FAN WALL Technology. Product

Similar documents
Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Trane Engineers Newsletter Live

Fans: Features and Analysis

Fan Selection. and Energy Savings

Adding More Fan Power Can Be a Good Thing

Fan Arrays. White Paper. Energy Labs White Paper Series Volume 0412 Issue 001 April 2012 Rev. 0. Series

FANWALL TECHNOLOGY. Get the FANWALL. Advantage

Plenum Fans. Model HPA. Direct Drive

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Fan Array Systems WHITE PAPER. Rad Ganesh, PhD, P.E. Director, R&D / Applications Twin City Fan Companies, Ltd. Minneapolis, MN, United States

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

AcoustiFlo Fans: Retrofit Solutions and Beyond

Ducted Propeller. Airflow Volume

Trane Performance Climate Changer Air Handlers. An air handler for every need.

The Current (2017) State of the Art for Air Leakage in Ductwork

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Selecting the Correct Fan

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Glossary of Terms Laboratory & Fume Exhaust Fans

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Introduction to Fans. The Basics of Fan Principles and Terminology

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Trim Pump Impellers. Fredrick/Weinman Engineered Products 2-1/2 KH, 2-1/2 x 3 x 12

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation

TESTS OF ADSIL COATING

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Displacement Ventilation

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Qualification of Fan-Generated Duct Rumble Noise Part 1: Test Facility

Performance Climate Changer Next generation air handler from Trane

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

CHAPTER IV AIR DISTRIBUTION AND BALANCE

Vision and Skyline Semi-custom Air Handlers

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

APPLICATION GUIDE BEAMS

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

Raised Access Floor - (AE Breadth Area)

Sound Performance Rating of Non-ducted Indoor Airconditioning

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

photo by PFC Price Fan Column

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

Variable Refrigerant Flow (VRF) Systems

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

ENGINEERING LETTER 4

Fan Power in 90.1 & IECC

Technical Report Three

1.1 This section applies to air handling units for HVAC Systems.

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

2009 IECC Commercial Mechanical Requirements

Fan Performance and Selection. Overview

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

HVAC Optimization with Cold Air Distribution

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

Best Practices for Condensing Boilers

Understanding Fan System Effects

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Water engineers and utilities are often

Selected Laboratory Energy Efficiency Measures

Agenda and Objectives

SECTION FAN COIL UNITS

Feedback from potential users of UV in HVAC

Ambient (ºF) Temperature Rise Above

Liebert. CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Natatorium Economizer Vs. Conventional Dehumidifier

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

TESTING, ADJUSTING AND BALANCING

COMcheck Software Version Review Mechanical Compliance Certificate

Isolation room exhaust fan noise in a hospital

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Air-Conditioning Buying Guide

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

Modular Active. Chilled. Beams

Evaluation Report 509

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

Transcription:

FAN WALL Technology is a new approach to air handler design using an array of smaller fans to replace a traditional single large fan. FAN WALL Technology This is a fan-array approach to air handler design that provides design flexibility, reduced maintenance costs, and energy savings. Product FAN WALL Technology Manufacturer Huntair, Inc. 11555 S.W. Myslony St. Tualatin, OR 97062 Phone: 503-639-0113 Fax: 503-639-1269 Website: www.huntair.com Distribution Contact in the Northwest Northwest Sales Manager: Kevin Nolan Email: knolan@huntair.com National Sales Manager: Mike Post Email: mpost@huntair.com Other contact information for both of these distributors is the same as the manufacturer. Product Debut in the U.S. March 2003 Product Function and Application According to the Manufacturer FAN WALL Technology is Huntair s name for a new way of assembling custom air handling units using an array of smaller fans to replace a traditional single large fan. This reduces the footprint of the air handler, allows design flexibility, simplifies maintenance, reduces low-frequency noise (rumble) within the air handler, and usually saves energy, for little or no increase in first costs. These air handlers are a niche product used for special applications with stringent requirements for unit size, reliability and noise Page 1

generation. Typical applications include sports stadiums, semiconductor fabrication facilities and concert halls. The custom air handling units they supply using this technology incorporate multiple direct-drive centrifugal plenum fans, assembled in a rectangular array of four to 300+ fans, all discharging into a single plenum. The fans used are specially designed and optimized for use in FAN WALL arrays. Each fan array is usually controlled by a single variable speed drive, which controls the speed of all fans simultaneously. The use of multiple direct-drive fans operating in parallel improves reliability by providing redundancy. Optimized fan wheel construction and improved internal aerodynamics further enhance energy performance. FAN WALL Technology adds an additional control dimension that can significantly reduce energy consumption on highly diversified variable air volume (VAV) systems. In traditional systems, air handlers are designed and specified to perform at a maximum duty point in terms of pressure and air flow, and in most cases the design engineer includes a safety margin in the design. This, coupled with an allowance for highly variable pressure drops due to filter loading over time, will usually result in an installed fan that is very different from what was calculated to meet only the system air-flow requirements. In a traditional system using direct drive motors, it is common to see motor loads at 1/4th to 1/8th of their nameplate rating for a significant portion of their operation hours, resulting in reduced power factors and lower fan and motor efficiencies. To more closely match site conditions, the FAN WALL array can be tuned by turning one or more fans off to allow remaining fans and motors to be fully loaded at or near peak efficiency. Air flow rates can be varied through use of a variable speed drive, by turning fans on and off, or by using both control strategies in combination. The FAN WALL Technology inherently reduces low frequency noise generation, due to the higher tip speed of the smaller diameter fans and their lower mass, which reduces rumble. Additional fan noise reduction is obtained by incorporating coplanar silencers sound-absorbing enclosures built around the four sides of each of the fans in the array that attenuate noise in the mid and higher ranges, because they surround the fans near the source of the noise. Energy Savings Claims Huntair claims that using FAN WALL Technology results in air handling units that are typically 6-10 percent more energy-efficient than similar plenum fan air handlers manufactured by other manufacturers. Some designs fall below this range, and some are higher. These claims are based on the effectiveness of the design features noted above to deliver energy savings through reducing total fan horsepower when compared with other plenum fan air handlers of the same capacity. By incorporating direct-drive fans, they eliminate drive losses, improving mechanical efficiency by as much as 5 percent. Additional efficiency improvements are due to optimizing the width-to-diameter ratio of the fan wheels and to improving aerodynamic performance by eliminating belt guards, large fan pedestals and much of the structure supporting the motors and belt drive mechanism. This allows air to move away from the fan unimpeded. These efficiency gains are somewhat offset by the lower efficiency of the smaller motors compared to the efficiency of the larger motor used in a single-fan air handler. Further reduction in horsepower has been measured in testing (see example in Case Studies section), and is due to the improved air flow characteristics within the plenum resulting from a design which distributes the fan inlets over the face of the plenum. This reduces large pressure gradients across the inlets and outlets of the fans and thus improves the aerodynamics of air flow within the plenum. Page 2

Additional energy savings are realized through a reduction in sound attenuation requirements, as described above under Product Function and Application. Smaller sound attenuators helps keep overall costs low, and the reduction of static pressure losses in the attenuators improves the overall efficiency of the system. The extent of energy savings due to noise reduction is usually small, and depends on the allowable low-frequency sound power levels for a given application. If the designer can reduce the attenuator length from 10ft. to 3ft., for example, they can easily save 0.1 w.g. (water gauge) in static pressure loss for the system, which would save about 0.6 percent in fan energy for a system operating at 2.5 w.g. Non-Energy Benefits Probably the greatest benefit of the FAN WALL design is the layout flexibility gained by reducing the size of the air handler footprint and the plenum fan design. The reduction in footprint is possible because multiple fans of relatively small diameter are spaced across the intake, allowing much shorter inlet and discharge plenums, while maintaining good flow characteristics. Since the fan arrays can be configured in nearly any arrangement, layout flexibility is greatly enhanced. The plenum design allows duct attachment in any of five planes, which further improves layout flexibility compared to single fan systems, which are constrained by the long section of straight duct required at the outlet of a centrifugal fan or axial fan. FAN WALL air handlers can be designed to fit in a space that would be impossible for any other air handling unit. An example from the FAN WALL brochure compares two 200,000 CFM air handlers with coils and filters one using two large directdrive plenum fans in parallel, the other using 33 plenum fans in a 3 x 11 FAN WALL array. The overall dimensions of the first unit are 384 wide x 199 long x 168 high. The FAN WALL air handler measures 348 wide x 120 long x 168 high. This represents a 46 percent reduction in the unit footprint area and unit volume. The length of an air handler incorporating a FAN WALL is also independent of the aspect ratio (height vs. width). This is a tremendous advantage for air handlers that are tall and narrow or flat and wide. This smaller footprint frees up building space that can sometimes be used for more valuable functions. It could also reduce design time for the engineer if floor space is limited, since fitting a large air handler into limited space can be a timeconsuming process. If the value of the floor space that is freed up by the smaller footprint is factored into the cost equation, this can make the first cost of the FAN WALL system equal to or lower than that of a conventional air handling unit, making for an immediate payback. The reduction in required external sound attenuation saves space and installation costs (in addition to energy), and reduces noise for the building occupants. It also eliminates the need for expensive inertial pads and highly massive mechanical room enclosures in all but the most critical sound applications. The data summarized in Figure 1 below are based on tests performed at the Huntair testing facility (and observed by a consulting engineer hired by a customer to ensure that standard testing procedures were performed). The upper line gives the inlet sound power levels at standard octave bands measured for a New York Blower fan. The lower line shows the inlet sound power levels for the FAN WALL Technology unit. (Note: all results expressed in db re: 10 ^-12 watts). 120 100 80 60 Figure 1 Air Handler Sound Power Levels FAN WALL Air Handler New York Blower Plenum Fan 40 63 125 250 500 1000 2000 4000 8000 Octave Band (Hz) Maintenance is simplified by the highly redundant system. The use of many identical fans allows the maintenance department to stock spare motors, bearings and other maintenance items. If one of the fans fails in operation, the variable speed drive Page 3

can compensate by speeding up the remaining fans until a replacement is installed (a power or airflow sensor will send an alarm to the control system to alert maintenance personnel that the motor needs to be replaced). Replacement of the smaller fans is simpler than replacement of a larger unit. The smaller motors are standard offthe-shelf sizes rather than large units that can require several weeks of lead time. In some cases, a single maintenance person can replace a fan without help, whereas a conventional large fan and motor that the array replaces may require a crane. Independent Testing Results Because every FAN WALL is custom-designed, and because the product is so new to the market, we did not find independent testing results. Cost FAN WALL costs are approximately $0.25 per cubic feet per minute of air delivery including installation. This is very close to the cost of a custom air handler utilizing a conventional plenum fan. Alternative Products and Strategies We have not been able to find other innovative approaches to air handlers that give comparable advantages to the FAN WALL. Case Studies The manufacturer provided results from several witnessed tests of FAN WALL air handlers. One example was a FAN WALL air handler consisting of twelve 18-inch diameter fans designed to deliver 55,580 CFM at 8.31 in. w.g. total static pressure (TSP). Tests were run to verify the predicted air moving capabilities, energy consumption and sound power levels. Each of the unit s 12 fans ran at 2,999 RPM and 7.91 brake horsepower (BHP) for a total of 94.9 BHP. In order to compare the relative effectiveness of the FAN WALL design to a conventional air handler, the Washington State University (WSU) Extension Energy Program identified a plenum fan that could replace the array in the example above, and analyzed its performance characteristics. The plenum fan, manufactured by New York Blower, utilizes a 54 diameter fan wheel operating as a class three fan. It assumes no plenum effect and has the same operating point of 55,580 CFM at 8.31 in. w.g. TSP. This fan would require 105 BHP to replace the 94.9 BHP FAN WALL array. However, the larger motor will typically be somewhat more efficient than the smaller motors. Overall, the FAN WALL system should use about 5-6.5 percent less energy than the New York Blower equivalent at this operating point. This comparison does not take into account the FAN WALL energy savings attributable to the reduction in required sound attenuation. These results are consistent with Huntair s energy saving claims. Suggestions for Further Research and Testing Independent testing of several representative configurations of FAN WALL designs would be very helpful in providing unbiased guidance to HVAC system designers. Testing should include flow rate versus total pressure, fan horsepower and sound power ratings. Long term studies evaluating maintenance requirements and reliability would also be useful. Conclusion Many HVAC design engineers who have experienced the challenge of trying to shoe-horn a large fan into a limited space, while allowing room for maintenance access and an outlet with good airflow characteristics, may come to appreciate the advantages of an array of smaller plenum fans. FAN WALL Technology appears to have improved upon the basic design of plenum fans by replacing a single large fan with many smaller ones, reducing the air handler footprint and reducing noise generation, while improving reliability and energy characteristics. This innovation is worth careful consideration in projects that warrant the use of custom air handling units. Page 4

Additional Information Northwest businesses and utilities can contact the EnergyIdeas Clearinghouse for additional information on this or other energy technologies or products. Contact: Phone: 1-800-872-3568 Email: info@energyideas.org Website: www.energyideas.org Reviewer William Kingrey, P.E. WSU Extension Energy Program Date April 2005 (Revised June 2005) Photo Credit The photograph of the typical FAN WALL air handler was provided by, and is used with the permission of, Huntair, Inc. Disclaimer This evaluation/review was based in part upon information provided to us by the manufacturer of the product or service. The evaluation/review does not in any respect constitute an endorsement of the product or services discussed herein. This evaluation/review also does not constitute a guaranty or warranty of any kind that the products or services described herein will perform as described or otherwise. Nothing contained in this evaluation/review may be reproduced, in whole or in part, for marketing purposes or any other purpose, without the express written consent of the Northwest Energy Efficiency Alliance. 2005 WSU Extension Energy Program. WSUEEP05-008 PTR # 10.1 References New York Blower Fan Selection Software Huntair, Inc. acceptance testing results ASHRAE Systems and Equipment Handbook, 2004 Page 5