Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Similar documents
Enclosed Scroll Air Compressor System SES 3-5 HP

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

SECTION AIR COMPRESSORS AND ACCESSORIES

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

SECTION AIR COMPRESSORS AND ACCESSORIES

Scroll Medical Air Compressor with Premium NFPA Control Panel

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Technology for the Better Future. Medical Air Compressor Systems

5. CONDENSATE PUMPS/UNITS

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Condensate Boiler Feed Water Make-Up

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

RTi Compressor Guide. Screw - Horizontal. Piston - Vertical Duplex - Horizontal. Screw - Vertical. Piston - Cube. Screw - Enclosed Elite.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

QR-25 QUINCY QR-25 SERIES RECIPROCATING AIR COMPRESSORS 1 25 HP

Specifications. General Safety Information. NOTE: Information that requires special attention.

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

FLANGE-MOUNT CENTRIFUGAL PUMPS

Refrigerated Air Dryers

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

SECTION STEAM CONDENSATE PUMPS

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Description. Specifications. Safety Guidelines. Unpacking. General Safety Information

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

(2) 325 tpd York Chlorine Liquefier Systems

RHP120 RHP300 Steam Boiler Series

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

SECTION AIR COOLED WATER CHILLERS

Liebert CSU3000 Chiller

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

REFRIGERATED AIR DRYERS

SECTION STEAM CONDENSATE PUMPS

The Quincy QMB and QMT: A new approach to the modular advantage

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Lubricated Rotary Screw Air Compressors

Reciprocating Instrument Air System. Installation Operation and Maintenance Manual 5-20 Hp

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

C13-Series Engineering Guide

QUINCY QGS SERIES hp

SECTION CHILLERS

MODEL MW200 MODEL MW600 AIR DRYER

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MACH N-407 Heat Pump Air-Cooled Chiller

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Refrigerant Valves/Accessories

Quality Components as a basis for Quality Equipment

Global Series Screw Air Compressors Life source of industries

Air-Cooled Condensers

Air-Cooled Condensers

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

Compressed Air Dryers

Paragon. Induced Draft, Counter Flow Optional Accessories

TM Series. Induced Draft, Counter Flow Optional Accessories

HEATLESS DESICCANT AIR DRYERS

REFRIGERATED AIR DRYERS

DGH Series Global Air Treatment

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Deaerator. Specifications

SMALL AIR COOLED CONDENSERS

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

LOW PROFILE UNIT COOLER

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Direct Fired Heater Model AD Specification

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Global Series Screw Air Compressors Life source of industries HP

Wilo IL Vertical Split-Coupled Inline Pumps

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

MANUFACTURED with high-quality components and innovative techniques. DESIGNED for economical, trouble-free performance and long-life reliability

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

201 Series Dryers Features and Benefits...3 Dimensions...4 How to Order...5 Product Specifications...5

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Condensate Drain Valves

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

JCseries EVAPORATIVE CONDENSER. engineering data

Dual Tower Heat Reactivated Desiccant Air Dryer

VertiCool Aurora Engineering Guide

Direct Gas-Fired Make-Up Air

Installation, Operation and Maintenance Instructions. Reciprocating Piston Medical Air Compressor System

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

MAC N-407 Air-Cooled Chiller

Air-Cooled Condensing Units with Bitzer Compressors

FX5 Series Explosion-Proof Electric Air Heaters

Transcription:

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the quality of the compressed air is critical (dryer option is required for the dry air application). AIR COMPRESSOR SYSTEM The package shall include one or two oil-less reciprocating air compressor/s and associated equipment, one ASME air receiver, and one optional magnetic starter/alternating control panel. The only field connections required will be system discharge, power connection at the control panel and dryer, and condensate drain connection. All interconnecting piping and wiring shall be included and operationally tested prior to shipment. A desiccant or refrigerant air dryer system is optional. OILLESS COMPRESSOR PUMP Each compressor shall be of the following design: belt driven, reciprocating type, single-stage (1-3 HP), or two-stage (5-15HP), single acting, air cooled, oil-less construction with absolutely no oil needed for operation. Pistons shall be manufactured of heat rejecting Composite Resin with PTFE rings. Aluminum pistons shall not be used. Compressor design shall also include stainless steel valves with PTFE coated aluminum die-cast valve plates, precision bore die-cast anodized aluminum cylinders, anodized inter-stage intercooler(s), ductile iron crankshaft with counterweight and oversized sealed ball bearings, and single piece connecting rods with sealed needle bearings. Compressors shall have a Dual Cooling System which includes a radial flow fan and flywheel fan, which are driven by the pump crankshaft. Each compressor shall be equipped with a check valve. Each compressor unit shall be capable of up to 145 psig continuous-duty operation. MOTORS Each compressor shall be belt driven by a 1750 RPM, ODP NEMA construction motor. Motors operating at speeds higher than 1750 RPM shall not be acceptable. OSHA approved belt guards shall be provided. Motor shall not operate in the service factor. Optional motors include TEFC. AIR RECEIVER The system shall include an ASME rated air receiver, rated for 200 PSI MAWP. The tank shall be equipped with a pressure gauge, safety relief valve, discharge shut-off valve, and manual tank drain. OPERATIONAL AIR-COOLED AFTERCOOLER (Required for unit with Desiccant Dryer) Beltguard mounted aftercooler is provided for each compressor and sized for an approach temperature of 15 degrees F. Units are constructed of copper tubing with metal headers. An optional moisture separator with an automatic drain valve is available for the beltguard aftercooler option. OPTIONAL DESICCANT AIR DRYER Twin tower, heatless, desiccant air dryer is provided with.01 micron pre-filter and 1 micron after filter. Dryer is tank mounted (simplex unit up to 3HP only) and sized to provide a pressure dew point to meet NFPA standards. Desiccant dryer controls are to be powered from a separate supply, not through compressor controls. OPTIONAL REFRIGERANT AIR DRYER The refrigerated air drying system shall be tank mounted with compressor, and shall provide air at a 35-38 degree F pressure dew point. The refrigerated compressed air dryer is non-cycling, direct expansion, using R-134a refrigerant (CFC free). A constant pressure expansion valve is provided to maintain a 35-38 degree F evaporator temperature. The dryer is self-regulating for large load swings, and includes a 3-micron filter/separator with automatic condensate drain. Refrigerated dryers are to be powered from a separate supply, not through the compressor controls. Option also includes a.01 micron after filter, a pressure regulator, an installed aircooled aftercooler for each pump and an installed automatic solenoid timer drain. AVAILABLE OPTIONS Motor options o TEFC Air Receiver options o 30, 60, 80, 120 gal. (unit specific) o Electric drain o No loss drain o FDA approved tank lining Control Panel options o NEMA 4/12 o High temperature Inlet filter options o Threaded for remote inlet Desiccant or refrigerant air dryer Motor slide base (per motor) 50 Hz operation Optional drain valves include: 1) 115V No-loss type automatic tank drain, 2) 115V automatic solenoid timer drain, or 3) automatic float style drain. OPTIONAL CONTROL PANEL SIMPLEX The system shall include a UL listed magnetic starter in a NEMA 1 enclosure with 3-leg overload protection, hour meter, and overload reset button. A NEMA 1 pressure switch shall control the start/stop operation of the compressor and shall operate in the range of 90-120 psig. DUPLEX The system shall include a UL listed magnetic starter in a NEMA 1 enclosure with full voltage motor starter with overload protection, an alternator, 120 volt transformer, fused primary and secondary circuits, elapsed time indicators, and maintenance switch (left/auto/right). Control panels shall be UL 508A listed and labeled. A NEMA 1 pressure switch shall control the start/stop operation of the compressor and shall operate in the range of 80-120 psig. SR4489 08/12

DIMENSIONS OTS1101 48" 21" 39" 1/2" OTS1102 56" 22" 43" 1/2" OTS0101 48" 21" 39" 1/2" OTS0102 56" 22" 43" 1/2" OTS1151 48" 21" 39" 1/2" OTS1152 56" 22" 43" 1/2" OTS0151 48" 21" 39" 1/2" OTS0152 56" 22" 43" 1/2" OTS1202 56" 24" 45" 1/2" OTS0202 56" 24" 45" 1/2" 1-2 HP Rev. 10/12/12 Tank SYSTEM F.L.A. SYSTEM SCFM @ Max. MODEL 3 HP 1 Phase (Gal.) 100 PSIG PSIG BTU/HR Level 115V 208V 230V 460V (LBS) 2 OTS110 1 1 30/60 3.0 145 2,545 71 13.4 *7.4 6.7-231/312 OTS010 1 3 30/60 3.0 145 2,545 71 - *4.1 3.6 1.8 231/312 OTS115 1.5 1 30/60 4.2 145 3,818 71 18 *9.5 9-230/327 OTS015 1.5 3 30/60 4.2 145 3,818 71 - *4.5 4.4 2.2 230/317 OTS1202 2 1 60 7.2 145 5,090 71 24 *12.6 12-350 OTS0202 2 3 60 7.2 145 5,090 71 - *5.95 5.8 2.9 343 Notes: 1 - Actual BHP is less than rated name plate. Contact Powerex for BHP rating. 2 - The first weight listed reflects the unit with a 30 gal. tank and the second reflects a unit with a 60 gal. tank. 3 - OTS 1 HP and 1.5 HP models are available with either a 30 or 60 gal. tank. Please add -1 at the end of the model number to indicate a 30 gal. tank or a -2 at the end of the model number to indicate the 60 gal. tank. *System is usable at 208 volts, but should not be used at any value below that voltage. SR4490 10/12

DIMENSIONS OTS1303 70" 24" 46" 1/2" OTS0303 70" 24" 46" 1/2" OTS1513 71" 26" 49" 3/4" OTS1514 78" 26" 54" 3/4" OTS0503 71" 26" 50" 3/4" OTS0504 78" 27" 54" 3/4" OTS0754 77" 31" 54" 3/4" OTS1004 77" 31" 54" 3/4" OTS1504 77" 31" 54" 3/4" 3-15 HP Electrical lpanel Opening Top View 24 Minimum Clearance for ease of Maintenance Tank SCFM SYSTEM SYSTEM F.L.A. Size @ 100 Max. MODEL HP Phase (Gal.) PSIG PSIG BTU/HR Level 208V 230V 460V (LBS) OTS1303 3 1 80 10.1 145 7,635 71 *16.8 16-485 OTS0303 3 3 80 10.1 145 7,635 71 8.98 8.12 4.06 479 OTS1513 5 1 80 18.2 145 12,725 75 24 23-550 OTS1514 5 1 120 18.2 145 12,725 75 24 23-716 OTS0503 5 3 80 18.2 145 12,725 75 14.2 12.8 6.41 536 OTS0504 5 3 120 18.2 145 12,725 75 14.2 12.8 6.41 702 OTS0754 7.5 3 120 28.4 145 19,088 76 19.97 18.1 9.03 765 OTS1004 10 3 120 35.4 145 25,450 76 27 24.4 12.2 790 OTS1504 15 3 120 45.2 145 38,175 79 44.1 37.2 18.6 910 *System is usable at 208 volts, but should not be used at any value below that voltage. SR4491 07/12

Oil-less Tankmount Duplex 1-2 HP DIMENSIONS OTD1101 47" 24" 39" 1/2" OTD0101 47" 24" 39" 1/2" OTD1103 70" 25" 44" 1/2" OTD0103 70" 25" 44" 1/2" OTD1153 70" 25" 44" 1/2" OTD0153 70" 25" 44" 1/2" OTD1203 70" 27" 46" 1/2" OTD0203 70" 27" 46" 1/2" Oil-less less Tankmount Duplex Tank SCFM SYSTEM F.L.A. Size @ 100 Max. MODEL HP 1 Phase (Gal.) PSIG PSIG BTU/HR Level 115V 208V 230V 460V SYSTEM (LBS.) OTD1101 1 (2) 1 30 6.0 145 5,090 74 26.8 *15.3 13.8-272 OTD0101 1 (2) 3 30 6.0 145 5,090 74 - *8.7 7.6 3.8 270 OTD1103 1 (2) 1 80 6.0 145 5,090 74 26.8 *15.3 13.8-432 OTD0103 1 (2) 3 80 6.0 145 5,090 74 - *8.7 7.6 3.8 435 OTD1153 1.5 (2) 1 80 8.4 145 7,636 74 36 *19.5 18.4-439 OTD0153 1.5 (2) 3 80 8.4 145 7,636 74 - *9.5 9.2 4.6 435 OTD1203 2 (2) 1 80 14.4 145 10,180 74 *25.7 24.4-504 OTD0203 2 (2) 3 80 14.4 145 10,180 74 - *12.4 12 6 500 *System is usable at 208 volts, but should not be used at any valve below that voltage. SR4492 07/12

SR4493 07/12 OTD1303 70" 27" 46" 1/2" OTD0303 70" 27" 46" 1/2" OTD1304 77" 28" 50" 1/2" OTD0304 77" 28" 50" 1/2" OTD1514 78" 30" 55" 3/4" OTD0504 78" 30" 55" 3/4" Oil-less Tankmount Duplex 3-5 HP Oil-less Tankmount Duplex Tank Max. BTU/HR SYSTEM F.L.A. SYSTEM Size SCFM @ MODEL HP Phase (Gal.) 100 PSIG PSIG (total) Level 208V 230V 460V (LBS.) OTD1303 3 (2) 1 80 20.2 145 15,270 74 *34.1 32.4-658 OTD0303 3 (2) 3 80 20.2 145 15,270 74 18.4 16.7 8.3 650 OTD1304 3 (2) 1 120 20.2 145 15,270 74 *34.1 32.4-788 OTD0304 3 (2) 3 120 20.2 145 15,270 74 18.4 16.7 8.3 780 OTD1514 5 (2) 1 120 36.4 145 25,450 78 *48.5 46.4-941 OTD0504 5 (2) 3 120 36.4 145 25,450 78 28.9 26 13 930 *System is usable at 208 volts, but should not be used at any value below that voltage.

Oil-less Tankmount Duplex 7.5-15 HP DIMENSIONS OTD0756 93" 52" 65" 1" OTD1006 93" 52" 65" 1" OTD1506 93" 52" 65" 1" Oil-less Tankmount Duplex BTU/H TANK SYSTEM F.L.A. SCFM @ R SYSTEM MODEL HP Phase 100 PSIG SIZE (Gal.) (total) LEVEL 208V 230V 460V (LBS.) OTD0756 7.5(2) 3 56.8 240 38,176 79 20.5 36.63 18.3 1,430 OTD1006 10 (2) 3 70.8 240 50,900 79 54.6 49.23 24.6 1,510 OTD1506 15 (2) 3 90.4 240 76,350 82 82.7 74.83 37.4 1,620 SR4494 07/12