Technical Specification Guidelines

Similar documents
Table of contents. Introduction Design. 2. Installation. Attachments

6. Detail drawings. 1. Lap Splices 2. Corners 3. Penetrations 4. Terminations 5. Anchoring 6. Membrane cover

INSTALLATION GUIDELINES FOR GEOTEXTILES USED IN FILTRATION AND DRAINAGE APPLICATIONS

EROSION & SEDIMENT CONTROL

Subsoil conditions are examined using test borings, provided by soil engineer (geotechnical).

A PVC geomembrane integrated in the landscape

Firestone GeoGard EPDM Review of Technical Performances

Aquaculture Lining Systems

E R O S I O N C O N T R O L

CAPPING OF A GOLD MINE IN ROSIA MONTANA, ROMANIA

GEOMEMBRANE FIELD INSTALLATION

Firestone EPDM Geomembrane Review of technical performances

511 - RIP RAP - OPSS 511 ROCK PROTECTION - OPSS 511 GRAVEL SHEETING - OPSS 511 GEOTEXTILE - OPSS 511

Section Specification for Geotextile Used in Permanent Erosion Control Application

Civil engineering Fibertex Geotextiles

Selecting the Right Closure Cap Option for Your Surface Impoundment or CCR Landfill

AASHTO M Subsurface Drainage

V. EROSION CONTROL. -Drainage swales separation -Under rip-rap protected -Under rip-rap unprotected

The use of geosynthetics in the installation of ballast layers

Exposed Geomembrane Cover Systems for Coal Ash Facilities

Alternative Names: Erosion Control Matting, Erosion Control Netting, Rolled Erosion Control Products (RECP)

Geomembranes and Geosynthetic Clay Liners (GCLs)

ACTIVITY: Geotextiles ES 12

Geomembranes that work

POND SEALING OR LINING GEOMEMBRANE OR GEOSYNTHETIC CLAY LINER

Pozidrain. A guide to the selection and specification of Pozidrain drainage geocomposite

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

D.P.E. Enviroliner. geotextile protection layer. covering new ground 2016

B511 - RIP-RAP, ROCK PROTECTION AND GRANULAR SHEETING - OPSS 511

IMPORTANT CONSIDERATIONS FOR LEAKAGE CONTROL OF EXPOSED GEOMEMRANE-LINED PONDS

APPENDIX E COMPACTION CHARACTERISTICS AND EQUIPMENT

Urban Conservation Practice Physical Effects ESTABLISHMENT, GROWTH, AND HARVEST NUTRIENT MANAGEMENT

Civil engineering Fibertex Geotextiles

SHOREMAX FLEXIBLE TRANSITION MAT INSTALLATION GUIDE

Geomembranes that work

INSTALLATION GUIDELINES. Landfills and mines

RevETMax TM INSTALLATION GUIDE

Geosynthetics and Their Applications

HYDRAULIC DESIGN involves several basic

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS

Alternative Cover Systems

SWANA/A&WMA s. Third Annual Landfill Operator s Training Geosynthetics in Landfills. February 13, 2013

Geosynthetics for Erosion Control and Reinforcement

Firestone Lining Systems. Dependable Performance in Demanding Environments

Landfill Closure, Intermediate Cover & Post-Closure Care. Municipal League Meeting

COIR GEOTEXTILES. Er. Sheela Mary Cherian, M.Tech, Assistant Executive Engineer. Woven coir netting / Mesh matting used as geotextiles

Structural Storm Water Best Management Practices (BMPs)

REHABILITATION OF SAIDA DUMPSITE

APPLICATIONS IN FILTRATION AND DRAINAGE & EROSION CONTROL

CHAPTER 8 SLOPE STABILITY ANALYSIS

GEOSYNTHETIC-STABILIZED VEGETATED EARTH SURFACES FOR ENVIRONMENTAL SUSTAINABILITY IN CIVIL ENGINEERING JIE HAN PH.D.

Chesapeake Energy Center. Submitted To: Chesapeake Energy Center 2701 Vepco Street Chesapeake, VA 23323

GEOMEMBRANES FOR SEEPAGE CONTROL IN DAMS: NEW TECHNOLOGIES IN REHABILITATION AND NEW CONSTRUCTION

GIBE III: A ZIGZAG GEOMEMBRANE CORE FOR A 50 M HIGH ROCKFILL COFFERDAM IN ETHIOPIA

Add Value DECORATIVE PONDS NATURAL PONDS REFLECTION PONDS KOI PONDS WATER GARDENS STREAMS WATERFALLS PONDLESS WATER FEATURES

NOTICE OF INTENT. Submitted To: Bremo Power Station 1038 Bremo Bluff Road Bremo Bluff, VA 23022

Low Gradient Velocity Control Short Term Steep Gradient [1] Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent

Coir Block System (fabric attached coir block) add New Dimension to Streambank Stabilization Projects

field note Culvert foundation improvement design concepts The challenge of low-cost culvert foundations

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

A Collection and Removal System for Water in the Final Cover Drainage Layer

III.DRAINAGE. This section describes the use of geotextiles in underdrains for two different field conditions:

LANDFILL FINAL COVER AND MANAGEMENT OF LEACHATE SEEPS BELOW FINAL COVER

Appendix G. Detailed Design

and Water Features and Water Features

-AIHL NOISE UNIFIED SOIL CLASSIFICATION SYSTEM. Aqx. R CORPS OF ENGINEERS, U. S. ARMY APPENDIX A

Installation Manual May 9/14 No revision

Earthen embankments, which

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No.

CONSTRUCTION SPECIFICATION FOR RIP RAP, ROCK PROTECTION AND GRAVEL SHEETING

Geosynthetics: GEOTEXTILES ASDSO WOVEN GEOTEXTILE GEOSYNTHETICS IN DAMS. Geosynthetics in Dams, Forty Years of Experience by J.P.

HIGH PERFORMANCE COAL COMBUSTION RESIDUAL (CCR) SOLUTIONS

Table 4.7.1: Swales Potential Application and Storm Water Regulation

815 NE 172 nd Avenue Vancouver, WA Installation Manual

Guidelines for Installing Rolled Erosion Control Products in Slope, Channel and Shoreline Applications Laurie Honnigford

MATERIAL SPECIFICATION FOR GEOTEXTILES

DESIGN GUIDE.

Bituminous Geomembranes in Canal Construction for Irrigation Projects

SPECIAL SPECIFICATION 3687 Impermeable Liner

Liner Construction & Testing Guidance Overview

Natura Geo Mat. Brief Note on the System, Functioning and Peripheries

2.1.4 Roof Downspout Rain Gardens

Road Soil. Curtis F. Berthelot Ph.D., P.Eng. Department of Civil Engineering. Road Soil Introduction

317)

A. Install all temporary erosion control measures (in accordance with MNDOT General Conditions 2573) prior to site disturbance.

6.1 Bioretention Areas

Low Flow Rates Low Filtration Sandy Soils Medium Flow Rates Medium Filtration Clayey Soils [1] High Flow Rates High Filtration Polluted Soils

WQ-07 INFILTRATION TRENCH

Advantages gained from the use of a geomembrane waterproofing system on RCC dams: experiences from Australia

GEOWEB slope & shoreline protection OVERVIEW

Workshop On Capping Design In South Africa. Product Showcase By. Tyrone Naidoo

INSTALLATION GUIDELINES. Mirafi FM Filter Geotextiles for Basal Filtration Applications

Biotechnical streambank stabilization

Subgrade Preparation. Subgrade Preparation. Subgrade 3/27/2016. Tim Crosby: Grading Superintendent Chris DeJulio: Site Manager

Subsurface Infiltration Bed

Advanced Foundation Engineering. Soil Exploration

Applications of Coir Fibre Products in Environmental Erosion & Sediment Control and Restoration

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Washtenaw County Conservation District 7203 Jackson Rd Ann Arbor MI Phone: (734) x 5 Fax: (734) Web:

ENVIRONMENTAL ENGINEERING LAND SURVEYING

Transcription:

SECTION I- DESIGN CONSIDERATIONS PAGE 1.01 APPLICABILITY...I.2 1.02 PROTECTION AND PRECAUTIONS...I.3 1.03 SITE AND SUBSTRATE CONSIDERATIONS...I.3 1.04 PRODUCT CONSIDERATIONS...I.8 1.05 FASTENING CONSIDERATIONS...I.9 1.06 FIRESTONE EPDM GEOMEMBRANE FIELD SEAMING PROCEDURES...I.9 1.07 FLASHINGS AND PENETRATIONS... I.9 1.08 COVER SOIL CONSIDERATION AND ACCESS RAMPS...I.10 1.09 QUALITY ASSURANCE (MANUFACTURER & CONTRACTOR EXPERIENCE)...I.10 1.10 JOB SITE CONSIDERATIONS (CAUTIONS AND WARNINGS)...I.10 1.11 WARRANTY...I.10 - I.1 -

SECTION I- DESIGN CONSIDERATIONS This manual contains information on lining systems using Firestone EPDM Geomembrane. Apart from general recommendations on the use of the sheet, it also gives general information on site, design, and excavation considerations. As a product manufacturer, Firestone does not perform geotechnical or other design functions. The following information is provided as general guidelines and design considerations only. Generally, for simple projects, the design may be carried out by the owner or the contractor. However, in the case of larger ponds, canals, water features and commercial installations the problems are often considerably more complex. In these installations, it is recommended that a licensed engineer, geologist or architect be consulted to ensure that the project is designed in accordance with applicable standards and performs as desired. 1.01 Applicability A. The Firestone EPDM geomembrane System is appropriate for any of the following installations: 1. Irrigation systems a. Canals b. Reservoirs c. Dam facings 2. Waste containment Municipal or Agricultural a. Floating covers b. Municipal landfill covers 3. Aquaculture a. Pond liners b. Tank liners c. Raceways B. The Firestone EPDM Geomembrane System is not appropriate where any of the following conditions exist: 1. Any containment structure where conditions exist that the substrate will not provide continuous and uniform support for the Firestone EPDM Geomembrane. 2. Any containment for hydrocarbons or chemicals that known to damage Firestone EPDM Geomembrane. C. The Firestone EPDM Geomembrane System is not applicable without special consideration from Department, where any of the following conditions exist: 1. The Firestone EPDM Geomembrane will be subjected to chemical discharge 2. Where the side slopes exceed 2H:1V. 3. Projects where the water table may reach the elevation of the liner. 4. Any project where subterranean gases are known or suspected to exist. - I.2 -

5. Any project that may contain hot liquids where the temperature of the liquid may exceed 80C (180F). 1.02 Protection and Precautions A. Additional precautions and/or protection may be required in the following situations: 1. Wind a. Ballast at the bottom, on slopes at the top of slopes b. Correct section of anchor trench depending on pullout calculation 2. Waves Mechanical protection of the embankments depending on slope (rock, precast blocks, cast-in-place-concrete) 3. Floating objects (dead wood and debris) a. Small ponds: cleaning b. Large ponds: protection of side slopes 4. Ice - Mechanical protection of embankments 5. Animals a. Escape ladders or access sections b. Fence around reservoir c. Geotextile under the Firestone EPDM Geomembrane on slopes d. Soil cover in high traffic areas 6. Vandalism a. Enclosure around reservoir b. Mechanical protection of embankments 7. Operating vehicles a. Protection of the Firestone EPDM Geomembrane with a soil layer minimum 18 inches (450 mm) in depth b. Access ramp protection for embankments 8. Local turbulence (with water velocity exceeding 1.2 m/sec (4.0 ft/sec) (internal agitator or canals)) a. Protection with designed cover system or ballast 1.03 Site and Substrate Considerations A. Site Selection- When selecting the construction site, there are numerous design elements that must be considered to ensure long-term performance of the system and to avoid future problems. Site selection is the responsibility of the design professional. 1. The nature of the soil substrate 2. The presence of cavities (karst terrain) 3. The depth to and the variation of the groundwater level 4. The presence of gases in the soil (i.e. peat, organic matter) 5. The risk of differential settling (i.e. poorly consolidated soil, recent backfill, landfills) 6. The risk of internal erosion (i.e. karst soils, fine silty sands) - I.3 -

B. Site Layout- The layout of the water feature may be executed by means of one of the following methods: 1. Fully excavating natural soil 2. Building raised embankments 3. Partial excavation with raised embankments C. Soils 1. A thorough geotechnical investigation of the site should be conducted to ensure that the underlying soil will remain stable. 2. The type of soil (classification) density, permeability, thickness of the strata, and the depth under the lining system must be known. The table below outlines some risks based on general soil types. 3. The soil supporting the Firestone EPDM Geomembrane system should be compacted to between 90% and 95% of Standard Proctor density, either by construction equipment or by mechanical vibrating roller compacting. Table 1.1 SOIL TYPE RISK SOLUTION Compressible (peat, fine sand, Gas generation Gas Drainage etc.) (PT, OH, OL, ) Loose backfill Pressure under Firestone EPDM Geomembrane Slope must be adapted to facilitate gas drainage Settling Appropriate compaction Under-consolidation of methods backfill materials Differential settlement and tearing of Firestone EPDM Geomembrane Soil containing organic matter (old sugar or paper industry ponds, landfill, peat) (PT, OH, Decomposition/gas generation Pressure under membrane Gas drainage OL, ) Soil with internal erosion potential (backfill material containing waste, limestonetype soil, gypsum chalk) Dissolution of the soil by liquid due to a leaking lining system Collapse caused by eroding water Soft clay, silt Differential settling and tearing of the Firestone EPDM Geomembrane Coarse substrate soil (GW, GP, GM GC) Puncture of Firestone EPDM Geomembrane Change site or provide a good geological assessment to find cavities, if any Special reinforcement, double waterproofing or compaction An intermediate layer for drainage and special compacting around penetrations Provide geotextile protection - I.4 -

D. Slopes If no slope stability study is carried out, the contractor shall provide a maximum recommended slope of 2H:1V. If the height of the embankment (above the base of the pond) is between 4.6 and 9.2 m (15.0 and 30.0 ), a maximum slope of 3H:1V is recommended when a soil cover is to be used. The values in Table 1.2 may be used as a general guide for exposed installations. These values are given according to a uniform type of soil. They should be considered as general guidelines only. Slope stability is the responsibility of the design professional. 1. Bottom a. A slope of 1% to 2% is recommended for the following: 1) Correct operation of the drainage system 2) Easy maintenance of the pond (if unprotected) 3) Positive gas movement 2. Side Slopes or Embankment Inclines Stability of the impoundment are geotechnical and geosynthetic issues. The presence of groundwater and the nature of the soil play an important part in the stability of the side slopes. The Firestone EPDM Geomembrane system is not to be used to provide stability of the side slopes. The minimum stability study shall deal with the following: a. The stability of the drainage system and of other layers between the bottom of the pond and the Firestone EPDM Geomembrane. b. Effects of waves c. Consequences of rapid drop in water level d. Consequences of excessive leakage e. Stability of the protection layer, (max. slope for soil cover is 3H:1V) f. Ease of installation TYPE OF SUBSTRATE Clay Sandy Clay Sand, Sandy Gravel Soft Factured Rock Table 1.2 MAXIMUM SLOPE 2H:1V 2.5H:1V 3H:1V 1.5H:1V 3. Top of slope crest a. The crest shall have a minimum width as follows: 1) 1.5 m (5.0 ) for installation of the anchor trench 2) 4.5 m (15.0 ) if vehicles are used during the construction and operation of the water feature. - I.5 -

b. If a minimum width cannot be obtained, adequate anchoring methods (like an anchor trench) must be used. Also, a slight incline of 1% towards the outside of the water feature is recommended for drainage. E. Drainage The need for a drainage layer beneath the membrane depends on local site conditions. In all cases, where liquid may cause instability of the subsoil, the amount of water in the soil should be minimized. This may be done by means of a drainage system. The application of a drainage system is not required if the permeability of the supporting layer exceeds 10-4 m/s or if no gas pressure is anticipated. Water/gas drainage is always required under the following conditions: 1. When water flows are possible under the Firestone EPDM Geomembrane, in soils where erosion may be possible (karst soil,...) 2. Soils containing organic matter (gas generation) 3. Slopes containing clay (stability when emptying...) 4. Whenever variations of groundwater level can be anticipated 5. Whenever the Firestone EPDM Geomembrane is not fixed and can move (wind...) 6. Rise of the groundwater level/gas entrapment 7. Groundwater level exceeding the pond water level: If the ground water level is higher that the bottom of the water feature, the Firestone EPDM Geomembrane lining system will be subject to hydrostatic backpressure (i.e. uplift). Also, air may be entrapped, causing gas pressure from the groundwater as the level rises. The depth of the groundwater table must be known (both the average level and the extreme level). If the groundwater elevation exceeds the lowest elevation of the Firestone EPDM Geomembrane system, the Firestone EPDM Geomembrane risks being lifted and the function of the gas drainage system (if installed) may be disturbed. In this case, an appropriate drainage system under the Firestone EPDM Geomembrane membrane, including ballast on top of the Firestone EPDM Geomembrane, should be provided. Groundwater drainage systems must be designed by a design professional. a. Rapid emptying (draw down) of the pond with high groundwater level. 8. Water drainage and gas drainage are often combined. For this reason, a slope of 1 to 2% of the base toward the side slopes is recommended. The water drainage may be facilitated by means of one of the following: a. A layer of cohesionless soil (sand or fine gravel) with a minimum thickness of 304.8 mm (12.0 ). b. A layer of permeable geosynthetic material (thick non-woven geotextile or drainage geocomposites). c. In order to prevent drain blockage, a natural or synthetic filter must be installed between the soil and the drainage layer. Rules for correct filter design should be followed. - I.6 -

d. A double lining system with a drainage layer between the two Firestone EPDM Geomembranes, or by covering the embankment crest with Firestone EPDM Geomembrane in order to avoid infiltration in back of the lining system. e. A network of drainage pipes linked to each other covered with permeable geotextile or a layer of permeable material. 1) Water can be collected by a network of primary and secondary collection pipes placed at the lower points of the pond or a layer of geonet composite placed over the entire pond bottom. For larger structures a compartmentalized drainage network is recommended to facilitate leak detection. 2) Size and gradient of water drainage system depends on the following factors: a) Leak flow rate that is acceptable. b) Flow rate of water coming from outside of the pond. c) Maximum pressures acceptable under the geomembrane. 3) For smaller projects the use of perforated drainpipes with a minimum diameter of 63.5 mm (2.5 ) is recommended. For larger structures, the size and the density of the network, as well as the compressive strength of the drainpipes, must be carefully designed. All drainage systems must be designed by a professional engineer. F. Substrate Venting A substrate venting system may be required. If so, a design professional with experience in design of similar systems should be consulted prior to commencement of any work. 1. The application of perforated pipes is recommended for less permeable soils. 2. It is recommended that the layout of the any system be done by a design professional. 3. A porous sand layer, geotextile or other permeable geosynthetic (geonet composites) should be placed between pipes. 4. A flat synthetic drainage system may be used as an alternative (geonet composites). 5. Any direct contact between the Firestone EPDM Geomembrane and an abrasive surface of the drainage system must be avoided. Protection using a geotextile underlayment is required. 6. Gas vents are required at the high points of the slopes and should be protected by a vent cap. G. Water Feature Length and Wave Action 1. Waves created by the wind or by boats can cause an impact on the side slopes. The greater the length of the pond in the direction of the prevailing winds and the steeper the slope, the stronger the wave action will be. 2. Depending on the specific height of the waves, the type of soil and the slope of the embankments, one or a combination of the following is recommended: a. Firestone EPDM Geomembrane protection adapted to the slope (concrete, concrete block mattress, rip rap, soil cover) b. Provide adequate anchoring of the Firestone EPDM Geomembrane lining system c. Provide adequate compaction of the base soil - I.7 -

d. Provide geotextile protection under the Firestone EPDM Geomembrane lining system e. Building a smaller but deeper water feature. f. Selecting another shape, with a shorter dimension in the direction of the prevailing winds. g. Building several smaller water features instead of one large water feature. H. Wind Uplift 1. In areas of high wind ballasting with sand bags may be necessary. 2. Ballasting may be removed if and when permanent ballast is installed (i.e. water, cover layer, etc.) I. Maximum Liquid Level The higher the liquid level in the pond, the higher the hydrostatic pressure. The risks of the base soil settling and the membrane tearing are also increased. Even when considering the high elongation at break properties (500%) of the Firestone EPDM Geomembrane lining systems, cavities may be present in the soil that could cause the membrane to be punctured, especially if the soil contains rock. To avoid this risk, a fine grained intermediate layer of sand or clean soil and/or the installation of a geotextile underlayment is recommended. 1.04 Product Considerations A. Membranes: 1. The Firestone EPDM Geomembrane is a fish friendly synthetic rubber membrane. The panels are assembled in the factory prior to vulcanization in order to limit on-site field seaming. The panels are folded and rolled on cores 3.30 m (10.8 ) long. 2. Refer to product TIS for factory panels sizes. a. Thickness 1.14 mm (0.045 ), 1.52 mm (0.06 ) and 2.29 mm (0.90 ) b. Scrim reinforced EPDM Geomembrane is also available in 1.14 mm (0.045 ) and 1.52 mm (0.06 ). c. Each roll is labeled with the membrane type, thickness, dimensions, manufacture date, and production lot, and an arrow indicating direction of unrolling. Firestone also offers a reinforced liner in 3.05 m (10.0 ) wide panels and the lengths shown above. 3. All elements of the Firestone EPDM Geomembrane lining system shall be Firestone products as described in the Technical Data Sheets or products, which are approved by Firestone. B. Underlayments 1. Firestone can provide a geotextile that is acceptable as an underlayment. 2. Other geotextiles may be acceptable, but should be verified with the design professional and Firestone prior to installation. - I.8 -

1.05 Fastening Considerations A. Perimeter Anchoring 1. Anchor Trenches An anchor trench in the shape of a U or V can be used as a perimeter termination. The trench is excavated and the membrane is loose laid in it. The trench is then backfilled and compacted with the excavated material or concrete. Pullout calculations shall be completed by a design professional to determine the dimensions of the anchor trench for any given project. In any event, the top of slope runout length to an anchor trench should be a minimum of 0.91 m (3.0 ). 2. Top Run-outs The top of the bank is scraped smooth back a specified distance. The membrane is loose laid and after the pond is filled then the edge is covered with ballast of a sufficient amount to ensure perimeter securement. B. Intermediate Anchoring If the embankment is high and/or long, it may be necessary to provide intermediate anchoring to reduce the potential for membrane movement. In these cases, a bench may be added along the incline in order to provide slope stability of the embankment. Ballast applied over the membrane at the bench may provide the desired stability. C. Toe of Slope / Bottom Ballast In some cases, especially on large reservoirs, temporary and/or permanent ballast (soil cover) may be required due to operating conditions or wind conditions. Additionally and especially on embankments or dam facings a toe of slope anchor trench may be required. D. Head Water Terminations Where water enters the lined area special considerations must be made for terminating the membrane to ensure that the termination remains intact and does not erode due to the flow into the lined area. E. Mechanical Terminations Mechanical terminations shall be done in accordance Firestone specifications and details. 1.06 Firestone EPDM Geomembrane Field Seaming Procedures Two overlapping Firestone EPDM Geomembrane panels are seamed by means of a patented splicing tape or cap strip system. Section 2.08 of the Installation Guide provides details of the various steps required for correct seam procedures for the Firestone EPDM Geomembrane. 1.07 Flashings and Penetrations A. Firestone recommends a minimum clearance of 304.8 mm (12.0 ) between penetrations, pipes, conduits, etc. B. Where possible, provide a minimum design height of at least 203.2 mm (8.0 ) for all flashing terminations except Pre-molded QuickSeamPipe Flashings. C. When using a surface mounted termination (i.e. termination bar) ensure the surface termination provides a constant seal on the substrate. - I.9 -

1.08 Cover Soil Consideration and Access Ramps (base only or on side slopes) A. Cover soil can and is commonly installed over the Firestone EPDM Geomembrane System: 1. It provides protection from mechanical damage (i.e. golf spikes, equipment, vandalism, etc.) but it is not required for UV. 2. Cover soil is installed to provide habitat for fish and plant life. 3. Cover soil is installed for additional protection from intense wildlife traffic. 4. Cover soil maybe used to provide a more aesthetically pleasing appearance. B. Concrete and shotcrete can be installed over and adjacent to the Firestone EPDM Geomembrane System: 1. It provides a durable wear surface for pads and access points for a. Agitators b. Aerators c. Other mechanical equipment 1.09 Quality Assurance (manufacturer and contractor experience) A. A Firestone trained installer must install the Firestone EPDM Geomembrane System for issuance of a Firestone material warranty. B. Projects with membrane only warranties are not always inspected by Firestone. C. Consultation: 1. Department is available for consultation with respect to any deviations from Firestone specifications and details. 2. If there is any deviation from these specifications without first obtaining written approval from the Department, it may not be possible for Firestone to issue the desired warranty. 1.10 Job Site Considerations (cautions and warnings) A. Protect the membrane against wind by ballasting the bottom or side slopes and designing the perimeter attachment properly. B. Ensure against mechanical damage from floating objects (i.e. dead wood), ice, operating vehicles, equipment, etc. C. Animals can present significant problems. Provide escape ladders, fence around reservoirs and use a geotextile under the membrane to prevent damage. D. Confirm compatibility of the membrane with all materials being stored or retained in conjunction with the membrane. E. Confirm the suitability of the compacted substrate to ensure that it will have sufficient structural integrity to fully support the membrane and specify repair as required. F. Asphalt, coal tar pitch, oil or plastic cements are not to be used in direct contact with components of the Firestone EPDM Geomembrane System. G. Protect all components of the Firestone EPDM Geomembrane System from discharges or contact with petroleum products, greases, oils (mineral and vegetable), and animal fats. Contact Firestone Specialty Department for suggested methods of protection. - I.10 -

1.11 Warranty A. Upon acceptance of the installed Firestone EPDM Geomembrane System by Firestone, the requested warranty shall be issued. Only Firestone supplied components are covered by the Firestone warranty. B. See Warranty Section for a listing of available Firestone warranties for Firestone EPDM Geomembrane installations. - I.11 -