AMBIRAD.... Vision Radiant Tube Heating Systems...

Similar documents
VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

AMBIRAD. HEATI NG AND VENTILATION S OLUTIONS... Product Overview... AMBIRAD AIRBLOC NORDAIRNICHE BENSON

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR REZNOR VISION VS RANGE OF RADIANT TUBE HEATERS

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL

RHC GAS FIRED HEATING COILS

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

We offer ceramic radiant heaters and infra-red radiant tubes.

AMBIRAD VISION SCHOOL HEATER KIT INSTALLATION MANUAL

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Introduction. Craig Hale National Sales Manager. Advanced Radiant Systems, Inc. Fishers, IN. Signature Flight Support

Warm air heating equipment

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

Radiant heating equipment

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

RHC & RHCE gas fired heating coils

PT Radiant Heater Range

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

... DF / IDF Gas fired combined heating and ventilation ...

... UDSA - UDSBD Gas fired unit heaters...

BENSON.... Variante3 Fired Unit Heaters...

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

DF-IDF air handling units

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

AMBIRAD AMBIRAD AIRBLOC NORDAIRNICHE BENSON. HEATI NG AND VENTILATION S OLUTIONS... Price List

Gas-fired unit heaters for indoor installation

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

LBF RANGE BALANCED FLUED WATER HEATERS

HERRINGBONE HB COMBINED FLUE SYSTEM

Residential Heating Boilers

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

Heating Systems. An ideal temperature in every pig house

PREEVA air handling unit

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Saving energy comes naturally to us.

IT-KN 7-7 kw. Dimensions. Heat load / Output (kw) 7.0. Angle of installation 15 / 30 / 45 / 60. Gas consumption. natural gas (m 3 /h) 0.

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

THE BURNING ISSUE FOR BODYSHOPS

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

GARAGE / WORKSHOP INFRARED HEATERS

VPC Gas Cabinet Heater Range

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Copper-Fin GAS-FIRED BOILERS

LARGE CAPACITY HEATERS

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

LOWERING THE COST OF HIGH CEILINGS

PC-120 FLATWORK IRONERS. Advanced ironers for superior productivity, efficiency and quality results.

Effective from 1st August Price List

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

G124X - G234X - G334X Atmospheric Gas Boilers

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

Warm Air Central Heating

ELECTRIC HEATERS. Fireball Electric Heaters. 10,200btu HEAT OUTPUT. heating. 30,706btu HEAT OUTPUT. 9,600btu. sales hotline

INSTALLATION GUIDE Dual Fuel Ranges

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

USER S GUIDE FOR PASTA COOKER SERIALS

Efficient heating that won t cost the earth

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

WA & RA EVAPORATIVEE COOLERS INSTRUCTION MANUAL

Studio 3 Steel 2, Glass Fronted with Log-effect fuel bed and Vermiculite lining STUDIO GAS FIRES

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Area Heater AH100 Series

... Autumn. Price Guide Effective 1 st September All prices are ex works. E&OE

BENSON LINEAR RADIANT TUBE

G34M Bulletin #69/ August 2003

INSTALLATION AND OPERATING MANUAL. Vision VS Radiant

Transcription:

AMBIRAD Vision Radiant Tube Heating Systems

* Vision... Radiant Tube Heating Systems... Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has yet again raised the industry standard in terms of innovation and technical performance. * Applicable to certain models only The range of high efficiency Vision radiant tube heaters delivers exceptional performance in terms of efficiency and the potential to reduce energy costs. VSX models 20% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances. Model Range There are three vision ranges: > > The high efficiency VSX range, with recuperative heat exchanger, which is available as a 'U' tube model > > The VS range, complete with stainless steel reflectors and endcaps, is available in 'U' tube, single linear and double linear models and can be mounted in linear or U tube herringbone configurations > > The VSA range, complete with aluminised reflectors and endcaps, which is available in 'U' tube, single linear and double linear models and can be mounted in linear or 'U' tube herringbone configurations Features & Benefits Features: New advanced burner technology > > Choice of burner ratings from 15 to 50kW > > NO x emissions as low as 52ppm on certain models - 40% lower than standard radiant heater > > Combustion occurs entirely within the firing tube. Not only does this reduce the size and weight of the traditional burner control housing but it also helps to reduce noise levels (as quiet as 47 db(a) 3m field) > > New slim-line burner head provides a long evenly distributed flame that dramatically improves temperature distribution along the entire length of the heater, delivering a more even floor coverage > > The inclusion of a recuperative heat exchanger on VSX models (patent P308150GB), mounted adjacent to the burner housing, significantly increases thermal efficiencies up to 91% and enhances radiant efficiency above 65%. > > All units CE approved Benefits: Easy to install and maintain > > On forced gas burner models all electrical wiring is contained at one end of the product, which is particularly time saving when installing single linear (VSLF ) heater models > > All units require straightforward annual maintenance

VS / VSA 'U' Tube VSLF / VSALF Single Linear (forced) VSDL / VSADL Double Linear VSX 'U' Tube... Optimum economy and fuel savings > > The elimination of both distribution and standby losses coupled with high operational efficiencies at the point of use enable fuel savings of up to 65% compared with conventional heating systems > > Excellent radiant performance. More of the available heat generated is distributed to floor level thereby improving efficiency and reducing energy consumption > > High efficiency VSX20 - VSX50 are included on the Government's Energy Technology List and may be eligible for Enhanced Capital Allowances (ECA) Additional control at the touch of a button All models are compatible with AmbiRad SmartCom control systems. SmartCom units incorporate a host of features such as self learning optimised start-up to ensure increased comfort and energy savings. SmartCom 3 control panel Radiant black bulb sensor (Please refer to separate leaflet 'SmartCom Energy Management Control' for full details) increased comfort and energy savings. Herringbone Configuration Herringbone systems are specifically designed to suit individual building requirements; they can incorporate up to ten 'U' tube or linear heaters on one exhaust manifold. The exhaust manifold may be terminated through the roof or wall The particular benefits of herringbone systems are: > > Optimised energy efficiencies > > All units share a common internal flue thereby raising efficiency within the building > > Uniform heat distribution within the space being heated > > Improved aesthetics and minimal risk of water ingress - only one penetration of the building is required to enable the products of combustion to be expelled > > Universal application - they are ideal for both new build and older premises (in particular where penetration of an asbestos roof is an issue)

AMBIRAD Radiant tube heating system Specification VSX model Flueing Units can be installed unflued or individually flued (including concentric flues to minimise building penetrations). Fresh air intake Fresh air can be ducted into the heat exchanger from outside the building to provide clean combustion air, required when there are contaminates in the atmosphere Burner Burner ratings range between 20 and 50kW in 5kW increments. The new burner head located within the firing tube leg provides a very long flame with even heat distribution. NO x emissions are very low - as low as 52ppm on certain models. Heat Exchanger Mounted adjacent to the burner housing. Significantly increases thermal efficiencies up to 91% and enhances radiant efficiency above 65%. Control housing Burner controls are mounted within a chassis that incorporates hinged doors for ease of access for commissioning and maintenance. Tube finish CALCOAT tubes a high technology process that applies a tough, dense, highly emissive surface both inside and out that eliminates the need for painting. As a result CALCOAT ensures a long lasting surface that will not rust or flake, protects welds and maintains the highest of emissivity factors throughout the entire life of the heater.

AMBIRAD Radiant tube heating system Standard radiant heater Vision (VSX) Burner Burner Burner Vision improves temperature distribution along the entire length of the heater. Turbulators Stainless steel spiral turbulators optimise tube temperatures by scrubbing the flue gases against the tube surface, maximising heat transfer and increasing radiant efficiency.

... Radiant Heating Working in the same way as the sun, radiant heat warms all solid objects and surfaces in its path through electromagnetic waves. Being mounted overhead, AmbiRad radiant heaters produce infrared heat that is directed downwards to low level by a reflector. Infrared energy passes inertly through the air, dissipating as heat upon contact with people and surfaces thus creating a comfortable, all-round radiant warmth at lower air temperature. This reduces wasteful heating of empty space and makes substantial energy savings over conventional boiler and air systems. Universal Application Radiant heating has traditionally been predominant in industrial and commercial buildings, especially where there are large, high bay areas or where there are a high number of air changes within the environment. Vision has been developed with these markets in mind and with a view to making radiant heating truly competitive within new smaller industrial and commercial buildings. Its application is universal including environments with high air change, frequently opened doors, or where there is a need for zonal heating in very large premises. Vision Applications > > Aircraft hangars > > Automotive workshops and showrooms > > Factories > > Retail outlets > > Sports arenas and halls > > Warehouses > > Workshops The highly efficient performance of Vision provides greatly reduced running costs and improved capital payback, setting new industry standards. Enhanced Capital Allowances The Government s Enhanced Capital Allowance scheme actively encourages industry and commerce to reduce energy consumption by promoting the use of energy efficient equipment. With radiant efficiencies of above 65% and thermal efficiencies of up to 91% (reducing fossil fuel consumption) a significant number of Vision models are included on the list. This symbol verifies that the product has been independently assessed and qualifies for the ECA scheme, an upfront tax relief enabling businesses that invest in energy-saving equipment to claim 100% first-year capital allowances against their taxable profits.

AMBIRAD Radiant tube heating system - All Models Gas supply Electrical supply Current rating External fuse rating Ignition Connection 1/2 BSP internal thread 230 volt 1 phase 50Hz 1.0 amp max (inductive) 3 amp external Exhaust flue - twin wall diameter 127 mm (5 ) Vision U Tube Models (induced burner) VSUT & VSAUT Electronic programme start up with spark ignition Note: All technical details shown relate to VSUT & VSAUT models except for clearance distances as indicated. VS30UT & VSA30UT not available on LPG (Propane) Model VS15UT4 VS15UT VS20UT VS25UT VS30UT VS35UT VS40UT VS45UT VS50UT Nominal gross heat input kw 15.8 15.0 19.5 23.5 29.5 36.0 40.0 44.0 48.0 Nominal gas rate per burner m 3 /h 1.5 1.4 1.9 2.3 2.8 3.4 3.8 4.2 4.6 Dimensional & weight data Length mm 2219 3417 4142 5066 6029 5709 5709 7471 7471 Overall height mm 235 168 168 168 168 235 235 235 235 Overall width mm 675 500 500 500 500 675 675 675 675 Total installed weight kg 41 43 43 60 70 92 92 121 121 Recommended mounting height range For mounting heights above or below those specified contact AmbiRad design office Horizontal m 4 to 5 4 to 5 4.5 to 7 5 to 8 5.5 to 9 6 to 10 6.5 to 11 7 to 12 7.5 to 13 Inclined / wall mounted m 3.5 to 4.5 3.5 to 4.5 3.5 to 5 4 to 5 4 to 6 4.5 to 6.5 5 to 7 5.5 to 8 6 to 9 Minimum Clearance Distances To Combustible Surfaces Model VS15UT4 VS15UT VS20UT VS25UT VS30UT VS35UT VS40UT VS45UT VS50UT Above reflector VS models with end caps mm All models 180 Above burner & fan assembly flued mm All models 500 Beneath tubes mm 1500 1700 2100 To the sides mm 900 1000 1100 Horizontally from fan outlet unflued mm All models 1200 End of the heater to the wall mm All models 500 Vision Recuperative Heat Exchange U Tube Models (forced burner) VSX Model VSX20 UT2M VSX25 UT2M VSX30 UT2M VSX30 UT3M VSX35 UT3M VSX40 UT3M VSX45 UT3M VSX45 UT4M Nominal gross heat input kw 20.0 25.0 30.0 30.0 36.0 40.0 44.0 44.0 49.5 Nominal gas rate per burner m 3 /h 1.9 2.4 2.9 2.9 3.4 3.8 4.2 4.2 4.7 Dimensional & weight data Length mm 4047 5927 7692 Overall height mm All models 450 Overall width mm All models 746 Total installed weight kg 114 158 205 Recommended mounting height range VSX50 UT4M For mounting heights above or below those specified contact AmbiRad design office Horizontal m 4.5 to 7 5 to 8 5.5 to 9 5.5 to 9 6 to 10 6.5 to 11 7 to 12 7 to 12 7.5 to 13 Inclined / wall mounted m 3.5 to 5 4 to 5 4 to 6 4 to 6 4.5 to 6.5 5 to 7 5.5 to 8 5.5 to 8 6 to 9 MINIMUM CLEARANCE DISTANCES TO COMBUSTIBLE SURFACES Above reflector mm All models 100 Above burner & heat exchanger assembly mm All models 500 Beneath tubes mm 2300 2500 To the sides mm All models 1300 Horizontally from heat exchanger outlet unflued mm All models 1200 End of the heater to the wall mm All models 700

Vision Linear Models (forced burner) VSLF & VSALF Note: All technical details shown relate to VSLF & VSALF models except for clearance distances as indicated. VS30LF not available on LPG (Propane) Model VS15LF VS20LF VS25LF VS30LF VS35LF VS40LF VS45LF VS50LF Nominal gross heat input kw 13.8 19.5 23.5 29.5 36.5 40.0 45.0 50.0 Nominal gas rate per burner m 3 /h 1.3 1.9 2.3 2.8 3.5 3.8 4.3 4.8 Dimensional & weight data Standard length option Nominal metres 6 7 8 10.5 10.5 13.5 13.5 13.5 Total installed standard length weight option kg 43 49 53 72 103 126 126 126 Extended length option Nominal metres 8 10.5 10.5 12.5 13.5 16 16 16 Total installed extended length weight option kg 53 72 72 84 126 147 147 147 Overall height mm 174 235 Overall Width mm 304 470 Recommended mounting height range For mounting heights above or below those specified contact AmbiRad design office Horizontal m 4 to 5 5 to 7 5 to 7 5 to 9 5 to 11 5 to 11 6 to 12 7 to 13 Inclined / wall mounted m 3.5 to 4.5 4 to 5 4 to 5 4 to 6 4 to 7 4 to 7 5 to 8 6 to 9 Minimum Clearance Distance To Combustible Surfaces Above reflector VSLF models with end caps mm All models 150 Above reflector VSLF models no end caps mm All models 280 Above burner mm All models 500 Beneath tubes mm 1500 1700 2100 To the sides mm All models 750 Horizontally from heater outlet unflued mm All models 1200 End of the heater to the wall mm All models 500 Vision Linear Tube Models (induced burner) VSLI & VSALI Note: For all dimensional, weight and clearance details please refer to Vision Linear forced burner section detailed above. VS30LI & VSA30LI not available on LPG (Propane) Model VS15LI VS20LI VS25LI VS30LI VS35LI VS40LI VS45LI VS50LI Nominal gross heat input kw 15.0 19.5 23.5 29.5 36.0 40.0 44.0 50.0 Nominal gas rate per burner m 3 /h 1.4 1.9 2.3 2.8 3.4 3.8 4.2 4.8 Vision Standard Double Linear Models (induced burner) VSDL & VSADL Note: For clearance details please refer to Vision Linear forced burner section detailed above. VS30DL & VS30ADL not available on LPG (Propane) Model VS15DL VS20DL VS25DL VS30DL VS35DL VS40DL VS45DL VS50DL Total nominal gross heat input both burners kw 30.0 39.0 47.0 59.0 72.0 80.0 88.0 100.0 Total nominal gas rate both burners m 3 /h 2.8 3.8 4.6 5.6 6.8 7.6 8.4 9.6 Dimensional & weight data Standard length option Nominal metres 12 14 16 21 21 27 27 27 Total installed standard length weight option kg 86 98 106 144 206 252 252 252 Extended length option Nominal metres 16 21 21 25 27 32 32 32 Total installed extended length weight option kg 106 144 144 168 252 294 294 294 Document reference number: GB/AMB/VS/001/0416 NORTEK GLOBAL HVAC (UK) LTD Fens Pool Avenue Brierley Hill West Midlands DY5 1QA United Kingdom Tel: 01384 489 700 Fax: 01384 489 707 ambiradsales@nortek.com www.ambirad.co.uk Registered in England No. 01390934. Registered office: 10 Norwich Street, London, EC4A 1BD. Nortek Global HVAC is a registered trademark of Nortek Global HVAC Limited. Because of continuous product innovation, Nortek Global HVAC reserves the right to change product specification without due notice.