environmental chambers for Battery testing

Similar documents
environmental chambers for Battery testing

EZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology

Environmental.

Remote Conditioners. RC-Series. ZPRC Series

Altitude Chambers.

Remote Conditioners. RC-Series. ZPRC Series


HALT & HASS Systems.

Stability Chambers & Rooms

halt & hass systems

Mitigating Risk of Battery Testing in Environmental Chambers. Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero

Z-Plus. Temperature/Humidity Chambers.

Benchtop & Compact Test Chambers

Z-Plus Series Temperature/Humidity

Z-Plus Temperature/Humidity Chambers

Industrial Freezers &

Helping Make Safe & Reliable Products Because people count on your products everyday

Because People Count On Your Products Everyday, You Can Count On Us

Selecting an Environmental Test Chamber

Cold chain monitoring technologies. Facility monitoring

A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133

Wireless DC Voltage Detector

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Wireless 0-5 Volt Meter Sensor

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

Wireless Duct Temperature Sensor

Walk in Freezer. Comfortable work environment

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

Compact Ultra Low Temperature Chamber

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Battery Abuse Fire Testing to SAE J2464. Rich Byczek, Intertek

Freezers. Laboratory & Plasma. i.series Horizon Series

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Refrigerated Incubator Model and Operating Instructions

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

CTS Your Partner for Customised Technical Solutions

The Leading Enterprise Internet of Things Solution. Wireless Open / Closed Sensors OPEN / CLOSED. Features of Monnit ALTA Sensors. General Description

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

AUTOMATIC FIRE & EXPLOSION SUPPRESSION SYSTEM.

Walk-Ins & Refrigeration Systems

Thermostats. Innovative solutions for the toughest requirements

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Our Extended Personal Electronic Dosimeter (PED) Family

EasyLog Data Logger Series

Safe Operation Manual. Honeywell IQ Force Gas Detector

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

USER MANUAL USB Multi-Function Datalogger Model RHT35

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Full Scale Battery Tests

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

Auto Technology Company Cyclic Corrosion Test Chamber

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

The Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

WOOD CHIP HEATING HPK-RA

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Dependable Solutions for Gas Detection

WOOD CHIP HEATING HPK-RA

Wireless Thermocouple Sensor

Smoke detection in hazardous areas:

Multi-Lab REFRIGERATORS Frigidere medicale

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

EasyLog Data Logger Series

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Medical Refrigerators

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Batt-Safe Battery String Monitoring System

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

DIRECTIVE NO: D-B

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

HV-50 HVOF Thermal Spray System

VWR Laboratory Refrigerators and Freezers

MGC Dock User s Manual

Chemistry diaphragm pumps

Laboratory Furnaces. Tube Furnaces. Box Furnaces. Control Systems. Furnace Accessories. Temperatures up to 1800 C

Dräger X-am 7000 Multi-Gas Detection

Li-ion Tamer Improved monitoring for lithium-ion battery health & safety. SUPDET ESS Design Challenge November 30 th, 2018

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

IMR IX176 Portable Gas Detector User Manual

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Products for Secondary Battery Market

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

STRIKE GUARD DELIVERS:

IMR EX610. Portable Gas Detector. Operation Manual

LogTag TICT - is0 Tag

MGC Dock User s Manual

Benchtop Test Chambers Temperature and Humidity

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Transcription:

environmental chambers for Battery testing www.cszindustrial.com

Battery Testing SOlutions Cincinnati Sub-Zero (CSZ) is a leading provider of environmental test chambers with over 76 years of industry experience in designing and manufacturing temperaturehumidity controlled products. We supply a variety of test chambers for testing batteries of any size with extensive experience in chambers designed for testing NIMH, lead acid and lithium ion batteries from small battery cells to large battery packs. Battery testing chambers are supplied to a variety of industries including, automotive, computer, telecommunications, defense, and alternative energy markets. With the goal of reducing automobile emissions and the push toward electric hybrid vehicles, the need for lithium ion battery testing is even more critical. Our proven experience provides the most cost-effective solutions. Each test chamber is built according to specific test requirements and may be interfaced with battery cyclers, control & monitoring data acquisitions systems and other test equipment for a complete integrated test solution. CSZ reach-in and walk-in chambers featured at GM Battery Test Laboratory. 2

Environmental chambers are available from small benchtop chambers for testing small battery cells to large walk-in chambers for testing large battery packs. Temperatures range from -70 C to +190 C (-94 F to + 375 F) with an optional humidity range as low as 10% to 95%. Sizes are available from small benchtop units to large walk-in rooms. Products High/Low Temperature Cycling Chambers Humidity Chambers Thermal Shock Chambers AGREE Temperature/Vibration Chambers Altitude Chambers Explosion Proof Chambers Temperature Ranges Single Stage: -34 C to +190 C (-30 F to +375 F) Tundra : -45 C to +190 C (-49 F to +375 F) Tundra II: -50 C to +190 C (-58 F to +375 F) Cascade: -70 C to +190 C (-94 F to +375 F) Exclusive Tundra Refrigeration System The utilities involved with battery testing facilities and electric consumption add to the operating cost of each piece of equipment, a consideration to the bottom line and an important aspect in selecting test equipment. The compressors on an environmental chamber are often a large portion of the electrical load. CSZ offers the patented Tundra system, which utilizes a single compressor to get to -45 C (-49 F), and the Tundra II system which also uses a single compressor and provides the ability to test as low as -50 C (-58 F). By using only one compressor for cold temperature testing at these low temperatures, significant savings can be realized in both operating and maintenance costs. AGREE Temperature, Humidity Chamber interfaced with Vibration Shaker Table 800.989.7373 513.772.8810 www.cszindustrial.com 3

Features and Options Safety Features and Options We provide safety features for reliability and abuse testing of batteries. Each environmental chamber is designed with safety in mind. Safety features may be incorporated into CSZ test chambers and tailored to the various hazard levels (0-6) to help mitigate potential risks. Battery Testing Risks Chemical reactions Thermal charges & thermal runaways Reactions to overcharge Reactions to fast charge Reactions to damage Rupture Fire & flame from ignition of flammable gas/liquid Explosion Failure Modes Cracks in membrane separating anode and cathode Overheating Over charging Under charging 4 Reference: FreedomCAR: Electrical Energy Storage System Abuse Test Manual for Electric and Hybrid Vehicle Applications SAND 2005-2123

Hazard Severity Level Description Classification Criteria and Effect 0 No Effect No effect. No loss of functionality 1 Passive Protection No defect; no leakage; no venting, fire, or flame; no rupture; no explosion; no exothermic reaction or thermal runaway. Cell reversibly damaged. Repair of protection device needed. Activated 2 Defect/Damage No leakage; no venting, fire, or flame; no rupture; no explosion; no exothermic reaction or thermal runaway. Cell irreversibly damaged. Repair needed. 3 Minor Leakage No venting, fire, or flame*; no rupture; no explosion. Weight loss <50% of electrolyte weight (electrolyte = solvent + salt). 4 Major Leakage/ Venting No fire or flame; no rupture; no explosion. Weight loss 50% of electrolyte weight (electrolyte = solvent + salt). 5 Fire or Flame No rupture; no explosion (i.e., no flying parts). 6 Rupture No explosion, but flying parts of the active mass. 7 Explosion Explosion (i.e., disintegration of the cell). * The presence of flame requires the presence of an ignition source in combination with fuel and oxidizer in concentrations that will support combustion. A fire or flame will not be observed if any of these elements are absent. For this reason, we recommend that a spark source be used during tests that are likely to result in venting of cell(s). We believe that credible abuse environments would likely include a spark source. Thus, if a spark source were added to the test configuration and the gas or liquid expelled from the cell was flammable, the test article would likely progress from level 3 or level 4 to level 5. GM Corporation 800.989.7373 513.772.8810 www.cszindustrial.com 5

Features and Options Safety Features and Options External Lights - externally mounted lights eliminates potential spark source Temperature Limited Sheath Heaters - Standard ni-chrome wire heaters can reach temperatures of +540 C (+1000 F). Temperature is set below ignition temp. of gases. Includes Intrinsically SafeBarriers (to prevent T/C sparking) Intrinsically Safe Barriers - Prevents the potential of high voltage pulses Protective Enclosure/Structure - External structure that would contain any fire or explosion Non Sparking Fan Blades or Blower Wheels - Prevents sparking/explosion Reinforced Chamber Floor - To support weight of heavy product and extreme temperature LN2 Test Article Surface Cooling - Used to cool cells or packs if they overheat - may help prevent thermal runaway Fresh Air Exchange System - Aids in removing all gases from inside the chamber prior to opening the door Safety Door Interlock - Prevents entry either during tests or after an event Gas Monitors - O2, H2, CO, etc - Can be interlocked to controller to shut down chambers Custom Pressure Relief Vent - Protects chamber from a sudden release of high pressure gas 6

Fire Suppression Systems Inert Atmosphere Uses N2 or CO2 to eliminateoxygen - does not prevent thermal runaway but can help contain Pressure Relief Port A 12 X 12 square port in the ceiling of the chamber with a plug on slide rails. GN2 Purge Helps flush out outgassing from product under test 800.989.7373 513.772.8810 www.cszindustrial.com 7

Features and Options Battery Cell Testing 8

Battery Test Specifications for Environmental Testing Below are common battery testing standards that require the environmental testing such as temperature cycling, humidity, altitude and vibration. Test Specification IEC 62660-2 SAE J2464 SAE J2929 IEC 60086-4 UL 1642 UL 2580 UN/DOT 38.3 IEC 61960 IEC 62133 IEC 62281 RTCA DO-311 UL 2054 Description Reliability & Abuse Testing for Lithium Ion Cells in Electric Vehicles EV & HEV Rechargeable Energy Storage System Safety & Abuse Testing Safety Standard for Electric and Hybrid Vehicle Propulsion Battery Systems Utilizing Lithium-based Rechargeable Cells Primary Batteries, Part 4: Safety of Lithium Batteries Standard for Lithium Batteries Batteries for use in Electric Vehicles UN Lithium Battery Testing Requirements Secondary Lithium Cells and Batteries for portable applications Secondary Cells and Batteries Containing Alkaline or Other Non-acid Electrolytes Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made from them, for Use in Portable Applications Safety of Primary and Secondary Lithium Cells and Batteries during Transport Minimum Operational Performance Standards for Rechargeable Lithium Battery Systems Household and Commercial Batteries 800.989.7373 513.772.8810 www.cszindustrial.com 9

EZT-570S Controller The Next Generation Controller with Smartphone Technology Save valuable time with the ease of use of the EZT-570S featuring fewer steps to accomplish your daily testing needs while incorporating simplified operation and programming to test faster. All features are built into the controller interface so no additional software or internet is required for access to all the features the controller has to offer. Manually control, run or stop a profile directly from the home screen and view a snap shot of current activity like actual/setpoint values, alarm, datalogging, profile, security, IP address information and more. Communications & Connectivity Monitor and/or Control the chamber remotely for anytime, anywhere access from any device (PC, smarphone or tablet) using LAN/VNC. Alarm notification system sends email and/or text phone messages in the event of a test chamber alarm, saving valuable tests while reducing downtime. Email built-in to send data, alarm, audit trail files directly from controller. Also create and send new emails. Profiling Profiling includes up to 99 steps and 1000 cycles. Program ramp steps entering time or C/min. Programs may be written using product control function. Easily review profile using trend chart or review list of steps before running profile. Profile status view displays current step, estimated start/stop date and time and more. Profiles may be transferred to different chambers via USB or optional EZ-View software. Automated delay profile start. Data Logging Configurable log interval, data file length, filename, operator entered batch & lot information as well as an unlimited number of operator notes saved to the data file. Access data files directly from controller or PC. Easily download profiles, alarm files, audit trail files and data files using LAN (FTP, email) and/or USB in a compatible.csv file format for ease of use. Files may also be automatically backed up daily for hassle-free file management. 10

User Convenience & Flexibility Controller may be configured in any of one of 28 languages one setting up dates icons, menus and help screen. Selectable power failure/recovery options. Full system security allows up to 30 different users with four different levels of security. Audit trail files track changes in settings by each user. Import/export configuration settings to other controllers saving time. (Personalized to your use) Configure alarm setting and maintenance alerts. Graphing Technology Real-time trend display graph with adjustable time and min/max values. Up to eight configurable trend graphs with left & right axis Graph historical data files Zoom in/out graphs Enhanced Communications & Control Options Digital input option provides 8 inputs that can be configured for various control functions including starting, stopping and pausing a profile. Wait for function allows the user to pause a profile during a particular step of the profile until a specific digital input is turned on or off. Digital output customer event feature provides 15 programmable outputs. Each output can be configured to perform other operations including alarm or profile status indicators for more control over your testing. Optional refrigeration monitor package displays and data logs temperatures and refrigeration system compressor suction/discharge pressures. Condensation control option helps prevent condensation from collecting on the part by automatically managing the air dewpoint. Bar code option allows user to scan barcode to start profile and to add notes to current data file when datalogging. 800.989.7373 513.772.8810 www.cszindustrial.com 11

CSZ is committed to your satisfaction every step of the way. With the initial point of contact, through the process of fully understanding your unique needs and partnering to develop the right solution, through implementation and delivering outstanding post-sale support. CSZ is your one stop solution for Environmental Chambers Temperature Cycling Humidity Stability Cabinets & Rooms Thermal Shock Stress-Screening Altitude AGREE Vibration HALT/HASS Freezers Liquid Chillers Wind & Rain Sand & Dust Other Temperature Management Solutions Sizes range from benchtop to full walk-in/drive-in chambers. Services Refrigeration Retrofits Controller Upgrades Preventative Maintenance Calibration Services CSZ has two manufacturing facilities in Cincinnati, OH with world-wide sales and service. Testing Services CSZ Testing Services is an A2LA Accredited Test Laboratory utilizing the latest test technology. We are your one stop source for all of your environmental simulation testing needs. Our testing laboratory is here to help with your product qualification testing, overflow testing and /or third party product validation. Testing capabilities include Temperature, Humidity, and/or Vibration, Thermal Shock, Burn-in, Radiator Testing, Altitude, Vibration, HALT/HASS, Shock, Salt Spray, Cyclic Corrosion test, and Drop Testing. Serving you from two locations in Cincinnati, OH and Sterling Heights, MI. For more information please call CSZ Testing headquarters at 513-793-7774 or visit www.csztesting.com. 503.1 & 503.2 Cincinnati Sub-Zero 12011 Mosteller Road Cincinnati, OH 45241 (p) 513-772-8810 (f) 513-772-9119 www.cszindustrial.com Cincinnati Sub-Zero Products, LLC 95027 11/17