

2017 Michigan Energy Code Changes Electrical Provisions-Commercial Michigan Energy Code Training and Implementation Program

Lighting Existing Conditions and Design Criteria Report

Erin McCauley The Gateway Building

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

Fixture control made simple

We also offer Framed Mirrors. These are framed with a powder-coated aluminium frame that comes in a variety of colours.

Hospitality Title Solutions

Office Title Solutions

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Education Title Solutions

August 15, 2013 Page 1 of 19

Residential New Home Construction Checklist

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

2015 IECC. Design Guide for Smart Lighting Control and Energy Solutions

Healthcare Title Solutions

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

The Bahen Centre for Information Technology. Meeting Room Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

Project Name. Date. Cat. Number. Type

Indoor Controls. SpaceWise SWZG2. Wireless technology

Ventilation for New Low-Rise Residential Buildings July 20, 2015

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

Technical Report I. jack risser lighting/electrical. s. good the nerman museum. overland park, kansas sept 16 th, 2013.

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Lobby Lighting Redesign

Building Regulations Approved Document F1 Means of Ventilation April 2006

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

LPCMPIRM65 & LPCMPIRDSI65

2018 Business Lighting Rebate Application

Project Name. Date. Cat. Number. Type

Main Lobby Area (North Vestibule thru South Vestibule):

NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ECA EXPLAINED HELEN LOOMES 2013/2014 SLL MASTERCLASS

2005 Title 24 Outdoor Lighting Regulations Overview. 77 slides

Manufacturing. Industrial Lighting & Controls Solutions

Transcription:

MANDATORY MEASURES DAYLIGHTING (Reference: Sub-Chapter 4, Section 130)

MINIMUM DAYLIGHTING FOR LARGE SPACES Large enclosed spaces, such as large retail warehouses, are required to have a minimum amount of daylight available. The minimum requirements apply to both conditioned and unconditioned spaces that are: 1. In Climate Zones 2 15 2. Have a floor area greater than 5,000 square feet 3. Have a ceiling height greater than 15 square feet 4. Have a general lighting system with a power density greater than 0.5 watts per square foot Buildings that meet the above criteria must have: At least 75% of the floor space of the building in a primary sidelit zone or skylit zone No more than 5% of the roof area may contain skylights Section 140.3 (c) 10/7/2013 SLIDE 141 SECTION 7 DAYLIGHTING CONTROLS

DAYLIGHT ZONES Regions within a building that are close enough to a source of daylight that daylight harvesting is possible are considered within a daylight zone. Skylit Zone: An area illuminated by one or more skylights Primary Sidelit Zone: A daylit area directly adjacent to one or more windows Secondary Sidelit Zone: An area not directly adjacent to a window that still receives some daylight through its proximity to the window All daylight zones must be marked on the building floor plans. 10/7/2013 SLIDE 142 SECTION 7 DAYLIGHTING CONTROLS

SKYLIT ZONE When determining the skylit zone, the shape of the zone is the same as the geometric shape of the opening of the skylight. For example, a rectangular skylight creates a rectangular daylight zone, and a circular skylight creates a circular zone. Calculation Steps: 1. Multiply the average ceiling height of the building by 0.7 2. Add this value in all directions around the skylight (starting at the edge of the rough opening) 3. Subtract any area in which a permanent obstruction would block daylight (taller than half the distance from the floor to the bottom of the skylight) 10/7/2013 SLIDE 143 SECTION 7 DAYLIGHTING CONTROLS

CALCULATING THE SKYLIT ZONE 10/7/2013 SLIDE 144 SECTION 7 DAYLIGHTING CONTROLS

PRIMARY SIDELIT ZONE The primary sidelit zone is a daylit area directly adjacent to one or more windows. Calculation Steps 1. Determine the window head height for each window 2. The length of the zone is one window head height into the area adjacent to the window 3. The width of the zone is the width of the window plus half the window head height one ach side of the window 4. Subtract any area on a plan that is blocked by a permanent obstruction that is six feet or taller. Window Head Height = Vertical distance from the finish floor level to the top of a window. 10/7/2013 SLIDE 145 SECTION 7 DAYLIGHTING CONTROLS

SECONDARY SIDELIT ZONE Secondary sidelit zones are extensions of primary sidelit zones. They represent areas where daylight is present, but may provide less illumination because of their distance from windows. Calculation Steps 1. Add one additional window head height to the same dimensions determined for the primary sidelit zone 2. Subtract any area that is blocked by a permanent obstruction that is six feet or taller 10/7/2013 SLIDE 146 SECTION 7 DAYLIGHTING CONTROLS

CALCULATING THE PRIMARY SIDELIT ZONE (SIDE VIEW) 10/7/2013 SLIDE 147 SECTION 7 DAYLIGHTING CONTROLS

PRESCRIPTIVE COMPLIANCE REQUIREMENT FOR SECONDARY SIDELIT ZONES When using the prescriptive compliance method, the automatic daylighting controls requirements for primary sidelit zones also apply to general lighting luminaires that are at least 50% in a secondary sidelit zone. Section 140.6 (d) 10/7/2013 SLIDE 148 SECTION 7 DAYLIGHTING CONTROLS

ACTIVITY: CALCULATING DAYLIT ZONES Calculate and draw the Primary and Secondary Sidelit Zones on the convenience store plan in your workbook. Assume the following: Window Head Height: 10 ft. Aisle Height: 4 ft. 10/7/2013 SLIDE 149 SECTION 7 DAYLIGHTING CONTROLS

10 ft. (1 WHH) 10 ft. (1 WHH) 10 ft. (1 WHH) 10 ft. (1 WHH)