Soltron Sea Shell XXS-35

Similar documents
Soltron XS-45 Flirt. Forever Tan 113 Freeland Lane Charlotte, NC

Ergoline Affinity 500

Ergoline Open Sun 1050

HydroMassage Electrical / Installation Preparation Requirements

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

SECTION : FIRE ALARM & DETECTION SYSTEMS

Installation Instructions

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Dear Concessionaire,

Cooktop Chimney Ventilation Hoods

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

Integrated Ventilation System

Installation Instructions Wall Ovens

MaxLite LED Round Pendant Highbay Series

DynaPack. Vertical Packaged Air Conditioner Featuring Gas Heat/Electric Cooling Designed to Serve Multi-Family Applications

FIRE ALARM: BY OTHERS, IF REQUIRED.

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

breeze easytm model # F100-1W

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

TECHNICAL SPECIFICATIONS

ELECTRIC FLAT PANEL FIREPLACE HEATER

PRO SERIES IMPORTANT SAFETY INFORMATION

e Bath Fan with Light User s Guide

Read these instructions carefully and completely. NOTE This appliance must be properly grounded.

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

SECTION COMMERCIAL-KITCHEN HOODS

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

FIRE ALARM: BY OTHERS, IF REQUIRED.

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Docking Drawer ELECTRICAL PLANNING GUIDE. for Docking Drawer and Style Drawer Installations

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

ESS. Environmental. Shield System. Instruction Manual. Environmental Shield System - ESS

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation Instructions

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

Installation Instructions

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Understanding Your Options: AFCI Protection and the 2015 CE Code

Electrisaver User and Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

MaxLite LED High Bay Fixtures

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Installation Instructions

Manifold Installation Controller MIC-180. Installation and Operation Instructions

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Installation Instructions

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY

2011 and 2014 National Electrical Code Changes Residential Only

NO VENTING REQUIRED 120V AC;

VENTILATION FAN WITH LIGHT AND HEATER

PART NO. COMBUSTION AIR CAP

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

INSTALLATION INSTRUCTIONS

12,000 BTU Evaporative Portable Air Conditioner

Packaged Terminal Air Conditioner (PTAC)

OPERATION & INSTALLATION MANUAL

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Ceiling Mount Air Purification System

Air Handler Installation Instructions Water Lines

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015

How To Size A Big Dipper Unit

PTAC 2017 Air Conditioner Collection

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Electrical Design Guidelines Table of Contents

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

Operator: Save these instructions for future use!

FerronTM. Instruction Manual A Kichler Decor ceiling fan

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Classic Mats Installation Manual

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

Transcription:

Soltron Sea Shell XXS-35 Forever Tan 113 Freeland Lane Charlotte, NC 28217 1-800-447-0040 For questions concerning this guide please contact Jeremy Welch: jeremyw@forevertan.net (704)971-4744

Electrical 6 pages This unit requires a 120/208 or 120/240 volts, single phase, 30 amp (4 wire) circuit Actual amp draw of 16 amps - These units have approximately 6 ft. of # 10 AWG wire (2 hots, 1 neutral and 1 ground) coming out of the back, in the center. The wire comes out through a ½ inch liquid-tight flex connector. These wires must be sleeved with flex and brought into a junction box. Do not shorten these wires, as this additional length is necessary to be able to pull out the bed for servicing. The wires should then be tied into a dedicated single phase, 30-amp (4 wire) circuit. Contact a licensed electrician. Check local code for disconnect requirements. All locations are given as if you were standing in front of the bed or unit. Junction box placement 43 from either side 6 up These measurements are where the conductors come out of the back of the unit and are given as if you are standing in front of the equipment. The junction boxes should be placed within 1 foot of this. These conductors must be sleeved with liquid tight flex. *** Important *** If this unit is attached to a three-phase service that has a high leg you must arrange the breaker in the panel so that this leg will not be supplied to this unit. The ballast for the low-pressure lamps is 120 volts as is the timer. You will be responsible for any damage if this warning is ignored. ** Power Requirements For High Pressure Facial Lamp ** If 120/208-volt circuit is supplied to the bed it will require a transformer for the high-pressure facial lamp. This lamp is powered with a 220-volt ballast. A special transformer is required for this scenario. Forever Tan sells this transformer that we will install during delivery. Transformers are not included in the price of the bed/unit and must be purchased separately. Transformers are available from the Forever Tan Parts Department.

***Forever Tan does not do any electrical wiring. The electrician must do the prewiring then return for the final hook-up during the equipment installation. This includes the wiring of any transformers. ***Due to insurance and liability reasons NO employee of Forever Tan is allowed (either written or verbally) to include any wiring with the purchase of tanning equipment from Forever Tan. ***Employees of Forever Tan do not mount timers or body fans to walls. ***The factory is allowed by ETL to size the wire coming out of the beds to match the amp draw not the size of the circuit (Appliance Rule). Wire gauges may be smaller (or larger for phase conversion purposes) than listed for circuit. *** All information concerning wire gauge and breaker size are calculated using the NEC table B-310-1 for 75 degree Celsius wire no more than three conductors in a raceway or cable in free air. Electrical contractors should verify all information on wire gauge and breaker sizes. Forever Tan will take no responsibility for any miscalculations or any misprints. *** Forever Tan will allow all beds to be cord and plug connected. Forever Tan requires that the conversion from hard-wire to cord and plug be made externally. Forever Tan will not provide materials and/or labor for any conversions. ***All information is subject to change at the manufactures and Forever Tan s discretion. If you have any questions please call Jeremy Welch at (704)971-4744

TIMER WIRING INFORMATION The cable required for the Single Station remote timers is a 4 conductor 24 AWG flat cable commonly known as Silver Satin. It can be purchased from Forever Tan Service Department. The cable required for the CCS IV Back-Bone System is a 4 conductor 24 gauge shielded cable. It can be purchased from Forever Tan Service Department. The Back-Bone System is used when networking multiple beds to the Intellitan CCS IV or T-Max Manager Pro main station timer. The Back-Bone System utilizes a single continuous run of 4 conductor 24 gauge shielded cable that starts in a single-gang box near the mounting location of the CCS IV or T-Max Manager Pro main station timer, from there it loops through (12 inches, uncut) single-gang boxes in each room and terminates in a single-gang box in the last room. After the cable has been pulled and looped through each box a 110 punch-down jack (AMP 41106- RI6) is installed on the cable (using a punch-down style jack eliminates the need to cut the cable). The jack is then mounted to the faceplate (AMP 41080-1IP) the faceplate is then attached to the single-gang box. The jacks may be purchased from Forever Tan Service Department for $3.00 each and the faceplates for $2.00 each. Forever Tan Service Department will install the jacks and plates (at the time of delivery of the units) for an additional $5.00 per room, provided that the cable and the single-gang boxes have already been installed by you (the owner) or your electrician PRIOR to the delivery of your tanning units. (See diagrams.). IMPORTANT NOTE; The CCS IV or T-Max Manager Pro main station timer requires a 120 volt outlet within 4 feet of where the timer will be mounted. This does not have to be a dedicated circuit. IMPORTANT See individual diagrams for placement of outlet boxes. Forever Tan does not do any pre-wiring or installing of timer wires. We recommend having an electrician do this for you. The wire is available from the Forever Tan Parts Department. No employee of Forever Tan is allowed (either written or verbally) to include any timer wiring with any purchase of tanning equipment from Forever Tan. Forever Tan will (for additional charge) terminate the timer connections upon delivery of the beds/equipment if the pre-wiring is complete. Forever Tan does not mount timers on the walls.

BACK-BONE TIMER WIRING DIAGRAM ELECTRICAL CONNECTION: JUNCTION BOX MOUNTED 12-18 INCHES OFF FLOOR WITH THE APPROPRIATE DEDICATED CIRCUIT PULLED INTO IT. SINGLE GANG OUTLET BOX WITH A 12 INCH LOOP (UNCUT) OF 24 GAUGE 4 CONDUCTOR SHIELDED WIRE. RESTROOM 232 240 240 ** SEE INDIVIDUAL DIAGRAMS FOR RECOMMENED PLACEMENT OF OUTLET BOXES CCS IV MAIN STATION REMOTE TIMER SINGLE GANG OUTLET BOX - THIS IS WHERE THE 24 GAUGE 4 CONDUCTOR SHIELDED CABLE MUST START FROM. 232 E600 120 VOLT OUTLET WITHIN 4 FEET OF WHERE THE TIMER WILL BE PLACED. E600

Placement of single gang box containing network wire for the following equipment models: Sundash 232, 226, 332 240, Advantage, Evolution, Excellence, and all Soltron units. This placement is approximately 12 inches off side wall and 24 inches from the floor Side wall, 232,226, 332 240, Advantage, Evolution, Excellence And all Soltron units Front of bed T This unit requires a minimum room size of 8 x 7. The hallway should be a minimum of 48 wide and a doorway size of at least 36.

Audio Speaker Placement Speaker Placement To have your wall or flush mount speakers directly behind the customer s head they should be placed on the wall to the left side of bed, 30 from back wall, 23 off the floor. *Speaker placement was measured allowing 6 inches of clearance at the back of the unit for electrical hook-up. You may use the equipment measurements provided to draw a footprint of the unit on the floor of the room and determine where you want the speaker.

Soltron Seashell XXS/35 HVAC 1 page This unit produces 31,301 BTU s of heat per hour. The factory recommends a minimum of.58 tons of A/C to offset the heat produced by this unit. Please consult a Mechanical Contractor. The heat is exhausted out the back of the unit and is forced straight up by a 1750cfm fan. Open Ceiling vs. Dropped Ceiling Forever Tan has found that (if feasible) it is best to leave the ceiling open. If the ceiling is open and the A/C is piped down it allows the heat to rise past cool air. This makes it easier for the cool air to reach the floor. A dropped ceiling traps the heat and makes it harder for the cool air to reach the floor (it also warms your cool air before it has a chance to reach the floor). When an open ceiling is used the Mechanical Contractors should run all hard ductwork. This will consist of a main trunk line with 8-12 round pipe dropped over each room (hard duct allows it to be painted). ***Theses numbers are only recommendations, the mechanical contractor should calculate the A/C requirements, taking in to consideration the unique aspects of each space or building. If you have any questions please e-mail Jeremy Welch at jeremyw@forevertan.net or at (704)971-4744.