Comfort & Efficiency
Quiet Operation How many decibels do you think an HVAC system operates at? Have you heard our systems run? How quiet are they?
Air Filtration and Treatment Ion Deodorization Filter Apple-Catechin Filter Organic coating fin used heat exchanger P Pre Filter Antibacterial coated pre-filter Clean Bi-Weekly Wall Units Use A Different Special Air Cleaner On Each Side
Air Filtration and Treatment Ion Deodorization Filter Clean Every 3 Months Apple-Catechin Filter Organic coating fin used heat exchanger P Pre Filter Antibacterial coated pre-filter Clean Bi-Weekly Long-life* Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic Filter lasts approximately 3 years if washed under water to restore its surface action when dirty Wall Units Use A Different Special Air Cleaner On Each Side
Focus On Efficiency You can save your customer over $2,000 by selling them the least expensive HVAC system. Inexpensive 13 SEER Cooling and an 80% AFUE furnaceequipment + Or cheap You can save your customer $10,000 by installation selling them Fujitsu Mini-split heat pump systems = expensive utility bill.
A Truly Green Product RoHS Compliant Manufacturing Lower Factory C02 Output ISO 9002 / 14001 Certified High% Recyclable Product Soft Start Low Inrush Current 65-166% vs. 500% for conventional compressor Reduces peak electrical demand RoHS = Restriction of Hazardous Substances
Does Matter? Fujitsu Is Solar Friendly Soft Starting Compressor More than 2 million ENERGY STAR homes have been built in the United States. ENERGY STAR qualified homes will save more than $270 million this year on their utility bills.
The Smart Choice in Whole Home Comfort As much as half of the energy used in a typical home goes to heating and cooling. Decisions about home or business HVAC systems can have a big effect on utility bills and comfort. Where Does Your Money Go? If your average annual utilities are $4,200, Fujitsu can save you $1,050 annually or $10,500 in 10 yrs!* *Savings may vary based on model selected, hours of operation and geographical location. Example given based on 26-SEER system versus 13- SEER system.
Energy Savings Selling Tools $1600.04 + $2712.61 = $4312.65 per year estimated utility cost Using 3 12RLS systems not existing equipment to heat and cool the home: $4312.65 $2605.30 = ONLY $1707.35 per year estimated utility cost WWW.fujitsugeneral.com
Energy Savings Selling Tools Efficiency Energy Savings Calculator (3 Fold Paper) Slide Rule Calculator Uses: In home sales Estimate savings Show or event handout based on setting the Targeted Customer Mailings slide rule to the estimated or actual utility costs and system efficiencies. Great Selling Tool! Look for Energy Star!
Where Have You put a Fujitsu System? Fast food chains Fire houses Police stations Oil rigs Bars Sunrooms Additions Warehouses Nursing homes ATM vestibules Small offices... As long as it meets: The installation instruction requirements Proper design and sizing
Current Products single Most model warranties are. Existing inventory and some models still have 5yr compressor 2yr parts warranty
Extended Warranties Extended warranties are available under special contractor programs. EXTENSION OF THE STANDARD LIMITED WARRANTY It is possible to extend the parts warranty to ten (10) years or even twelve (12) years! Only Fujitsu Elite Contractors are eligible to provide their customers an extended warranty up to 12 years Check The Fujitsu General websites for more information
single 9,000 Btu.- 42,000 Btu. 11 indoor unit styles X models have long lines Dual zone 18,000 Btu. Tri zone 2-3 IU 24,000 Btu. Quad zone 2-3-4 IU 36,000 Btu. Mix & Match Indoor Units Cassette Concealed Wall Mount - Floor Mount 48,000 Btu Cooling 54,000 Btu Heating 2-8 Indoor Units Requires Branch Box Up to 33.0 SEER Up to 18 SEER Up to 17 SEER
Multi- Zone Mini-Split Systems
SEER Heat Pump Ratings SEER stands for Seasonal Energy Efficiency Ratio. Higher the SEER rating on the pump, the better the efficiency of that pump is. Most common measurement by which consumers measure the energy efficiency of the heat pump that they want to buy. This only refers to the cooling efficiency of the unit, so this will not be of much use to you if you want the pump specifically to generate heat. Outdoor temperature: 82 F Indoor conditions: 80 F/67 F(WB) SEER rating of a unit is the cooling output during a typical cooling-season divided by the total electric energy input during the same period.
9k Single Zone Wall Mount Heat Pump Fujitsu Is At The Top
12k Single Zone Wall Mount Heat Pump Fujitsu Is At The Top
HSPF or Heating Season Performance Factor. Most commonly used to measure of the heating efficiency of heat pumps. HSPF is a ratio of the heat output to watt-hours of electricity used over an average heating season. The higher the HSPF the greater the energy efficiency. New heat pumps manufactured after Jan 1, 2015 are required to have an HSPF of at least 8.2. The most efficient heat pumps have an HSPF of 14.
9k Single Zone Wall Mount Heat Pump Fujitsu Is At The Top (HSPF) Fujitsu Is At The Top (HSPF)
12k Single Zone Wall Mount Heat Pump
Single Combination Only Indoor Units Wall Mount Full Size Cassette Floor/Ceiling 9,000 to 42,000 BTU/h SEER ratings up to 33.0 HSPF up to 14.2 22 ENERGY STAR qualified systems ABU Floor Ceiling ASU Wall Mounts AUU Large Cassette 36 different systems available in 11 indoor unit styles
115 Volt Inverter Wall Mount 16.0 SEER 9.0 HSPF 9RL2 and 12RL2. What do I give up with the 115 volt model? Smaller LCD display on Remote Control Only 14 F low ambient cooling No Flex system compatibility No accessory communications or connections No remote shut down No wired remote control option Copyright @ 2013 Fujitsu General America, Inc
Up to 16 SEER 18,000 & 24,000 BTUs Heat Pump 165 Extended Piping Great For Churches & Schools
Single Ceiling Cassettes 18, 24, 36 and 42K BTU 42k -230ft(70m) Line-set 18-36k 165ft(50m) Line-set Up to a 98 Ft Rise 0 Degree (-18c) Low Ambient Cooling! Right Out Of The Box Built-in condensate pump. Pumps Come With All Cassette Models! 14-16 SEER Heat pump Ships With Wired Remote
Single Ceiling Cassette
Single Cassette Features You can block louver openings To add field supplied ducts. Maximum Two (2) Sides Suspended by - All Thread Rod A Maximum of 36% of units airflow can be in Ducts (That s from 2 ducts not 50%) *See product manuals for CFM available and static pressure limitations 2- four inch openings per side require adaptors to Y into selected duct size. FRESH AIR KIT AVAILABLE KHRS940-25 Fresh air fan, ductwork & controls field supplied
Airflow Options & Wired Remote 4-Way 3-Way 2-Way Option to enable Internal Thermosensor on wired remote for System Temperature Control Max. Piping Length - 165 small units to 230 larger unit Max. Piping Height - 65 small units to 98 larger 2 units Up to 16 units can run off one Wired Remote! Wired Wall Mounted Control with Weekly Timer
HFI Indoor Units single Optional Accessory Wall Mount Compact Duct Compact Cassette 7k Btu. 24k Btu. 7k* Btu. - 12k Btu. 7k*-12k Btu. - 18k* Btu. 18 Btu. - 24k* Btu. Floor Mount AGU Floor Mount ASU Wall Mounts AUU Compact Cassette ARU Compact Duct 9k Btu. - 15k Btu. *24k only available with 36k & 48K HFI Multi systems *7K models only available for use with Multi-zone combinations
Single Compact Cassette Up to 24 SEER Up to 13 HSPF Heating design down to -5 F. 9RLFCC 12RLFCC 18RLFCC Nominal Cooling 9000 12000 18000 Nominal Heating 12000 16000 21800 Min-Max Cooling 3100-12000 3100-13600 3100-20100 Min-Max Heating 3100-18000 3100-19400 3100-25600 SEER 24 21.9 20.1 HSPF 13 12.2 11.5
Single Compact Duct Up to 21.5 SEER Up to 12.2 HSPF Heating design down to -5 F. 9RLFCD 12RLFCD 18RLFCD Nominal Cooling 9000 12000 18000 Nominal Heating 12000 16000 21800 Min-Max Cooling 3100-12000 3100-13600 3100-20100 Min-Max Heating 3100-18000 3100-19400 3100-25600 SEER 21.5 20 19.7 HSPF 12.2 11.5 11.3
Compact Ceiling Cassette Fits in 2x2 Ceiling Grid! About 9 in. tall! 2 Stage Turbo Fan Ultra Quiet Low Speed Turbo Fan High Speed A Fujitsu Innovation! BTU. Single 9K - 12K - 18K Multi 7K - 9K - 12K 18k Optional- Accessory Wireless Remote Control
@ 16 in Fresh Air Kit Field Supplied external duct & powered intake system AUU_RLF - 9K -12K & 18k BTUs Multi-Split Heat Pump Systems! Factory installed condensate pump! (28in lift) Optional Accessory
Compact Duct Units ARU 7,000 Btu. 9,000 Btu. 12,000 Btu. 18,000 Btu. 24,000 Btu. Same cabinet size (33in lift)
Compact Duct Units Cabinet or Built In Ducted
Compact Duct Units MANDATORY Floor standing mode requires special settings. Set program function 12.4 temperature correction and switching the drain function. Drain pump cannot be used if it is installed in wall mounted type/floor standing concealed type. You must unplug the switch from CN9 on the small circuit board. BACK Next
11 1/8 In RLS2-RLS3 Wall Mount (9,12,15K) Single Up to 27.2 SEER 12.5 HSPF Super High SEER High HSPF 34 ¼ In. **RLS3 is NOT BACKWARDS compatible with RLS2 models. **RLS3 Single, units Multi are NOT and to be Flex-Multi used with any compatible multi-zone units. Ships with 7 day programmable wireless remote control
23 5/8 In. AGU Floor Mount Up to 26.0 SEER 12.6 HSPF AGU, 9,12,15 RLF Single, Multi and Flex-Multi compatible Single Ships with 7 day programmable wireless remote control
FLOOR MOUNT Three Simple Installation Options Beneath Standard Window Concave Install Low Wall Mount 37 23.6 27.5 Min. 27.5 29 7.9 Max. 6 FLOOR MOUNT
FLOOR MOUNT Fan Option User Selectable
Outdoor Temperature Cooling Capacities 11,210 Btu s at 95 F Indoor Target Temperature Found in the Design & Technical Manual
Outdoor Temperature - 5 F Heating Capacities 22,320 15,460 13,330 Btu s at 59 23-5 F AGU12RLF-12RLFF System Combination Indoor Target Temperature 70 F TC=Btu Actual Heating Capacity Ratings Found in the Design & Technical Manual
Single Single Zone High Heat Model AGU9,12,15RLF/AOU9,12,15RLFF (Low-Temperature Heating) Down to - 5 F 9RLFF 12RLFF 15RLFF 12.6 11.6 11.2 COP 4.00 3.27 3.34
Single Zone High Heat Model AGU9,12,15RLF/AOU9,12,15RLFFH - 15 F XLTH series (Extra-Low-Temperature Heating) Single 9RLFFH 12RLFFH 15RLFFH COP 4.00 3.27 3.34
- 15 F Heating Capacities AGU12RLFFH System Combination 14,350 Btu s at 23 F 7,850 Btu s at -15 F Found in the Design & Technical Manual
- 15 F Heating Capacities AGU12RLFFH System Combination 22,320 Btu s at 59 F 15,660 Btu s at 32 F 15.66 22.32 AFR : Air Flow Rate (CFM) TC: Total Capacity (kbtu/h) IP : Input Power (kw) Found in the Design & Technical Manual
HFI-Multi HFI-Multi uses ONLY the new compatible HFI indoor units They are NOT backwards compatible with ANY old model! They will ship with line adaptors for connection at the indoor unit
Traditional Split Systems vs. Zoning What a waste!
HFI-Multi AOU18RLXFZ 7,000-9,000 or 12,000 Btu. Indoor units ONLY Dual Zone 2 indoor units 14,000 21,000 BTU Connectable Capacity Uses Halcyon HFI Indoor Units!
HFI-Multi AOU24RLXFZ 7-9 - 12 or 18,000 Btu. Indoor units 2 or 3 Zones 14,000 27,000 BTU Connectable Capacity
Outdoor Unit AOU36RLXFZ (NEW) AOU36RLXFZ1 Was 16 Seer, NOW 18 SEER 10 NEW Operation Range is: 14 F - 115 F (Cooling), 5 F - 75 F (Heating) for Outdoors
HFI-Multi AOU36RLXFZ1 7-9 - 12, 18 & 24,000k Btu. Indoor units 2 to 4 Zones 27,000 39,000 BTU Connectable Capacity Example: Dual Zone with 2) 18,000 Btu. Indoors Quad zone with 3) 7k and 1) 12k Btu.
Halcyon HFI flex Basics This class does not provide Halcyon HFI Purchase Authorization! Or Qualification for Technical Support You Must take the online Halcyon HFI course to QUALIFY for purchase of this equipment from your distributor
What is Halcyon HFI? ybrid A customizable mini-split system with lex nverter 2 to 8 indoor units Only 1 outdoor unit. Halcyon: The Halcyon bird (Kingfisher) was believed to have the ability to control the wind. Reason: The Kingfisher flew onshore and nested at the beginning of the calmest weather of summer and then flew away just before the fall storms arrived, creating the legend. Usage: Halcyon Days The fondest memories from your past; of warm summer days gone by.
Halcyon Hybrid Flex Inverter System Install in limited spaces Compact and light-weight design Easier to bring to job site Easier to position and hide unit Wall Mounts Compact Cassette Concealed Ceiling Unit UTP-PU03A 3-Zone Primary Branch Box UTP-PU03B 3-Zone Secondary Branch Box Outdoor unit 36 inch 14.5 inch 38 inch Separation Tube Assembly kit
What s New? What's the big deal? I already sell and install Fujitsu Mini-splits, Existing they're easy. Existing Why AOU36RML1 Classic Multi AOU48RLXFZ do I need to more training? AOU36RML1 What s different? Indoor unit capacity match is based on a table of acceptable system matches. New AOU48RLXFZ1 The capacity of the combined indoor units can be greater Differences than the systems capacity System planning required careful unit & pipe layout 80-130% capacity 39,000 to 62,000 of indoor unit connectable capacity. The unit is rated for 48,000 Btu. Maximum total at one time.
What's a Branch Box Connects in refrigerant circuit between outdoor and indoor units. UTP-PU03A need 1 per system Add up to 2 secondary units below UTP-PU03B Add 1 for 4-6 indoor units Add a second for 7-8 units 2 models Primary UTP-PU03A Secondary UTP-PU03B 3 unit connections ea. Meter refrigerant based on demand from each zone independently Have Electronic Expansion Valves (EEV) that meter refrigerant for capacity control inside. A Maximum of 8 connections can be used for indoor units.
Branch Boxes All Flare connections Flare connection Outdoor unit side Liquid : 3/8 in. Vapor : 5/8 in. Indoor unit side Large : 1/2 in. Small : 1/4 in. 2 connections from outdoor unit or separation tubes Control box All fittings Including entire flare connection MUST BE INSULATED. 3 sets of connections exit to indoor evaporators Includes adaptors to the refrigerant pipe size for the indoor units Branch Boxes Not a weatherproof enclosure Cannot be mounted outside or in a space above 80% relative humidity May be installed in a storage space that is inside the insulated envelope of the building Factory Insulated Branch Box prevents need for a condensate drain line or a drain pan. Incorrect installation will void warranty and may cause electrical short in board.
ULTRA LOW TEMP SYSTEMS
Heating Units Indoor Units RLS2H XLTH series (Extra-Low-Temperature Heating) AHRI rated up to: 8.8 HSPF and 27.2 SEER ASU Current High SEER (27.2) The condensing units include: Modified base w/ pan heater Pan heater interface relay Special defrost control AGU
Outdoor Temperature MODEL: ASU9RLS2H Actual Heating Capacity Ratings 17,500 11,100 Btu s at 23-15 F Indoor Target Temperature 70 F TC=Btu Copyright 2015 Fujitsu General America, Inc.
9RLS3 series 12RLS3 series 15RLS3 series 9RLS3H series 12RLS3H series 15RLS3H series Replaces the RLS2(H)
World s Most Efficient Heat Pump
COP 5.33 4.64 4.59-5 F
RLS3: Improved Efficiency, Low Temp Heating Heating Capacity is impressive at low outdoor temperatures! High capacity is possible by using larger coils and a high capacity, yet very efficient compressor Operates in Heating down to -5 F Rated heating capacity maintained at 5 F Operates in Cooling down to 14 F RLS3 units are NOT backwards compatible with RLS2 equipment.
Outdoor Temperature - 5 F ASU12RLS3 Indoor Temp TC=Btu 70 F 19,600 15,000 25,300 Btu s at 32-5 59 F
EER SEER Larger heat exchanger (Coil) RLS2 RLS3 Volume Increased 200% Optimized Inverter Control Up 21% Up 20% 33.0 RLS2 RLS3 RLS2 Up 10% RLS3 RLS2 Up 10% RLS3 27.2 Minimum Intermediate Maximum Compressor Speed Percentage of increase may vary by model size 9RLS2 9RLS3 Achieves Super Efficiency
- 15 F H H H 14.0 13.8 13.3 COP 5.33 4.64 4.59
Heating Btuh Output Capacity 22,000 Btu Heat 47 F Nameplate Capacity Comparison 25,000 20,000 Fujitsu 9RLS3H Mitsu MUZ-FH09NA 11,100 Btu Heat -15 F 15,000 10,000 5,000 0 18,000 Btu Heat 47 F 47 F 41 F 32 F 23 F 17 F 5 F -4 F -15 F Outside Dry-Bulb Temperature Low Temperature Comparison 6,084 * Btu Heat -15 F *Estimate based on Mitsu s correction factor and O.D. WB
Without Extra Low Temp Heating Unit may frost up! - Due to continuous low outdoor temperature and high humidity. capacity shortage Noise Freezing of outside parts Decrease the amount of heat exchange Standard model Freezing of machinery room Contact of parts Freezing of base unit Blockage of drain hole * Low outdoor temp. * High humidity
Drain holes X Heater PAN Heater Included! Reduces Rated Efficiency However, competition requires accessory installation! Without a base pan heater ice can build up and crush refrigerant coils, causing expensive repairs. 2015 Fujitsu General America Inc. All Rights Reserved.
COP HSPF Intelligent Base Pan Heater Control 36 F (2 C) Ambient temperature ICY 41 F (5 C) RLS2H OFF Base pan Heater ON OFF Up 25% RLS3H* OFF ON OFF ON OFF ON OFF 11.0 RLS2H RLS3H Up to 10% RLS2H RLS3H Up to 50% Optimum Inverter control RLS2H RLS3H 8.8 Minimum Intermediate Maximum Compressor Speed RLS2H RLS3H RLS3 more efficient - Base pan heater is not on continuously
AOU18RLXFZH Dual Zone AOU24RLXFZH Dual & Tri Zone H H 10.3 10.3 60% Capacity at -15 F 0 SEER ratings up to 16% higher than current models in non-ducted combinations Outdoor temperatures down to -15 F (previous model +5 F)
Single Heat Pump Systems System 18CL System 24CL1 System 30CLX1 System 36CLX1 System 18RLB System 24RLB System 30RLXB System 36RLXB
Single Zone Heat Pump Models! 18RLB 24RLB SEER 19.0 / EER 12.5 / HSPF 10.6 / COP 4.11 SEER 18.0 / EER 10.0 / HSPF 10.6 / COP 3.65 30RLXB 36RLXB SEER 16.5 / EER 9.5 / HSPF 9.0 / COP 3.14 SEER 15.5 / EER 8.5 / HSPF 9.0 / COP 2.94
FEATURES HEATING & COOLING ONLY (OPTION) Need Cooling Only? Function codes can set unit to cooling Only! System 18RLB System 24RLB System 30RLXB System 36RLXB
AOU18RLXFZ AOU24RLXFZ AOU48RLXFZ1
Wire Kit # UTY-XWZX5 Turns system on/off using a normally closed circuit. Interface Kit # UTY-XCBZ2 (Used on: ASU9RLF1) Examples: Home automation or BMS integration of ONLY On/Off operation of Fujitsu system Occupancy Sensor of Key Card Switch Lead-lag control of supplemental heating or cooling Condensate pump alarm circuit Humidistat: turns system On/Off based on humidity, regardless of temperature Outdoor temperature sensor to shut system off and start a third party heating or cooling source Examples: Interface Kit (required to connect a wired or UTY-XWZX) Interface Kit # UTY-XCBXE (For 9RL and 12 RL Systems Only) Examples: Interface Kit (required to connect a wired or UTY-XWZX ) Previous models require a different wire kit. Check installation instructions.
Slim Duct Auto Louver Grill Operates with indoor unit Louvers can be controlled by remote control UP and Down auto swing Fixed airflow with 4 positions or auto swing Auto-closing louver When indoor stops, the louver closes. * Only compatible with ARU models with serial numbers greater than 2000.
Slim Duct Auto Louver Grill Product specifications are subject to change without notice.
Wired Remotes Standard on: Compact Cassette Units Single Large Cassette Units Concealed Ceiling Units Remote Controls Inverter & Multi-zone Wall Mount Wireless Remote A special option allows the user to enable an internal Thermosensor in wired remotes which may enable temperature sensing at the wall instead of in the return of the indoor unit in Most Models. NOTE> This Feature Is Wired Remote Accessories Non Inverter Wireless Remote With Halcyon HFI Wall Mount Wireless Remote Halcyon HFI Wired Central Remote -Works With individual unit remotes.
NE W REMOTE INTERNET MANAGEMENT
Manage remotely your HVAC system using a smart phone, tablet or PC via Internet from anywhere.
Home Owner From: - The Office - The Street - The Gym - Everywhere Internet Home WIFI ROUTER *Home Wi-Fi router is required
FEATURES AND BENEFITS
Automatic Air Direction - Heating Warm Air Rises & Cold Air Sinks Fujitsu Power Diffuser Directs warm air to floor Warm air spreads evenly No cold windy feel like from a traditional heat pump or even a poorly ducted warm air furnace
24RLXS Heating Airflow Airflow diagram over thermal image These charts are in the Design & Technical Manual Outside air conditions:35.6 F 60% Operation mode: Heating, Set temperature (Max set temp) Air flow Hi, Vertical flap : Downward
Please install indoor units so the warm air blows: Down the walls Toward cold areas Make my day and Heat The Room Not The Furniture!
Automatic Air Direction - Cooling Cold air is directed across the ceiling toward the heat causing it to cool your space more quickly and efficiently. Does not blow cold air on room occupants
Please install wall units up high on the wall so the cold air blows above my head. Make my day and Cool The Room Not The People!
ESP Energy Saving Program
ESP Energy Saving Program Fujitsu Halcyon RLS2 and NEW RLS3 systems save you money even if you forget. If you leave the room without turning the unit off, ESP knows that you left When movement is sensed the unit returns to the previous set temperature. ESP prevents wasteful operation to save energy without you having to think about it. Copyright 2015 Fujitsu General America, Inc.
If ESP does not sense movement in 20 minutes, it will set back. Cooling - Temp increases by 4ºF -up to a maximum of 86ºF. Heating Temperature decreases 8ºF down to a minimum of 60 degrees F. Copyright 2015 Fujitsu General America, Inc.
Selectable Feature The ESP Function can be turned on and off Copyright 2015 Fujitsu General America, Inc.