Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Similar documents
INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Lumination TM Controls Accessory LPL Series Controller Box

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

LED Emergency Battery Backup

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

Installation Instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

IR Speed Dome. Quick Guide UD.6L0201B1357A01

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

SERVICE BY QUALIFIED PERSONNEL ONLY

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

MaxLite LED Round Pendant Highbay Series

CDL8 LED Architectural

IntelliLED TM. Daylight Harvesting Sensor (DLH): User Guide

Installation Instructions. Tersen. Ratio Canopy 1.5

SECTION INTERIOR LIGHTING

/9308 External Battery Chargers Installation Instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

LED IMPORTANT SAFETY INSTRUCTIONS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

1. Read all instructions before proceeding with the installation. Improper installation may void warranties.

Wireless High Bay Sensor (WHS100) Installation Instructions

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

WPLED 26W INSTALLATION INSTRUCTIONS

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

52 BERKSHIRE CEILING FAN

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

LED IMPORTANT SAFETY INSTRUCTIONS

ESRB and ESRN Installation & Safety Instructions

Network Camera. Quick Guide DC-T1233WHX. Powered by

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

4100U City and Relay Cards Installation Instructions

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Panel Remote Annunciators Installation Instructions

BOLLARD EMERGENCY INSTALLATION INSTRUCTIONS

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS

HDCVI PTZ Camera. 6C Series. Quick Start Guide Version Dahua Technology USA Inc.

180 Degree Ceiling Mounted Occupancy Sensors

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Room Sensor for BACnet VAV Actuator

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

3M Benchtop Air Ionizer 963E. User s Guide

Lumination TM Volumetric Retrofit Kit

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

DHL-LP-LED Low Profile LED Linear High/Low Bay

Table of Contents. 1 M /11/13 Casablanca Fan Company What to Expect with Your Installation

INSTALLATION INSTRUCTIONS

Wireless Occupancy Sensor:

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

Bdl60u Fluorescent Emergency Ballast

52 CEILING FAN. Owner s Manual Models #50336, 50337

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

Installation and Maintenance Manual IM 1038

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

HDCVI PTZ Network Camera

/ XPS Interconnection Diagrams

5000 INSTALLATION GUIDE

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

Dimmable LED Retrofit Kit

4 MP HDCVI PTZ In-ceiling Camera

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Network Display Unit Installation Instructions

Thermal Stability Systems

Operating Instructions

KM300 Carbon Monoxide Detection System Installation Manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

Universal Fan and Light Remote Control

CEILING FAN OWNER S MANUAL

Cold Door 2 LED Retrofit Kit Lighting System

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Transcription:

E Lighting Installation uide Albeo TM LED Accessory (Emergency attery ackup Module) EFOE YOU EI ead these instructions completely and carefully. ead and follow appropriate Lumination LED Installation uide for fixture installation. IMPOTAT SAFEUADS HE USI ELECTICAL EQUIPMET, ASIC SAFETY PECAUTIOS SHOD ALAYS E FOLLOED ICLUDI THE FOLLOI: EAD AD FOLLO ALL SAFETY ISTUCTIOS 1. Turn power off before inspection, installation or removal. 2. To reduce the risk of electric shock, disconnect both normal and emergency power suppliers before servicing. 3. The emergency driver must be fed from the same branch circuit as the AC driver. 4. Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field replaceable. Contact the manufacturer for information on service. 5. Follow all EC and local codes. Properly ground electrical enclosure. 6. Use only listed wire for input/output connections. Minimum size 18 A (0.75mm 2 ). 7. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 8. Do not use outdoors. 9. Do not mount near gas or electric heaters. 10. Do not use this equipment for other than intended use. 11. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 12. Use caution when servicing batteries. attery acid can cause burns to skin and eyes. If acid is spilled on skin or eyes, flush acid with fresh water and contact a physician immediately. SAVE THESE ISTUCTIOS i-cd or LiFePO4 attery The rechargeable battery in this product must be recycled or disposed of properly. This equipment is not self-testing in conformance with the Life Safety Code, ASI/FPA 101 imagination at work

ISK OF ELECTIC SHOCK Turn power off before inspection, installation or removal. Properly ground electrical enclosure. AI ISK OF FIE Follow all EC and local codes. Use only or IEC approved wire for input/output connections. Minimum size 18 A. This device complies with Part 15 of the FCC ules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CA ICES-005 (A) / M-005 (A) ote: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC ules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Optional Installation: Dimming or Control Interface Follow instructions from appropriate Albeo LED Installation Instructions to install optional control interfaces. ote: The fixture will not be controllable during emergency operation. Emergency Lighting Fixture Operation The emergency driver is capable of operating the LED load for a minimum of 90 minutes. The emergency driver battery recharge time is 32 hours. After installation, the battery should be allowed to charge. This emergency lighting fixture should be tested regularly according to national and local code requirements. To test the emergency driver, remove AC power or press and hold the indicator test switch. Take standard precautions against static discharge while operating indicator test switch. Prepare Electrical iring Electrical equirements The LED driver must be supplied with 120-277 VAC, 50/60 Hz per product label and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker. rounding Instructions The grounding and bonding of the overall system shall be done in accordance with ational Electric Code (EC) Article 600 and local codes. Installation of EM when Shipped with E Fixture Follow appropriate Albeo LED Installation Instructions to install the fixture. Take standard precautions against static discharge during fixture installation. ote: As received from the manufacturer, the luminaire may be partially energized. ote: Per 924 and for best results, mount emergency lighting unit at a maximum of 35 feet. ote: Mechanical attachment of EM to fixture required. 1 emove the conduit nut from the nipple adapter 2 on the fixture. Loosen two screws to remove the top cover of the EM unit.

Tighten nut 3 Push fixture wires through EM unit side hole. Ensure ends are capped off. Mount EM unit to nipple and fasten conduit nut. Ensure that the EM is facing downwards. 4 Locate battery plug and push into the corresponding receptacle on the side of the charger. Proceed to the Electrical Connections section to complete. etrofit and Stand-Alone Installation ote: As received from the manufacturer, the luminaire may be partially energized. ote: Per 924 and for best results, mount emergency lighting unit at a maximum of 35 feet. ote: hen using a focusing optic, the installer may need to replace the installed lens with a different provided lens to meet the correct photometric requirements. 1 Loosen two screws to remove the top cover of the EM unit. 2 Install the provided standoff nipple adapter into the appropriate mounting hole. Mount to fixture, junction box, conduit, etc. 3 Using the attached nipple adapter, mount the EM 4 to an appropriate means of mounting (fixture, junction box, conduit, etc.). Ensure that the EM is facing downwards. Locate battery plug and push into the corresponding receptacle on the side of the charger. Proceed to the Electrical Connections section to complete.

Electrical Connections 1 2 3 4 Follow Electrical Connections instructions from an appropriate Albeo LED Installation uide. Use listed fittings for wire protection. efer to the applicable diagram below. Using listed 18-14 A twist-on wire connectors, connect the black (unswitched line), black (switched line), and white (neutral) input wires. Connect the ground wire to the green grounding wire as provided. Important: Make sure the necessary branch circuit wiring is available. An unswitched source of power is required. The emergency driver must be fed from the same branch circuit as the AC driver. Check that all internal plugs are connected to the battery charge unit. If a connector is loose, plug the connector into the appropriate receptacle on the battery charge unit. Seal any remaining hole in the EM cover with the provided plug. eattach EM cover. Do not overtighten screws. with EM with Two Power Drops 2 1 SL / EM = Unswitched Line SL = Switched Line = eutral = round = lack = hite = ire Connector Switched with EM with One Power Drop SL EM = Unswitched Line SL = Switched Line = eutral = round = lack = hite = ed = ire Connector

Unswitched with EM with One Power Drop EM = Unswitched Line SL = Switched Line = eutral = round = lack = hite = ed = ire Connector with EM & Motion Sensor with Two Power Drops OTE: hen luminaire is purchased with a sensor, additional wiring (not included) may be required to connect EM to supply power. 2 1 SL / EM Motion Sensor = Unswitched Line SL = Switched Line = eutral = round = lack = hite = ire Connector Switched with EM & Motion Sensor with One Power Drop SL Motion Sensor EM = Unswitched Line SL = Switched Line = eutral = round = lack = hite = ed = ire Connector

Unswitched with EM & Motion Sensor with One Power Drop EM Motion Sensor = Unswitched Line SL = Switched Line = eutral = round = lack = hite = ed = ire Connector Stand-Alone EM = Unswitched Line = eutral = round = lack = hite = ire Connector www.gelighting.com E and the E Monogram are trademarks of the eneral Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. E Lighting is a business of the eneral Electric Company. 2017 E. AL030 (ev 09/07/17)