WBGT Heat Stress Meter

Similar documents

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

I/R Thermometer Gun 12:1

Pocket Moisture Meter Instruction Manual

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

VALTRONICS IAQ Monitor

Wireless Color Weather Station

Humidity Monitor model 01080

USER GUIDE Heat Index Psychrometer

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Thermometer with Wired Sensor

Forehead Infrared Thermometer

Ambient Weather WS-09 8-Channel Wireless Refrigerator/Freezer Thermometer User Manual

Thermometer model 02059

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Thermometer with Probe model 00891A

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

USER MANUAL Digital CO Monitor Model CO30

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Operating Instructions

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Microtherm Heat Stress WBGT

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Model: Touch-RF. 1 Wireless Series

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

USER MANUAL SFA2200 PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN IT FOR FUTURE REFERENCE

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Meat Thermometer with Wireless Display model 01185

User Manual. Humidity-Temperature Chart Recorder. Model RH520

5) Do not start or stop the unit by inserting or pulling out the power plug.

INDOOR WEATHER STATION

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

INSTALLATION AND OPERATION INSTRUCTIONS

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

Safe Operation Manual. Honeywell IQ Force Gas Detector

FEATURES AND SPECIFICATIONS

Smart Temp. Model

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

WIRELESS COLOR FORECAST STATION

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

Digital Refrigerator/Freezer Thermometer model 00986

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Ambient Weather WS-25 Wireless 8-Channel Floating Pool and Spa Thermometer with Indoor Temperature and Humidity User Manual

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Indoor/Outdoor Temperature Alert

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Water Tank Level Monitor

Model: C Instruction Manual DC: WIRELESS COLOR WEATHER STATION

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

Forehead Thermometer Instruction Manual

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Color Forecast Station. Table of Contents

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Digital Cooking Thermometer models / 00282

QD-ENG-68 Controller for Thermoelectric Thermal Management

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

IMR IX176 Portable Gas Detector User Manual

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Multi Line Laser Level Model: L203

Sunleaves Air Conditioner

WIRELESS COLOR WEATHER STATION


WARNING Important Safety Information

Owner s Manual. PIR-1 IR Learner

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Weather Station model 01120

WIRELESS COLOR FORECAST STATION

Refrigerator/Freezer Thermometer

WIRELESS COLOR WEATHER STATION

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

IMPORTANT. Display for 5-in-1 Weather Sensor model 06005RM/1010RX SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

High Resolution Display WIRELESS COLOR WEATHER STATION

Owner s Manual MODELS 8535, 8536 & 8537

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

WARNING Important Safety Information

Heat Stress WBGT Meter Model HT30

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Weather Station model /

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Model: Slimline-B. Battery Series

Transcription:

WBGT Heat Stress Meter 800036

WBGT Heat Stress Meter - 800036 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. HEAT STRESS REFERENCES: Refer to any of the following organizations for current and reliable data regarding heat stress threshold recommendations and guidelines. American Conference of Governmental Industrial Hygienists (www.acgih.org). American Industrial Hygiene Association (www.aiha.org). Canadian Centre for Occupational Health & Safety (www.ccohs.ca). Environmental Protection Agency (www.epa.gov). International Organization for Standardization (www.iso.org). National Climatic Data Center (www.ncdc.noaa.gov). 2

TABLE OF CONTENTS INTRODUCTION................ 4 FEATURES................... 5 MATERIAL SUPPLIED............. 5 UNIT DESCRIPTION.............. 6 KEYPAD.................... 7 LCD DISPLAY................. 8 FUNCTION SELECTIONS........... 9 Display Mode Selection........... 9 Heat Index Measurement......... 10 Non-Sleep Mode Selection......... 10 Alarm Threshold Selection......... 11 Data Analysis................ 12 BATTERY REPLACEMENT......... 13 TROUBLESHOOTING............ 13 ERROR CODES............... 14 SPECIFICATIONS.............. 15 WARRANTY................. 16 3

INTRODUCTION The Sper Scientific WBGT (Wet Bulb Globe Temperature) Heat Stress Meter (Model 800036) is light-weight, portable, and provides the most accurate determination of the heat stress index based on the cumulative effect of air temperature, air movement, relative humidity, and radiant heat. The WBGT Heat Stress Meter provides highly accurate readings with a typical response time of only 15 seconds. The WBGT Heat Stress Meter provides settings for both indoor and outdoor activities, and includes an audible alarm that is adjustable to your WBGT threshold. You can use the WBGT Heat Stress Meter almost anywhere to determine appropriate exposure levels to high temperatures and avoid heat exhaustion during athletic events, military exercises, and industrial activities. This WBGT Heat Stress Meter comes fully calibrated from our manufacturing facility, and should maintain it s calibration. 4

FEATURES Light-weight, Portable, and Accurate Provides accurate readings with a typical response time of only 15 seconds, and settings for both indoor/outdoor activities. Threshold Alarm An audible alarm that is adjustable to your WBGT threshold. Long-Life Battery Operation An expected battery life of more than 1000 hours (alkaline) and 250 hours (general purpose). Tripod Mountable A tripod screw mount for handsfree monitoring. Data Analysis USB port to connect with a PC for real-time data analysis. USB cable and data software sold separately. MATERIALS SUPPLIED Meter Batteries Instruction Manual 5

UNIT DESCRIPTION Black Ball Sensor Shell Sensor Sensor Cover Sensor Housing Screws (front and back of unit) Tripod Screw (back of unit) LCD Display Power/Set, Mode and Next Buttons USB Port (side of unit) Battery Compartment (back of unit) 6

KEY PAD Press the SET button to turn on/ off the unit and to enter the alarm setting mode. Press the NEXT button to select a digit in the alarm setting mode and to exit the setting mode when complete. Press the MODE button to change the display mode, to select the environment mode (IN/OUT), and to change the values when setting the alarm mode. + + Press the SET and MODE button simultaneously to select Non-Sleep mode and prevent the unit from turning off automatically. Press the NEXT and MODE button simultaneously to select between C & F temperature scales. 7

LCD DISPLAY WBGT - Wet Bulb Globe Temperature A composite temperature used to estimate the effect of temperature, humidity, wind chill, and solar radiation on humans. TG - Black Globe Temperature Temperature as measured by a black globe thermometer, which monitors the effects of direct solar radiation on an exposed surface. This temperature is analogous to what you feel when standing in the sun. TA - Air Temperature (Ta) The standard temperature as normally referenced in weather observations and forecasts. % - Relative Humidity The percentage of water vapor in the air. IN/OUT - Indoor/Outdoor Environment with or without direct sun exposure using the following equations: Indoor/Outdoor (No Sun): WBGT=0.7 WB + 0.3 TG Outdoor (Full Sun): WBGT=0.7 WB + 0.2 TG + 0.1 TA 8

C/F - Celsius/Fahrenheit Ambient temperature in either Celsius or Fahrenheit. - Low Battery Indicator The low battery icon indicates that you must replace the batteries. DP/REC/888 - Unused These indicators are reserved for use in future models. Please disregard. FUNCTION SELECTIONS This WBGT Heat Stress Meter comes fully calibrated from our manufacturing facility, and should maintain it s calibration. Display Mode Selection 1. Turn on the meter by pressing the SET button. The LCD display turns on and the meter enters measuring mode. 2. Short press the MODE button to select the RH, WBGT, TA, and TG modes, respectively. 3. Press and hold the MODE button, to select either IN (for indoor measurements) or OUT (for outdoor measurements). Each time you press and hold the MODE button, the LCD display switches between IN and OUT. 9

4. When reading temperature, press the MODE and NEXT buttons simultaneously to select between a Celsius (C ) and Fahrenheit (F ) temperature reading. Heat Index Measurement 1. Turn on the meter by pressing the SET button. The LCD display turns on and enters measuring mode. 2. Slide down the sensor protective cover. The LCD displays the value for the selected display mode within 15 seconds. 3. When you have completed your readings, slide the cover back up to its protective position and press the SET button to turn off the unit. Non-Sleep Mode Selection To save battery life, the WBGT Heat Stress Meter turns off automatically after 20 minutes of inactivity. To monitor the environment continuously for longer periods, you may override this feature: 1. With the meter turned off, press and hold the SET and MODE buttons simultaneously for 2 seconds. The meter displays П and enters Non-Sleep measurement mode. 10

2. When you have completed your readings, slide the cover back up to its protective position and press the SET button to turn off the unit. Non-Sleep mode is cancelled and the unit is reset to turn off automatically after 20 minutes. Alarm Threshold Selection The WBGT Heat Stress Meter features an audible alarm. You can adjust the alarm values as required within the range of 68.0 F to 99.0 F (20.0 C to 37.2 C). If the meter reaches the set alarm value, the unit emits an audible alarm (continuous beep at about 70dB) to let you know that your threshold has been exceeded. The alarm stops when the reading falls below the set threshold or when you turn off the meter. Be sure to set the unit to WBGT display mode. To set your alarm: 1. With the meter turned off, press and hold the SET button for 2 seconds. The LCD displays a temperature setting with the first digit flashing. 2. To change the value of the first flashing digit, press the MODE button repeatedly. 3. When you have selected the first value, press the NEXT button to select the second digit. 4. Press the MODE button repeatedly to change the value and repeat this step for the third digit. 11

5. When you have selected the desired WGBT alarm value, press and hold the NEXT button for 2 seconds to set the alarm value and enter measuring mode. Note If you have selected a setting that is out of range (lower than the current temperature), the LCD will display OUT under the temperature setting. Data Analysis WBGT Heat Stress Meter includes a USB port to connect your meter to a PC to store, analyze, and print data. USB Cable (840054) and the Data Acquisition Software (840052) are available as optional accessories. The software interface protocol is 9600 bps, 8 data bits, with no parity. The communication format transmits ASCII code every second while the WBGT Heat Stress Meter is turned on. Format: Wxxx.xC(F):Txxx.xC(F):Txxx.xC(F):Hxx.x%LRCCRLF The first value represents the WBGT; the second value represents TA; the third value represents TG; and the fourth represents the RH. 12

BATTERY REPLACEMENT 1. When the meter displays the low battery icon, press the SET button to turn the unit off. 2. Open the battery compartment on the back of the unit. 3. Remove the old batteries and replace them with 2 new AAA batteries. Replace the compartment cover. Battery life is greater than 1000 hours when using alkaline batteries (250 hours when using general purpose batteries). TROUBLE SHOOTING No Display: 1. Ensure that you have pressed the SET button for longer than >1 sec. 2. Ensure that the batteries are in good condition, have proper contact, and are in correct polarity. When in doubt, replace the batteries. (Refer to Battery Replacement. ) 13

Display Disappeared: 1. If the low battery indicator displayed before the display disappeared, replace the batteries. (Refer to Battery Replacement. ) 2. Disable the Automatic Power-Off function and place the unit in Non-Sleep mode. (Refer to Non-Sleep Mode Selection. ) ERROR CODES Error OUT E02 E03 E04 E011 E033 Description Low battery indicator Out-of-range indicator displayed during alarm threshold setting. The value is below the measuring range or the sensor is installed incorrectly. The value is above the measuring range. The original data is in error value error or the sensor is installed incorrectly. RH calibration error. Please contact our technical support at quality@sperscientific.com Fatal circuit error. Return the meter to the vendor for repair or replacement. 14

SPECIFICATIONS Range Res. Accuracy WBGT 0 to 50 C 32 to 122 F 0.1 C/F Air Temp (TA) Globe Temp (TG) Relative Humidity (RH) 0 to 80 C 32 to 176 F 0 to 100% RH 0.1% RH ±2ºC Indoor 3ºC Outdoor (-15 to 40ºC) Otherwise ±2.5 Indoor 3.5ºC Outdoor ±0.6ºC ±2ºC (15º to 35ºC) ±3% RH (10º to 90% RH) Otherwise ±5% RH 15

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for period of five (5) years from the date of purchase and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted, if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 8281 E. Evans Rd, Suite #103 Scottsdale, AZ 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperwarranty.com, within 10 days. 16 rev. 6/23/2017