A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Universal Connectivity Platform A Modular Approach to Infrastructure Design

MT-RJ Optical Fiber System Field Testing

SECTION TESTING OF FIBER OPTIC CABLES

5. Identification products.

SECTION COMMUNICATIONS HORIZONTAL CABLING

Fibre (TIA) Field Test Specification

CATEGORY 6A FTP RJ45 SOLUTION

Fiber Optic Products Catalog

4120 Fire Alarm Network Reference

A. The requirements of this Section and the other Division 26, 27 & 28 Sections apply to all the video surveillance system work.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Jan07 Rev B

FiberExpress Solutions

Telecommunications Addendum APPLICATION FOR CLASSIFICATION/TELECOMMUNICATIONS

Standards and Procedures. Installation of Cameras and Camera Systems At University of North Carolina at Wilmington UNCW

CONSTRUCTION MANUAL PART 4

350 Pine Street, Suite 720 Edison Plaza Beaumont, TX Fax

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Special Provision No. 683S28 December 2017

commercial-type cabling and connectivity products into the industrial landscape.

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Design Requirements Provide work area copper cable (CAT-5 or CAT-6) in accordance with TIA-568-2, with a thermoplastic jacket colored as follows:

PART 1 CHANGES TO SPECIFICATIONS

Qualification Test Report LC Duplex Adapter For LC Cutouts

About Us. Who We Are Our Mission Our Products USA DAVIS LEGEND. Chicago

NG4access ODF Platform Standard Chassis Installation Manual

a. Design or design review of Voice, Data, and Wireless systems b. Copper cable manufacturer selection for new buildings and large scale renovations.

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

SECTION INTRUSION DETECTION SYSTEM

Telephone and Data Structured Wiring

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

4.0 FIBER OPTIC CONNECTIVITY

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

SECTION INTRUSION DETECTION A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

Connecting and Routing the Cables

TE Connectivity's AMP NETCONNECT Cable Management

LCS 2 YOUR digital infrastructure

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

Telecom Applications Management

The Next Generation of Data Communicatons Solutions

PRO-WATCH NOTIFIER SECONDARY FIRE INTERFACE ARCHITECT AND ENGINEERING SPECIFICATION

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION ISOLATED POWER SYSTEMS

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

Apr06 Rev A

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Web Pages for Construction and Traveler Information Condition Reporting System 511 Phone Power. Data Processing and Response Formulation

Fiber Optic Distribution Cables (6-144 Fibers)

SECTION PUBLIC ADDRESS SYSTEMS

Optional Parts (sold separately): E-4WNSC-x 4-Wire Non-Sensing cable (available in lengths 10/25/50/100 feet and custom lengths up to 1000 feet)

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

DOOR MONITORING/DURESS SYSTEM

Telecommunications Survey

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION (16140) - WIRING DEVICES

Unity Board Micro Air Corporation Phone (609) Route Allentown NJ Fax (609)

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Mar11 Rev B

NAME OF WORK - IIM AHMEDABAD - LIBRARY BOQ OF ELV WORKS Item #

Cat 6 Shielded Patch cords

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION AIR DUCT ACCESSORIES

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

California Polytechnic State University ITS Telecommunications PART 1 GENERAL 1.01 DESCRIPTION 1.02 QUALITY ASSURANCE

A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section.

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Telecommunications Standards Document February

Compact Module. Category 6A FTP Cabling System 1.1

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

ADDENDUM NO. 1 COPPER COMMUNICATIONS CABLE AND VOICE AND DATA EQUIPMENT MONITORING, TESTING, AND REPAIR DEPARTMENT OF WATER RESOURCES

Universal Connectivity Platform

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

Brochure. Security Designed, Installed by Experts

CLARIFICATION, QUESTIONS AND RESPONSES Clarification

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

DIXON UNIFIED SCHOOL DISTRICT DIGITAL INTERCOM / CLOCK & BELL SYSTEM

Fiber Optics. VIS / NIR Multimode, Feedthroughs. Ultrahigh Vacuum CF Flange Feedthrough. 4 x 1 CF Flange Feedthrough

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Cat 6 Unshielded Patch cords

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

HELKAMA. Optical Fibre Cables

SECTION NURSE CALL SYSTEM

IFS SFP Tranceivers User Manual

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

/Oct/2014 Rev E

Transcription:

SECTION 27 16 19 COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated or to be incorporated in such construction and all services, facilities, tools and equipment necessary or used to perform and complete such construction. The work of this section shall include, but is not limited to, the following: 1.02 QUALITY ASSURANCE 1. Patch Cords, Station Cords, Fiber Optic Patch Cords and Crossconnect A. Refer to Section 27 00 00 for general details. B. As noted in Section 27 00 00, all contractors and installers working on structured cabling system elements must hold a current manufacturer s certification for each individual component they install. 1.03 CODES, STANDARDS, AND GUIDELINES A. Except as modified by governing codes and by the Contract Documents, comply with the applicable provisions and recommendations in Section 27 00 00. 1.04 SUBMITTALS A. Refer to Section 27 00 00 for general details. B. Shop Drawings: 1. None Required C. Submit Manufacturer s Cut Sheets for the following: 1.05 IDENTIFICATION 1. Any products not specifically listed in the PRODUCTS section shall require a submittal of the manufacturer s cut sheets. A. None Required 1 of 9

1.06 DEFINITIONS A. N/A 1.07 WARRANTY A. Provide a complete channel solution incorporating Patch Cords, Station Cords, Fiber Optic Patch Cords and Crossconnect to meet structured cabling system warranty requirements. B. Refer to Section 27 00 00 for general details. 2 of 9

PART 2 PRODUCTS 2.01 PRODUCT CONSISTENCY A. Product Consistency: Any given item of equipment or material shall be the product of one manufacturer throughout the facility. Multiple manufacturers of any one item will not be permitted, unless specifically noted otherwise. 2.02 STANDARD COPPER CORD COLORS A. Category 6A Patch Cords (Telecom Room) White B. Category 6A Patch Cords (Patch Panel) White C. Category 6A Station Cords (User End) Spring Green D. Category 6A Station Cords (A/V Connections) Orange 2.03 COPPER PATCH CORD A. Category 6A Patch Cords (Telecom Room) 1. Patch cords shall route from equipment rack to wall-field. 2. For connection with modular components, provide a 4-pair patch cord with 110 reverse-direction plug on one end and an 8-pin RJ45 plug on other end. d T568B on both ends. 3. The cord shall be of solid wire construction, and shall be available in one (1) and four (4) pair configurations. 4. The cord color shall be white, and available as a standard color from the manufacturer. 5. Patch cords with shall have integral anti-snag feature on the RJ45 connector tab. 6. Shall be available in 10, 12, 14, 16, 18, 20 foot lengths. Lengths will be specified by the campus telecommunications representative. Custom lengths shall also be available, but only factory manufactured patch cords are acceptable. 7. Manufacturer/Product: Commscope Part#: VP360T-360GS10E-WH B. Category 6A Patch Cords (Use Where Patch Panels Are Specified) 1. Patch cord shall route from patch panel to equipment. 2. Provide 8-position/8-conductor modular RJ45 type plugs compatible with industry standard modular jacks. d T568B on both ends. 3. The cord shall be constructed of solid conductor copper alloy. 4. The cord color shall be white, and available as a standard color from the manufacturer. 3 of 9

5. Patch cords with shall have integral anti-snag feature on the RJ45 connector tab. 6. Shall be available in 1, 3, 5, 7, 9, 15 and 25 foot lengths. Lengths will be specified by the campus telecommunications representative. Custom lengths shall also be available, but only factory manufactured patch cords are acceptable. 7. Manufacturer/Product: Commscope Part#: 360GS10E-WH C. Category 6A Station Cords (User End) 1. Route from station outlet to user workstation. 2. Provide 8-position/8-conductor modular RJ45 type plugs compatible with industry standard modular jacks. 3. The cord shall be constructed of solid conductor copper alloy. 4. The cord color shall be spring green, and available as a standard color from the manufacturer. 5. Patch cords with shall have integral anti-snag feature on the RJ45 connector tab. 6. Shall be available in 6, 15 and 25 foot lengths. Lengths will be specified by the campus telecommunications representative. Custom lengths shall also be available, but only factory manufactured patch cords are acceptable. 7. Manufacturer/Product: Commscope Part#: 360GS10E-GN D. Category 6A Station Cords (A/V Use) 1. Route from A/V outlet to A/V equipment. 2. Provide 8-position/8-conductor modular RJ45 type plugs compatible with industry standard modular jacks. 3. The cord shall be constructed of solid conductor copper alloy. 4. The cord color shall be orange, and available as a standard color from the manufacturer. 5. Patch cords with shall have integral anti-snag feature on the RJ45 connector tab. 6. Shall be available in 3, 5, 15 and 25 foot lengths. Lengths will be specified by the campus telecommunications representative. Custom lengths shall also be available, but only factory manufactured patch cords are acceptable. 7. Manufacturer/Product: Commscope Part#: 360GS10E-OR 4 of 9

2.04 STANDARD FIBER OPTIC CORD COLORS A. Single Mode Fiber Optic Patch Cords Yellow B. Multi Mode Fiber Optic Patch Cords Aqua C. Fire Alarm Fiber Optic Patch Cords Purple D. Building Systems Fiber Optic Patch Cords Blue 2.05 FIBER OPTIC PATCH CORDS 1. Unless otherwise noted all fiber patch cords: a. All singlemode shall be zero water peak singlemode fiber. b. All multimode shall be OM4, 50 μm multimode fiber. c. Diameter over Jacket shall be 3mm. d. All connectors shall be LC unless otherwise noted. e. All patch cords shall be duplex B. Single Mode Fiber Optic Patch Cords (Yellow Jacket) 1. Manufacturer/Product: Commscope Part#: FEWLCLC52 C. Multi Mode Fiber Optic Patch Cords (Aqua Jacket) 1. Manufacturer/Product: Commscope Part#: FEXLCLC52 D. Multi Mode Fiber Optic Patch Cords for Fire Alarm (Violet Jacket) 1. Shall be available with ST connectors LC connectors and SC connectors. Verify with campus representative for installed requirements. 2. Submit product cut sheet. E. Multi Mode Building Systems Fiber Optic Patch Cords (Blue Jacket) 2.06 CROSS CONNECT WIRE 1. Shall be available with ST connectors LC connectors and SC connectors. Verify with campus representative for installed requirements. 2. Submit product cut sheet. A. Standard Telephone Crossconnect 1. 1 pair 24 AWG solid bare copper conductors, twisted pair, PVC insulation. 5 of 9

2. Available in a 1000Ft roll. 3. Manufacturer/Product: Belden XCB1 D871000 (White/Blue) B. Emergency Telephone Crossconnect 1. 1 pair 24 AWG solid bare copper conductors, twisted pair, PVC insulation. 2. Available in a 1000Ft roll. 3. Manufacturer/Product: Belden XCB1 D871000 (White/Red) 6 of 9

PART 3 EXECUTION 3.01 GENERAL A. Copper patch cords are not to exceed 25 feet in length. 3.02 QUANTITIES A. Quantities of system elements shown on the drawings are illustrative only and are meant to indicate the general configuration of the work. The Contractor is responsible for providing the correct quantities of materials to construct a system that meets the intent of these Specifications and the relevant codes. B. Category 6A Patch Cords (Telecom Room) 1. Provide a Category 6A patch cord for 40% of total terminated Category 6A cables in the building. C. Category 6A Patch Cords (Use Where Patch Panels Are Specified) 1. Provide a Category 6A patch cord for each terminated Category 6A patch panel port in the building. D. Category 6A Station Cords (User End) 1. Provide a Category 6A station cord for 40% of total terminated Category 6A cables in the building. E. Category 6A Patch Cords (A/V Use) 1. Provide two Category 6A A/V station cords for each terminated Category 6A cable in the building. F. Single Mode Fiber Optic Patch Cords 1. Provide four LC/LC 6 ft. SingleMode Duplex Patch Cords per telcom room. 2. Provide two LC/LC 10 ft. SingleMode Duplex Patch Cords per telcom room. 3. Provide two LC/LC 25 ft. SingleMode Duplex Patch Cords per telcom room. G. Single Mode Fiber Optic Station Patch Cord 1. Provide two single mode fiber optic patch cord for each fiber optic station cable location. 7 of 9

H. Multi Mode Fiber Optic Patch Cords 1. Quantity will be provided by campus telecommunications representative. I. Multi Mode Fiber Optic Station Patch Cords 1. Provide two multi mode fiber optic patch cords for each fiber optic station cable location. J. Fire Alarm Fiber Optic Patch Cords 1. Quantity will be provided by campus telecommunications representative. K. Building Systems Fiber Optic Patch Cords 1. Quantity will be provided by campus telecommunications representative. L. Cross Connect 3.03 INSTALLATION 1. Provide one roll of one pair white/blue telephone crossconnect wire, and one roll of one pair white/red emergency telephone crossconnect wire per telecom room. A. Installation to be done by campus personnel. B. Materials in this section are to be delivered to the main telecommunications room for distribution by campus personnel. 3.04 GROUNDING & BONDING 3.05 TESTING A. None Required B. Refer to Section 27 05 26 for additional details. A. All fiber optic patch cords shall include factory test results. B. Contractor shall perform channel testing on 5% of the supplied patch cords. These results should be documented separately formatted according to Section 27-08-13. 3.06 ACCEPTANCE A. Once testing has been completed and the campus telecommunications representative is satisfied that quantities are in accordance with the Contract Documents, the representative will notify the Contractor and/or campus project manager in writing or via email. B. Both Contractor project manager and campus representative signatures verifying quantity of receivables 8 of 9

have been delivered. 3.07 RECORD (ASBUILT) DRAWINGS A. None Required END OF SECTION DOCUMENT VERSION CONTROL REVISION DATE AUTHOR REASON 1 08/07/2012 C. WHITEHOUSE INITIAL DOCUMENT CREATION 2 02/21/2013 CJW & CLC PRIMARY REVIEW COMPLETE 3 10/09/2014 CJW & CLC YEARLY UPDATE AND REVISIONS 4 08/31/2017 MAS&CLC DRAFT 2017 REVISIONS 5 09/19/2017 MAS&CLC 2017 REVISIONS COMPLETE 9 of 9