Network Display Unit Installation Instructions

Similar documents
Panel Remote Annunciators Installation Instructions

/ XPS Interconnection Diagrams

/9308 External Battery Chargers Installation Instructions

4100U City and Relay Cards Installation Instructions

Class A and Expansion NAC Modules Installation Instructions

Fire Control Panels. Network Annunciator Panels Network Display Unit (NDU) UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features

Panel Message Memory Expansion Cards Installation Instructions

/5121/5122 TrueAlert Power Supply Installation Instructions

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

TrueAlarm Fire Alarm Systems

Addressable IDNet Isolator Installation Instructions

4009 Fiber Optic Link Option Installation Instructions

4100ES Fire Alarm System

ALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions.

4010 Fire Alarm Parts List

Fire Control Panels. Basic Panel Modules and Accessories

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

4100ES Fire Control Panels

AU MX Digital Loop Card Installation Instructions

4010 Fire Alarm Front Panel Installing, Operating, and Programming Instructions

4100ES Fire Indicator Panel Installation & Maintenance

Doc. No Part No Rev. U * T*

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

NETWORK FIRE ALARM CONTROL PANEL. Features

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

TrueAlarm Fire Alarm Controls

Fire Detection and Alarm

Certificate of Conformity Certificate num. Registration date Version Valid until

4100ES-S1 Fire Indicator Panel Installation & Maintenance

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Fire Control Units. Addressable Fire Detection and Control Basic Control Unit Modules and Accessories. UL, ULC Listed; FM Approved* Features

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

CATALOG NUMBER. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Fire Alarm Network Reference

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC Listed, FM Approved* Features

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

CHERRY POINT BOQ B-487 CHERRY POINT, NC. Fire Alarm System Equipment Data Submittal February 4, Dividend Loop Myrtle Beach, SC 29577

4010 Fire Alarm PC Programmer Installation and Programming Instructions

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

TrueAlarm Addressable Fire Alarm Control Panels

4007ES Fire Control Panels

Network Hardware and wiring (quiz)...

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

TrueAlarm Analog Sensing

IDNet and MAPNET II Addressable Devices

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

Software Release M2.7 Summary for the Notifier AM2020/AFP1010 Fire / Security Control Panels, Including NOTI FIRE NET and Peripherals

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

4100U-S1 Fire Indicator Panel Installation & Maintenance

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

4010 Fire Alarm Applications Manual

TrueAlarm Fire Alarm Systems

INTELLIGENT FIRE ALARM CONTROL PANEL

TrueAlert Addressable Notification Appliances

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

TrueAlarm Fire Alarm Controls

TrueAlarm Fire Alarm Systems

4007ES Fire Control Panels

4100U Fire Indicator Panel Australian Wiring Diagrams

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

Reverse Chronological Order by Date of Last Revision... page 2. Numerical Order... page 4. Discontinued/Inactive Data Sheets...

4005 Fire Alarm Installation and Operating Instructions

LifeAlarm Fire Alarm Controls

Rev. B. TrueAlert Addressable Controller Application Manual

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

4007ES Fire Control Panels

CARD ACCESS CONTROL SYSTEM

Functional Performance Test

FCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual

Alarm annunciation, control and communication systems

June 10, 2002 DF C S2424

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Addressable Fire Alarm Control Panel

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

LifeAlarm Fire Alarm Control Panels

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system

FireNET Plus Wiring Instructions

4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

The System 5000 Operating Manual

The ACM-8R Annunciator Control Module

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

TECOM SYSTEMS NETWORK MASTER

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Z-20 Fire Control Panels

Rev. A. Technical Manuals Online! -

E3 Series Broadband System

Transcription:

Network Display Unit Installation Instructions Introduction This publication describes the installation procedures for the optional Network Display Units (NDUs). This product is compatible with both the 4100U and the 4100ES Fire Alarm Control Panels (FACP). In This Publication This publication discusses the following topics: Topic See Page # Cautions and Warnings 2 Introduction to the NDU 3 Compatible NDU Modules 5 NDU Installation 6 2005, 2011 SimplexGrinnell LP. All rights reserved. Specifications and other information shown were current as of publication and are subject to change without notice. Simplex and the Simplex logo are trademarks of Tyco International Ltd. and its affiliates and are used under license. 579-269 Rev. F

Cautions and Warnings Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation manual. These instructions must be followed to avoid damage to this product and associated equipment. Product operation and reliability depend upon proper installation. DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED- Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier. ELECTRICAL HAZARD - Disconnect electrical field power when making any internal adjustments or repairs. All repairs should be performed by a representative or authorized agent of your local Simplex product supplier. STATIC HAZARD - Static electricity can damage components. Handle as follows: Ground yourself before opening or installing components. Prior to installation, keep components wrapped in anti-static material at all times. EYE SAFETY HAZARD - Under certain fiber optic application conditions, the optical output of this device may exceed eye safety limits. Do not use magnification (such as a microscope or other focusing equipment) when viewing the output of this device. FCC RULES AND REGULATIONS PART 15 - This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. SYSTEM REACCEPTANCE TEST AFTER SOFTWARE CHANGES To ensure proper system operation, this product must be tested in accordance with NFPA 72 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions, known to be affected by a change, must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. NFPA 72 is a registered trademark of the National Fire Protection Association. 2

Introduction to the NDU Overview The 4100-series NDU is a configurable Fire Alarm System Panel that functions as a receiving unit for proprietary systems. The NDU is a network annunciator and manual system/point controller for a Simplex Fire Alarm Network. It provides either alphanumeric or multi-line LCD annunciation for network points and/or point lists, and can be programmed to function as the network master controller for Alarm Silence, Trouble Acknowledge, and System Reset. Multi-line LCD annunciation is part of the Flexible User Interface option. When connected to other 4100-series products as part of a 4100 network, fire alarm control panels become components of a distributed intelligent system. Each panel that directly connects to the network is called a network node, and is capable of performing individual supervision and control on its locally connected devices, and has the network ability to inform the NDU (as well as other network control panels) of point status and panel condition. This allows system information to reach the proper location for appropriate system response. Multiple NDUs (separately packaged) can be connected to a 4100 network to duplicate common information at separate locations, or direct selected information by type such as troubles and alarms. The NDU s master controller assembly supports the operator s panel, provides local and remote module communications and supervision, and controls the system memory and custom programming interface. Table 1 lists the different types of NDUs. Continued on next page. 3

Introduction to the NDU, continued Overview (continued) PID 4100-9141 NDU (U.S.) 4100-9151 NDU w/ Flexible User Interface (U.S) 4100-9245 NDU w/ Flexible User Interface (International) Table 1. NDU PIDs Components 120 VAC, 60 Hz; includes display, CPU card, network interface card, system power supply with 50 Ah battery charger 4100-9142 NDU w/ Voice (U.S.) 4100-9152 NDU w/ Voice and Flexible User Interface (U.S) 4100-9246 NDU w/ Voice and Flexible User Interface (International) 4100-9143 NDU (Canadian English) 4100-9153 NDU w/ Flexible User Interface (Canadian English) 4100-9144 NDU (Canadian French) 4100-9154 NDU w/ Flexible User Interface (Canadian French) 4100-9145 NDU w/ Voice (Canadian English) 4100-9155 NDU w/ Voice & Flexible User Interface (Canadian English) 4100-9146 NDU w/ Voice (Canadian French) 4100-9156 NDU w/ Voice & Flexible User Interface (Canadian French) 4100-9241 NDU (International) 4100-9243 NDU w/ Flexible User Interface 120 VAC, 60 Hz; includes display, 2 CPU cards, 2 network interface cards, 2 system power supplies with 50 Ah battery charger (occupies 2 bays) 120 VAC, 60 Hz; includes display, CPU card, network interface card, system power supply with 50 Ah battery charger and battery cutout circuit 120 VAC, 60 Hz; includes display, 2 CPU cards, 2 network interface cards, 2 system power supplies with 50 Ah battery charger and battery cutout circuit (occupies 2 bays) 220/240 VAC, 50/60 Hz; includes display, CPU card, network interface card, system power supply with 50 Ah battery charger 4100-9242 NDU w/ Voice (International) 220/240 VAC, 50/60 Hz; includes display, 4100-9244 NDU w/ Voice & Flexible User 2 CPU cards, 2 network interface cards, 2 Interface system power supplies with 50 Ah battery charger (occupies 2 bays) Specifications Temperature: 32 F to 120 F (0 C to 49 C) Humidity: 93% Non-condensing @ 90 F (32 C) Input Power Requirements: 4 A @ 120 VAC, 60 Hz 2 A @ 240 VAC, 50/60 Hz for each power supply 4

Compatible NDU Modules List of Modules Not all modules are compatible with the NDU. The following lists compatible modules that may be used with the NDU. 4100-6014 Network Interface Card (NIC). Multiple communications media are available on the 4120-6014 Modular Interface Card with selectable media cards. Media cards include fiber optics, wired, and modem communications and may be mixed on one interface card. 4100-6030 Service Modem. Provides remote data access for a computer equipped with a modem and terminal emulation software. 4100-6038 Dual RS-232 Module. Used for connections to printers and computer CRTs. 4100-0634 Tamper Switch. Monitor the switch with an IDNet Individual Adapter Module (IAM) or monitor point in a non-ndu node. 4100-1293 Panel-Mounted Printer. Provides hard copy reports of the master control panel's output. 4100-6052 DACT. Notifies the central station when specified events occur; reports changes to a specific point s status to the central station. For additional information on any of these modules, refer to the manuals in their individual ship groups. Note: The Voice Command Center (VCC) option adds Voice Evac capability to the system, and the VCC is operated from controls at the NDU. The VCC is actually a separate 4100U/4100ES node than the NDU. 5

NDU Installation Installation for NDU without Audio The 4100-9141/9143/9144/9241/9151/9153/9154/9243/9245 NDU (non-audio) is made up of several modules, and each module has its own set of installation instructions. The figure below shows the general setup for the non-audio NDU. Refer to the appropriate manuals to install specific modules. Manuals are found in each module s ship group. FigureTag FD9-269-01 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 RUI, DACT, or 24-POINT I/O MODULE RUI, RS-232, or 24-POINT I/O MODULE MASTER CONTROLLER with SERVICE MODEM NIC or RS-232 MODULE with MEDIA CARD Network Bd Network Media Bds Service Modem 4100-6030 Master Controller Board IDNet NACs 1, 2 & 3 System Power Supply (SPS) SPS Mezzanine Btry Cards + - Aux Aux City Circuit Pwr Relays 4100-6031 4100-6032 Alarm Relay 4100-6033 Chassis CPU Bay 1: Includes operator interfacee CITY CARD OR RELAY CARD Module types NOT allowed: IDNet MAPNET Zone Relay (except for SPS card) NAC Expansion Bays: Use power distribution interface; any applicable combination of non-audio 4 x 5 modules and motherboards is permitted, with the exception of IDNet, MAPNET, zone, relay, and NAC modules. Figure 1. The Non-Audio NDU Continued on next page 6

NDU Installation, Continued Installation for NDU with Audio The 4100-9142/9145/9146/9242/9152/9155/9156/9244/9246 use audio modules Note: The battery charger may need to be disabled on either one of the SPS shown. Earth detect should also be disabled on one SPS. RUI, DACT, or 24-POINT I/O MODULE RUI, RS-232, or 24-POINT I/O MODULE MASTER CONTROLLER with SERVICE MODEM NIC or RS-232 MODULE with MEDIA CARD There is no power/comms connection between these two bays. RUI, DACT, or 24-POINT I/O MODULE* RUI, RS-232, or 24-POINT I/O MODULE* MASTER CONTROLLER with SERVICE MODEM NIC or RS-232 MODULE with MEDIA CARD ANALOG or DIGITAL AUDIO CONTROLLER Module types NOT allowed: IDNet MAPNET Zone Relay (except for SPS card) NAC AUDIO INPUT CARD(S), PHONE CARD, or OTHER MODULES** Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Network Bd Network Bd Network Media Bds Network Media Bds Service Modem 4100-6030 Service Modem 4100-6030 Master Controller Board Master Controller Board Aux Pwr Aux Pwr IDNet IDNet System Power Supply Aux Relays Chassis System Power Supply Aux Relays (SPS) Chassis NACs 1, 2 & 3 SPS Mezzanine Cards City Circuit 4100-6031 4100-6032 Alarm Relay 4100-6033 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 (SPS) FLEX 50 AMP ** BLANK *LED/switch modules and LED/switch controllers may be installed to front of assembly. **Other modules in these slots may be phones, phone cards, microphones, or LED/switch modules. Figure 2. The NDU with Audio FigureTag FD9-269-02 NACs 1, 2 & 3 SPS Mezzanine Cards City Circuit 4100-6031 4100-6032 Alarm Relay 4100-6033 I/O Wiring XPS** Btry + - Btry + - CPU Bay 1: Includes operator interface CITY CARD OR RELAY CARD CPU Bay 2: No operator interface, unless LED/switch interface is installed. CITY CARD Sample Expansion Bay with Audio: Uses power distribution interface; any applicable combination of audio and LED/switch modules is permitted. 7

579-269 Rev. F