Addendum for STI-6406 with Dual Access Control

Similar documents
Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Illuminated Stopper Station Push Button

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Installation and ZONES: Operation Manual. Model: ON STI-34108

STANDARD FEATURES SPECIFICATIONS

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper II Heated Enclosure

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Installation Instructions

Child Resistant Pool Alarms

Installation Guide for models:

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Pilfergard Door Alarms

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ANNUNCIATOR FIXED MODULE

AED Alarm System Model Operations Manual

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

MODEL B2 INSTALLATION MANUAL

Gate Mount Pool Alarms

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Installation Guide for models:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

MANUAL RESET ALARM RELEASE

Series. Access Power Controllers. Installation Guide

SPECIFICATIONS. Contents List

Wireless D.I.Y. Alarm Kit

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Stopper II SERIES ADA. We protect the things that protect you

Independent Zone Control (I.Z.C.)

WM3000 WIRELESS MODULES

NetworX NX-548E Receiver Installation Instructions

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

MANUAL RESET ALARM RELEASE

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

EVO192 v3.0 Fire and Burglary What s New

User Manual X8s Access Control System

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Carbon Monoxide Transmitter

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

CM800 Emergency Call System

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

DS160/DS161 Request To Exit PIR sensors Installation Instructions

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Conventional Releasing Control Panel

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

TRX MAINS CONNECTION DIAGRAM

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

CORNELL Emergency Response Systems

Alarmed Exit Hardware

ELECTRONIC SOUNDER STROBE Model : AVD-C407

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

AL600ULADA. NAC Power Extender. Installation Guide

Remote Display Alarm Indicator for Oxygen monitor

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Public Safety DAS Annunciator Panel

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Installation Instructions

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Shed Alarm Kit. User Manual

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

AL800ULADA. NAC Power Extender. Installation Guide

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

DE5300 Delayed Egress System. General Information

4100U City and Relay Cards Installation Instructions

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

ALARMED EXIT HARDWARE

General Purpose IO Technical Manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Pump-Up Controller MODEL 4062

DS160/161 Request To Exit PIR sensors Installation Instructions

Delayed Egress System DORMA EMDE

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Installation, Operating and Maintenance Manual

1. POWERPATH Operation

TECHNICAL DATA OBSOLETE

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Transcription:

Addendum for STI-6406 with Dual Access Control Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with a DPDT key switch, but without an alarm for the opposite side of the door. An authorized person with a key can disable the alarm on either side of the door. When disabled, and LED will illuminate, and the door can be opened without setting off the alarm. After passing through the door, the alarm can be armed again from the opposite side. Installation: 1. Follow STI-6400 mounting instructions and set switches to the desired positions for alarm timing and volume. 2. For straight through door or wall installation, mark the center of the 5/16 inch hole in the mounted base, then remove the base from the door or wall. 3. Drill a 5/16 inch diameter hole through the door or wall at the marked location. 4. Align the same diameter hole in the secondary unit base to the back side of the door or wall and mount. 5. Route the wire from the STI-6400 unit through the hole and into the secondary unit. 6. Attach the 6 wires to the terminal block pins 2 thru 7 matching wire colors on the terminal block label. 7. Seal the hole around the wires with an effective fire stop material, if required. 8. Attach the battery in the secondary unit and install the cover. 9. Cycle the key switch to be sure the LED s turn ON and OFF. Leave the LED s ON until ready to test the alarm. 10. Attach the battery to the STI-6400 and install the cover. 11. Close the door and test. Operation: 1. With the door closed, turn either key switch to arm the alarm. The LED s on both sides of the door should turn OFF. 2. If the door is opened while the LED s are OFF, then the alarm will sound according to the switch settings of the STI-6400. 3. To reset the alarm, turn either key to the opposite position (the LED s will turn ON ), close the door and turn either key switch again (the LED s will turn OFF ). 4. When the system is armed, authorized passage can be accomplished by turning either key switch until the LED s turn ON, and remove key. The door can now be opened without sounding the alarm. When passage is complete, close the door, turn the key switch (the LED s will turn OFF ). The door alarm is once again armed. Schematic Diagram: 13 February 2017

Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left or next to almost any door. User can select on-site whether to use an alarm or annunciator. Less expensive than heavy horizontal bar type units and practical for all emergency doors. Contact STI for custom applications. We protect the things that protect you. - 1 -

Table of Contents Warnings and Cautions... Page 2 Warranty Information... Page 2 Specifications... Page 3 1. Dimensions... Page 3 2. Polycarbonate... Page 3 3. Electronics... Page 3 4. Remote Horn... Page 3 Circuit Board Set-Up... Page 4 Terminal Strip Layout... Page 4 Switch Settings... Page 4 Alarm Feature Description... Page 5 Installation Instructions All Units / STI-6400... Page 5 Mounting Options... Page 6 STI-6402 Double Door additional install notes... Page 6 STI-6403 Remote Horn additional install notes... Page 6 STI-6404 Double Door with Remote Horn additional install notes... Page 6 STI-6405 Exit Stopper with Momentary Reset... Page 6 Warnings All units are recommended for indoor use, not for outdoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional exit stopper units. When purchasing a remote unit (STI-6403 or STI-6404) you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Maximum of three remote alarms may be used in parallel. All specifications and information shown are current as of publication and subject to change without notice. Warranty Information Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14-2 -

Specifications Polycarbonate Enclosure Dimensions 5.375 W x 5.375 H x 2 D (137mm x 137mm x 51mm) Flammability UL94 V-2 Wall Thickness 0.12 in (3.05mm) Electronics: STI-6400 - All Units 9 VDC Alkaline or 9V-24VDC wired Power Source Class II UL Listed transformer Horn Volume at 1 ft. 95 db low / 105 db high Relay Output Form C Dry Contacts 0-30 VDC or VAC, 1 Amp Stand by Current 10uA Alarm Current 130mA at 95 db / 200mA at 105 db Operating Temperature Range 32 to 113 F (0 to 45 C) Electronics: STI-6403 and STI-6404 - Remote Horn Unit Power Source 9 VDC operating power* only Horn Volume at 1 ft. 95 db low / 105 db high Stand by Current 0 A Alarm Current 50mA at 95 db/ 200 ma at 105 db * Power source for the STI-6403 and STI-6404 Remote Horn uses a separate power source from the STI-6400 alarm. The Remote Horn contains an internal 9 volt battery. Horn operates when the Form C contact at main unit is activated on alarm. - 3 -

Circuit Board Set-up ALARM VOLUME SWITCH (ON) DOOR PROP SWITCH (OFF) JP2 JP5 TERMINAL BLOCK ALARM DURATION SWITCH (OFF) (OFF) JP4 JP3 (FACTORY DEFAULT SETTINGS) JUMPER WIRE ARMING SWITCH (ON) JP7 FORM C DRY CONTACTS REMOTE POWER INPUT 9-24 VDC REED SWITCH TERMINALS KEY SWITCH TERMINALS NC COM NO GD V+ RS1 RS2 KEYSW TERMINAL BLOCK WIRING CONNECTIONS Figure 1 All models are shipped with jumper wire installed for use with one reed switch (RS2). If using second reed switch, remove jumper wire and insert second reed switch. Switch Settings FEATURE JP2 JP3 JP4 JP5 JP7 Volume - POLYCARBONATE High (105 db) BASE at 1 ft. ON* Volume - Low (95 db) at 1 ft. OFF Duration - 30 Second Alarm OFF* OFF* Duration - 180 Second 120 db HORN Alarm OFF ON Duration - Continuous Alarm ON OFF Duration - Annunciator Mode ON ON Trip - Immediate POLYCARBONATE COVER Door Prop Mode Arming - Immediate Arming - 30 Second Delay OFF* ON ON* OFF Slide black lever to desired ON/OFF position as labeled on circuit board. *Factory Settings - 4 -

KEYSW NC COM NO GD V+ RS1 RS2 KEYSW Alarm Feature Description Volume Switch JP2 - Sets alarm volume to high 105 db or low 95 db. Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming resets at end of duration if door is closed. Alarm will not reset if in continuous mode; alarm will sound until reset with the key or until battery is drained. Annunciator mode will sound a series of short beeps until door is closed or 15 seconds. Door Prop Mode Switch JP5 - Once unit is armed with the key (OFF to ON) the alarm will sound if the door remains open for 15 seconds. If the door opens and closes within 15 seconds, the alarm will not sound. Arming Delay Switch JP7 - Delays arming of alarm for 30 seconds. To start arming delay timing, cycle the key switch (OFF to ON). Door must remain closed for 30 seconds for alarm to arm. Test Alarm Note: STI recommends testing the alarm in factory settings (see Switch Settings) prior to mounting. 1. Make sure key switch is in the OFF position. 2. Remove tamper screw on the side of the unit using the tamper wrench provided. Remove housing cover. Save the tamper wrench for future service and battery replacement (Fig. 2). 3. Connect battery. 4. Place magnet next to reed switch. Note: For STI-6402 model, insert jumper wire in RS2 terminals or install second reed switch and place magnet next to reed switches 1 & 2. 5. Turn the key switch to the ON position. 6. Move magnet away from reed switch. Unit should alarm immediately. 7. Turn unit off with the key to silence alarm. Installation Instructions 1. Set switches on circuit board to desired alarm settings (Fig. 1). 2. If using external power source, use Class II UL Listed transformer. 9V battery will be in no-load standby. 3. Mount main unit on or next to the door using hardware provided. Reed switch may be moved to one of four positions shown in Fig. 2 or you may route the reed switch through the knockout in the bottom of the cover as shown in Fig. 3. 4. Mount magnet using hardware provided. Magnet must be within ¾ of the reed switch when door is closed. Please refer to figures 7, 8 and 9 for other mounting options. Note: When mounting on metal doors or door frame, use plastic spacers provided. Magnet must be within 3/8 of the reed switch when door is closed. 5. If installing STI-6402, STI-6403, STI- 6404 or STI-6405 continue to page 6. 6. Replace cover by sliding flanges on inside of cover into slots on base, snap closed and replace the tamper screw. SCREW 6 x 1 1/4 in. - 5 - EMERGENCY USE ONLY ALARM SOUNDS WHEN DOOR IS OPENED ON OFF COVER REED SWITCH MOUNTING LOCATIONS (LABELED 1-4) NC COM NO GD V+ RS1 RS2 KEYSW FLANGES VIEW SHOWING MAGNET INSTALLATION MAGNET COVER 4 MOUNTING SCREW (4) PROVIDED SLOTS 1 TERMINAL STRIP 9 VOLT BATTERY 2 TAMPERPROOF SCREW (1) PROVIDED 3 TAMPER WRENCH BASE (1) PROVIDED FLANGES REMOVE FRONT COVER AND ROUTE REED SWITCH WIRES THROUGH NOTCH ON BOTTOM SURFACE AS SHOWN MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOOR AND FRAME REED SWITCH MOUNTING LOCATIONS SPACERS (USE AS NECESSARY) NOTE: 2 SPACERS UNDER BOTH 4 MAGNET AND REED SWITCH MUST BE USED ON STEEL DOORS ANCHOR Figure 2 Figure 3

STI-6402 Double Door Install Notes 1. If not using extra reed switch, leave jumper wire across terminals RS2 on terminal block. 2. Determine length needed for reed switch wires. STI provides 1 reed switch with 6 ft. wires. Cut to desired length. 3. Connect first reed switch in RS1 and second in RS2 (Fig. 5). (Refer to Fig. 1 for additional details.) *Note: Alarm will sound when either door is opened. TERMINAL BLOCK OPTIONAL: TO REMOTE HORN STI-6403 INTERNAL REED SWITCH (RS1) TO KEY SWITCH VIEW SHOWING INSTALLATION OF ADDTIONAL REED SWITCH KIT-E06402 KIT-E06402 REED SWITCH (RS2) Figure 4 STI-6403 Remote Horn Install Notes 1. Remove cover. 2. Connect two conductor wire (14-24 AWG) from main unit terminal block pins COM and NO to remote horn unit terminal block. (wire not provided). Units can be set up to 300 ft. apart. Not polarity sensitive (refer to Fig. 1 and Fig. 5 for details). 3. Connect internal battery. 4. Mount similar to main unit with #8 x 1 in. screws and anchors if necessary. 5. Replace cover and screws. 6. Turn key switch to ON position. *Note: The ON/OFF key position is opposite from 6400 main unit. Remote horn sounds when main unit alarm is activated. ROUTE WIRES THROUGH NOTCH KEY SWITCH STI-6403 REMOTE HORN UNIT INSTALLATION Figure 5 STI-6404 Double Door with Remote Horn Install Notes The STI-6404 is a combination unit for double doors with a remote horn. Reference the installation instructions for the main unit, the STI-6402 and the STI-6403 for complete installation. STI-6405 Exit Stopper with Momentary Reset The STI-6405 uses a momentary switch. After initial installation, unit is always on and you do not have to remember to turn it on when you leave a protected area. This model also eliminates having to remember to re-arm it because it is never off. When the alarm is triggered, to silence the alarm, insert the key and turn completely to the RESET position and hold for 2 seconds, then release. The switch will spring back to its original position and push the key out. To turn the unit off, supply power must be removed. - 6 - RESET Figure 6

INSTALLATION SCREW Mounting 6 Options x 1 1/4 in. SCREW 6 x 1 1/4 in. MAGNET MUST BE INSTALLED OPPOSITE RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS TYPICAL FLUSH MOUNT DOOR JAMB INSTALLATION ANCHOR MAGNET MAGNET MUST BE INSTALLED OPPOSITE 6400 UNIT RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS DOOR ANCHOR MAGNET SWING 6400 UNIT DOOR SWING JAMB DOOR STOP DOOR JAMB DOOR STOP DOOR Figure 7 TYPICAL RECESSED MOUNT DOOR JAMB INSTALLATION MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) TYPICAL RECESSED MOUNT DOOR JAMB INSTALLATION DOOR STOP MAGNET MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) 6400 SWING DOOR STOP 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME DOOR SWING MAGNET 6400 SWING *Note: When mounting reed switch on door and the main unit on wall, wire DOOR service loop must be used. SWING Figure 8 TYPICAL DOUBLE DOOR INSTALLATION STI-6402 INTERNAL REED SWITCH (RS1) - 7 -TO KEY SWITCH Figure 9

2306 Airport Rd Waterford, MI 48327, USA Phone: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Safety Technology International Ltd Taylor House 34 Sherwood Road Bromsgrove Worcestershire B60 3DR England Tel: +44 (0)1527 520 999 Fax: +44 (0)1527 501 999 info@sti-emea.com www.sti-emea.com Printed in USA Subject to change without notice. - 8 - Inst. 6400 SEPT2014