https://portal.fujitsugeneral.com

Similar documents
Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

Auto Louver : Up/Fown Auto Mode Minimum Heat Mode Economy Mode

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Residential and Light Commercial Ductless Systems Catalog

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

A single answer for multiple zones.

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

DUCTLESS SPLIT SYSTEMS

Geniuses at work. Residential Mini Splits

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

A single answer for multiple zones.

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Ductless Series Variable Speed Split Systems

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Lennox Mini-Split Systems Year-Round Comfort and Performance

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

2017 LINE UP MINI SPLITS CATALOG

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

THE WORLD S MOST EFFICIENT HEAT PUMP

HEAT PUMPS. Efficient Comfort For Every Season

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

DUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA ALEGRIA SERIES ALEGRIA

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA

InverterFlex SERIES InverterFlex Systems condition up to five rooms

DESIGN & TECHNICAL MANUAL

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

Hi-spec Design model. Photo : LT series

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

2017 LINE UP MINI SPLITS CATALOG

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

2 &3-4 Head Multi System

FUJITSU FLOOR CONSOLES FUJITSU

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

Product Brochure Smart Power. Low Profile Ducted

Mini-Split and Multi-Zone Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2016

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Product Brochure 2017

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

DESIGN & TECHNICAL MANUAL

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

duct-free air conditioning systems Art cool inverter flex multi-split

JUNE & 3-4 Head Multi System

3 rd Generation of VRV. The professional solution for your professional project

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

LV Series. SEER 20+ Wall Mount Heat Pump

"I'm a Daikin Comfort Pro"

Ducted inverter reverse cycle air conditioning

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

DUCTLESS FULL LINE CATALOG

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

AND WORRY-FREE PERFORMANCE

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

Up to SEER 26.1 Wall Mount Heat Pump

Haier Ductless Product Brochure

LG VRF Systems. Air Conditioning Technologies

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015

Product Data INDUSTRY LEADING FEATURES / BENEFITS

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Transcription:

https://portal.fujitsugeneral.com Is Your Company on Fujitsu s Toolbox? Online Training Sales Leads with Consumer Referrals Online Documentation Online Troubleshooting Downloadable Technical Bulletins Tech Tips Servicing Guides Training Registration And more!

Comfort & Efficiency

Quiet Operation How many decibels do you think an HVAC system operates at? Have you heard our systems run? How quiet are they?

Air Filtration and Treatment Ion Deodorization Filter Apple-Catechin Filter Organic coating fin used heat exchanger P Pre Filter Antibacterial coated pre-filter Clean Bi-Weekly Wall Units Use A Different Special Air Cleaner On Each Side

Air Filtration and Treatment Ion Deodorization Filter Clean Every 3 Months Apple-Catechin Filter Organic coating fin used heat exchanger P Pre Filter Antibacterial coated pre-filter Clean Bi-Weekly Long-life* Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic Filter lasts approximately 3 years if washed under water to restore its surface action when dirty Wall Units Use A Different Special Air Cleaner On Each Side

Focus On Efficiency You can save your customer over $2,000 by selling them the least expensive HVAC system. Inexpensive 13 SEER Cooling and an 80% AFUE furnaceequipment + Or cheap You can save your customer $10,000 by installation selling them Fujitsu Mini-split heat pump systems = expensive utility bill.

A Truly Green Product RoHS Compliant Manufacturing Lower Factory C02 Output ISO 9002 / 14001 Certified High% Recyclable Product Soft Start Low Inrush Current 65-166% vs. 500% for conventional compressor Reduces peak electrical demand RoHS = Restriction of Hazardous Substances

Does Matter? Fujitsu Is Solar Friendly Soft Starting Compressor More than 2 million ENERGY STAR homes have been built in the United States. ENERGY STAR qualified homes will save more than $270 million this year on their utility bills.

The Smart Choice in Whole Home Comfort As much as half of the energy used in a typical home goes to heating and cooling. Decisions about home or business HVAC systems can have a big effect on utility bills and comfort. Where Does Your Money Go? If your average annual utilities are $4,200, Fujitsu can save you $1,050 annually or $10,500 in 10 yrs!* *Savings may vary based on model selected, hours of operation and geographical location. Example given based on 26-SEER system versus 13- SEER system.

Energy Savings Selling Tools $1600.04 + $2712.61 = $4312.65 per year estimated utility cost Using 3 12RLS systems not existing equipment to heat and cool the home: $4312.65 $2605.30 = ONLY $1707.35 per year estimated utility cost WWW.fujitsugeneral.com

Energy Savings Selling Tools Efficiency Energy Savings Calculator (3 Fold Paper) Slide Rule Calculator Uses: In home sales Estimate savings Show or event handout based on setting the Targeted Customer Mailings slide rule to the estimated or actual utility costs and system efficiencies. Great Selling Tool! Look for Energy Star!

Where Have You put a Fujitsu System? Fast food chains Fire houses Police stations Oil rigs Bars Sunrooms Additions Warehouses Nursing homes ATM vestibules Small offices... As long as it meets: The installation instruction requirements Proper design and sizing

Current Products single Most model warranties are. Existing inventory and some models still have 5yr compressor 2yr parts warranty

Extended Warranties Extended warranties are available under special contractor programs. EXTENSION OF THE STANDARD LIMITED WARRANTY It is possible to extend the parts warranty to ten (10) years or even twelve (12) years! Only Fujitsu Elite Contractors are eligible to provide their customers an extended warranty up to 12 years Check The Fujitsu General websites for more information

single 9,000 Btu.- 42,000 Btu. 11 indoor unit styles X models have long lines Dual zone 18,000 Btu. Tri zone 2-3 IU 24,000 Btu. Quad zone 2-3-4 IU 36,000 Btu. Mix & Match Indoor Units Cassette Concealed Wall Mount - Floor Mount 48,000 Btu Cooling 54,000 Btu Heating 2-8 Indoor Units Requires Branch Box Up to 33.0 SEER Up to 18 SEER Up to 17 SEER

Multi- Zone Mini-Split Systems

SEER Heat Pump Ratings SEER stands for Seasonal Energy Efficiency Ratio. Higher the SEER rating on the pump, the better the efficiency of that pump is. Most common measurement by which consumers measure the energy efficiency of the heat pump that they want to buy. This only refers to the cooling efficiency of the unit, so this will not be of much use to you if you want the pump specifically to generate heat. Outdoor temperature: 82 F Indoor conditions: 80 F/67 F(WB) SEER rating of a unit is the cooling output during a typical cooling-season divided by the total electric energy input during the same period.

9k Single Zone Wall Mount Heat Pump Fujitsu Is At The Top

12k Single Zone Wall Mount Heat Pump Fujitsu Is At The Top

HSPF or Heating Season Performance Factor. Most commonly used to measure of the heating efficiency of heat pumps. HSPF is a ratio of the heat output to watt-hours of electricity used over an average heating season. The higher the HSPF the greater the energy efficiency. New heat pumps manufactured after Jan 1, 2015 are required to have an HSPF of at least 8.2. The most efficient heat pumps have an HSPF of 14.

9k Single Zone Wall Mount Heat Pump Fujitsu Is At The Top (HSPF) Fujitsu Is At The Top (HSPF)

12k Single Zone Wall Mount Heat Pump

Single Combination Only Indoor Units Wall Mount Full Size Cassette Floor/Ceiling 9,000 to 42,000 BTU/h SEER ratings up to 33.0 HSPF up to 14.2 22 ENERGY STAR qualified systems ABU Floor Ceiling ASU Wall Mounts AUU Large Cassette 36 different systems available in 11 indoor unit styles

115 Volt Inverter Wall Mount 16.0 SEER 9.0 HSPF 9RL2 and 12RL2. What do I give up with the 115 volt model? Smaller LCD display on Remote Control Only 14 F low ambient cooling No Flex system compatibility No accessory communications or connections No remote shut down No wired remote control option Copyright @ 2013 Fujitsu General America, Inc

Up to 16 SEER 18,000 & 24,000 BTUs Heat Pump 165 Extended Piping Great For Churches & Schools

Single Ceiling Cassettes 18, 24, 36 and 42K BTU 42k -230ft(70m) Line-set 18-36k 165ft(50m) Line-set Up to a 98 Ft Rise 0 Degree (-18c) Low Ambient Cooling! Right Out Of The Box Built-in condensate pump. Pumps Come With All Cassette Models! 14-16 SEER Heat pump Ships With Wired Remote

Single Ceiling Cassette

Single Cassette Features You can block louver openings To add field supplied ducts. Maximum Two (2) Sides Suspended by - All Thread Rod A Maximum of 36% of units airflow can be in Ducts (That s from 2 ducts not 50%) *See product manuals for CFM available and static pressure limitations 2- four inch openings per side require adaptors to Y into selected duct size. FRESH AIR KIT AVAILABLE KHRS940-25 Fresh air fan, ductwork & controls field supplied

Airflow Options & Wired Remote 4-Way 3-Way 2-Way Option to enable Internal Thermosensor on wired remote for System Temperature Control Max. Piping Length - 165 small units to 230 larger unit Max. Piping Height - 65 small units to 98 larger 2 units Up to 16 units can run off one Wired Remote! Wired Wall Mounted Control with Weekly Timer

HFI Indoor Units single Optional Accessory Wall Mount Compact Duct Compact Cassette 7k Btu. 24k Btu. 7k* Btu. - 12k Btu. 7k*-12k Btu. - 18k* Btu. 18 Btu. - 24k* Btu. Floor Mount AGU Floor Mount ASU Wall Mounts AUU Compact Cassette ARU Compact Duct 9k Btu. - 15k Btu. *24k only available with 36k & 48K HFI Multi systems *7K models only available for use with Multi-zone combinations

Single Compact Cassette Up to 24 SEER Up to 13 HSPF Heating design down to -5 F. 9RLFCC 12RLFCC 18RLFCC Nominal Cooling 9000 12000 18000 Nominal Heating 12000 16000 21800 Min-Max Cooling 3100-12000 3100-13600 3100-20100 Min-Max Heating 3100-18000 3100-19400 3100-25600 SEER 24 21.9 20.1 HSPF 13 12.2 11.5

Single Compact Duct Up to 21.5 SEER Up to 12.2 HSPF Heating design down to -5 F. 9RLFCD 12RLFCD 18RLFCD Nominal Cooling 9000 12000 18000 Nominal Heating 12000 16000 21800 Min-Max Cooling 3100-12000 3100-13600 3100-20100 Min-Max Heating 3100-18000 3100-19400 3100-25600 SEER 21.5 20 19.7 HSPF 12.2 11.5 11.3

Compact Ceiling Cassette Fits in 2x2 Ceiling Grid! About 9 in. tall! 2 Stage Turbo Fan Ultra Quiet Low Speed Turbo Fan High Speed A Fujitsu Innovation! BTU. Single 9K - 12K - 18K Multi 7K - 9K - 12K 18k Optional- Accessory Wireless Remote Control

@ 16 in Fresh Air Kit Field Supplied external duct & powered intake system AUU_RLF - 9K -12K & 18k BTUs Multi-Split Heat Pump Systems! Factory installed condensate pump! (28in lift) Optional Accessory

Compact Duct Units ARU 7,000 Btu. 9,000 Btu. 12,000 Btu. 18,000 Btu. 24,000 Btu. Same cabinet size (33in lift)

Compact Duct Units Cabinet or Built In Ducted

Compact Duct Units MANDATORY Floor standing mode requires special settings. Set program function 12.4 temperature correction and switching the drain function. Drain pump cannot be used if it is installed in wall mounted type/floor standing concealed type. You must unplug the switch from CN9 on the small circuit board. BACK Next

11 1/8 In RLS2-RLS3 Wall Mount (9,12,15K) Single Up to 27.2 SEER 12.5 HSPF Super High SEER High HSPF 34 ¼ In. **RLS3 is NOT BACKWARDS compatible with RLS2 models. **RLS3 Single, units Multi are NOT and to be Flex-Multi used with any compatible multi-zone units. Ships with 7 day programmable wireless remote control

23 5/8 In. AGU Floor Mount Up to 26.0 SEER 12.6 HSPF AGU, 9,12,15 RLF Single, Multi and Flex-Multi compatible Single Ships with 7 day programmable wireless remote control

FLOOR MOUNT Three Simple Installation Options Beneath Standard Window Concave Install Low Wall Mount 37 23.6 27.5 Min. 27.5 29 7.9 Max. 6 FLOOR MOUNT

FLOOR MOUNT Fan Option User Selectable

Outdoor Temperature Cooling Capacities 11,210 Btu s at 95 F Indoor Target Temperature Found in the Design & Technical Manual

Outdoor Temperature - 5 F Heating Capacities 22,320 15,460 13,330 Btu s at 59 23-5 F AGU12RLF-12RLFF System Combination Indoor Target Temperature 70 F TC=Btu Actual Heating Capacity Ratings Found in the Design & Technical Manual

Single Single Zone High Heat Model AGU9,12,15RLF/AOU9,12,15RLFF (Low-Temperature Heating) Down to - 5 F 9RLFF 12RLFF 15RLFF 12.6 11.6 11.2 COP 4.00 3.27 3.34

Single Zone High Heat Model AGU9,12,15RLF/AOU9,12,15RLFFH - 15 F XLTH series (Extra-Low-Temperature Heating) Single 9RLFFH 12RLFFH 15RLFFH COP 4.00 3.27 3.34

- 15 F Heating Capacities AGU12RLFFH System Combination 14,350 Btu s at 23 F 7,850 Btu s at -15 F Found in the Design & Technical Manual

- 15 F Heating Capacities AGU12RLFFH System Combination 22,320 Btu s at 59 F 15,660 Btu s at 32 F 15.66 22.32 AFR : Air Flow Rate (CFM) TC: Total Capacity (kbtu/h) IP : Input Power (kw) Found in the Design & Technical Manual

HFI-Multi HFI-Multi uses ONLY the new compatible HFI indoor units They are NOT backwards compatible with ANY old model! They will ship with line adaptors for connection at the indoor unit

Traditional Split Systems vs. Zoning What a waste!

HFI-Multi AOU18RLXFZ 7,000-9,000 or 12,000 Btu. Indoor units ONLY Dual Zone 2 indoor units 14,000 21,000 BTU Connectable Capacity Uses Halcyon HFI Indoor Units!

HFI-Multi AOU24RLXFZ 7-9 - 12 or 18,000 Btu. Indoor units 2 or 3 Zones 14,000 27,000 BTU Connectable Capacity

Outdoor Unit AOU36RLXFZ (NEW) AOU36RLXFZ1 Was 16 Seer, NOW 18 SEER 10 NEW Operation Range is: 14 F - 115 F (Cooling), 5 F - 75 F (Heating) for Outdoors

HFI-Multi AOU36RLXFZ1 7-9 - 12, 18 & 24,000k Btu. Indoor units 2 to 4 Zones 27,000 39,000 BTU Connectable Capacity Example: Dual Zone with 2) 18,000 Btu. Indoors Quad zone with 3) 7k and 1) 12k Btu.

Halcyon HFI flex Basics This class does not provide Halcyon HFI Purchase Authorization! Or Qualification for Technical Support You Must take the online Halcyon HFI course to QUALIFY for purchase of this equipment from your distributor

What is Halcyon HFI? ybrid A customizable mini-split system with lex nverter 2 to 8 indoor units Only 1 outdoor unit. Halcyon: The Halcyon bird (Kingfisher) was believed to have the ability to control the wind. Reason: The Kingfisher flew onshore and nested at the beginning of the calmest weather of summer and then flew away just before the fall storms arrived, creating the legend. Usage: Halcyon Days The fondest memories from your past; of warm summer days gone by.

Halcyon Hybrid Flex Inverter System Install in limited spaces Compact and light-weight design Easier to bring to job site Easier to position and hide unit Wall Mounts Compact Cassette Concealed Ceiling Unit UTP-PU03A 3-Zone Primary Branch Box UTP-PU03B 3-Zone Secondary Branch Box Outdoor unit 36 inch 14.5 inch 38 inch Separation Tube Assembly kit

What s New? What's the big deal? I already sell and install Fujitsu Mini-splits, Existing they're easy. Existing Why AOU36RML1 Classic Multi AOU48RLXFZ do I need to more training? AOU36RML1 What s different? Indoor unit capacity match is based on a table of acceptable system matches. New AOU48RLXFZ1 The capacity of the combined indoor units can be greater Differences than the systems capacity System planning required careful unit & pipe layout 80-130% capacity 39,000 to 62,000 of indoor unit connectable capacity. The unit is rated for 48,000 Btu. Maximum total at one time.

What's a Branch Box Connects in refrigerant circuit between outdoor and indoor units. UTP-PU03A need 1 per system Add up to 2 secondary units below UTP-PU03B Add 1 for 4-6 indoor units Add a second for 7-8 units 2 models Primary UTP-PU03A Secondary UTP-PU03B 3 unit connections ea. Meter refrigerant based on demand from each zone independently Have Electronic Expansion Valves (EEV) that meter refrigerant for capacity control inside. A Maximum of 8 connections can be used for indoor units.

Branch Boxes All Flare connections Flare connection Outdoor unit side Liquid : 3/8 in. Vapor : 5/8 in. Indoor unit side Large : 1/2 in. Small : 1/4 in. 2 connections from outdoor unit or separation tubes Control box All fittings Including entire flare connection MUST BE INSULATED. 3 sets of connections exit to indoor evaporators Includes adaptors to the refrigerant pipe size for the indoor units Branch Boxes Not a weatherproof enclosure Cannot be mounted outside or in a space above 80% relative humidity May be installed in a storage space that is inside the insulated envelope of the building Factory Insulated Branch Box prevents need for a condensate drain line or a drain pan. Incorrect installation will void warranty and may cause electrical short in board.

ULTRA LOW TEMP SYSTEMS

Heating Units Indoor Units RLS2H XLTH series (Extra-Low-Temperature Heating) AHRI rated up to: 8.8 HSPF and 27.2 SEER ASU Current High SEER (27.2) The condensing units include: Modified base w/ pan heater Pan heater interface relay Special defrost control AGU

Outdoor Temperature MODEL: ASU9RLS2H Actual Heating Capacity Ratings 17,500 11,100 Btu s at 23-15 F Indoor Target Temperature 70 F TC=Btu Copyright 2015 Fujitsu General America, Inc.

9RLS3 series 12RLS3 series 15RLS3 series 9RLS3H series 12RLS3H series 15RLS3H series Replaces the RLS2(H)

World s Most Efficient Heat Pump

COP 5.33 4.64 4.59-5 F

RLS3: Improved Efficiency, Low Temp Heating Heating Capacity is impressive at low outdoor temperatures! High capacity is possible by using larger coils and a high capacity, yet very efficient compressor Operates in Heating down to -5 F Rated heating capacity maintained at 5 F Operates in Cooling down to 14 F RLS3 units are NOT backwards compatible with RLS2 equipment.

Outdoor Temperature - 5 F ASU12RLS3 Indoor Temp TC=Btu 70 F 19,600 15,000 25,300 Btu s at 32-5 59 F

EER SEER Larger heat exchanger (Coil) RLS2 RLS3 Volume Increased 200% Optimized Inverter Control Up 21% Up 20% 33.0 RLS2 RLS3 RLS2 Up 10% RLS3 RLS2 Up 10% RLS3 27.2 Minimum Intermediate Maximum Compressor Speed Percentage of increase may vary by model size 9RLS2 9RLS3 Achieves Super Efficiency

- 15 F H H H 14.0 13.8 13.3 COP 5.33 4.64 4.59

Heating Btuh Output Capacity 22,000 Btu Heat 47 F Nameplate Capacity Comparison 25,000 20,000 Fujitsu 9RLS3H Mitsu MUZ-FH09NA 11,100 Btu Heat -15 F 15,000 10,000 5,000 0 18,000 Btu Heat 47 F 47 F 41 F 32 F 23 F 17 F 5 F -4 F -15 F Outside Dry-Bulb Temperature Low Temperature Comparison 6,084 * Btu Heat -15 F *Estimate based on Mitsu s correction factor and O.D. WB

Without Extra Low Temp Heating Unit may frost up! - Due to continuous low outdoor temperature and high humidity. capacity shortage Noise Freezing of outside parts Decrease the amount of heat exchange Standard model Freezing of machinery room Contact of parts Freezing of base unit Blockage of drain hole * Low outdoor temp. * High humidity

Drain holes X Heater PAN Heater Included! Reduces Rated Efficiency However, competition requires accessory installation! Without a base pan heater ice can build up and crush refrigerant coils, causing expensive repairs. 2015 Fujitsu General America Inc. All Rights Reserved.

COP HSPF Intelligent Base Pan Heater Control 36 F (2 C) Ambient temperature ICY 41 F (5 C) RLS2H OFF Base pan Heater ON OFF Up 25% RLS3H* OFF ON OFF ON OFF ON OFF 11.0 RLS2H RLS3H Up to 10% RLS2H RLS3H Up to 50% Optimum Inverter control RLS2H RLS3H 8.8 Minimum Intermediate Maximum Compressor Speed RLS2H RLS3H RLS3 more efficient - Base pan heater is not on continuously

AOU18RLXFZH Dual Zone AOU24RLXFZH Dual & Tri Zone H H 10.3 10.3 60% Capacity at -15 F 0 SEER ratings up to 16% higher than current models in non-ducted combinations Outdoor temperatures down to -15 F (previous model +5 F)

Single Heat Pump Systems System 18CL System 24CL1 System 30CLX1 System 36CLX1 System 18RLB System 24RLB System 30RLXB System 36RLXB

Single Zone Heat Pump Models! 18RLB 24RLB SEER 19.0 / EER 12.5 / HSPF 10.6 / COP 4.11 SEER 18.0 / EER 10.0 / HSPF 10.6 / COP 3.65 30RLXB 36RLXB SEER 16.5 / EER 9.5 / HSPF 9.0 / COP 3.14 SEER 15.5 / EER 8.5 / HSPF 9.0 / COP 2.94

FEATURES HEATING & COOLING ONLY (OPTION) Need Cooling Only? Function codes can set unit to cooling Only! System 18RLB System 24RLB System 30RLXB System 36RLXB

AOU18RLXFZ AOU24RLXFZ AOU48RLXFZ1

Wire Kit # UTY-XWZX5 Turns system on/off using a normally closed circuit. Interface Kit # UTY-XCBZ2 (Used on: ASU9RLF1) Examples: Home automation or BMS integration of ONLY On/Off operation of Fujitsu system Occupancy Sensor of Key Card Switch Lead-lag control of supplemental heating or cooling Condensate pump alarm circuit Humidistat: turns system On/Off based on humidity, regardless of temperature Outdoor temperature sensor to shut system off and start a third party heating or cooling source Examples: Interface Kit (required to connect a wired or UTY-XWZX) Interface Kit # UTY-XCBXE (For 9RL and 12 RL Systems Only) Examples: Interface Kit (required to connect a wired or UTY-XWZX ) Previous models require a different wire kit. Check installation instructions.

Slim Duct Auto Louver Grill Operates with indoor unit Louvers can be controlled by remote control UP and Down auto swing Fixed airflow with 4 positions or auto swing Auto-closing louver When indoor stops, the louver closes. * Only compatible with ARU models with serial numbers greater than 2000.

Slim Duct Auto Louver Grill Product specifications are subject to change without notice.

Wired Remotes Standard on: Compact Cassette Units Single Large Cassette Units Concealed Ceiling Units Remote Controls Inverter & Multi-zone Wall Mount Wireless Remote A special option allows the user to enable an internal Thermosensor in wired remotes which may enable temperature sensing at the wall instead of in the return of the indoor unit in Most Models. NOTE> This Feature Is Wired Remote Accessories Non Inverter Wireless Remote With Halcyon HFI Wall Mount Wireless Remote Halcyon HFI Wired Central Remote -Works With individual unit remotes.

NE W REMOTE INTERNET MANAGEMENT

Manage remotely your HVAC system using a smart phone, tablet or PC via Internet from anywhere.

Home Owner From: - The Office - The Street - The Gym - Everywhere Internet Home WIFI ROUTER *Home Wi-Fi router is required

FEATURES AND BENEFITS

Automatic Air Direction - Heating Warm Air Rises & Cold Air Sinks Fujitsu Power Diffuser Directs warm air to floor Warm air spreads evenly No cold windy feel like from a traditional heat pump or even a poorly ducted warm air furnace

24RLXS Heating Airflow Airflow diagram over thermal image These charts are in the Design & Technical Manual Outside air conditions:35.6 F 60% Operation mode: Heating, Set temperature (Max set temp) Air flow Hi, Vertical flap : Downward

Please install indoor units so the warm air blows: Down the walls Toward cold areas Make my day and Heat The Room Not The Furniture!

Automatic Air Direction - Cooling Cold air is directed across the ceiling toward the heat causing it to cool your space more quickly and efficiently. Does not blow cold air on room occupants

Please install wall units up high on the wall so the cold air blows above my head. Make my day and Cool The Room Not The People!

ESP Energy Saving Program

ESP Energy Saving Program Fujitsu Halcyon RLS2 and NEW RLS3 systems save you money even if you forget. If you leave the room without turning the unit off, ESP knows that you left When movement is sensed the unit returns to the previous set temperature. ESP prevents wasteful operation to save energy without you having to think about it. Copyright 2015 Fujitsu General America, Inc.

If ESP does not sense movement in 20 minutes, it will set back. Cooling - Temp increases by 4ºF -up to a maximum of 86ºF. Heating Temperature decreases 8ºF down to a minimum of 60 degrees F. Copyright 2015 Fujitsu General America, Inc.

Selectable Feature The ESP Function can be turned on and off Copyright 2015 Fujitsu General America, Inc.