RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators

Similar documents
bout your HOUSE Hydronic Radiant Floor Heating CE 4

General System Layout Sketch

General System Layout Sketch

Radiant Snap-In Formed Metal Panels

Radiant Lay-In Formed Metal Panels

Heating Installation Guide published by

REHAU Radiant Heating Systems. A warm welcome

The skirting board that heats your home...

BASE-RAY CAST IRON BASEBOARD RADIATION

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

General System Layout Sketch

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

RADIANT HEAT. Construction Automotive Industry

UNDERFLOOR HEATING SYSTEM C SYH ME UNDERFLOOR HEATING SYSTEM. Heating Homes All Around The World.

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Panel Radiators. For Buderus Panel Radiator models: Applications Manual. - Model 21 - Model 22 - Towel Warmers

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

Gas-Fired Unit Heaters Commercial & Industrial

America s favorite hot water baseboard radiation

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

A: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance.

Well Tanks and Expansion Tanks

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

Case Study - Yardley Park Road Gerpex MLCP and Press Fit System, Underfloor Heating and Manifold Based Sanitary Systems

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Heating Products M arch 2012

2015 MECHANICAL CODE REQUIREMENTS

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

G124X - G234X - G334X Atmospheric Gas Boilers

You thoughtfully chose each color, each fabric, every detail, all to give your home a feeling of warmth.

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

FIRST Heating. Company and product overview

Range Brochure July heatingthroughinnovation.

Click Here To View Item at

Making Crimp Connections

Intelligent Heating for Your Home

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Tuzio Milano Towel Warmer

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Marine Coolant Heater Catalog

Safe Heating in Sheltered and Social Housing

UNITAIRE IV FAN COIL UNITS

HE360 Humidifier Installation Kit

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

PENSOTTI TOWEL BAR WARMERS

DISHWASHER INSTALLATION INSTRUCTIONS

EXTROL EXPANSION TANKS

2012 INTERNATIONAL FUEL GAS CODE VENTS

The Art of Building Science

Solar Information. Solar Radiant Heating. Innovating Today s Solar Technology for the Future of Tomorrow

SERIES CONVECTION OVENS

TCV-1. Convector Steam and Hot Water Unit Heaters

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

at in Bathroom radiators are where fashion and function come together in perfect harmony. With everything

APEX. FAMILY of HOMES. from Redman Homes

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

CONNECTION SYSTEM AUGUST Reliance Worldwide USA

UNDERFLOOR HEATING GUIDE

Product and installation manual. Underfloor Heating

southpaw enterprises, inc.

Radiant Heating. feels so good. Why. Difference. Home WARMTH WHERE IT MATTERS RADIANT COMFORT NOT HOT AIR IN THE COMFORT ZONE

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

TWINTEMP JR. HYDRONIC SYSTEM 2/2013

SMART+ PRODUCTS Infrared Heater. Safety Notice

Installation Instructions

Heat Pumps COMFORT NEED IT. When You

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

24 VAC SYSTEM CONTROL KIT

Tough on Winter, Easy on You

CONTENTS. 6 DSCS Series Gas-Fired High-Intensity Patio Heater. 12 DGS Series Filtered Short-Wave Electric Infrared Heater

Lubrication Tools and Equipment Portable Oil Drains

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

Oslo Range Fast, Efficient, Scandinavian Heating

Cabinet Unit Heaters Steam / Hot Water

Trianco Ltd, Thorncliffe, Chapeltown, Sheffield, S35 2PH Telephone: Facsimile: Website:

FRESH FLOW WASTEWATER SYSTEM

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

oem OEM 1" Between the Glass Metal Blind Series P2100 Included:

Hydronic Radiators by Runtal

installation and operation manual for Hunter Ceiling Fans

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

MERIT SERIES Up Flow / Horizontal

Marine Catalog. Marine Catalog. Sure Marine Service, Inc th Ave. N.W. Seattle, WA (800) (206)

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

DUCTING & VACUUM HOSE

installation and operation manual for Hunter Ceiling Fans

SECTION HEATING TERMINAL UNITS

Transcription:

RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING www.b Unique, slim-design baseboard radiators

The RESCOM 2100 system is unlike traditional baseboard heating systems. Smooth flat panels are easily secured to the wall. Hot water circulates through the panels emitting a radiant heat that warms objects and people in the room. This quiet, efficient and even heat source can satisfy all of your heating requirements, from a small kitchen to a large family room, a complete house or office. Once installed, the panels are virtually invisible, blending into the decor of the room. LOOKS GREAT - simulates a baseboard - only 7-1/8" high and 1-1/16 deep. Constructed from tough extruded aluminum and covered with high impact baked appliance enamel for added good looks and durability. Available in custom colours at an additional charge. Panels may also be painted with any high quality oil based paint to match your decor. www.ba 2

UNIQUE SLIM-LINE DESIGN - blends into any interior setting for residential, commercial, or industrial applications and allows freedom of furniture and curtain placement, as there are no ducts, no vents and no restriction of airflow. CONSISTENT TEMPERATURES - are maintained throughout the room as gentle radiant warmth is provided from the panels. SAFE HEAT - designed at a water temperature of 160 F (71 C), which provides a safe panel surface temperature. HEALTHY HEAT - is provided as most of the heat is generated by radiation, which does not create air currents for dust and dust mites to travel on. This is a major benefit to allergy sufferers. ENERGY EFFICIENT - temperatures at the floor and ceilings are virtually the same allowing more comfort at a lower thermostat setting. (There is no heat blanket at the ceiling). Room by room control allows for even greater savings by reducing heat in areas used less frequently. SILENT OPERATION - only moving part is a small electric circulation pump. www.b EASY INSTALLATION - flexible polyethylene tubing can be run through existing floors and walls. Reflecto-Foil reflective insulation is provided with each panel and is applied behind the panel to assure heat is directed into the room, not into the wall. Dependable compression fittings allow for complete hook-ups to all panels and manifold without soldering. Quick fastening system means simple and low cost or do-it-yourself installation. 3

www.b RESCOM 2100 - hot water baseboard is available in TWO unique versions: System I. For installations using a hot water boiler (closed loop). System II. For installations with a certified dual-purpose potable hot water heater. All plumbing components are 3rd party certified for potable water. Perfect for basements, additions, sun rooms, added heat in cold areas, etc. 4

FREQUENTLY ASKED QUESTIONS WHAT ABOUT OPERATING COSTS? Savings of as much as 75% can be achieved by converting from traditional heating systems. The system can be run using any type of hot water source. HOW WILL THESE PANELS LOOK IN MY ROOM? Having no vents or openings, these sleek, unobtrusive looking panels are 1-1/16" (27 mm) wide and 7-1/8" (18 cm) high, tight against the wall. They can easily be painted to match or complement the colours in your room. HOW EASY ARE THE PANELS TO INSTALL? Unlike standard panels, there is no cutting or soldering involved. The panels come complete with mounting brackets, reflective insulation and brass compression fittings for simple connections. CAN I HEAT SMALL, HARD TO HEAT AREAS? Yes. The panels are designed to be stacked, run vertically or horizontally, placed along the floor or anywhere on the wall to provide the heat you need. MY HOUSE ALWAYS SEEMS DUSTY. CAN THIS PROBLEM BE SOLVED? Since radiant heat does not rely on air movement, there is no dust or pollen that is blown around the room. This also means a more uniform distribution of heat throughout the room. www.ba 5

Technical Data MATERIAL: System I Baseboard - 6063 Aluminium; System II Baseboard - 6063 Aluminium, astmb88 Copper tubing Thermal Linear Expansion Coefficient: per inch degree Fahrenheit = 13.5 x 10-6 Dimensions: Panel size - depth 1 1/16" (2.7cm), Height - 7 1/8" (18.1cm); Wall thickness - 0.09 inches, (0.23cm) Weight: System I Baseboard - 1.7 lbs. / foot (2.5kg / meter); System II Baseboard - 2.1 lbs. / foot (3.2kg / meter) Operating Temperature: Design Temperature - 160 degree F (71 degree C), can be as low as 120 degrees F Maximum recommended - 180 degree F (82 degree C) Water Content: System I Baseboard - 2.774 US gallon per 100 feet; System II Baseboard - 1.840 US gallon per 100 feet; 1/2" pex tubing - 0.920 US gallon per 100 feet Antifreeze: If required a heat exchanger is to be used between boiler and closed heating loop. Fittings: Brass Compression type Zone sizing: Recommended zone size is 30 feet of panel plus 100 feet of tubing. Circulation Pump Sizing: Using 1/2" piping charts, calculate the total pressure drop by adding the total number of feet of Tubing used plus the total lineal feet of panel used x 2 plus 4 feet for each panel used (for end fittings in each panel) for the longest loop = equivalent 1/2" tubing. Multiply this number by the head loss per foot for the desired gallon per minute flow rate. You can now select the appropriate circulation pump size from the circulator charts. www.b 6

PANEL HEAT OUTPUT PER LINEAL FOOT (BTU) Test results have been adjusted to reflect a 15% radiant efficiency factor. Data derived from factory tests February 1996. Complete test data available on request. WATER TEMPERATURE INPUT/ BTU OUTPUT PER FOOT DEGREE FAHRENHEIT 120 130 140 150 160 170 180 System I @ 1 Gallon 187 201 230 288 316 374 460 System II @ 1 Gallon 129 144 173 201 230 244 288 System I @ 2 Gallons 230 288 316 345 374 403 488 System II @ 2 Gallons 144 187 201 230 259 288 316 www.ba 7

PARTS & INSTALLATION GUIDE MATERIALS: Aluminum Baseboards, Aluminum Cover Plates, Cover Supports, Copper "U" Bends, Copper 90 Degree Bends, Galvanized Steel Mounting Brackets, Reflecto-Foil Insulation PANEL SIZES: 2 ft. to 10 ft. in 1 ft. increments Panels can be custom cut. Price is charged at next size up. (ie. 2-1/2' = 3' cost) * Simple, fast installation with compression fittings; no cutting or soldering. * Compatible with 1/2" Pex tubing or 1/2" standard copper tubing * Save as much as 75% of energy costs over traditional heating systems. * Ideal for existing or new residential or commercial applications. * Clean, sleek design eliminates openings, dust catchers and dust movement. * Rugged design can take everyday abuse from children, furniture, etc. * Panels can be positioned horizontally or vertically for areas with limited space. * Standard colour is trim white, but panels are easily paintable. www.b 8

Installation This guide assists you in easily designing and installing the Rescom 2100 system. Although this system is very easy to install, we advise you to contact your local municipal planning department regarding the design of your new hot water heating system to ensure that it conforms to local plumbing and heating codes. 1. A proper heat-loss calculation for your house and a system layout should be done to determine the number of feet of panel required to satisfy your heating needs. 2. Determine what will be the source of hot water for your heating system (i.e. boiler, hot water tank, etc.). You must allow for control and safety devices in the system. 3. Install both a return and supply line from your heating source. (We recommend Pex tubing be used due to its ease of use and superior strength and durability.) Send the tubing up through the wall or along the floor joists to the point where you plan on locating the first Rescom 2100 panel in the specific loop. Note: a maximum of 30 linear feet of panel is to be used in one loop. www.ba 9

4. Tuck the enclosed section of Reflecto-Foil insulation into the back of the Rescom Rad. Next, insert one of the enclosed mounting brackets into one end of the panel and screw the bracket to the wall. If carpet is to be laid after installation, you should raise the panel accordingly. Then insert the second mounting bracket into the other end of the panel and screw to the wall. Wall plugs may be required to secure the mounting brackets. See diagram #1. Diagram #1 10

5. Connect the supply and return tubes to the first end of the panel. The enclosed compression fittings allow for simple installation of the panel. Slip the nut over the end of the pipe, then the compression ring. Next the 1/2" insert slips into the end of the pipe, if you are using Pex tubing. If you are using copper, eliminate the insert. The nut and compression ring then attach to the end of the panel. Using two wrenches, hold the brass fitting on the panel while tightening the nut around the tubing being sure the tubing stays pushed fully into the fitting. Ensure the fittings are secure and tight. See Diagrams # 2 and # 3. Do NOT over tighten! Diagram #2 www.b Diagram #3 11

6. Secure the supply and return tubing at the other end of the panel, and continue the tubing to the next section of panel. Continue until you have reached the end of your loop. At the end of the loop, a copper "U" bend is to be used to complete the loop. The "U" bend is attached to the panel in the same manner as the Pex tubing using the compression fittings but eliminating the 1/2" insert. See diagram # 4. www.ba Diagram #4 12

7. Next, snap cover plates onto either end of the panel to conceal the tubing and fittings; trim and cut cover plates, if necessary, to accommodate tubing. 8. The system is now ready to be filled and tested for leaks. Depending on the design of your system, water or a combination of water and glycol can be used (i.e. cottage application). Once the system has been filled, re-tighten all compression fittings. 9. If a manifold controls your system, the manifold should be located near your heating source and include a filling and venting device as well as an expansion tank. It is advised that the loops that service different rooms of the house are identified at the manifold (i.e. living room, bedroom, etc.). 10. To clean the panels, use mild soapy water or WD-40. www.b 13

CORNER ASSEMBLY Inside Corner Assembly One cover panel has notches to accommodate 90o bends 1. Slide notched cover into place first www.ba 14

2. Then butt up a 12 cover plate against it. www.b 15

CORNER ASSEMBLY Outside Corner Cover Plate www.ba 16

STACKED PANEL ASSEMBLY Double Stacked Triple Stacked www.b 17

www.bas Panel end with fixtures 18

www.ba Copper U-Bend installed 19

www.ba Copper 90 Degree Bends attached to only one panel 20

www.b Interior view of Outside Corner Cover Plate covering Copper 90 Degree Bends 21

www.ba Exterior view of Outside Corner Cover Plate 22

www.b Inside corner showing 90 Degree Copper Bends intalled 23

www.ba Inside corner with Inside Corner Cover Plates ready to slide into place 24

www.b First Inside Corner Cover Plate slid into place 25

www.ba Both Inside Corner Cover Plates slid into place 26

www.b Backside view of Inside Corner Cover Plates slid into place 27

For more information: Call: 905-428-0146 email: info@baseboardrads.com Visit: www.baseboardrads.com www.ba 28