Control Panel with Across The Line Starters

Similar documents
Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

Variable Frequency Drive SERIES MP800 VFD

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

We ve Got Panels Under Control.

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Pump Station Appliance

MPT Electric Fire Pump Controller

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Lift Station Level Controller

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Lift Station Monitoring & Control The process begins here

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

product brochure Sump, Effluent and Sewage Controls

How to reduce exposure to arc flash hazards

CAUTION & SYMBOL DEFINITIONS:

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Remote Pump Monitoring

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

PRODUCT PRICE BOOK September 4, 2018

Introduction. OM-THA2

Pump-Down Controller MODEL 4052

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Powerohm Resistors Digital HRG System

Annunciation, Remote Monitoring, Control Industrial Control Panels

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

Your Turnkey Solution for Mitigating the Hazards of Arc Flash Incidents in the Workplace

Operation Manual. Programmable Logic Controller

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

PRODUCT PRICE BOOK JUNE 4, 2018

Beacon 800 Gas Monitor Operator s Manual

MPT Electric Fire Pump Controller

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

FTA550 JOCKEY PUMP CONTROLLERS

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Line-Voltage Thermostats

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

SECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN

Safety & Installation Instructions

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Pump-Up Controller MODEL 4062

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

ion Genesis Pump Controller

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual

PRODUCT PRICE BOOK January 1, 2019

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

6/23/ National Electrical Contractors Association and Intec, Inc.

OPERATING INSTRUCTIONS. G214 Software - Version 4

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

VIDEO VISITATION APPLICATION: FUNCTIONS AVAILABLE:

Multiview Monitor / Controller

Power Isolation Solutions. Arc Flash Prevention Starts Here

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex

Owners Manual Operating Instructions Patent # 7,081,811

Dependable Solutions for Gas Detection

MASTER DIESEL FIRE PUMP CONTROLLER

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

THERMAL MANAGEMENT SOLUTIONS

DCS-100. intelligent damper control & monitoring system

EXPERT TRI-STAR. Temperature controller. User s Manual

SmartVFD HVAC and BYPASS

Automation and Energy Efficiency of Industrial Refrigeration Systems

Tri-Stack Smart System

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

IMR IX176 Portable Gas Detector User Manual

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Daikin ENVi Thermostat installation overview

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Bulletin 1608N MiniDySC Dynamic Sag Corrector

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

NFPA 70E Electrical Safety in the Workplace

Arc Flash Protection Training - NFPA 70e Electrical Safety

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

When reliability is vital. Alemite Carbon Shield TM Systems deliver

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

THERMAL MANAGEMENT SOLUTIONS

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

wireless. web-based. worthy of the name RACO.

Utility Battery Chargers DC Power Systems Custom Design

Safety & Installation Instructions

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Transcription:

ECO SMART Station ATL Control Panel with Across The Line Starters The ECO SMART STATION ATL is a pre-engineered duplex control panel designed specifically for municipal lift station applications. Housed in the innovative multiple compartment ARC ARMOR post mount enclosure, the ECO SMART STATION ATL features: Energy View controller Flow measurement Level transducer with 2 float backup Pump monitoring relays (seal fail and over temperature) NEMA rated starters Electronic overload protection Current monitoring and trending Lightning arrestor Terminal blocks Arc Flash An Arc Flash incident in a control panel is an electrical explosion that can occur when there is an uncontrolled conduction of electrical current to ground or another phase. An Arc Flash occurs very rapidly and produces intense heat and energy that can harm personnel and destroy equipment. Patent Pending Enclosure shown mounted to posts With 5-10 arc flash incidents occurring per day, arc flash is a leading cause of death and burn accidents for maintenance staff when servicing electrical control panels in North America today. Onsite damages caused by an arc flash incident include: OSHA citations or fines, down time, loss of revenue and equipment damage. In worst case scenarios, arc flash may result in long term disability or even death, thereby having a significant impact on the liability of the municipality. Arc flash events usually occur in less than 0.2 seconds, and can create: Intense heat Thermo-acoustic shock wave Molten metal Hot shrapnel that can pierce a body Blinding light Toxic smoke Contact with energized components ECO SMART Station ATL p.2

The ECO SMART STATION ATL is housed in the innovative, multiple compartment ARC ARMOR post mount enclosure, reducing the risk of injury resulting from electric shock and exposure to arc flash. The control and power circuitry are isolated in separate compartments, preventing unnecessary operator exposure to high energy circuits and potential arc flash conditions. Zone 1 - Service Compartment Danger Zone: This zone contains the most dangerous arc flash potential and risk of electrical shock. Workers may require Personal Protective Equipment (PPE) when entering. Lockout/Tagout is supported. Zone 2 - MCC Compartment Danger Zone: When zone 1 is energized, workers cannot gain access to zone 2, thereby reducing accidental exposure to arc flash. There is visual indication when power is present in Zone 2. Tagout/Lockout is also supported. Zone 3 - Controls Compartment Operator Safety Zone: Zone 3 contains low voltage circuits only (120 VAC or lower). Minimal PPE is required. For more information on the ARC ARMOR post mount enclosure, visit www.arcarmorenclosure.com. Zone 1 Zone 3 Zone 2 Zone 2 Zone 1 Zone 3 Front View Back View ECO SMART Station ATL p.3

Controller Overview The Energy View Controller is powered by kw Logix Software. The color touch screen HMI has the ability to provide level control, pump alternation, flow monitoring, data logging, alarm logging, historical trending and comes equipped with an SD memory card for data storage and download. It can connect through multiple communication streams for remote monitoring and control. Main Screen Features: 6 inch, color touch screen LED backlit, sunlight readable Intuitive menu navigation Simple setup and operation Continuous level monitoring Flow monitoring (with or without a flow meter) Automatic alternation Pump over temperature and seal fail monitoring Password protection Data logging on SD memory card Intelligent motor protection relay Modbus communication Motor current monitoring and trending High and low current alarms Pump dry run protection * kw Logix is patent pending Level Setup Live Trends ECO SMART Station ATL p.4

Simple The HMI display is very easy to use, intuitive and easy to read in various weather and light conditions, including direct sunlight. Control and Power Options: Battery backup Reduced voltage solid state starter (RVSS) Intrinsically safe barriers for transducer and backup float switches Manual transfer switch with generator inlet Communication Options: I-LINK web-based monitoring system GSM/GPRS cellular modem communication, including: SMS messaging Remote access Dial-up modem (Sixnet) Protocol converter Red Lion model DSPLE Auto dialer Flow Setup Sensor Setup ECO SMART Station ATL p.5

ECO SMART Station ATL Enclosure Overview Overall Dimensions: 36 H x 30 W x 20 D 36 12 18 10 10 20 30 Service and MCC Compartments Front View Controls Compartment Back View Height Width Depth Service Compartment 36 inches 12 inches 10 inches Controls Compartment 36 inches 18 inches 10 inches MCC Compartment 36 inches 30 inches 10 inches ECO SMART Station ATL p.6

ECO SMART Station ATL Ordering Information Part Number 3 Phase, 200V Class Input Voltage* Maximum Motor Amps** Nominal Motor HP*** ECO-ATL-200-S1 (NEMA size 1 starters) 200-208V, 3ph 27 7.5 ECO-ATL-200-S2 (NEMA size 2 starters) 200-208V, 3ph 45 10 ECO-ATL-200-S3 (NEMA size 3 starters) 200-208V, 3ph 90 25 3 Phase, 230V Class ECO-ATL-230-S1 (NEMA size 1 starters) 230-240V, 3ph 27 7.5 ECO-ATL-230-S2 (NEMA size 2 starters) 230-240V, 3ph 45 15 ECO-ATL-230-S3 (NEMA size 3 starters) 230-240V, 3ph 90 30 3 Phase, 460V Class ECO-ATL-460-S1 (NEMA size 1 starters) 460-480V, 3ph 27 10 ECO-ATL-460-S2 (NEMA size 2 starters) 460-480V, 3ph 45 25 ECO-ATL-460-S3 (NEMA size 3 starters) 460-480V, 3ph 90 50 3 Phase, 575V Class ECO-ATL-575-S1 (NEMA size 1 starters) 575-600V, 3ph 27 10 ECO-ATL-575-S2 (NEMA size 2 starters) 575-600V, 3ph 45 25 ECO-ATL-575-S3 (NEMA size 3 starters) 575-600V, 3ph 90 50 Single phase capacitor start models available upon request. *Input Voltage: **Maximum Motor Amps: ***Nominal HP: Match to pump motor nameplate voltage to input voltage and available incoming power at panel site. Motor nameplate Full Load Amps (FLA) must not exceed this value. Based on NEMA B 4 pole motor design. Use for indication only. Actual motor nameplate Full Load Amps (FLA) must be used for selection. Environmental: Elevation: Less than 3,000 ft. If 3,000 ft.>elevation>6,000 ft. de-rate maximum amps by 15%. Rated for outdoor air temperature: 0 o F<Temp.<104 o F. If Temp. <0 o F add MCC heater option. ECO SMART Station ATL p.7

Visit ecosmartpanel.com for more information. We are proud members of these national industry associations: WWW.PRIMEXCONTROLS.COM Ashland, OH 800-363-5842 Clearwater, FL 800-349-1905 Detroit Lakes, MN 888-342-5753 Milford, OH 513-831-9959 2013 SJE-Rhombus Rev 10/13 PRIMEX is a trademark of SJE-Rhombus