Rosemount Compact Orifice Flowmeter Series

Similar documents
Rosemount 3051SFC Compact Orifice Flowmeter

Annubar Flowmeter Series

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 3051SFP Proplate Flowmeter

Rosemount Integral Orifice Flowmeter Series

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 3051CFC Compact Flowmeter

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 3051S Series of Instrumentation

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 3051S Series of Instrumentation

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 752 Fieldbus Remote Indicator

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Rosemount 2051CF DP Flowmeters

Rosemount 4500 Hygienic Pressure Transmitter. Start

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 3051 Pressure Transmitter

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 3051CF DP Flowmeters

Rosemount 3051L Level Transmitter

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 702 Wireless Discrete Transmitter

Rosemount 3051 Pressure Transmitter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 8800D Series Vortex Flowmeter

Rosemount 1595 Conditioning Orifice Plate

Rosemount 3051 Pressure Transmitter

Rosemount 2051T In-line Pressure Transmitter

Rosemount 8800D Series Vortex Flowmeter

Rosemount 3051 Pressure Transmitter

Rosemount 3144P Temperature Transmitter

Rosemount 3100 Series Ultrasonic Level Transmitters

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Sanitary Pressure Transmitter

Absolute and Gage Pressure Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 3490 Series

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 848T High Density Temperature Measurement Family

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 3051S MultiVariable Extension Supplement

Rosemount 248 Temperature Transmitter

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 2090F Hygienic Pressure Transmitter

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Rosemount 644 Temperature Transmitter

Rosemount 3144P Temperature Transmitter with HART Protocol

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Rosemount 2160 Wireless Vibrating Fork Level Switch

Rosemount 3051S MultiVariable Transmitter

Rosemount 3144P Temperature Transmitter

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Emerson Wireless SmartPower Solutions

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

Rosemount 8732E Magnetic Flowmeter System with Profibus PA digital fieldbus (Transmitter and Sensor)

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 2120 Vibrating Fork Liquid Level Switch

OPTIBAR DP 7060 Supplementary Instructions

Operating Instructions Edition 02/2007

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series MultiVariable Flowmeter

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Ar-Mite TM Low Flow Armored Flowmeter

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Rosemount 248 Temperature Transmitter

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 2100 Series

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Temperature Measurement Transmitters for field mounting

Rosemount 2088 Absolute and Gage Pressure Transmitter

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Enraf Servo Gauge 854 ATG

Rosemount 248 Temperature Transmitter

Temperature Solutions Line Card

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

FAHM Co. Temperature Transmitter PTT74 Series

Transcription:

Product Data Sheet Reduced installation cost compared to a traditional orifice plate Accurate and repeatable Easy-to-install direct mount assembly Self-centering Based on ASME/ISO corner tap design Patent-pending technology Scalable MultiVariable Transmitter enables pressure, temperature, and fully compensated mass and energy flow WirelessHART capabilities extend the full benefits of PlantWeb to previously inaccessible locations Rosemount 405C Conditioning Orifice Rosemount 3051SFC Compact Orifice Rosemount 3095MFC Flowmeter Compact Orifice Flowmeter Content The Rosemount 405 Compact Orifice Series.................................... page 2 Rosemount Pressure Solutions............................................... page 2 Rosemount 3051SFC Compact Orifice Flowmeter................................ page 4 Specifications...................................................... page 4 Product Certifications............................................... page 12 Dimensional Drawings.............................................. page 19 Ordering Information............................................... page 20 Rosemount 3095MFC Compact Orifice Mass Flowmeter.......................... page 25 Specifications..................................................... page 25 Product Certifications............................................... page 31 Dimensional Drawings.............................................. page 33 Ordering Information............................................... page 34 Rosemount 405 Compact Orifice Primary Element............................... page 37 Specifications..................................................... page 37 Dimensional Drawings.............................................. page 41 Ordering Information............................................... page 43 www.rosemount.com

Product Data Sheet The Rosemount 405 Compact Orifice Series Best-in-Class Integrated DP Flowmeters By integrating Rosemount pressure transmitters with the 405 Compact Orifice Series primary element, Rosemount provides the highest performing DP Flowmeters. This fully integrated flowmeter eliminates the need for fittings, tubing, valves, adapters, manifolds, and mounting brackets, thereby reducing welding and installation time. Less Expensive than an Orifice Plate Installation Direct mounting minimizes total installed cost by reducing engineering, procurement, labor, and material expenditures while offering unsurpassed utility. Rosemount pressure transmitters combined with the Rosemount 405 Compact Orifice create Best-in-Class Flowmeters 405C 3095MFC Compact Orifice Mass Flowmeter Direct Mount A 3-valve isolation manifold and 1-in (25 mm) thick wafer-style body allows direct mounting while eliminating field connections between the process and the differential pressure-measuring device. The integral configuration results in a robust, inexpensive, and easy-to-install assembly. Accurate and Repeatable The 405C Conditioning Orifice is ideal for limited pipe run measurements in gas, liquid, or steam applications (8-in. (200 mm) nominal diameter and smaller lines). The 405C Conditioning Orifice delivers consistent and accurate measurements one would expect from traditional orifice plate technology. Centering Mechanism Improper centering of any orifice type device can cause an error of up to ±5% in small line sizes. A centering mechanism independent of flange rating is standard with the 405 Compact Orifice Series. Based on ASME/ISO Corner Tap Design The incorporation of design features from proven standards results in a product that performs in a predictable manner and operates on well-known principles. Rosemount 3051S Series of Instrumentation Highest performing scalable pressure, flow and level measurement solutions drive better plant efficiency and more productivity. Innovative features include wireless, advanced diagnostics, and multivariable technologies. Rosemount 3095 Mass Flow Transmitter Accurately measures differential pressure, static pressure and process temperature to dynamically calculate fully compensated mass flow. Rosemount 305, 306 and 304 Manifolds Factory-assembled, calibrated and seal-tested transmitter-to-manifold assemblies reduce installation costs. Rosemount 1199 Diaphragm Seals Provides reliable, remote measurements of process pressure and protects the transmitter from hot, corrosive, or viscous fluids. Orifice Plate Primary Element Systems: Rosemount 1495 and 1595 Orifice Plates, 1496 Flange Unions and 1497 Meter Sections A comprehensive offering of orifice plates, flange unions and meter sections that are easy to specify and order. The 1595 Conditioning Orifice provides superior performance in tight fit applications. 405P Rosemount Pressure Solutions 3051SFC Compact Orifice Flowmeter Advanced PlantWeb Functionality Rosemount orifice flowmeters power PlantWeb through a scalable architecture, advanced diagnostics, and MultiVariable capabilities. This reduces operational and maintenance expenditures while improving throughput and utilities management. Rosemount 3051SFA Annubar Flowmeters, Rosemount 3095MFA Annubar Flowmeters, and Rosemount 485 Annubar The state-of-the-art, fifth generation Rosemount 485 Annubar combined with the Rosemount MultiVariable transmitter technology creates an accurate, repeatable and dependable insertion-type flowmeter. Rosemount 3051SFC Compact Orifice Flowmeters, Rosemount 3095MFC Compact Orifice Flowmeters, and Rosemount 405 Compact Orifice Compact Orifice Flowmeters can be installed between existing flanges, up to a Class 600 (PN100) rating. A conditioning orifice plate version offers installation in tight fit applications requiring only two diameters of straight run upstream after a flow disturbance. Rosemount 3051SFP Integral Orifice Flowmeters, Rosemount 3095MFP Integral Orifice Flowmeters, and Rosemount 1195 Integral Orifice These integral orifice flowmeters eliminate the inaccuracies that become more pronounced in small orifice line installations. The completely assembled, ready to install flowmeters reduce cost and simplify installation. 2

Product Data Sheet 405 Compact Orifice Series Selection Guide Rosemount 3051SFC Compact Orifice Flowmeter See ordering information on page 20. Combines the Rosemount 3051S scalable pressure transmitter with the 405 Compact Orifice Primary Utilize the 3051S MultiVariable pressure transmitter for differential pressure, static pressure and process temperature measurement combinations Accuracy up to ±0.55% of mass flow rate Provides superior calculations including fully compensated mass, energy, and totalized flow Accuracy up to ±0.80% of volumetric rate Remote display and interface assembly enables direct mounting with at-grade operator interface FOUNDATION fieldbus protocol available 3051SFC Compact Orifice Flowmeter Rosemount 3095MFC Compact Orifice Flowmeter See ordering information on page 34. Combines the Rosemount 3095MV MultiVariable mass flow transmitter with the 405 Compact Orifice Primary Accuracy up to ±0.70% of mass flow rate Measures differential pressure, static pressure, and process temperature (remotely) all in one flowmeter assembly Dynamically calculates compensated mass flow FOUNDATION fieldbus protocol available 3095MFC Compact Orifice Flowmeter Rosemount 405 Compact Orifice Primary See ordering information on page 43. Integral manifold head allows direct mounting of DP transmitters Accuracy up to ±0.5% of discharge coefficient uncertainty Direct mounting capability to ANSI 600# rating Self-centering alignment ring 405C Conditioning Orifice 405P Compact Orifice 3

Product Data Sheet Rosemount 3051SFC Compact Orifice Flowmeter SPECIFICATIONS Performance System Reference Accuracy Fully-Compensated Mass, Energy, and Actual Volumetric Flow Accuracy Flow performance specifications assume device is configured for full compensation of static pressure, process temperature, density, viscosity, gas expansion, discharge coefficient, and thermal correction variances over a specified operating range. Percent (%) of flow rate Type 3051SFC1C 3051SFC1P (2) 3051SFC1P (4) 3051SFC1P (5) Beta 0.4 0.65 0.4 0.65 (3) Classic MV (1) (8:1 flow turndown) ±0.60% ±1.05% Ultra for Flow (14:1 flow turndown) ±0.55% ±1.00% ±2.30% ±2.25% 0.4 0.65 (3) ±1.80% ±1.75% 0.4 0.65 (3) ±1.30% ±1.25% Repeatability ±0.1% Line Sizes 1 /2-in. (15 mm) not available for the 3051SFC_C 1-in. (25 mm) not available or the 3051SFC_C 1 1 /2-in. (40 mm) not available for the 3051SFC_C 2-in. (50 mm) 3-in. (80 mm) 4-in. (100 mm) Performance Statement Assumptions Measured pipe I.D Sizing Contact an Emerson Process Management representative for assistance. A Configuration Data Sheet is required prior to order for application verification. (1) For a Range 1 DP sensor, add 0.25% uncertainty. (2) Line size of 1 /2-in. (15mm). (3) For 0.65 beta and ReD< 10,000 add an additional 0.5% to the Discharge Coefficient Uncertainty. (4) Line sizes of 1-in. (25,4 mm) and 1 1 /2-in. (38,1 mm). (5) Line size of 2-in. (50,8 mm) and greater. Uncompensated Flow Accuracy Percent (%) of flow rate Type 3051SFCDC 3051SFCDP (1) 3051SFCDP (3) 3051SFCDP (4) Beta 0.4 0.65 0.4 0.65 (2) (1) Line size of 1 /2-in. (15mm). Classic (8:1 flow turndown) ±1.05% ±1.35% Ultra (8:1 flow turndown) ±0.85% ±1.20% Ultra for Flow (14:1 flow turndown) ±0.80% ±1.15% ±2.45% ±2.35% ±2.30% 0.4 0.65 (2) ±2.00% ±1.90% ±1.85% 0.4 0.65 (2) ±1.55% ±1.45% ±1.40% (2) For 0.65 beta and ReD< 10,000 add an additional 0.5% to the Discharge Coefficient Uncertainty. (3) Line sizes of 1-in. (25,4 mm) and 1 1 /2-in. (38,1 mm). (4) Line size of 2-in. (50,8 mm) and greater. 4

Product Data Sheet Functional Service Liquid Gas Steam 4 20 ma/hart Zero and Span Adjustment Zero and span values can be set anywhere within the range. Span must be greater than or equal to the minimum span. Output Two-wire 4 20 ma is user-selectable for linear or square root output. Digital process variable superimposed on 4 20 ma signal, available to any host that conforms to the HART protocol. Power Supply External power supply required. 3051SFC with Measurement Type D (4 20 ma): 10.5 to 42.4 V dc with no load 3051SFC with Measurement Types 1-7: 12 to 42.4 V dc with no load 3051SFC HART Diagnostics transmitter: 12 to 42.4 Vdc with no load Load Limitations Maximum loop resistance is determined by the voltage level of the external power supply, as described by: 3051SFC with Measurement Types 1-7 3051S HART Diagnostics Transmitter (option code DA1) Maximum Loop Resistance = 43.5 * (Power Supply Voltage 12.0) 1322 Load (Ohms) 1000 500 Operating Region 0 12.0 20 30 Voltage (V dc) 42.4 The HART communicator requires a minimum loop resistance of 250Ω for communication. 3051SFC with Measurement Type D Maximum Loop Resistance = 43.5 * (Power Supply Voltage 10.5) 1387 Load (Ohms) 1000 500 Operating Region 0 10.5 20 30 Voltage (V dc) 42.4 The HART communicator requires a minimum loop resistance of 250Ω for communication. ASP Diagnostics Suite for HART (3051SFC with Measurement Type D and option DA1) The 3051S provides Abnormal Situation Prevention indication for a breakthrough in diagnostic capability. The 3051S ASP Diagnostics Suite for HART includes Statistical Process Monitoring (SPM), variable logging with time stamp and advanced process alerts. The enhanced EDDL graphic display provides an intuitive and user-friendly interface to better visualize these diagnostics. The integral SPM technology calculates the mean and standard deviation of the process variable 22 times per second and makes them available to the user. The 3051S uses these values and highly flexible configuration options for customization to detect many user-defined or application specific abnormal situations (e.g. detecting plugged impulse lines and fluid composition change). Variable logging with time stamp and advanced process alerts capture valuable process and sensor data to enable quick troubleshooting of application and installation issues. FOUNDATION fieldbus (3051SFC with Measurement Type D) Power Supply External power supply required; transmitters operate on 9.0 to 32.0 V dc transmitter terminal voltage. Current Draw 17.5 ma for all configurations (including LCD display option) FOUNDATION fieldbus Parameters Schedule Entries 14 (max.) Links 30 (max.) Virtual Communications Relationships (VCR) 20 (max.) Standard Function Blocks Resource Block Contains hardware, electronics, and diagnostic information. Transducer Block Contains actual sensor measurement data including the sensor diagnostics and the ability to trim the pressure sensor or recall factory defaults. LCD Block Configures the local display. 2 Analog Input Blocks Processes the measurements for input into other function blocks. The output value is in engineering or custom units and contains a status indicating measurement quality. PID Block with Auto-tune Contains all logic to perform PID control in the field including cascade and feedforward. Auto-tune capability allows for superior tuning for optimized control performance. Backup Link Active Scheduler (LAS) The transmitter can function as a Link Active Scheduler if the current link master device fails or is removed from the segment. Software Upgrade in the Field Software for the 3051S with FOUNDATION fieldbus is easy to upgrade in the field using the FOUNDATION fieldbus Common Device Software Download procedure. 5

Product Data Sheet PlantWeb Alerts Enable the full power of the PlantWeb digital architecture by diagnosing instrumentation issues, communicating advisory, maintenance, and failure details, and recommending a solution. Advanced Control Function Block Suite (Option Code A01) Input Selector Block Selects between inputs and generates an output using specific selection strategies such as minimum, maximum, midpoint, average, or first good. Arithmetic Block Provides pre-defined application-based equations including flow with partial density compensation, electronic remote seals, hydrostatic tank gauging, ratio control and others. Signal Characterizer Block Characterizes or approximates any function that defines an input/output relationship by configuring up to twenty X, Y coordinates. The block interpolates an output value for a given input value using the curve defined by the configured coordinates. Integrator Bock Compares the integrated or accumulated value from one or two variables to pre-trip and trip limits and generates discrete output signals when the limits are reached. This block is useful for calculating total flow, total mass, or volume over time. Output Splitter Block Splits the output of one PID or other control block so that the PID will control two valves or other actuators. Control Selector Block Selects one of up to three inputs (highest, middle, or lowest) that are normally connected to the outputs of PID or other control function blocks. Block Execution Time Resource - Transducer - LCD Block - Analog Input 1, 2 20 milliseconds PID with Auto-tune 35 milliseconds Input Selector 20 milliseconds Arithmetic 20 milliseconds Signal Characterizer 20 milliseconds Integrator 20 milliseconds Output Splitter 20 milliseconds Control Selector 20 milliseconds Fully Compensated Mass Flow Block (Option Code H01) Calculates fully compensated mass flow based on differential pressure with external process pressure and temperature measurements over the fieldbus segment. Configuration for the mass flow calculation is easily accomplished using the Rosemount Engineering Assistant. ASP Diagnostics Suite for FOUNDATION fieldbus (Option Code D01) The 3051S ASP Diagnostics Suite for FOUNDATION fieldbus provides Abnormal Situation Prevention indication and enhanced EDDL graphic displays for easy visual analysis. The integral Statistical Process Monitoring (SPM) technology calculates the mean and standard deviation of the process variable 22 times per second and makes them available to the user. The 3051S uses these values and highly flexible configuration options for customization to detect many user-defined or application specific abnormal situations (e.g. detecting plugged impulse lines and fluid composition change). Wireless Self-Organizing Networks (3051SFC with Measurement Type D only) Output WirelessHART, 2.4 GHz DSSS. Wireless, 2.4 GHz DSSS or 900 MHz FHSS. Local Display (WirelessHART only) The optional five-digit LCD can display user-selectable information such as primary variable in engineering units, percent of range, sensor module temperature, and electronics temperature. Display updates at up to once per minute. Local Display The optional five-digit LCD can display primary variable in engineering units. Display updates at update rate up to once per minute. Update Rate WirelessHART, user selectable 8 sec. to 60 min. Wireless, user selectable 15 sec. to 60 min. Power Module (WirelessHART only) Field replaceable, keyed connection eliminates the risk of incorrect installation, Intrinsically Safe Lithium-thionyl chloride Power Module with polybutadine terephthalate (PBT) enclosure. Ten-year life at one minute update rate. (1) (1) Reference conditions are 70 F (21 C), and routing data for three additional network devices. NOTE: Continuous exposure to ambient temperature limits of -40 F or 185 F (-40 C or 85 C) may reduce specified life by less than 20 percent. Power Module Field replaceable, keyed connection eliminates the risk of incorrect installation, Intrinsically Safe Lithium-thionyl chloride Power Module with polybutadine terephthalate (PBT) enclosure. Five-year life at one minute update rate, ten-year life at ten minute update rate. (1) (1) Reference conditions are 70 F (21 C), and routing data for three additional network devices. NOTE: Continuous exposure to ambient temperature limits of -40 F or 185 F (-40 C or 85 C) may reduce specified life by less than 20 percent. Differential Pressure Limits Maximum differential pressure (DP) up to 800 inh 2 O. Pressure Limits (1) Direct Mount Electronics Pressure retention per ANSI B16.5 600# or DIN PN (1) Static pressure selection may affect pressure limitations. 6

Product Data Sheet Static Pressure Limit 3051SFC with Measurement Types 3, 4, 7, and D Operates within specifications between static line pressures of 0.5 psia and 3626 psig; 4500 psig (310,3 bar) for option code P9 6092 psig (420 bar) for option code P0 (Classic only) Range 1: 0.5 psia to 2000 psig (0,03 to137,90 bar) 3051SFC with Measurement Types 1, 2, 5, and 6 Operates within 0.5 psia (0,03 bar) and the values in the table below: Static Pressure Range D, J GP/AP Range E, K GP/AP Burst Pressure Limits Coplanar or traditional process flange 10000 psig (689,5 bar). Overpressure Limits Transmitters withstand the following limits without damage: 3051SFC with Measurement Types 3, 4, 7, and D Range 1: 2000 psig (137,9 bar) Ranges 2 3: 3626 psig (250,0 bar) 3051SFC with Measurement Types 1, 2, 5, and 6 Static Pressure Range D, J GP/AP Range E, K GP/AP Flowmeter Overpressure Limits (1) Standard (1) Process Temperature Limits Direct Mount Transmitter -40 to 450 F (-40 to 232 C) Remote Mount Transmitter Differential Pressure Range 1 Range 2 Range 3 800 psi (57,91 bar) 2000 psi (137,9 bar) 800 psi (57,91 bar) 3626 psi (250 bar) Differential Pressure -148 to 850 F (-100 to 454 C) Stainless Steel 800 psi (57,91 bar) 3626 psi (250 bar) Range 1 Range 2 Range 3 1600 psi (110,3 bar) 2000 psi (137,9 bar) Type 1600 psi (110,3 bar) 3626 psi (250 bar) Carbon Steel Rating 1600 psi (110,3 bar) 3626 psi (250 bar) Stainless Steel Rating ANSI/ASME Class 150 285 (20) 275 (19) ANSI/ASME Class 300 740 (51) 720 (50) ANSI/ASME Class 600 1480 (102) 1440 (99) At 100 F (38 C), the rating decreases with increasing temperature. DIN PN 10/40 580 (40) 580 (40) DIN PN 10/16 232 (16) 232 (16) DIN PN 25/40 580 (40) 580 (40) At 248 F (120 C), the rating decreases with increasing temperature. (1) Carbon Steel and Stainless Steel Ratings are measured in psig (bar). Transmitter Temperature Limits Ambient 40 to 185 F ( 40 to 85 C) With LCD display (1) : 40 to 175 F ( 40 to 80 C) With option code P0: 4 to 185 F ( 20 to 85 C) With Inert Fill (2) : 0 to 185 F (-17 to 85 C) (1) LCD display may not be readable and LCD updates will be slower at temperatures below -4 F (-20 C). (2) Inert fill temperature limits only apply to 3051SFC with Measurement Types 1, 2, 5, and 6. Storage 50 to 230 F ( 46 to 110 C) With LCD display: 40 to 185 F ( 40 to 85 C) With wireless output (code X): 40 to 185 F ( 40 to 85 C) With Inert Fill (1) : 0 to 185 F (-17 to 85 C) (1) Inert fill temperature limits only apply to 3051SFC with Measurement Types 1, 2, 5, and 6. Vibration Limits Qualified per IEC61298-3 (1998) for field with high vibration level or pipeline with high vibration level (10-60Hz 0.21mm displacement peak amplitude / 60-500Hz 3g). The weight and length of the transmitter assembly shall not exceed 5.8 lbs and 7.75-in. Humidity Limits 0 100% relative humidity Turn-On Time Performance within specifications less than 5 seconds for 3051SFC with Measurement Types 1-7 and 2 seconds for 3051SFC with Measurement Type D (typical) after power is applied to the transmitter. Damping Analog output response to a step change is user-selectable from 0 to 60 seconds for one time constant. For 3051SFC with measurement types 1-7, differential pressure (DP), static pressure (AP/GP), process temperature (PT), Mass Flow, and Energy Flow can be individually adjusted. This software damping is in addition to sensor module response time. Failure Mode Alarm HART 4-20mA (output option code A) If self-diagnostics detect a gross transmitter failure, the analog signal will be driven offscale to alert the user. Rosemount standard (default), NAMUR, and custom alarm levels are available (see Table 1). High or low alarm signal is software-selectable or hardware-selectable via the optional switch (option D1). TABLE 1. Alarm Configuration High Alarm Low Alarm Default 21.75 ma 3.75 ma NAMUR compliant (1) 22.5 ma 3.6 ma Custom levels (2)(3) 20.2-23.0 ma 3.6-3.8 ma (1) Analog output levels are compliant with NAMUR recommendation NE 43, see option codes C4 or C5. (2) Low alarm must be 0.1 ma less than low saturation and high alarm must be 0.1 ma greater than high saturation. (3) Not available with the SIS Safety Transmitter (option QT). 7

Product Data Sheet Safety-Certified Transmitter Failure Values (3051SFC with Measurement Type D Only) Safety accuracy: 2.0% (1) Safety response time: 1.5 seconds (1) A 2% variation of the transmitter ma output is allowed before a safety trip. Trip values in the DCS or safety logic solver should be derated by 2%. Dynamic Performance (1) (1) Total Response Time (Td + Tc) (5) 3051SFC with Measurement Types 1-7: DP Range 1: DP Range 2: DP Range 3: AP & GP: Type D (6) : DP Ranges 2-3: DP Range 1: Dead Time (Td) 3051SFC with Measurement Types 1-7: DP: AP & GP: Type D (7) : DP: Types 1, 3, 5, and 7 only: Process Temp RTD Interface: Update Rate 3051SFC with Measurement Types 1-7: DP: Type D: DP: Types 1, 2, 5, and 6 only: AP & GP: Types 1, 3, 5, and 7 only: Process Temp RTD Interface: Types 1-4 Calculated Variables: Mass or Volumetric Flow Rate: Energy Flow Rate: Totalized Flow: 4-20 ma (HART) (2) 310 milliseconds 170 milliseconds 155 milliseconds 240 milliseconds 100 milliseconds 255 milliseconds 100 milliseconds 140 milliseconds 45 milliseconds (nominal) 1 second 22 times per second 22 times per second 11 times per second 1 time per second 22 times per second 22 times per second 1 time per second Fieldbus protocol (3)(4) 152 milliseconds 307 milliseconds 97 milliseconds 22 times per second Typical Transmitter Response Time Pressure Released 100% 36.8% 0% Transmitter Output vs. Time T d T c Time T d = Dead Time T c = Time Constant Response Time = T d +T c 63.2% of Total Step Change (1) Does not apply to wireless output code X. See Wireless Self-Organizing Networks (3051SFC with Measurement Type D only) on page 6 for wireless transmit rate. (2) Dead time and update rate apply to all models and ranges; analog output only (3) Transmitter fieldbus output only, segment macro-cycle not included. (4) FOUNDATION fieldbus not applicable with 3051SFC with Measurement Types 1-7. (5) Nominal total response time at 75 F (24 C) reference conditions. (6) For option code DA1, add 45 milliseconds (nominal) to 4-20 ma (HART) total response time values. (7) For option code DA1, dead time (Td) is 90 milliseconds (nominal). 8

Product Data Sheet Physical Temperature Measurement Remote RTD 100 Ohm platinum with 1 /2-in. NPT nipple and union (078 series with Rosemount 644 housing) Model 0078D21N00A025T32Ex Connection Head: 00644-4410-0011 Standard RTD cable is shielded armored cable, length is 12 feet (3.66 m) Thermowell with Remote RTD 1 /2-in. x 1 /2-in. NPT, 316 SST Electronic Connections for Remote Mount 1 /2 14 NPT, G 1 /2, and M20 1.5 (CM20) conduit. HART interface connections fixed to terminal block for output code A Material of Construction Body/Plate 316 SST 50 micro-inch Ra surface finish Manifold Head/Valves 316 SST Flange Studs and Nuts Customer supplied Available as a spare part Transmitter Connection Studs and Nuts Studs A193 Grade B8M. Nuts A194 Grade 8M. Gasket and O-rings Gaskets are customer supplied. Durlon 8500 fiber gaskets are recommended. Consult an Emerson Process Management representative for use with other gaskets. Available as a spare part NOTE Gaskets and O-rings must be replaced when the 405 is disassembled. Process-Wetted Parts Integral Manifolds / Remote Manifolds 316 SST Process Isolating Diaphragms 316L SST (UNS S31603) Alloy C-276 (UNS N10276) Drain/Vent Valves 316 SST, Alloy C-276, or Alloy 400/K-500 material (Drain vent seat: Alloy 400, Drain vent stem: Alloy K-500) Process Flanges and Adapters Plated carbon steel SST: CF-8M (Cast 316 SST) per ASTM A743 Cast C-276: CW-12MW per ASTM A494 Cast Alloy 400: M-30C per ASTM A494 Wetted O-rings Glass-filled PTFE (Graphite-filled PTFE with Isolating Diaphragm code 6) Non-Wetted Parts Electronics Housing Low-copper aluminum alloy or SST: CF-3M (Cast 316L SST) or CF-8M (Cast 316 SST) NEMA 4X, IP 66, IP 68 (66 ft (20 m) for 168 hours) Note: IP 68 not available with Wireless Output Coplanar Sensor Module Housing SST: CF-3M (Cast 316L SST) Sensor Module Fill Fluid Silicone or inert halocarbon (Inert is not available with 3051S_CA). In-Line series uses Fluorinert FC-43. Sensor mounting (including nuts, bolts, and gasket) SST Bolts CS Paint Polyurethane Cover O-rings Buna-N Wireless Antenna PBT/ polycarbonate (PC) integrated omnidirectional antenna Power Module Field replaceable, keyed connection eliminates the risk of incorrect installation, Intrinsically Safe Lithium-thionyl chloride Power Module with PBT enclosure Transmitter Connections Remote Mount Available with 1 /4-in. (standard) or 1 /2-in. (option code E) connections Orifice Type Square edged Corner tapped Concentric Wafer-style 9

Product Data Sheet Process Connections Mounts between the following flange configurations: ASME B16.5 (ANSI) DIN JIS Class 150 Class 300 Class 600 PN16 (option code G) PN40 (option code H) PN100 (option code H) 10k (option code B) 20k (option code R) 40k (option code S) ANSI alignment ring is included as standard when ordering. Typical Orifice Hole Sizes (For 3051SFC_C) Beta is calculated by: (β) = d C / Pipe ID, where the calculated bore is equal to 2 x typical orifice hole size (d C = 2d). The table below shows the diameter of each of the four typical orifice holes. TABLE 2. β = 0.4 (1) Line Size 3051SFC_C 3051SFC_P 1 /2-in. (15 mm) Not Available 0.249 (6.325) 1-in. (25 mm) Not Available 0.420 (10.668) 1 1 /2-in. (40 mm) Not Available 0.644 (16.358) 2-in. (50 mm) 0.413 (10.490) 0.827 (21.006) 3-in. (80 mm) 0.614 (15.596) 1.227 (31.166) 4-in. (100 mm) 0.805 (20.447) 1.610 (40.894) (1) Tolerance = ±0.002-in. TABLE 3. β = 0.65 (1)(2) Line Size 3051SFC_C 3051SFC_P 1 /2-in. (15 mm) Not Available 0.404 (10.262) 1-in. (25 mm) Not Available 0.682 (17.323) 1 1 /2-in. (40 mm) Not Available 1.047 (26.594) 2-in. (50 mm) 0.620 (15.748) (3) 1.344 (34.138) 3-in. (80 mm) 0.997 (25.324) 1.994 (50.648) 4-in. (100 mm) 1.308 (33.223) 2.617 (66.472) (1) Measurement is in inches (millimeters) (2) Tolerance = ±0.002-in. (3) Beta (β) = 0.60-in. (15.24 mm) for 2-in. line size only. Weight Line Size Direct Mount (D3) (1) Remote Mount (R3) (1) 1 /2-in. (15 mm) 11.20 (5.08) 8.0 (3.63) 1-in. (25 mm) 11.70 (5.31) 8.5 (3.86) 1 1 /2-in. (40 mm) 12.45 (5.65) 9.25 (4.20) 2-in. (50 mm) 13.20 (5.99) 10.0 (4.54) 3-in. (80 mm) 13.95 (6.32) 11.75 (5.33) 4-in. (100 mm) 14.95 (6.78) 13.5 (6.12) (1) Measurement in lb (kg). 10

Product Data Sheet Installation Considerations Straight Run Requirements TABLE 4. 3051SFC_C Straight Pipe Requirements (1) Beta 0.40 0.65 Upstream (inlet) side of primary Reducer (1 line size) 2 2 Single 90 bend or tee 2 2 Two or more 90 bends in the same 2 2 plane Two or more 90 bends in different plane 2 2 Up to 10 of swirl 2 2 Butterfly valve (75% to 100% open) 2 N/A Downstream (outlet) side of primary 2 2 TABLE 5. 3051SFC_P Straight Pipe Requirements (1)(2)(3) Beta 0.40 0.65 Reducer (1 line size) 5 12 (2)(3) Single 90 bend or tee 16 44 Two or more 90 bends 10 44 in the same plane Upstream (inlet) side of primary Two or more 90 bends in different plane 50 60 Expander 12 28 Ball / Gate valve fully open 12 18 Downstream (outlet) side of primary 6 7 (1) Consult an Emerson Process Management representative if disturbance is not listed. Flowmeter Orientation Flowmeter orientation for both 3051SFC Conditioning Compact Orifice and Standard Compact Orifice. 30 50 Gas (Horizontal) Liquid and Steam (Horizontal) 80 120 50 30 (2) Recommended lengths represented in pipe diameters per ISO 5167. (3) Refer to ISO 5167 for recommended lengths when using flow straighteners. Pipe Orientation Pipe orientation for both 3051SFC_C Compact Conditioning and standard 3051SFC_P Compact Orifice. Process (1) Orientation/ Flow Direction Gas Liquid Steam Horizontal D/R D/R D/R Vertical Up R D/R R Vertical Down D/R NR NR (1) D = Direct mount acceptable (recommended) R = Remote mount acceptable NR = Not recommended Pipe Centering Improper centering of any orifice type device can cause an error of up to ±5% in small line sizes. A centering mechanism (centering ring) independent of flange rating comes standard with the 405 Compact Orifice Series. 3051SFC_C Conditioning Orifice 3051SFC_P Compact Orifice FLOW Gas (Vertical) 360 Liquid (Vertical) 360 FLOW 11

Product Data Sheet Rosemount 3051SFC with Measurement Types 1-7 Certifications Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co., LTD Beijing, China Ordinary Location Certification for FM As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Models with Differential Pressure Ranges = 2 to 5 inclusive with Static Pressure = Range 4 only. P9 and P0 options also. All other Model 3051SMV Pressure Transmitters Sound Engineering Practice Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold Sound Engineering Practice Primary Elements, Flowmeter See appropriate Primary Element QIG Electro Magnetic Compatibility (EMC) (2004/108/EC) EN 61326-1:2006 and EN 61326-2-3:2006 Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-proof for Class I, Division 1, Groups B, C, and D; dust-ignition proof for Class II and Class III, Division 1, Groups E, F, and G; hazardous locations; enclosure Type 4X, conduit seal not required. I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1; Class I, Zone 0 AEx ia IIC when connected in accordance with Rosemount drawing 03151-1206; Non-incendive for Class I, Division 2, Groups A, B, C, and D Enclosure Type 4X For entity parameters see control drawing 03151-1206. Canadian Standards Association (CSA) All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003. E6 Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust-Ignition-Proof for Class II and Class III, Division 1, Groups E, F, and G; suitable for Class I, Division 2, Groups A, B, C, and D, CSA Enclosure Type 4X; conduit seal not required. I6 Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings 03151-1207; For entity parameters see control drawing 03151-1207. European Certifications I1 ATEX Intrinsic Safety Certificate No.: 08ATEX0064X II 1G Ex ia IIC T4 (T a = -60 C to 70 C) -HART 1180 Input Parameters Loop / Power Groups U i = 30 V HART I i = 300 ma HART P i = 1.0 W HART C i = 14.8 nf HART L i = 0 HART Special conditions for safe use (x) The apparatus is not capable of withstanding the 500V test as defined in Clause 6.3.12 of EN 60079-11. This must be considered during installation. N1 ATEX Type n Certificate No.: Baseefa 08ATEX0065X Ex na nl IIC T4 (T a = -40 C TO 70 C) Ui = 45 Vdc max IP66 II 3 G Special conditions for safe use (x) The apparatus is not capable of withstanding the 500V insulation test required by Clause 6.8.1 of EN 60079-15. This must be taken into account when installing the apparatus. ND ATEX Dust Certificate No.: BAS01ATEX1303X II 1 D T105 C (-20 C T amb 85 C) V max = 42.4 volts max A = 24 ma IP66 1180 12

Product Data Sheet Special conditions for safe use (x) 1. The user must ensure that the maximum rated voltage and current (42.4 volts, 22 milliampere, DC) are not exceeded. All connections to other apparatus or associated apparatus shall have control over this voltage and current equivalent to a category ib circuit according to EN 60079-11. 2. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP66. 3. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact test. 5. The 3051SMV must be securely screwed in place to maintain the ingress protection of the enclosure. (The 3051SMV SuperModule must be properly assembled to the 3051SMV housing to maintain ingress protection.) E1 ATEX Flameproof Certificate No.: KEMA 00ATEX2143X Ex d IIC T6 (-50 C T amb 65 C) Ex d IIC T5 (-50 C T amb 80 C) V max = 42.4V 1180 II 1/2 G Special conditions for safe use (x) 1. Appropriate ex d blanking plugs, cable glands, and wiring needs to be suitable for a temperature of 90 C. 2. This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for maintenance shall be followed in detail to assure safety during its expected lifetime. 3. The 3051SMV does not comply with the requirements of IEC 60079-1 Clause 5.2, Table 2 for all joints. Contact Emerson Process Management for information on the dimensions of flameproof joints. Japanese Certifications E4 I4 TIIS Flameproof Consult factory for availability TIIS Intrinsically Safe Consult factory for availability China (NEPSI) Certifications E3 I3 China Flameproof Ex d II B+H 2 T3~T5 China Intrinsic Safety Ex ia IIC T3/T4 IECEx Certifications I7 IECEx Intrinsic Safety Certificate No.: IECExBAS08.0025X Ex ia IIC T4 (T a = -60 C to 70 C) -HART IP66 Input Parameters Loop / Power Groups U i = 30 V HART I i = 300 ma HART P i = 1.0 W HART C i = 14.8 nf HART L i = 0 HART Special conditions for safe use (x) The 3051SMV HART 4-20mA is not capable of withstanding the 500V test as defined in clause 6.3.12 of IEC 60079-11. This must be taken into account during installation. N7 IECEx Type n Certificate No.: IECExBAS08.0026X Ex nanl IIC T4 (Ta = -40 C to 70 C) Ui = 45 Vdc MAX IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500 V insulation test required by Clause 6.8.1 of IEC 60079-15. E7 IECEx Flameproof Certificate No.: IECExKEM08.0010X Ex d IIC T6 (-50 C T amb 65 C) Ex d IIC T5 (-50 C T amb 80 C) V max = 42.4V Special conditions for safe use (x) 1. Appropriate ex d blanking plugs, cable glands, and wiring needs to be suitable for a temperature of 90 C. 2. This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for maintenance shall be followed in detail to assure safety during its expected lifetime. 3. The 3051SMV does not comply with the requirements of IEC 60079-1 Clause 5.2, Table 2 for all joints. Contact Emerson Process Management for information on the dimensions of flameproof joints. Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. K1 Combination of E1, I1, N1, and ND K2 Combination of E2 and I2 K4 Combination of E4 and I4 K5 Combination of E5 and I5 K6 Combination of E6 and I6 K7 Combination of E7, I7, and N7 KA Combination of E1, E6, I1, and I6 KB Combination of E5, E6, I5, and I6 KC Combination of E5, E1, I5 and I1 KD Combination of E5, E6, E1, I5, I6, and I1 13

Product Data Sheet 14 Rosemount 3051SFC with Measurement Type D Certifications Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co., LTD Beijing, China Emerson Process Management LTDA Sorocaba, Brazil Emerson Process Management (India) Pvt. Ltd. Daman, India Ordinary Location Certification for FM As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option) Pressure Transmitters QS Certificate of Assessment - EC No. PED-H-100, Module H Conformity Assessment All other Model 3051S Pressure Transmitters Sound Engineering Practice Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold Sound Engineering Practice Primary Elements, Flowmeter See appropriate Primary Element QIG Electro Magnetic Compatibility (EMC) (2004/108/EC) EN 61326-1:1997 + A1, A2, and A3 Industrial Radio and Telecommunications Terminal Equipment Directive (R&TTE)(1999/5/EC) Emerson Process Management complies with the R&TTE Directive. HART & FOUNDATION Fieldbus Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust Ignition-proof for Class II and Class III, Division 1, Groups E, F, and G; hazardous locations; enclosure Type 4X, conduit seal not required when installed according to Rosemount drawing 03151-1003. I5/IE Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1; Class I, Zone 0 AEx ia IIC when connected in accordance with Rosemount drawing 03151-1006; Non-Incendive for Class I, Division 2, Groups A, B, C, and D Enclosure Type 4X For entity parameters see control drawing 03151-1006. Canadian Standards Association (CSA) All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003. E6 Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust Ignition-proof for Class II and Class III, Division 1, Groups E, F, and G; suitable for Class I, Division 2, Groups A, B, C, and D, when installed per Rosemount drawing 03151-1013, CSA Enclosure Type 4X; conduit seal not required. I6/IF Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings 03151-1016; For entity parameters see control drawing 03151-1016. European Certifications I1/IA ATEX Intrinsic Safety Certificate No.: BAS01ATEX1303X II 1G Ex ia IIC T4 (T a = -60 C to 70 C) -HART/Remote Display/Quick Connect/HART Diagnostics Ex ia IIC T4 (T a = -60 C to 70 C) -FOUNDATION fieldbus Ex ia IIC T4 (T a = -60 C to 40 C) -FISCO 1180 Input Parameters Loop / Power Groups U i = 30 V HART / FOUNDATION fieldbus/ Remote Display / Quick Connect / HART Diagnostics U i = 17.5 V FISCO I i = 300 ma HART / FOUNDATION fieldbus/ Remote Display / Quick Connect / HART Diagnostics I i = 380 ma FISCO P i = 1.0 W HART / Remote Display / Quick Connect / HART Diagnostics P i = 1.3 W FOUNDATION fieldbus P i = 5.32 W FISCO C i = 30 nf SuperModule Platform / Quick Connect C i = 11.4 nf HART / HART Diagnostics C i = 0 FOUNDATION fieldbus / Remote Display / FISCO L i = 0 HART / FOUNDATION fieldbus/ FISCO / Quick Connect / HART Diagnostics L i = 60 µh Remote Display Special conditions for safe use (x) 1. The apparatus, excluding the Types 3051 S-T and 3051 S-C (In-line and Coplanar SuperModule Platforms respectively), is not capable of withstanding the 500V test as defined in Clause 6.4.12 of EN 50020. This must be considered during installation. 2. The terminal pins of the Types 3051 S-T and 3051 S-C must be protected to IP20 minimum.

Product Data Sheet N1 ND E1 ATEX Type n Certificate No.: BAS01ATEX3304X II 3 G EEx nanl IIC T4 (T a = -40 C TO 70 C) Ui = 45 Vdc max IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500V insulation test required by Clause 6.8.1 of EN 60079-15. This must be taken into account when installing the apparatus. ATEX Dust Certificate No.: BAS01ATEX1374X II 1 D T105 C (-20 C T amb 85 C) V max = 42.4 volts max A = 22 ma IP66 1180 Special conditions for safe use (x) 1. The user must ensure that the maximum rated voltage and current (42.4 volts, 22 milliampere, DC) are not exceeded. All connections to other apparatus or associated apparatus shall have control over this voltage and current equivalent to a category ib circuit according to EN 50020. 2. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP66. 3. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact test. 5. The 3051S must be securely screwed in place to maintain the ingress protection of the enclosure. (The 3051S SuperModule must be properly assembled to the 3051S housing to maintain ingress protection.) ATEX Flameproof Certificate No.: KEMA00ATEX2143X Ex d IIC T6 (-50 C T amb 65 C) Ex d IIC T5 (-50 C T amb 80 C) V max = 42.4V 1180 II 1/2 G Special conditions for safe use (x) 1. Appropriate ex d blanking plugs, cable glands, and wiring needs to be suitable for a temperature of 90 C. 2. This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for maintenance shall be followed in detail to assure safety during its expected lifetime. 3. The 3051S does not comply with the requirements of EN 60079-1 Clause 5.2, Table 2 for all joints. Contact Emerson Process Management for information on the dimensions of flameproof joints. Japanese Certifications E4 TIIS Flameproof Ex d IIC T6 China (NEPSI) Certifications I3 China Intrinsic Safety Certificate No. (manufactured in Chanhassen, MN): GYJ081078 Certificate No. (manufactured in Singapore): GYJ06367 Ex ia IIC T3~T5 Input Parameters Loop / Power Groups U i = 30 V HART / FOUNDATION fieldbus/ Remote Display / Quick Connect / HART Diagnostics U i = 17.5 V FISCO I i = 300 ma HART / FOUNDATION fieldbus/ Remote Display / Quick Connect / HART Diagnostics I i = 380 ma FISCO P i = 1.0 W HART / Remote Display / Quick Connect / HART Diagnostics P i = 1.3 W FOUNDATION fieldbus P i = 5.32 W FISCO C i = 30 nf SuperModule Platform / Quick Connect C i = 11.4 nf HART / HART Diagnostics C i = 0 FOUNDATION fieldbus / Remote Display / FISCO L i = 0 HART / FOUNDATION fieldbus/ FISCO / Quick Connect / HART Diagnostics L i = 60 µh Remote Display E3 Certificate TC15682 TC15683 TC15684 TC15685 TC15686 TC15687 TC15688 TC15689 TC15690 TC17102 China Flameproof Certificate No.: GYJ06366 Ex d IIB+H 2 T3~T5 Description Coplanar with Junction Box Housing Coplanar with PlantWeb Housing Coplanar with PlantWeb Housing and LCD Display In-Line SST with Junction Box Housing In-Line Alloy C-276 with Junction Box Housing In-Line SST with PlantWeb Housing In-Line Alloy C-276 with PlantWeb Housing In-Line SST with PlantWeb Housing and LCD Display In-Line Alloy C-276 with PlantWeb Housing and LCD Display Remote Display 15

Product Data Sheet IECEx Certifications E7 IECEx Flameproof Certificate No.: IECExKEM08.0010X Ex d IIC T6 (-50 C T amb 65 C) Ex d IIC T5 (-50 C T amb 80 C) V max = 42.4V Special conditions for safe use (x) 1. Appropriate ex d blanking plugs, cable glands, and wiring needs to be suitable for a temperature of 90 C. 2. This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for maintenance shall be followed in detail to assure safety during its expected lifetime. 3. The 3051S does not comply with the requirements of IEC 60079-1 Clause 5.2, Table 2 for all joints. Contact Emerson Process Management for information on the dimensions of flameproof joints. I7/IG IECEx Intrinsic Safety Certificate No.: IECExBAS04.0017X Ex ia IIC T4 (T a = -60 C to 70 C) -HART/Remote Display/Quick Connect/HART Diagnostics Ex ia IIC T4 (T a = -60 C to 70 C) -FOUNDATION fieldbus Ex ia IIC T4 (T a = -60 C to 40 C) -FISCO IP66 Input Parameters Loop / Power Groups U i = 30 V HART / FOUNDATION fieldbus/ Remote Display / Quick Connect / HART Diagnostics U i = 17.5 V FISCO I i = 300 ma HART / FOUNDATION fieldbus/ Remote Display / Quick Connect / HART Diagnostics I i = 380 ma FISCO P i = 1.0 W HART / Remote Display / Quick Connect / HART Diagnostics P i = 1.3 W FOUNDATION fieldbus P i = 5.32 W FISCO C i = 30 nf SuperModule Platform / Quick Connect C i = 11.4 nf HART / HART Diagnostics C i = 0 FOUNDATION fieldbus / Remote Display / FISCO / Quick Connect / HART Diagnostics L i = 0 HART / FOUNDATION fieldbus / FISCO / Quick Connect / HART Diagnostics L i = 60µ H Remote Display N7 IECEx Type n Certificate No.: IECExBAS04.0018X Ex nc IIC T4 (T a = -40 C to 70 C) Ui = 45 Vdc MAX IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500 V insulation test required by Clause 8 of IEC 60079-15. Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. K1 Combination of E1, I1, N1, and ND K2 Combination of E2 and I2 K5 Combination of E5 and I5 K6 Combination of E6 and I6 K7 Combination of E7, I7, and N7 KA Combination of E1, I1, E6, and I6 KB Combination of E5, I5, I6 and E6 KC Combination of E5, E1, I5 and I1 KD Combination of E5, I5, E6, I6, E1, and I1 Special conditions for safe use (x) 1. The Models 3051S HART 4-20mA, 3051S fieldbus, 3051S Profibus and 3051S FISCO are not capable of withstanding the 500V test as defined in clause 6.4.12 of IEC 60079-11. This must be taken into account during installation. 2. The terminal pins of the Types 3051S-T and 3051S-C must be protected to IP20 minimum. 16

Product Data Sheet Rosemount 3051SFC Wireless Certifications Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co., LTD Beijing, China Emerson Process Management LTDA Sorocaba, Brazil Emerson Process Management (India) Pvt. Ltd. Daman, India Telecommunication Compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. FCC and IC Approvals This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference this device and must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20cm from all persons. Ordinary Location Certification for FM As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option) Pressure Transmitters QS Certificate of Assessment - EC No. PED-H-100, Module H Conformity Assessment All other Model 3051S Pressure Transmitters Sound Engineering Practice Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold Sound Engineering Practice Primary Elements, Flowmeter See appropriate Primary Element QIG Electro Magnetic Compatibility (EMC) (2004/108/EC) EN 61326-1:1997 A1, A2, A3 (1) EN 61326-1:2006 EN 61326-2-3:2006 Radio and Telecommunications Terminal Equipment Directive (R&TTE)(1999/5/EC) Emerson Process Management complies with the R&TTE Directive. Hazardous Locations Certifications North American Certifications Factory Mutual (FM) Approvals I5 FM Intrinsically Safe, Non-Incendive, and Dust Ignition-proof. Intrinsically Safe for Class I/II/III, Division 1, Groups A, B, C, D, E, F, and G. Zone Marking: Class I, Zone 0, AEx ia llc Temperature Codes T4 (T amb = -50 to 70 C) Non-Incendive for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II/III, Division 1, Groups E, F, and G. Ambient temperature limits: -50 to 85 C For use with Rosemount SmartPower options 00753-9220-0001 only. Enclosure Type 4X / IP66 CSA - Canadian Standards Association I6 (1) Only applies to Operating Frequency and Protocol option code 1. All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003. CSA Intrinsically Safe Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. Temp Code T3C Enclosure Type 4X / IP66 For use with Rosemount SmartPower options 00753-9220-0001 only. 17