Alpha Analyst. Integrated Alpha Spectrometer. Radiation Safety. Amplified.

Similar documents
Alpha Spectroscopy. Vacuum Light. Important things to know before you load your samples:

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

CEIA THS/PH21. series HIGH PERFORMANCE PHARMACEUTICAL METAL DETECTION SYSTEMS. Superior and Consistent Detection Enhanced Product Throughput Rate

CEIA THS/PH21. series. High Performance Pharmaceutical Metal Detection Systems. Superior and Consistent Detection

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

C-NRPP Quality Assurance Guidance for Radon Test Devices

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

L CONNECTION NETWORK Commercial Controls

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

ELD500 PRECISION LEAK DETECTOR

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Compact Product Suite Compact HMI 6.0 Overview ABB

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Technical specifications of FT-IR Spectrometer

Dry Contact Probe DCP (#30008)

Architectural and Engineering Specification for a Security Management System. StarNet 2

MDS. Multi-Detector a/b Counting System. Key Features

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Radiation Monitoring System RMS

LAUNDRY MONITORING SYSTEM Model # LIM-64S

ß-Aerosolmonitor FHT 59 C

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Power Flame Incorporated

SECTION Free/Available Chlorine Analysis System

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

300/400 UNITS - MODULAR CONFIGURATION

Med Touch Combination Alarm Conversion Kits

Omniguard 4: Features

Temperature Data Logging

NGC-20 LOCAL CONTROL CENTRAL MONITORING

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

ARCHITECTURAL AND ENGINEERING SPECIFICATION

THE FULL FORCED CONVECTION REFLOW SOLDERING SYSTEM SMT QUATTRO PEAK SERIES (FROM STO XLPLUS)

Technical Specification PILATUS 100K Detector System

Sensor Interface Module Installation/Operation Instructions

Environmental simulation chamber for complex alternating climate profiles

Instruction Manual. B Issue B. next Pump Accessories

T a b l e o f C o n t e n t s

Universal modular MWD platform adapted for your needs

P2267 NETWORK INTERFACE

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

Integrated Process Solutions. Series 49. Thermal Management System

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

LaserFOCUS VLF-250 Engineering Specification

SECTION Fluorescent Dissolved Oxygen Measuring System

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

OVEN INDUSTRIES, INC.

Flexibility. adjusted to specific needs of a client.

CEIA THS 21 series INDUSTRIAL METAL DETECTION SYSTEMS. Superior Detection Capabilities. Maximum Configurability

Pressed pellets. Liquids, Slurries. Loose powders, Rocks, Granules. Metal cuts, Solids. Fused beads. Small parts. Coatings, Foils

North American Technical Services

Tri-Tech Medical Inc.

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

IntesisBox BACnet/IP Server - Notifier ID3000 series

A New Standard of Excellence

PRODUCT REVIEW Honeywell HC900 Hybrid Vacuum Furnace Control System

Quick Alert Remote (QA216R)

Access Professional Edition. The flexible access control system that grows with your business.

Measurement Devices. Topic 5 - Audio 56

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

Technical Specification and Operating Procedure PILATUS 300K

Variable Temperature Microprobe Systems

Model gffoz Process Ozone Sensor (In-Line)

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

Substation Monitoring System

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

STEAMPAK Series BurnerPAK BMS Burner Management Systems

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

Environmental Radiation Monitoring System

Measurement system for detection of Radon in building

Silicon Detectors Passivated Implanted Planar Silicon (PIPS ) Detectors for Industrial Applications and Physics Research OEM VAR

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

ACCESS Master MT9085 Series. Product Introduction

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

MicroTech Series 200 Centrifugal Chiller

CO 2 Laser. High Reliability and Performance

Added password for IP setup page : Password must be in IP format!

Transcription:

Radiation Safety. Amplified. Alpha Analyst Integrated Alpha Spectrometer Table Top Nuclear Healthcare Homeland Security & Defense Labs and Education Industrial and Manufacturing Cabinet KEY FEATURES Completely integrated alpha spectroscopy instrument 100% computer controlled electronics and vacuum Automatic recoil suppression control Modular for ease of expansion Straightforward sample oriented graphical user interface Clean vent port to reduce moisture and contamination buildup in chambers Extensive QA record keeping built in Connects directly to Ethernet network Optional calibration services and startup DESCRIPTION CANBERRA s Alpha Analyst along with Apex-Alpha software is the complete solution for both routine and non-routine alpha spectroscopy applications. This flexible Alpha Spectroscopy System is designed to operate the way you do whether that s counting samples in a production batch mode environment or one sample at a time in a research type environment. TURNKEY PERFORMANCE The Alpha Analyst is a turnkey instrument solution from CANBERRA. It is available with a full suite of integration, installation, calibration, training, and consulting services that let you begin productive sample counting soon after set up. Traditionally, the user of an alpha spectroscopy system might spend large amounts of time integrating components, setting up hardware and software, building analysis procedures, calibrating, training operators and writing standard operating procedures. With the Alpha Analyst and the full suite of calibration services performed by a trained expert, the instrument will be ready to begin processing samples in only a couple of days. COMPLETE COMPUTER CONTROL CANBERRA s Alpha Analyst uses Apex-Alpha lab productivity software. Apex-Alpha is the ultimate alpha spectroscopy software package for automating Alpha Analyst detector setup and calibration, quality assurance, sample analysis and reporting activities in large or small alpha spectroscopy laboratories. This software package brings the productivity gains to alpha spectroscopy that the Apex Lab Productivity Suite has brought to gamma spectroscopy for a number of years. With Apex-Alpha, the complete status of your alpha analyst is available at a glance. Click and find all the batches waiting to be counted. Log samples into the system from any location where the information is known, such as from the radiochemistry laboratory or other sample log-in area. Let Apex- Alpha enforce your calibration /QA schedules and monitor QA results and automatically take the appropriate action if something goes wrong. www.canberra.com

The integral instrument controller unit coordinates all operations on an Alpha Analyst including: instrument setup, automatic pumping and venting of spectrometers, data acquisition, control and the monitoring of the status of each spectrometer. Computer control of the front end electronics eliminates any knobs to turn or buttons to push so the possibility of tampering or accidental settings modification is eliminated. Precise adjustment of all front end electronics is accomplished via Apex-Alpha. Data acquisition is continuously and automatically monitored during all aspects of instrument operation preventing any corruption of data due to vacuum loss. No longer will samples need to be recounted because the vacuum was lost 8 hours into a 16 hour count. The pressure of each individual chamber is independently and continuously monitored to verify correct operating conditions are established and maintained for data acquisition. Should the pressure in any chamber at any time during counting exceed the user defined limit, acquisition will be automatically suspended until the proper operating pressure is again attained, at which time the controller will continue the count. INTEGRATING YOUR LABORATORY CANBERRA s Alpha Analyst offers the same consistency of operation and flexibility offered with all Genie applications. The Alpha Analyst instrument makes use of an Ethernet based computer controlled MCA located in the Alpha Analyst Controller Unit. Because it is Ethernet based, the Alpha Analyst can be located and controlled from where it is convenient for your operation including client/server distributed architecture. Redundancy of operation is paramount in high volume applications instrument down time due to computer failure cannot be tolerated. The Alpha Analyst is totally integrated containing the detector signal processing and control electronics allowing instrument control from multiple clients. Instrument settings are maintained in Apex-Alpha ensuring the system integrity is maintained at all times. A complete copy of all instrument settings is maintained with each and every sample measurement, providing traceability for each measurement directly to the appropriate instrument setup and calibration. Vacuum management is accomplished entirely by the controller unit. There are no mechanical valves to manipulate simplifying the task of loading and unloading samples. The operator can concentrate on getting the samples counted and let the computer automatically manipulate the vacuum system to control venting, protecting acquiring chambers from inadvertent venting. Client/Server, 2-tier Configuration with Multiple Clients Apex-Alpha Application/DB Server Note: Application and Database can reside on different Servers for a 3-tier installation. Client Hot Lab Client Environmental Lab Desktop Configuration Client Sample Log-in or Data Review Multiple Benchtop Alpha Analysts or Manual Spectrometers 48 Total Inputs or One Complete Alpha Analyst Floor Cabinet Network Diagram 2

INTELLIGENT SOFTWARE Apex-Alpha provides full computer control of the Alpha Analyst and can also support manual spectrometers through Genie compatible MCA s. Apex-Alpha is also the replacement for Genie-ESP/AMS (Alpha Management Software) systems used for alpha spectroscopy. Apex-Alpha is available as both a Desktop version and a Client /Server version. Apex-Alpha uses a relational database (SQL Server 2008) for storage and retrieval of sample information/analysis results, log files, etc. and provides a comprehensive, but intuitive, user interface. Apex-Alpha provides simplified batch creation, simplified sample loading/assigning, automatic energy calibration, automatic efficiency calibration, and extensive QA capabilities. For more detailed information see the separate Apex-Alpha spec sheet. STANDARD OPERATING PROCEDURES The standardized instrument design of the Alpha Analyst eliminates the hours normally needed to write custom operating procedures specific to each user s application. Each instrument includes a complete set of operating procedures governing routine sample analysis QA checks, background collection and system calibration. Should the end user desire to customize these procedures, they are supplied in both printed and electronic formats. Apex-Alpha RECOIL CONTAMINATION PROTECTION Even with the most carefully prepared samples system operators cannot eliminate the possibility of contamination of the detector with recoil nuclei. This unwanted contamination leads to decreased measurement sensitivity and ultimately longer counting times until some detectors are eventually rendered useless. The Alpha Analyst includes recoil suppression as a standard feature on each instrument so that you can maintain consistently low backgrounds maintain sample throughput and extend the life of your alpha detectors. During instrument setup the user defines a desired air thickness (μg/cm 2 ) to maintain in the counting chamber during the measurement of samples. When samples are counted in the vacuum regulation mode the computer controlled vacuum system automatically regulates the operating pressure in each dual alpha spectrometer to within ±10% of the desired operating vacuum. This protective layer of air coupled with a +5 volt bias applied to the detector shell provides the ultimate defense from recoil contamination. 3

CLEAN VENT FEATURE In environmental applications requiring low sensitivity it is desirable to reduce or eliminate the introduction of radon and/ or moisture into the counting chambers during loading and unloading operations. The Alpha Analyst makes available the clean vent port, which allows for the chambers to be vented using (customer supplied) dry bottled air or nitrogen which is free of radon and its progeny. All chambers are connected to a common vent manifold, which is supplied with low pressure compressed air or nitrogen. When the counting chambers are vented for sample loading/ unloading the chambers are backfilled with this supplied gas and continuously purged while the chambers are open to atmosphere. PIPS DETECTORS CANBERRA s Passivated Implanted Planar Silicon (PIPS) detectors are a product of modern semiconductor technology whose performance surpasses that of traditional silicon surface barrier (SSB) type detectors and diffused junction (DJ) type devices. The PIPS detector has a number of advantages over the older technologies for room temperature detection of alpha particles. The electrical contacts on a PIPS detector are ion-implanted to form precise thin and abrupt junctions for good alpha resolution. The entrance window of a PIPS detector is stable and rugged and standard detectors are bakeable to 100 C. The leakage current a major contributor to detector noise is typically 0.1 to 0.001 that of SSB and DJ type detectors. The Model A450-18 AM is by far the most popular model detector for standard alpha spectroscopy but other sizes are also available. THE ALPHA ANALYST ON LEGACY VMS For users requiring capability with an existing OpenVMS - based operating system, the Alpha Analyst is also compatible with CANBERRA s legacy VMS Alpha Management Software (AMS). This allows existing AMS users to expand or upgrade and take advantage of the features available with the Alpha Analyst hardware particularly the 100% complete control recoil suppression mode and space saving design. ALPHA ANALYST MODULAR UPGRADES For users who have open space in an existing Alpha Analyst, CANBERRA offers the Model 7200 dual spectrometer as a costeffective way to increase capacity two chambers at a time. INSTALLATION AND STARTUP Traditionally, the purchase of a new instrument meant days or even weeks of set up and calibrations before you could count your first sample. The Alpha Analyst is provided with factory integration and testing. When the Alpha Analyst is purchased with the exclusive installation and calibration services you ll be counting samples in record time. The installation services include setup of the instrument at the customer s site, software installation, tailoring of the setup to site specific requirements and basic training on the overall operation of the instrument. A trained professional will assist with creation of nuclide libraries, calibration certificates, counting protocols, analysis sequence files and QA files. When the setup is completed your operators will know the basics of calibrations and sample counting. In addition to the installation services, the calibration and consulting options can be purchased for users who need to go beyond the basics of the installation services. Complete energy shape and efficiency calibrations will be performed on each detector. Instrument checks will be performed including detector backgrounds and pulser checks. When finished the instrument will be completely configured and calibrated and your trained operators will be ready to begin counting samples. 4

SPECIFICATIONS DUAL ALPHA SPECTROMETER MODULE MODULES Two vacuum chambers per Dual Spectrometer Module. VACUUM CHAMBERS Low background stainless steel; 8.26 x 6.03 x 6.35 cm (3.25 x 2.375 x 2.5 in.), H x W x D. SAMPLE SIZE Up to 51 mm (2.0 in.) in diameter. SAMPLE-TO-DETECTOR SPACING 1 to 45 mm in 4 mm increments. MAXIMUM DETECTOR SIZE 1200 mm 2. VACUUM GAUGE Vacuum monitoring of each Dual Alpha Spectrometer Module is performed by the respective module s processor; read out by the host computer. VACUUM RANGE 0 to >26.7 kpa (0 to >200 Torr). VACUUM/BIAS INTERLOCK The Dual Alpha Spectrometer Module will turn on the bias when a vacuum level of <10 kpa (<75 Torr) is reached. EMERGENCY VENTING Manual vent screw to vent both chambers of a Dual Alpha Spectrometer module, in the event of a communications, computer or power failure. Located on the valve block on the rear panel of the module. BIAS SUPPLY Bias control for each Spectrometer Module; the bias for both Detectors/Chambers on a Spectrometer Module is set identically; controlled through the host computer; adjustable in 1 V increments from 0 to 100 V. DETECTOR LEAKAGE CURRENT MONITOR 4 na to +2500 na range; read by the host computer. REFERENCE PULSER Each chamber in a Spectrometer Module has its own independent pulser. The pulsers associated with all Spectrometer Modules are synchronized, allowing up to 48 chambers to be QA checked simultaneously. FREQUENCY 40.69 Hz. FREQUENCY STABILITY ±50 ppm. RANGE 0 to 10 MeV; limited by system threshold to 70% of full range; computer controlled. ADJUSTMENT RESOLUTION 12 bits (2.5 kev granularity). AMPLITUDE DRIFT <±100 ppm / C. LONG TERM DRIFT <±0.005% of full scale / 24 hours at constant temperature. SPECTROMETER PERFORMANCE Based on use of a 450-18AM PIPS detector with a good quality 241 Am point source. ENERGY RESOLUTION <18 kev (FWHM) with a detectorsource spacing equal to the detector diameter. DETECTOR EFFICIENCY >25% for detector-source spacing of less than 1 mm. BACKGROUND <1 count/hr above 3 MeV. RECOIL SUPPRESSION SUPPRESSION BIAS +5 V continuously applied to detector shell to repel recoil contamination. Detector bias is applied with respect to +5 V detector return. REGULATION Nominal programmed pressure ±10%. PRESSURE RANGE 0.13-2.67 kpa (1-20 Torr), corresponding to air thickness of approximately 12 to 16 g/cm 2 and detector-sample spacing of 5 mm to 45 mm. SPECTROMETER OPERATIONS Performed through the host computer and Alpha Analyst software. SYSTEM LLD Fixed at 0.5 volt. MCA SPECTRUM SIZE 4096, 2048, 1024, 512, or 256. MCA MEMORY CAPACITY For all ADC ranges, the capacity is 32 bits/channel (>4 x 10 9 counts/channel). DATA RETENTION 20 years of power loss. PRESET MODE Individual presets for each Spectrometer; True or Live Time, multiples of 1 second: max preset > 4x10 7 seconds; composite DT for all Spectrometers within a single chassis (live time correction factor is the same for all Spectrometers within a single chassis). CONTROL INTERFACE Ethernet AIM protocol, 802.2/802.3 compliant; Ethernet (RJ-45) built in. RS-232 INTERFACE Provided as a diagnostic port. INDICATORS INITIALIZATION At power on, all LEDs will blink at a high rate during the first part of the initialization sequence, then go off momentarily during the self check, after this, the Fault LED will blink slowly until communication is established with the Host. DUAL ALPHA SPECTROMETER INDICATORS Four LED indicators report the operational status of each Dual Spectrometer Module. ACQUISITION A and ACQUISITION B Green LEDs. On: chamber acquiring; Off: chamber not acquiring; Blinking: chamber available for loading or unloading. VACUUM Yellow LED. On: chamber is in operating vacuum range; Off: chamber is vented; Blinking: adjusting chamber pressure. FAULT Yellow LED. Vacuum Pressure has been below the alarm threshold for 1.5 seconds or Vacuum Gauge Fault, indicating a possible valve problem. CONTROLLER INDICATORS Two LEDs indicate the status of the Controller. FAULT Yellow LED signals that a command error or vacuum control error has occurred. After power on initialization completes the LED will blink until the HOST has established communication with the Controller. POWER Green LED indicates controller has power. COMMUNICATION STATUS INDICATORS Three LEDs indicate status of the communication link between the Host and the Controller. 5

INDICATORS (continued) IN USE Yellow LED indicates that the Host has established communication with the Controller. COMM TX Yellow LED indicates the interface is sending data to the Host via the Ethernet port or to the diagnostic RS-232 port. COMM RX Yellow LED indicates the interface is receiving data from the Host; during Power-On Self Test, it can indicate an Ethernet network error. CONNECTORS DETECTOR Axial microdot. DIAGNOSTIC RS-232; rear panel 9-pin male D-connector. ETHERNET RJ-45 jack provides connection to network through 10 Base-T and 100 Base-TX transceivers. CHASSIS POWER CONNECTOR Provides +5 V dc, ±15 V dc, and 115 V ac; flying cable, terminated in a 15-pin D-connector. CONTROLLER POWER CONNECTOR Provides +5 V dc and ±15 V dc; rear panel 15-pin D-connector. AC LINE CONNECTOR Line entry module with integral IEC connector to accept compatible line cord. INPUT POWER SELECTIONS 100-240 V ac Selectable, via fusing in the Power Entry Module, as follows: Nominal 100 V; Nominal 120 V; Nominal 230 V; Nominal 240 V; 50/60Hz; 121 W for a Model 7200-12 Alpha Analyst populated with six Dual Alpha Spectrometer Modules. PHYSICAL DIMENSIONS Benchtop instruments: 52.1 x 43.8 x 65.4 cm (20.5 x 17.25 x 25.75 in.) W x H x D. WEIGHT 63.5 kg (140 lb) for a 7200-12 Alpha Analyst populated with six Dual Alpha Spectrometer Modules. ENVIRONMENTAL OPERATING TEMPERATURE 0 to 50 C. OPERATING HUMIDITY Up to 95%, non-condensing. Tested to the environmental conditions specified by EN 61010, Installation Category I, Pollution Degree 2. ORDERING INFORMATION To fully configure a benchtop Alpha Analyst Workstation, select the appropriate Alpha Analyst instrument, PIPS detectors, software, vacuum pump and, if applicable, a PC. Also highly recommended is the optional suite of startup services. Models: 7200-XX (available from 2 to 12 input, in multiples of 2) Detector: A450-18 Alpha PIPS, or other appropriate size Vacuum Pump: 7400-01 115 V, 60 Hz, or equivalent S770C Apex-Alpha Desktop License Requires Genie 2000 packages S771C Apex-Alpha Server License Requires Genie 2000 packages and SQL Server 2005 S772C Apex-Alpha Client License Requires Genie 2000 packages (or S520) S775C Apex-Alpha Desktop/Genie 2000 Package Includes Genie 2000 packages S775M Apex-Alpha/G2K Desktop Migration Package Requires existing Genie 2000 licenses listed above plus the S570C Alpha Analyst Control Software which is also included in Model AASW-G2 Includes updates to Genie 2000 media MINIMUM COMPUTER REQUIREMENTS PC Consult Factory ACCESSORIES 7400-10 Replacement Vacuum Filter Cartridges 7400-17 Exhaust Filter Kit 7400-SRC Mixed Alpha Standard Source 7400-19 ISO (16) Flange Adapter 7200 Dual Alpha Spectrometer Upgrade Module OPTIONS AA-INST Installations Services AA-OSCAL Calibration Services 556B-CONV 10BASE-2 to 10BASE-T Converter Alpha Analyst, Apex-Alpha, Genie, APEX and PIPS are trademarks and/or registered trademarks of Mirion Technologies, Inc. and/or its affiliates in the United States and/or other countries. 2017 Mirion 2076 Technologies Canberra (Canberra), Industries, Inc. All rights reserved. Copyright 2017 Mirion Technologies, Inc. or its affiliates. All rights reserved. Mirion, the Mirion logo, and other trade names of Mirion products listed herein are registered trademarks or trademarks of Mirion Technologies, Inc. or its affiliates in the United States and other countries. Third party trademarks mentioned are the property of their respective owners. www.canberra.com C40143-09/13