Dimension drawing. Main feature. Dimension (H x W x D) Cooling capacity *Note. Standalone temperature control. Rated voltage.

Similar documents
HEX200PB Heat Exchanger Instruction Manual

HEX050QA Heat Exchanger Instruction Manual

Specification and Manual

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

TEMPORARY SPECIFICATION FOR REFERENCE

HR150 SERIES DEHYDRATOR USER MANUAL

SEALED ENCLOSURE COOLING

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

SITESTAR CABINET DESCRIPTION

FUNCTIONAL SAFETY MANUAL

STANDARD. Customer : DC FAN. Description : Customer P/N : rev. : N/A X01. Sample issue date : DEC Quantity :

Dual Column Dehydrating Breather Manual

Panel Mounted Heat Exchangers by Dantherm, Inc.

Public Safety DAS Annunciator Panel

MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: "Features

805QS Pressure Switch-Transmitter

SPECIFICATION FOR APPROVAL

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ENCLOSURE COOLING. Glossary

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Wall-Mount Cabinets PROTEK Single-Door and Double-Hinged Cabinets

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Critical Environment Ionizing Blower. Model 5810i. User s Manual

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Table of Content LT 5165-UL

FHS-A9020S01. Application: (Intel Corei7-Per) Picture:

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Installation and Operation Manual Low Power (LP) DC Power System

MODEL NUMBER: SRCOOL60KCW

SPECIFICATION FOR APPROVAL

Tonal Alarms. Sounder Units. Self Cleaning Ports

SEALED ENCLOSURE COOLING

Infrared LED Light - 3 watts - stud mount v - 750nm, 850nm or 940nm

electronics Protection

Installation & Operation Manual For ENERGENICS In-Line Space Saver Lint Filters

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Power to be dissipated (Watts) x 3.17 Maximum Allowable Internal Temperature ( F) - Maximum Ambient Temperature ( F)

Temperature Controllers

SERVICE MANUAL CLASSIC PLUS 26 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT. DocID: 00G00025E

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

SPECTRACOOL Indoor & Outdoor Air Conditioners

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

MBCE-110/230UV Flame Sensor Module

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE- ARRANGMENT.

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

UB20 12V DC. Owner s Manual

FUNCTIONAL SAFETY MANUAL

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

SI 3C LP. 4" Low Profile Back Can. Speakers. n 3" (7.6 cm) full-range driver with a tuned port

NOREN Products. Compact Cabinet Coolers

Life insurance for your electronics

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

USER GUIDE & INSTALLATION INSTRUCTIONS

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Original instructions Sense7-series Non-contact coded safety switch

MBCE-110/230FR Flame Sensor Module

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Model Name: FHS-A6025B01. Application: Intel Nehalem Socket U Xeon (45nm) W5500/X5500/E5500/L5500 CPU sequence. Pictures

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

RECORD SUBMITTAL COVER SHEET

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

RKA-LEL Sample Draw Combustible Gas Detector

AXPR Wall Mounted Axial Panel Fans

SpeedMount Ceiling Speaker System

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

Power. Average noise level (DIN EN ISO 4871)

Delta Electronics Corp. APPROVAL SHEET PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT.

CS 1226T TWO-WAY 70/100 V SPEEDMOUNT CEILING SPEAKER SYSTEM SPEAKER

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Water Leak Detector. Installation and Troubleshooting. Overview

ClimaGuard Outdoor Heat Exchanger All Models

Qualification Test Report LC Duplex Adapter For LC Cutouts

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. I 2017 Pentair Equipment Protection P/N

Window Type Air Conditioner

1.1 Setup Installation

FOT-100. Fiber Optic Temperature Sensor User s Manual P/N: I3A-110

R B10 Series : SMB CARLOCK

Copyright July 2017 Future Products Group Limited. All rights reserved.

Transcription:

External door mount HEX100PC series Dimension drawing Features Main feature Unit Specification IP55 waterproof at external side "One touch" dry run test and dust cleaning Dimension (H x W x D) mm (inch) 690 x 360 x 242 (27 x 14 x 10) Standalone temperature control Cooling capacity *Note W/K (W/ ) 70 (39) 90 (50) Clear LED status indicator Rated voltage VDC 48 Dry contact alarm output Operating current A 1.7 3.6 Opearting power W 82 173 Design Operating voltage range VDC 40 ~ 60 Air to air heat exchange Operating temperature range C -10 ~ +65 Rated voltage at 48V Reduntant fan quantity design High efficiency and reliable fan Easy installation and maintenance Noise (1.5 meter) db-a 65.0 70.0 Weight Kg (Lb) 13 (29) * Note : The cooling capacity (W/K, W/ C or W/ ) is defined as Q/ (TI-TA) Q : Heat dissipation (W) from inside of cabinet TI : Return temperature of internal air circuit (K, C or ) TA : Ambient temperature of external air circuit (K, C or ) * Specifications are subject to change without notice.

HEX100PC Heat Exchanger Instruction Manual

Table of contents 1. Version... 1 2. Description... 1 2-1. General... 1 2-2. Specification... 1 2-3. Environmental condition... 2 3. Installation... 2 3-1. Outline drawing... 2 3-2. Mounting panel cutout and waterproof foam sticking... 3 4. Electrical specification... 3 4-1. Connection and LED indicator (on HEX panel)... 3 4-2. Standalone control mode... 5 5. Mechanical feature... 6 5-1. Thermal path and Airflow baffle... 6 5-2. Configuration... 6 6. Maintenance and Replacement... 7 6-1. Maintenance... 7 6-2. Replacement... 8 7. MTBF and Reliability... 8 7-1. MTBF... 8 7-2. Relibability... 8 8. Safety... 9 9. Accessory... 9 9-1. Power cable... 9 9-2. Function cable... 9 10. General Safety and Warnings... 9

1. Version Rev. Description Drawn Approved Issue date 00 Issue spec. Nick Wang Adam Chen 2016/1/25 01 Add section 10 Nick Wang Adam Chen 2016/6/10 2. Description 2-1. General Delta Heat Exchanger (HEX) is designed for direct air to air heat exchange to remove heat from the cabinet. The internal and the external air circulation loops of the HEX are separated to prevent the introduction of dust, humidity and dirt. The fan on the external air loop conforms to IP55 protection rating. 2-2. Specification Main feature Outline Dimension (H x W x D) Unit mm (in) Model Number HEX100PC 690 x 360 x 242 (27 x 14 x 10) Cooling Capacity (*Note 1) W/K (W/ ) 70 (39) 90 (50) Rated Voltage VDC 48 Rated Current (*Note 2) A 4.2 Operating Voltage Range VDC 40-60 Operating Current A 1.7 3.6 Operating Power Consumption W 82 173 Acoustic Noise at 1.5M (SPL) db-a 65.0 70.0 Weight Kg (Lb) 13 (29) * Note1 : The cooling capacity (W/K, W/ C or W/ ) is defined as Q/ (TI-TA) Q : Heat dissipation (W) from inside of cabinet TI : Return temperature of internal air circuit (K, C or ) TA : Ambient temperature of external air circuit (K, C or ) *Note 2 : Rated current is announcement of safety Page 1

2-3. Environmental condition Description Operating temperature Storage Humidity Ingress protection (on external side)l Specification -10 C ~ +65 C (-14 F ~ 149 F) -40 C ~ +70 C (-40 F ~ 158 F) External air circuit: 0 ~ 100% RH IEC60529 IP55 (NEMA 3) GR-487 720hrs salt spray 3. Installation 3-1. Outline drawing (1) Material : Aluminum sheet t=1.5mm (2) Finish : Power paint, Color RAL7032 (3) Dimensional tolerance : ± 1mm [0.04 ] Page 2

3-2. Mounting panel cutout and waterproof foam sticking : : 4. Electrical specification 4-1. Connection and LED indicator (on HEX panel) Power Connection on panel plate : CVILUX 3W3CS0000100000 mate with : CVILUX 3W3CP0000100000 COMM connection on panel plate : CVILUX CD5115PA100 mate with : CVILUX CD5115SA100 Page 3

User can follow dry contact definition that is Normal Close (N.C.) to detect abnormal status from pin 10 & pin 11 Definition N. C Connection Pin 10 & Pin 11 Control board, NTC and fan are in normal status NTC resistance is over range such as open circuit or short circuit CLOSE OPEN Fan speed is lower than 50% of definition or fan is locked OPEN Dry contact max. rating : 75VDC/50mA LED indicator INNER FAN / OUTER FAN / STATUS LEDs indicate fan and NTC sensor status. Depress "TEST" button to start auto-test of outer and inner fans running from low to high speed. Turn off by depressing the TEST button again. INNER FAN OUTER FAN STATUS Normal GREEN GREEN GREEN Failed* RED RED RED Normal (touch TEST / CLEAN) Blinking GREEN Blinking GREEN N/A Failed* (touch TEST / CLEAN) Blinking RED Blanking RED N/A * FAN failed : Fan speed is lower than 50% of definition or fan is locked * STATUS Failed : NTC resistance is over range such as open circuit or short circuit Page 4

NTC temperature sensor User can switch inner sensor (on control panel) or external sensor (COMM port Pin7 & Pin8 ) via J13 connector on controller as shown below to change sensor location. 4-2. Standalone control mode HEX can detect ambient temperature to control cooling capacity. Internal fan and external fan speed default settings are shown below Cooling capacity (W/K) vs. Temperature Inner fan speed vs. Temperature Outer fan speed vs. Temperature Page 5

5. Mechanical feature 5-1. Thermal path and Airflow baffle With forced convection using the axial fan, warm air generated by the equipment will be blown into the internal return opening and pass though the HEX, then flow out from internal supply opening. The air supply of the cold air will be used to cool down the system; On the opposite side, cooler air from the surrounding environment will be drawn in from the external air inlet side, and push the heat of the HEX out from the external air exhaust side. The thermal exchange path is shown in the figure below. 5-2. Configuration Item Q'ty Description 1 1 Chassis assy 2 4 Fan guard 3 1 Controller 4 2 Internal fan 5 2 External fan 6 1 Heat exchange CORE 7 1 Internal plate assy 8 1 External plate assy Page 6

6. Maintenance and Replacement Be sure to SHUT DOWN the power before proceeding with any maintenance or component replacement. 6-1. Maintenance Monthly Use brush and low pressure air to remove dust or any debris on both internal/external air inlet and air outlet opening. Quarterly Follow below maintenance sequence Internal loop maintenance : * The maintenance is from the internal side. * Use screw driver to remove screw on upper portion of chassis assy (Item 1). * Disassemble the internal plate assy (Item 7) and disconnect fan from controller (Item 3). Note the connection location. * Use brush and low pressure air to remove dust on internal plate assy (Item 7), internal fan (item 4) and heat exchange core opening. * Hold internal plate assy (Item 7) and connect fan to controller (Item 3). * Re-attach internal plate assy (Item 7) and use screw driver to secure screw with chassis assy (Item 1). External loop maintenance : * The maintenance is from the external side. * Use screw driver to remove the screw on bottom portion of chassis assy (Item 1). * Disassemble and hold external plate assy (Item 8), no need to disconnect external fan. * Use brush and low pressure air to remove dust on external plate assy (Item 8), external fan (Item 5) and heat exchange CORE opening. * Re-attach external plate assy back (Item 8) and use screw driver to secure screw with chassis assy (Item 1). Page 7

Test Power on and depress TEST button on panel to proceed with auto test. Follow LED status to check that HEX has resumed to normal function after maintenance. 6-2. Replacement Delta HEX is designed with dry contact alarm output and LED indicator on panel shown below to describe abnormal situation. Refer to Section 4-1 for checking abnormal part is internal fan, external fan or controller for abnormalities. In cases of parts abnormality, Delta will follow the reading and submit spare part(s) below for replacement. Internal fan P/N : AFB1548EH-BJ51 External fan P/N : AFB1548VH-AL1F Controller P/N : HEX100PC-000C User can then refer to maintaince sequence on previous page, or request Delta authorized support for assistance. 7. MTBF and Reliability 7-1. MTBF L10 Fan life is expected to be a minimum 80,000 hours continuous operation at 40 C with 15 ~ 65%RH.@ label rated vo ltage 7-2. Relibability Test item Condition High temperature IEC 60068-2-2 Low temperature IEC 60068-2-1 High temp. / High humidity IEC 60068-2-14 TEST Nb Temperature cycle IEC 60068-2-3 Vibration ETSI 300 019-1-4 CLASS 4.1 Ingress protection (External side) IEC 60529 IP55 (NEMA 3) GR-487 720hrs salt spray Package bump IEC 60068-2-29 Page 8

8. Safety 9. Accessory 9-1. Power cable 9-2. Function cable 10. General Safety and Warnings * Some electronic parts have a high operating temperature. Use caution at all times. * Incorrect installation may cause damage and/or injury. * Installation and maintenance should be performed only by qualified personnel. Use caution at all times. * Ensure the grounding wire is connected before powering on the system. * Ensure the cover and the mounting hardware are secure upon installation. * All the cables connected to the unit must confirm to UL standards. Page 9