INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

DOUBLE DISHDRAWER TM DISHWASHER

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DOUBLE DISHDRAWER TM DISHWASHER

DOUBLE DISHDRAWER TM DISHWASHER

INSTALLATION INSTRUCTIONS

SINGLE DISHDRAWER TM DISHWASHER

DOUBLE DISHDRAWER TM DISHWASHER

DOUBLE DISHDRAWER TM DISHWASHER

Installation instructions DishDrawer SAFETY AND WARNINGS

Installation instructions DishDrawer SAFETY AND WARNINGS

SAFETY AND WARNINGS. Important! SAVE THESEINSTRUCTIONS

INSTALLATION GUIDE NZ AU

DishDrawer TM dishwasher. DD24D 7 & DD24DT 7 models US CA. Fisher Paykel

INSTALLATION GUIDE NZ AU C

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation instructions IZONA CoolDrawer SAFETY AND WARNINGS. Important!

Installation Instructions

Installation Instructions

Dishwasher Installation Instructions DW 24XT/DW 24XV

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Top Control Dishwasher

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

Installation Instructions Built-In Dishwasher

Installation Instructions Built-In Dishwasher

Installation Instructions Built-In Dishwasher

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Dishwasher Installation Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

SAVE THESE INSTRUCTIONS

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Installation Instructions

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Viking Installation Guide

DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions Built-In Dishwasher

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Installation Guide. 1 & 3 Series Built-In Dishwashers. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation Instructions

INSTALLATION GUIDE NZ AU GB IE

Installation Instructions 30 French Door Built-in Wall Ovens

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Dishwasher. Installation manual DW60M9990AP

2 PREPARE THE OPENING

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE NZ AU GB IE A

INSTALLATION GUIDE NZ AU GB IE C

INSTALLATION INSTRUCTIONS

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION GUIDE NZ AU GB IE SG F

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE NZ AU GB IE C

INSTALLATION INSTRUCTIONS

Installation instructions. Built-in oven NZ AU. BI453 and BI603 models

INSTALLATION GUIDE NZ AU F

Installation. Leveling

INSTALLATION INSTRUCTIONS

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

Installation Instructions

Installation Instructions

INSTALLATION. Glass Panel Doors (select models) CAUTION

FI DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHER PLASTIC TUB INSTRUCCIONES DE INSTALACIÓN LAVAVAJILLAS EMPOTRADA CON TINA PLÁSTICA

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHER STAINLESS STEEL TUB LAVAVAJILLAS EMPOTRADA CON TINA DE ACERO INOXIDABLE

SAFETY AND WARNINGS WARNING!

INSTALLATION GUIDE NZ AU E

W C. Table of Contents... 2 Table des matières... 25

SCHWAN INSTALLATION GUIDE

Installation Instructions

Installation Instructions Renaissance Built-in Dishwasher

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

INSTALLATION INSTRUCTIONS


Installation Electric Dryers Instructions 01

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

Installation Instructions

KD-27A SERIES DISHWASHERS

Installation Instructions

Installation instructions Built-in. Dishwasher READCAREFUL KEEPTHESE INSTRUCTIONS. Model(s): DDW2405BL. IMPORTANT: The dishwasher MUST be installed to

Installation Instructions

Removing shipping locks

INSTALLATION INSTRUCTIONS

Installation Instructions

Dishwasher. Installation Manual USA DDN25400X DIN Document Number : _AA_USA/ (17:07)

Installation Instructions

SS1095 Ice Maker.

Instant Hot Water Dispenser Owner s Manual

INSTALLATION INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

Installation Instructions

Installation Instructions

Transcription:

INSTALLATION INSTRUCTIONS TM DishDrawer dishwasher DD4D 7 & DD4DT 7 models US CA 59004D 04.3

FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL STANDARD HEIGHT DOUBLE MODELS TALL HEIGHT DOUBLE MODELS Classic Designer Integrated Classic Designer Integrated DD4DCX7 DD4DCW7 DD4DCB7 DD4DDFX7 DD4DI7 DD4DCTX7 DD4DCHTX7 DD4DCTW7 DD4DCTB7 DD4DDFTX7 DD4DTI7 DD4DHTI7 PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) PRODUCT & CABINETRY DIMENSIONS (TALL HEIGHT) PRODUCT & CABINETRY DIMENSIONS (TALL HEIGHT) PRODUCT & CABINETRY DIMENSIONS (TALL HEIGHT) CAVITY PREPARATION CAVITY PREPARATION CUSTOM PANEL CALCULATIONS CAVITY PREPARATION CAVITY PREPARATION CUSTOM PANEL CALCULATIONS MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE CAVITY PREPARATION SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED METHOD (a) ALTERNATIVE METHOD (b) CHOOSE DRAINAGE OPTION SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED METHOD (a) ALTERNATIVE METHOD (b) CHOOSE DRAINAGE OPTION MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD (a) METHOD (b) SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED METHOD (a) ALTERNATIVE METHOD (b) CHOOSE DRAINAGE OPTION SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED METHOD (a) ALTERNATIVE METHOD (b) CHOOSE DRAINAGE OPTION MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD (a) METHOD (b) CONNECT TO WATER & ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING CONNECT TO WATER & ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING INSTALL THE FRONT PANELS CHOOSE DRAINAGE OPTION CONNECT TO WATER & ELECTRICITY CONNECT TO WATER & ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING CONNECT TO WATER & ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING INSTALL THE FRONT PANELS CHOOSE DRAINAGE OPTION CONNECT TO WATER & ELECTRICITY FINAL CHECKLIST FINAL CHECKLIST TROUBLESHOOTING TROUBLESHOOTING

a SAFETY AND WARNINGS - ALL MODELS Electrical hazard WARNING! Before installing the dishwasher, remove the house fuse or open the circuit breaker. If permanently connecting the dishwasher, be sure the power is isolated and the dishwasher unplugged. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly grounded. If the dishwasher is installed as a permanently connected appliance: GROUNDING INSTRUCTIONS - This appliance must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance. Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box. Failure to follow this advice may result in electrical shock or death. IMPORTANT SAFETY INSTRUCTIONS! Installation of this dishwasher requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building, electricity, and plumbing regulations. At the completion of the dishwasher installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the dishwasher. This dishwasher is manufactured for indoor use only. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations. The dishwasher MUST be installed to allow for future removal from the enclosure if service is required. The switched power outlet must be outside the dishwasher cavity, so that it is accessible after installation. Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord and hoses. If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage. Make sure only new hoses are used for connection (supplied with the dishwasher). Old hoses should not be reused. Failure to install the dishwasher correctly could invalidate any warranty or liability claims. If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, boat or mobile facility containing the product to the service shop at your expense or pay the service technician s travel to the location of the product. 3 Cut hazard WARNING! SAVE THESE INSTRUCTIONS Take care - panel edges are sharp. Failure to use caution could result in injury or cuts. b ADDITIONAL SAFETY AND WARNINGS - INTEGRATED MODELS ONLY WARNING! Electrical Shock Hazard WARNING: To reduce the risk of electrical shock, fire, or injury to persons, the installer must ensure that the dishwasher is completely enclosed at the time of installation. Before fitting the front panels, make sure that the dishwasher is disconnected from the power supply.after installing the front panels, the installer must ensure that the following components are electrically grounded: the panel bracket and any custom metal component (e.g. handle) that extends past the rubber seal. Failure to follow these warnings may result in electrical shock, injury or fire. IMPORTANT SAFETY INSTRUCTIONS! Read these instructions completely and carefully. Ensure the product is not plugged in. Installation of custom panels requires basic mechanical and electrical skills. Installation must comply with your local building and electricity regulations. Failure to install the custom panels correctly could invalidate any warranty or liability claims. SAVE THESE INSTRUCTIONS

3a PARTS SUPPLIED - ALL MODELS 4 Drain hose support () Drain hose joiner () Wire clip () (for securing Drain hose joiner) Clamp () (for securing Drain hose joiner) Side mounting bracket kit (A and B) () OPTIONAL Top mounting brackets () OPTIONAL Phillips 5 8 (6 mm) screws (9) Rubber washer for inlet hose () (comes already fitted) Moisture protection tape () (to prevent moisture damage) Hexagonal socket for feet adjustment () (long & short) Prefinished toekick () Edge Protector () (If the services hole is through a metal partition the hole must be protected with the Edge protector supplied to prevent damage to the power cord or hoses.) If the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 55798 which will extend the drain hoses by 0 (3.6m). The kit is available from the nearest Fisher & Paykel Authorized Service Center, or Toll free.888.936.787 or www.fisherpaykel.com 3b ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS Panel bracket () (attached to product) Panel mounting screws () Toekick mounting bracket () (A custom toekick panel of any material with thickness 3 8 -¾ (9-9 mm) can be screwed to the plastic toekick mounting bracket) Toekick mounting screws (5)

4 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 5 4a REMOVE THE LOWER DRAWER 43 4b REMOVE THE ACCESS COVER & POWER CORD 4 5 4c 00 mm 4 (00mm) TERMINATE THE WIRING AS SHOWN To prevent kinked hoses, we recommend rotating the drawer anti-clockwise and resting it on its side after removal. 5 Press the release tabs in on either side and push back to release drawer from runners. Remove knock-out for cable clamp and fit a suitable cable clamp for the conduit. Access cover 4d 6 WARNING! Electrical Shock Hazard Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire. REFIT THE DRAWER ONTO THE RUNNERS & CLOSE Pull forward the release tabs on both sides 4 (00 mm) Ensure the drawer is now rotated clockwise back. 6 7 8 5 7 8 0 9 9 3 Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward. Use copper conductors only. Ensure the release tabs on both sides are reset fully. 4

5 PRODUCT DIMENSIONS 6 O K I Plan D C A N L O Side G F B E M H J Product dimensions inches (mm) STANDARD HEIGHT MODELS TALL HEIGHT MODELS Integrated Designer Classic Integrated Designer Classic A overall height of product 3 5 6-34 5 8 (80-880) 3 5 6-34 5 8 (80-880) 3 5 6-34 5 8 (80-880) 34-36 3 8 (864-94) 34-36 3 8 (864-94) 34-36 3 8 (864-94) B overall width of product 3 9 6 (599) 3 9 6 (599) 3 9 6 (599) 3 9 6 (599) 3 9 6 (599) 3 9 6 (599) C overall depth of product (excl. handle) 5 6 (58) ½ (57) ½ (57) 3 5 6 (58) ½ (57) ½ (57) 3 D depth of chassis (to back of front panel) ¾ (553) ¾ (553) ¾ (553) ¾ (553) ¾ (553) ¾ (553) E maximum extension of drawer (excl. handle) 7 8 (556) 7 6 (545) 7 6 (545) 3 7 8 (556) 7 6 (545) 7 6 (545) 3 F depth of front panel (excl. handle) 8 (9) 6 (8) 5 8-3 6 (6-0) 8 (9) 6 (8) 5 8-3 6 (6-0) G height of chassis 3 5 6 (8) 3 5 6 (8) 3 5 6 (8) 33 6 (855) 33 6 (855) 33 6 (855) H height of levelling feet 3 8-6 (9-69) 3 8-6 (9-69) 3 8-6 (9-69) 3 8-6 (9-69) 3 8-6 (9-69) 3 8-6 (9-69) I depth of handle n/a 5 8 (4) n/a n/a 5 8 (4) n/a J depth of toekick recess (to back of front panel) 4 3 6-3 5 8 (30-9) 3 6-3 5 8 (30-9) 3 6-3 5 6 (30-84) 5 3 6-3 5 8 (30-9) 3 6-3 5 8 (30-9) 3 6-3 5 6 (30-84) 5 K height of upper front panel 5 ½ (394) 5 6 (398) min. 5 6 (398) 7 ¼ (438) 7 3 8 (44) min. 7 3 8 (44) L ventilation gap between front panels 3 6 (5) 5 6 (8) min. 5 6 (8) 3 6 (5) 5 6 (8) min. 5 6 (8) M height of toekick panel (adjustable) ¾ - 4 ¾ (70-0) ¾ - 4 ¾ (70-0) ¾ - 4 ¾ (70-0) ¾ - 4 ¾ (70-0) ¾ - 4 ¾ (70-0) ¾ - 4 ¾ (70-0) N height of drawer fronts 9 3 6 (757) 30 (76) min. 8 ¼ (77) 9 6 (754) 9 5 6 (760) min. 9 5 6 (760) O height from top of handle to top of front panel n/a ½ (64) n/a n/a ½ (64) n/a includes 6 (mm) high bracket slots depending on adjustment of leveling feet 3 assuming front panel thickness of 6 (8mm) 4 adjustable to match toekick recess on adjoining cabinetry 5 assuming that toekick mounting bracket is used with a 6 (8mm) thick custom panel; if recess is between 5 6-3 5 6 (50 and 84 mm) deep, the panel will need to be cut out - see step Custom panel calculations

6 CABINETRY DIMENSIONS 7 Q R Plan S Side P T Minimum clearances from adjacent cabinetry min. ½ (3 mm) clearance from a corner cupboard min. 6 ( mm) clearance to adjacent cupboard door Cabinetry dimensions inches (mm) STANDARD HEIGHT MODELS TALL HEIGHT MODELS Integrated Designer Classic Integrated Designer Classic P inside height of cavity* min. 3 5 6 (80) min. 3 5 6 (80) min. 3 5 6 (80) min. 34 (864) min. 34 (864) min. 34 (864) Q inside width of cavity 3 5 8 (600) 3 5 8 (600) 3 5 8 (600) 3 5 8 (600) 3 5 8 (600) 3 5 8 (600) R inside depth of cavity min. 6 (560) min. 6 (560) min. 6 (560) min. 6 (560) min. 6 (560) min. 6 (560) S recommended height of adjacent cabinet space 30 (76) 30 (76) min. 8 3 8 (70) 30 (76) 30 (76) min. 30 (76) T height of toekick space* 3 8-4 ¾ (60-0) 3 8-4 ¾ (60-0) 3 5 6-6 5 6 (00-60) 3 5 6-6 5 6 (00-60) 3 5 6-6 5 6 (00-60) 3 5 6-6 5 6 (00-60) *depending on adjustment of leveling feet

7a STANDARD HEIGHT INTEGRATED MODELS ONLY - CUSTOM PANEL CALCULATIONS 8 The following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry. The final panel/cabinetry alignment is achieved by adjusting the feet: WIDTH OF ALL PANELS Measure A (the width between adjacent door/drawer fronts) and write it in the first box below, then complete the equation. A clearance to adjacent cabinet front (min. 6 ( mm)) - x = HEIGHT OF THE UPPER PANEL WIDTH OF PANEL (min. 3 7 6 (596 mm)) FRONT PANEL SPECIFICATIONS 5 8-3 6 (6-0 mm) panel thickness Adequately sealed to withstand moisture ( O F/ 50 O C @ 80% RH) Maximum weight of each panel: 0 lb (9 kg) TOEKICK PANEL SPECIFICATIONS min. 3 8 (9 mm) panel thickness if using supplied screws Adequately sealed to withstand moisture ( O F/ 50 O C @ 80% RH) You may choose to affix your custom toekick panel either by screwing it to the supplied mounting bracket or gluing it on the supplied prefinished toekick panel. A min. 6 (mm) min. 6 (mm) min. 6 (mm) minimum height 5 6 (398 mm) B upper panel extension (0 /mm recommended) + = HEIGHT OF UPPER PANEL WIDTH OF ALL PANELS HEIGHT OF UPPER PANEL min. 6 (mm) Note: The upper panel extension B allows for the top of the upper panel to extend above the chassis where required. HEIGHT OF THE LOWER PANEL D C min. 5 6 (8mm) ventilation gap Measure C (door/drawer height (or equivalent)) and write it in the first box below, then complete the equation. C (min 8 ¼ (77 mm) + B)) - height of upper panel - ventilation gap (min. 5 6 (8 mm)) HEIGHT OF LOWER PANEL (min. ¼ (3 mm) = HEIGHT OF LOWER PANEL HEIGHT OF TOEKICK PANEL HEIGHT OF THE TOEKICK PANEL Measure D (height from the top of adjacent cabinet door fronts to the floor) and write it in the first box below, then complete the equation. D B upper panel extension (0 / mm recommended) - height from top of product to toekick panel mounting point - 8 5 6 (735 mm) - clearance to floor (min. ½ ( mm)) HEIGHT OF TOEKICK PANEL (min. ¾ (70 mm)) = min. ½ (mm) clearance to floor If the toekick recess (dimension J under Product dimensions ) is between and 3 5 6 (50 and 84 mm) deep, the toekick panel will need to be modified for fitting around the underside of the product. See illustration for details on the shape of the cutout required. 3 6 (55 mm) 7 (43 mm) R ½ (.7 mm) J 3 6- (30-50 mm) J -3 5 6 (50-84 mm) Side Side

7b TALL HEIGHT INTEGRATED MODELS ONLY - CUSTOM PANEL CALCULATIONS 9 The following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry. The final panel/cabinetry alignment is achieved by adjusting the feet: WIDTH OF ALL PANELS Measure A (the width between adjacent door/drawer fronts) and write it in the first box below, then complete the equation. A clearance to adjacent cabinet front (min. 6 ( mm)) - x = HEIGHT OF THE UPPER PANEL WIDTH OF PANEL (min. 3 7 6 (596 mm)) FRONT PANEL SPECIFICATIONS 5 8-3 6 (6-0 mm) panel thickness Adequately sealed to withstand moisture ( O F/ 50 O C @ 80% RH) Maximum weight of each panel: 0 lb (9 kg) TOEKICK PANEL SPECIFICATIONS min. 3 8 (9 mm) panel thickness if using supplied screws Adequately sealed to withstand moisture ( O F/ 50 O C @ 80% RH) You may choose to affix your custom toekick panel either by screwing it to the supplied mounting bracket or gluing it on the supplied prefinished toekick panel. A min. 6 (mm) min. 6 (mm) min. 6 (mm) minimum height 7 3 8 (44 mm) B upper panel extension (0 /mm recommended) + = HEIGHT OF UPPER PANEL WIDTH OF ALL PANELS HEIGHT OF UPPER PANEL min. 6 (mm) Note: The upper panel extension B allows for the top of the upper panel to extend above the chassis where required. HEIGHT OF THE LOWER PANEL D C min. 5 6 (8mm) ventilation gap Measure C (door/drawer height (or equivalent)) and write it in the first box below, then complete the equation. C (min 30 (76 mm) + B)) - height of upper panel - ventilation gap (min. 5 6 (8 mm)) HEIGHT OF LOWER PANEL (min. ¼ (3 mm) = HEIGHT OF LOWER PANEL HEIGHT OF TOEKICK PANEL HEIGHT OF THE TOEKICK PANEL Measure D (height from the top of adjacent cabinet door fronts to the floor) and write it in the first box below, then complete the equation. D B upper panel extension (0 / mm recommended) - height from top of product to toekick panel mounting point - 30 6 (779 mm) - clearance to floor (min. ½ ( mm)) HEIGHT OF TOEKICK PANEL (min. ¾ (70 mm)) = min. ½ (mm) clearance to floor If the toekick recess (dimension J under Product dimensions ) is between and 3 5 6 (50 and 84 mm) deep, the toekick panel will need to be modified for fitting around the underside of the product. See illustration for details on the shape of the cutout required. 3 6 (55 mm) 7 (43 mm) R ½ (.7 mm) J 3 6- (30-50 mm) J -3 5 6 (50-84 mm) Side Side

8 CAVITY PREPARATION 0 COUNTERTOP Important! The power outlet must be located in a cabinet adjacent to the dishwasher cavity. 3 8 (0mm) Moisture protection tape must be applied. 0-0 VAC max. 5 A Water Connection Recommended HOT (Maximum 40 F/60 C). Supplied hose to suit 3 8 (9 mm) male compression fitting. These marks indicate formed bracket screw locations, if securing by drawer removal. If there is no side partition, you can construct timber bracing as something to secure into. max. 7 6 (450 mm) Water Pressure Water softener models Max. MPa (45 psi) Min. 0. MPa (4.5 psi) Models without water softener Max. MPa (45 psi) Min. 0.03 MPa (4.3 psi) Services hole Can be located either side of dishwasher, preferably at the bottom of the cavity, as shown. If adequate clearance, services hole can be made higher to clear toekick space. If hole is higher, ensure drain hose(s) are routed straight into the waste connection. ø max. ½ (38 mm) min. 7 7 8 (00 mm) Kosher requirements Drains will need to be separated to satisfy kosher requirements. We suggest you confirm acceptability with your local rabbi in respect to kosher installations. - If the hole is through wood, make sure its edges are smooth and rounded. - If the hole is through metal, ensure you fit the supplied Edge Protector to prevent damage to the power cord.

9 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE Left hand side Drain hoses - 78 ½ (000 mm) Inlet hose - 64 ¾ (650 mm) Power cord (excl. plug) - 9 ½ (750 mm) Right hand side Drain hoses - 70 ½ (800 mm) Inlet hose - 49 (50 mm) Power cord (excl. plug) - 7 ½ (700 mm)

NOW CHOOSE WHICH INSTALLATION METHOD (a) or (b) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (a) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 0a ATTACH SIDE MOUNTING BRACKETS a PULL THROUGH HOSES & PUSH INTO THE CAVITY B Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they re securely fitted before sliding product into cavity. A (x) optionally attach the two top mounting brackets Ensure the product is level B A A B A B The mounting slots are in pairs, one on each side diagonally across the product. A bracket must match A slot and B bracket must match B slot. You can raise or lower the product by twisting the feet. Then take care when pushing the product into the cavity that you do not bend the feet. As you push product in, pull through hoses and cord, ensuring they don t get kinked or twisted.

a SECURE TO THE CABINETRY ON THE SIDES 3a OPTIONALLY SECURE TO THE CABINETRY ABOVE 3 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the rubber trimseal. Open the drawer halfway. Using a flat-bladed screwdriver, prize the gray rubber plug out of the trim moulding. Replace the gray rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 (x) The top mounting brackets will only bend upwards a maximum of 3 8 (0 mm). Repeat for all four brackets. 4a FIT THE SUPPLIED TOEKICK PANEL (OPTIONAL FOR INTEGRATED MODELS) Where the toekick meets the bottom of the tub is the cut-off point 3 5 7 Mounting rail 9 9 Lay the toekick face down on a chopping board or similiar Turn the toekick over and score along the same line Smooth the edge with a file. Be careful of sharp edges. Mark this point on the toekick with a pencil 4 6 8 9 Score along with a knife Gently snap off the excess Snap off the two end tabs Slide the toekick onto the mounting rails either side and screw the toekick onto the bottom of tub on either side. Important! Do not overtighten screw.

4

ALTERNATIVE METHOD (b) - SECURE BY DRAWER REMOVAL 5 0b PULL THROUGH HOSES & PUSH INTO THE CAVITY b REMOVE THE LOWER DRAWER (x) optionally attach the two top mounting brackets To prevent kinked hoses, we recommend rotating the drawer counter-clockwise and resting it on its side after removal. 43 You can initially level the product 45 4 (00mm) 00 mm You can raise or lower the product by twisting the feet. Then take care when pushing the product into the cavity that you do not bend the feet. As you push product in, pull through hoses and cord, ensuring they don t get kinked or twisted. Press the release tabs in on either side and push back to release drawer from runners. Push drawer runners back in.

b SECURE TO THE CABINETRY ON THE SIDES 3b OPTIONALLY SECURE TO THE CABINETRY ABOVE 6 For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend leveling feet up to required distance by hand. To access the side brackets, you might have to push aside the insulation. After securing, ensure the sound insulation is repositioned correctly. (x) The top mounting brackets will only bend upwards a maximum of 3 8 (0 mm). x4 Hexagonal socket Ensure product is level and aligning with cabinetry. Secure using two pairs of formed brackets (use 5 8 (6 mm) screws). Repeat on the other side of the chassis. 4b REFIT THE DRAWER ONTO THE RUNNERS Pull forward the release tabs on both sides 4 (00 mm) Ensure the drawer is now rotated clockwise back. 6 4 5 3 9 5 Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward. 3 Ensure the release tabs on both sides are reset fully. 4

5b FIT THE SUPPLIED TOEKICK PANEL (OPTIONAL FOR INTEGRATED MODELS) 7 Where the toekick meets the bottom of the tub is the cut-off point 3 5 7 Mounting rail 9 9 Lay the toekick face down on a chopping board or similiar Turn the toekick over and score along the same line Smooth the edge with a file. Be careful of sharp edges. Mark this point on the toekick with a pencil 4 6 8 9 Score along with a knife Gently snap off the excess Snap off the two end tabs Slide the toekick onto the mounting rails either side and screw the toekick onto the bottom of tub on either side. Important! Do not overtighten screw.

INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS 8 6 REMOVE BRACKETS FROM PRODUCT WARNING! Electrical Shock Hazard Before continuing, ensure that the product is disconnected from the power supply. 7 ATTACH PANELS TO PANEL BRACKETS 5 8 (6mm) x6 x6 There must be at least 3 screws used each side Failure to follow this warning may result in electrical shock, injury or fire. Important! Break off and discard the tab at the top of the Lower Panel Bracket. 3 3 Align bottom of panels with bottom of brackets 8 GROUND THE PANELS 9 ATTACH PANELS TO PRODUCT Important! Ensure the rubber seal between the drawer and panels is kept in place. WARNING! Electrical Shock Hazard Repeat for the other drawer Repeat for the other drawer To ground (earth) the panel bracket, connect the ground (earth) wire from the product to one of the tabs. Any custom metal component (e.g. handle) that extends past the rubber seal must be grounded (earthed) too. Failure to follow these warnings may result in electrical shock, injury or fire. When refitting the door pins, ensure they are orientated as shown.

INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS 9 0 ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS FITTING A CUSTOM TOEKICK PANEL 6 5 8 (6mm) x5 x5 + or - 6 ( mm) With the front panels fitted, insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panels up or down to align the gaps in your cabinetry. Repeat on the other side if necessary. You can optionally glue your custom toekick panel onto the supplied panel Each panel has a maximum travel of 6 ( mm) up or down. Important! Ensure that you maintain a minimum of 5 6 (8 mm) ventilation gap between the upper and lower panels.

THERE ARE THREE DIFFERENT DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. Dishwasher and Standpipe Ø ½ (38 mm) Dishwasher using Air Break with Drain Hose Joiner Dishwasher using sink trap with drain hose joiner 0 If space is limited for fixing, push hose through drain hose support to required height Supplied drain hose joiner Ø ¾ (9 mm) waste tee If space is limited for fixing, push hose through drain hose support to required height max. 0 4¾ (0mm) 750-88.5 9 ½ -34 ¾ mm (750-88.5 mm) 3 9 750-88.5 ½ -34 ¾ mm (750-88.5 mm) 38 ½ mm (38 mm) 9½ -34¾ (750-88.5 mm) 37 3 8 (950 mm) Max. height to top of Air Break see 3* see 3* see 3* 9½ -34¾ (750-88.5 mm) HIGHLOOP min. 6 (50 mm) min. R 8 (00 mm) min. R 8 (00 mm) min. R 8 (00 mm) CONNECT INLET HOSE TO * HOT WATER 3 4 Tighten coupling with wrench. SWITCH PRODUCT ON Ensure drain hose is routed straight to joiner. Remove excess drain hose material if necessary. Do not shorten the inlet hose. Ensure the supplied rubber washer is fitted inside the coupling. 80 o No leaks! 3 4 Important! Ensure that drain connection will comply with local plumbing regulations.

5 FINAL CHECKLIST 6 TROUBLESHOOTING Check all parts are installed. Ensure product is level, securely fastened to the cabinetry and opens and closes freely. The drawers must be free to fully close with no resistance from the cabinetry. Ensure inlet hose to water supply has supplied rubber washer fitted, and that it s tightened a further half turn after seal contact. Ensure any knockouts or plugs in drain connection have been drilled out and drain connection has been made. The drain hose joiner must not support the weight of excess hose material. Keep drain hose as fully extended as possible to prevent sagging. Any excess length of drain hose should be kept on the dishwasher side of the highloop. If connecting the drain hose to the sink trap, ensure the Highloop is a minimum 6 (50 mm) higher than the drain hose joiner. Ensure any packaging or tape securing the racks is removed from the drawers. Turn on the power and water supplies, then open the drawers. You should hear a beep and see a program indicator light up on the internal control panel. Check the spray arms are in place and free to rotate. Spray arm Add three cups of water into each drawer. Press on the internal control panel until the indicator of the Rinse program lights up. Close the drawers and press to start the program. After the Rinse program has finished, ensure the dishwasher has run and drained correctly. Check water supply and drainage connection for leakage. Excessive water remaining above the filter plate, after the rinse cycle Check for a kinked drain hose or blocked waste connection, highloop not properly installed or drain hose not routed correctly. No water supply (This is displayed as a U fault -- see section If there is a fault in the User guide for how to recognise this fault on models without a display.) Check water is connected and turned on. The dishwasher is beeping continuously There is a fault. See section If there is a fault in the User guide for further information and instructions. No program indicator lights up when the drawer is opened Ensure power is connected and is switched on. If it is and still no indicator lights up, see the Preference options section of the Quick start guide. An option called Open drawer auto power-on may need to be turned on. Water around water supply and drainage connections Check connections, existing plumbing and hoses for leaks. Check rubber washer and hose clamp are correctly fitted. If product is tipping Ensure the product is secured to the cabinetry. If front panels are misaligned Check and relevel product. Check the cabinetry is square. For Integrated models, check and adjust front panel alignment if necessary. Drawer doesn t close properly Ensure nothing is obstructing the drawer from closing properly eg sound insulation, hoses or drawer latches. If a problem occurs, consult the Troubleshooting section of the User guide. If after checking these points you still need assistance, please refer to the Service & Warranty book for warranty details and your nearest Authorized Service Center, or contact us through our website, listed below. Important! SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our website listed at the end of this document or contact your local Fisher & Paykel dealer. www.fisherpaykel.com