Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

Similar documents
SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

Explosion Proof Speaker, Ringer & Speaker/Ringer

Explosion Proof Speaker, Ringer & Speaker/Ringer

Explosion-proof Duct Heaters

FACT SHEET Program: Lab Fire Safety

Electron Microscopy Sciences

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Explosion Proof Hazardous Location Roof Top A/C Units

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton

VACPB1 Series - 60 Hz Models

VAC1 Series - Division 2 / Zone 2

VAC1 Series-Division 2 / Zone 2

ESD500. ESD500 Combustible / Toxic Gas Detector

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

ESD3000 ESD200 Combustible / Toxic Gas Detector

MERIDIAN UNIVERSAL GAS DETECTOR

Working safely with flammable liquids

Hazardous area descriptions

Fire Alarm System Accessories

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Fire Alarm System Accessories

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

CU-MS & AH-HW Mini-Split Series

1. GENERAL TECHNICAL INFORMATION

Flammable and Combustible Liquids: Storage and Handling

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

Vacuum and Compressor Systems for the Chemical Process Industry

VSD AND SS DRIVING ATEX MOTORS February 2014

ESD3000IR ESD3000IR. Infrared Gas Detector

Overview of Hazardous Locations as They Relate to Solenoid Valves

Flammable and Combustible Liquids Checklist

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR EPH-FH SERIES HEATER

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Explosion protection Marijan Gorše, dipl. ing.

Low mg/m

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

SBS-H2 Hydrogen Gas Detector Kit

Guide for hazardous areas

LFL Monitoring. MEGTEC Systems

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

Shepherd FTIR. Laboratory Quality Results. Continuous, real time portable monitoring of 385 individual species of gas: 100+ HAPs. ...

Tradition & Technology

Implementation of ATEX Guidelines

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Relays for use in hazardous locations. Class I, Division 2 and ATEX

SP-220. Features. Combustible handheld gas leakage detector

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series

Introduction to Hazardous Electrical Location Classifications

APPLICATION DATA SHEET

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Thank You for Attending Today s Webinar:

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR HLA SERIES HEATER

AirSentry FTIR Multi-gas Open Path FTIR Analyzer

Thermo Scientific Flammable Material and Explosion-Proof Refrigerators and Freezers. Safe cold storage for Hazardous material

Smoke detection in hazardous areas:

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

HLA Series Hazardous Location Fan Forced Unit Heater

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Sioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers

Dräger PEX 3000 Flammable Gas Detection

S T R I T T & P R I E B E I N C.

WATER BATH BM100 BM200

Organic Solvent Recovery Unit RT200. Instruction Manual. - First Edition -

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Explosion-protected actuator Page 259 of 292

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

HLA Series Hazardous Location Fan Forced Unit Heater

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

Star Teck. Teck and Tray Cable Fittings. Table of Contents

Specifying Temperature Sensors for Hazardous Areas

Meets Global Standards

Nuclear Electric Heating

ST Explosion Protection GAS DETECTION SYSTEMS

Vapour Control Systems

Dräger Polytron SE Ex Fixed Gas Detector

INSTRUCTION MANUAL Detcon Model FP-524D

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

Ventilating Hazardous Classified Locations. Steve Brandt, P.E. D.F. Brandt, Inc. Isolation Air Systems, Inc.

Model FP-424C ma Combustible Gas Sensor (0-100% LEL) Operator s Installation & Instruction Manual. May 18, 2010 Document #2243T Version 3.

dcyrel Packaging Graphics Products

Beamex Calibration White Paper. Calibration in hazardous areas

INSTRUCTION MANUAL Detcon Model FP-524D-HRT

Technical Committee on Electrical Equipment in Chemical Atmospheres

Detcon MicroSafe. FP-624HT Combustible Gas Sensor (0-100% LEL) Specialized Version For High Temperature Operation of Sensor Head

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Beamex. Calibration White Paper. Calibration in hazardous areas

Early Warning Solutions

CLASS I LOCATIONS ZONE CLASSIFICATION

Installation and Wiring 1.

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

Transcription:

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment. COPYRIGHT 2011 Safe Air Technology LLC. All Rights Reserved

Severe Duty Design for: Safe Air Technology specializes in the engineering and manufacturing of Explosion Proof, Corrosion Resistant HVAC/R systems, and Pressurization Equipment. Our explosion proof, severe duty systems are designed to offer a safe solution at a competitive price while maintaining the highest level of quality in both our systems and services. Safe Air Technology has provided systems of all sizes throughout the world for refineries, chemical plants, offshore platforms, drill ships, FPSO vessels as well as other facilities. Safe Air Technology provides outstanding turn key solutions for the petrochemical market. From explosion proof air conditioners, air filtration systems and pressurization equipment. We have the engineering expertise and production capability to provide turn key solutions for your projects of all sizes. Throughout the world, our explosion proof HVAC solutions are used by some of the leaders in the petrochemical industry. We offer our products, service and support to organizations around the globe so you can focus on production. Our explosion proof HVAC systems give you peace of mind and superior safety through quality engineering and materials. Chemical Plants and Refineries Offshore Platforms Gas Plants and Pipelines Corrosive and Hazardous Storage Facilities Paint Room Ammunition Facilities Fuel Transfer Docks Highly Corrosive Environments Safe Air Technology fully understands your explosion proof HVAC needs are continuously changing. By forging and building a relationship with you, we can continue to provide systems that will meet your needs now and in the future. Safe Air Technology s Headquarters is located in Baton Rouge, La and has offices around the world for efficient communication as well as immediate dispatch to your location when needed.

Safe Air Technology has a Staff of Professional Engineers to support your project. Severe Duty and Explosion Proof HVAC and pressurization systems that can perform safety and reliably within a hazardous and corrosive location begin with experienced and quality engineering. Our professional engineering department has completed projects for both onshore and offshore in more than 30 countries around the world. On the front end of the project, our team can assist with computerized load calculations, building and site surveys, building modeling and leak testing to help assure our customers that the unit designed and built by Safe Air Technology is the correct solution. Safe Air Technology uses 3D design software so the customer can clearly understand the piece of equipment they are purchasing. Our professional engineering team will begin by reviewing your specifications in order to help determine the equipment design needed. All systems are fully tested for both operational performance and compliance to explosion proof codes as requested. Our professional engineering department is well versed and experienced in the specific codes and standards within the petrochemical market such as: ABS, NEC, IEC, ATEX, USCG, IEEE, and NFPA to name a few.

Procurement / Production / Assembly / Testing and Quality Assurance With Over 40,000 Square feet of production space Safe Air Technology has the ability to handle projects of any size. All materials once approved by the quality control officer are brought together in our assembly locations and assembled by highly skilled and trained personal for Safe Air Technology. With systems installed in more than 30 countries around the world all projects undergo our D.E.Q.P. Certification Program. All phases of the project are confirmed in compliance by our professional engineering staff. All Documentation, Engineering, Quality Control and Production of the equipment are certified by our professional engineering department and the documentation issued to our clients for the records. With this time proven and tested method, Safe air Technology is able to supply our systems to the four corners of the Globe knowing that each system is certified for Quality, Performance and Safety meeting all local, national and international standards for our clients.

Installation / Commissioning / Training and Service With procurement of equipment or services from Safe Air Technology, we can offer experienced and professional teams for onsite services and support of your projects on a global scale. Our field service teams travels worldwide to perform many services for our clients. Some are listed below. HVAC/R Field Engineering Services and Design Work Building Modeling and Computer Based Load Calculations Complete HVAC Performance Testing and Certification N.F.P.A. 496 Code Compliance Testing ( National Fire Protection Agency ) Building Pressure Testing and Certification Air Surveys and Air Balancing Testing and Certification No matter the location of your project, our support teams can be dispatched globally to your location to assess your project requirements and equipment in order to evaluate whether any repairs or replacements are needed. Additionally for all systems Safe Air technology offers a full training program detailed around your section to assist with maintaining and operating the systems. We offer remote monitoring of the equipment as an option on selected systems. Please contact Safe Air Technology to set a meeting in order to discuss your projects for specialized explosion proof HVAC systems at the beginning stages. We would be happy to have our professional engineers work with you in order to help you throughout the process of developing a specification to fit your custom needs.

Safe Air Technology Explosion Proof Products Specialized Explosion Proof HVAC/R and Industrial Grade Systems to comply with Our Clients Specifications Offering both Fully Custom and Standard Products Tested for Operational Performance and Certified for use in Hazardous Locations Welcome to the Safe Air Technology products page; please select from the categories below to view the standard explosion proof solutions offered. Should your project specifications require a custom design please contact one of our Sales Engineers for assistance. Remember, our keys to success are: Quality, Pricing, and On-Time Delivery! Our systems are designed to offer a safe solution at a competitive price while maintaining the highest level of quality in both our systems and services. Our in-house Professional Engineering and Manufacturing departments have more than 60 years of experience in designing and manufacturing quality industrial HVAC units and explosion proof HVAC systems that comply with both N.E.C. and I.E.C. codes. Our quality control department provides certified documentation for all projects for code compliance, system performance, and quality assurance. Safe Air Technology fully understands that your needs of today can change quickly. By working together and building our relationship we can continue to meet your needs not only today, but well into the future. We look forward to working with you and in building our relationship.

Window / Thru-Wall Units Safe Air Technology offers a variety of Explosion Proof Window / Thru-wall Units. These systems range from a standard designs, to fully custom designs with capacities ranging from 6,000 to 36,000 BTU/HR with many options available. WCSK Series Window / Thru-Wall Unit Division II and Zone II in Condenser and/or Evaporator 5,500 to 36,000 BTU/HR Cooling Capacity HK Series Window / Thru-Wall Unit Division I and Zone I 7,500 to 36,000 BTU/HR Cooling Capacity WHP Series Window / Thru-Wall Unit Division II and Zone II in Condenser and/or Evaporator 5,500 to 36,000 BTU/HR Cooling Capacity Heat Pump System WCEH Series Window / Thru-Wall Unit Division II and Zone II in Condenser and/or Evaporator 5,500 to 36,000 BTU/HR Cooling Capacity Electric Heat Installed

Root Top Units Safe Air Technology offers a variety of Explosion Proof Rooftop Units. These systems range from modified commercial grade systems to fully custom designs with capacities ranging from 1 to 3 Tons with many options available. RT-XPC Series Roof Top Unit Division II and Zone II in Condenser and/or Evaporator 13,500 and 15,000 BTU/HR Cooling Capacity CSA Third Party Certified RTXP1 Series Roof Top Unit Division 1 and Zone 1 Condenser Section, General Purpose Evaporator Section 13,500 and 15,000 BTU/HR Cooling Capacity Electric Heat Installed CSA Third Party Certified RK-XPC Series Roof Top Unit Division 1 and Zone 1 13,500 and 15,000 BTU/HR Cooling Capacity RTXP2Series Roof Top Unit Division I or II & Zone II or II in Condenser and/or Evaporator 15,000 to 36,000 BTU/HR Cooling Capacity

Vertical / Wall Mounted Units Safe Air Technology offers a variety of Explosion Proof Vertical Package Units. These systems range from modified commercial grade systems to fully custom designs with capacities ranging from 1 to over 25 Tons with many options available. VAC1 Series Vertical Wall Mounted Unit Division II and Zone II in Condenser 12,000 to 72,000 BTU/HR Cooling Capacity CSA Third Party Certified VAC Series Vertical Wall Mounted Unit Division I or II & Zone I or II in Condenser and/or Evaporator 12,000 to 72,000 BTU/HR Cooling Capacity Electric Heat Available VPAC Series Custom Vertical Wall Mounted Unit Division I or II & Zone I or II in Condenser and/or Evaporator 3 to 35 Tons Cooling Capacity

Packaged Units Safe Air Technology offers a variety of Explosion Proof Package Units. These systems range from modified commercial grade systems to fully custom designs with capacities ranging from 1 to over 200 Tons with many options available. PAC Series Packaged Units Division I or II & Zone I or II in Condenser and/or Evaporator 1 to 200 Tons Cooling Capacity Pressurization Units Safe Air Technology offers a variety of Explosion Proof Pressure Blowers. These systems range from 1300 to 20,000 + CFMs and are available in multiple configurations including: base mounted, wall mounted, and roof mounted designs. These systems are available with custom chemical filtration as well as many other options. PB-XPC Series Explosion Proof Pressurization Blower Division I or II & Zone I or II NFPA 496 Compliant 1300 to 20,000 CFM AIR FLOW RATE

Air Conditioning & Pressurization Units Safe Air Technology offers our combination Air Conditioning system with Room Purge and Pressurization system. These combination systems are offered in a variety of standard designs as well as fully custom, including Wall-Mount and Roof or Skid Mounted designs. The capacities range from 1 to over 200 Tons with many options available. VACPB1 Series Vertical Wall Mounted with Pressurization Unit Division II and Zone II NFPA 496 Compliant 12,000 to 72,000 BTU/HR Cooling Capacity Pressurization System Incorporated CSA Third Party Certified PACPB Series Packaged A/C and Room Pressurization Unit Division I or II & Zone I or II in Condenser and/or Evaporator NFPA 496 Compliant 1 to 200 Tons Cooling Capacity Pressurization System Incorporated VPACPB Series Custom Vertical Wall Mounted Pressurization Unit Division I or II & Zone II or II in Condenser and/or Evaporator NFPA 496 Compliant 3 to 35 Tons Cooling Capacity Pressurization System Incorporated

Condensing Units Safe Air Technology offers a variety of Explosion Proof Condensing Units. These systems range from modified commercial grade systems to fully custom designs with capacities ranging from 1 to over 200 Tons with many options available. CU-MS Series MiniSplit Condensing Unit Division I or II & Zone I or II 6,000 to 60,000 BTU/HR Cooling Capacity CU Series Condensing Unit Division I or II & Zone I or II 1 to 200 Tons Cooling Capacity Thermostats Safe Air Technology offers a variety of Explosion Proof Thermostats/Humidistats. These thermostats/humidistats range from a standard designs, to fully custom designs with many options available. TSXP Series Explosion Proof Thermostat Division I or II & Zone I or II Line voltage and control voltage models available

Air Handling Units Safe Air Technology offers a variety of Explosion Proof Air Handling Units. These systems range from modified commercial grade systems to fully custom designs with capacities ranging from 1 to over 200 Tons with many options available. AH-HW- Series MiniSplit Air Handling Unit Division I or II & Zone I or II 0.5 to 5 Tons Cooling Capacity AH-XPC Series Air Handler Unit Division I or II & Zone I or II 1 to 200 Tons Cooling Capacity Exhaust Blowers Safe Air Technology offers a variety of Explosion Proof Exhaust Blowers. These systems range from 100 to 10,000 CFM and are available in both roof and wall mounted designs with many options available. EXBLR-XPC Series Exhaust Blower Division I or II & Zone I or II 100 to 10,000 CFM AIR FLOW RATE

Low Temp Units Safe Air Technology offers a variety of Explosion Proof Unit Coolers for low temperature and medium temperature applications. These systems range from modified commercial grade systems to fully custom systems that fully comply with your specifications. UC-XPC MED / LOW Temp Air Handler Division I or II & Zone II or II Low Temperature Applications Medium Temperature Applications Contact our Sales Department for Capacities CULT-XPC / CUMD-XPC MED / LOW Temp Condensing Unit Division I or II & Zone II or II Low Temperature Applications Medium Temperature Applications Contact our Sales Department for Capacities Cabinet Cooler Units Safe Air Technology offers a variety of Explosion Proof Cabinet Coolers. These systems range from modified commercial grade systems to fully custom designs with capacities ranging from 6,000 to 36,000 BTUs with many options available. CB-XPC Series Cabinet Cooler Division I or II & Zone I or II 6,000 to 60,000 BTU/HR Cooling Capacity

The National Electric Code (ANSI/NFPA 70) The purpose of the (NEC) code is to safeguard persons and property from hazards arising from the use of electricity. Articles 500-517 of the code deal with the installation of electrical equipment in location where explosion or fire hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust, or ignitable fibers. Hazardous Area Classifications The classification of hazardous areas is dependant upon the properties of various hazardous materials and the likelihood of their presence. The NEC designation for Explosion Proof equipment must include a Class, Group and Division. The following tables will help you obtain a better understand of the classifications Classifications for Hazardous Locations Class I Class II Class III A Location where there is a danger of explosion due to the presence of a flammable gas or vapor A location where there is a danger of explosion due to the presence of a flammable dust A location where there is a danger of explosion or flash fire due to a presence of flammable fibers or filings Groups for Classification Class I Class II Class III Groups A,B,C and D Groups E,F and G No Groups Divisions for each Class Division 1 Division 2 A location where an explosive mixture of gas or vapor may exist under normal operating conditions A location where an explosive mixture of gas or vapor may exist under abnormal conditions such as an accidental rupture of a vessel or container or failure of a ventilating system Groups for Gases, Vapors and Dusts Group A 1, 4-dioxane n-propyl ether 1, 2-dichloroethylene methanol (methyl alcohol) styrene acetylene di-n-propylamine tetrahydrofuran 1, 3-dichloropropene methyl acrylate toluene Group B epichlorohydrin triethylamine di-isobutylene methyl amine turpentine formaldehyde (Gas) ethylene valeraldehyde ethane methyl cyclohexane vinyl chloride hydrogen ethyl mercaptan Group D ethanol (ethyl alcohol) methyl ethyl ketone xylenes Group C hydrogen cyanide acetic acid (glacial) ethyl acetate methyl isobutyl ketone Group E acetaldehyde hydrogen seleride acetone ethyle benzene methyl isobutyl ketone Metal Dust includes Aluminum, Commercial Alloys and magnesium allyl alcohol hydrogen sulfide acetonitrile ethyl chloride methyl isocyanate Group F butyl mercaptan isobutyraldehyde acrylonitrile gasoline 2-methyl-1 propanol (isobutyl alcohol) Carbon Black, Coal, Charcoal, Coke Dust n-butyraldehyde methylacetylene Ammonia (2) heptane naphtha (petroleum) Group G Carbon monoxide methyl ether n-amyl acetate heptene nonane Flour, Starch, Grain Dust crotonaldehyde methyl mercaptan sec-amyl acetate hexane nonene dicyclopentadiene monomethyl hydrazine butylamine hexenes Octane & Octene diethyl ether morpholine chlorobenzene isoamyl acetate pentane diethylamine nitroethane cyclohexahe isoprene 1-pentanol (amyl alcohol) dimethyl hydrazine nitromethane cyclohexene isopropyl ether 2 pentanone di-isopropylamine 2-nitropropane cyclopropane LPG (liquefied pet gas) propylene

When a client requires pertinent information for a project, getting it may be a difficult task if the company with the information the client needs is located in another time zone. At Safe Air Technology, we try our best to prevent this or, at the very least, minimize the time it takes our clients to receive vital information for their projects. To accomplish this, Safe Air Technology has established several international offices around the world to better aid our clients in their endeavors. We strive not only to provide excellence in our explosion proof HVAC equipment but in our level of client service as well. Safe Air Technology s international offices are intended to provide support to our clients everywhere without delay. Safe Air Technology s corporate headquarters is located in Baton Rouge, Louisiana of the U.S.A. With two of our international offices located in the Middle East, Far East, Canada, and Latin America. Safe Air Technology has been able to expand to over 30 countries around the world. This is the key to providing accurate and essential information quickly to our clients all over the world. This provides for successful explosion proof HVAC projects. Safe Air Technology United States Safe Air Technology U.A.E. Safe Air Technology Mexico Safe Air Technology Singapore Safe Air Technology Offering The Keys to Success: Quality, Pricing and On Time Delivery 4133 Evan Brooks Road Baton Rouge LA 70814 U.S.A Phone (225) 303-0007 Fax (225) 303-0020 www.explosionproof.net Email: sales@explosionproof.net COPYRIGHT 2010 Safe Air Technology LLC. All Rights Reserved