Molex Premise Networks Corporate Headquarters Harvard, MA Tel: Tel: Fax:

Similar documents
19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

Varistar LHX 3 Air/Water Heat Exchangers

Your roof is waiting for it PRODUCT CATALOGUE Podsufitki

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

DESIGN GUIDELINES. THERMAL building SOLUTIONS

Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

For more information on Tarkett go to

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Flat Stratton House Greywell Road Havant Hampshire PO9 5AH. Asking Price 115,000

Technical documentation DTR

Remote alarm indicator and test combination MK2430

Installation and Operating Manual

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Air curtain.

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

The warranty card and conditions are effective only in the area of Poland.

8/S1 AIR CURTAINS SONATA, SONATA-V. v 1.0 (en)

EARTH FAULT METER MD-08

COOL COMBINATION EQUIPMENT PROTECTION SOLUTIONS INDUSTRIAL ENVIRONMENTS

Universal fault annunciator for panel mounting

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

24 port 0.5U unpopulated FTP keystone panel with cable management bar

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Technical documentation

Low Temperature Radiator GB 01. Heating & Plumbing. Ideas to install

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

CONTROLS FOR ELECTRIC RADIATORS AND TOWEL RAILS

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

THERMASREG TR 040 THERMASREG TR 060

Single-side powered heating cables

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Water chillers water/water type SIGMA Technical information manual

Frost Protection Thermostat

WIO200 Water In Oil measuring instrument

MAESTRO 25. Range guide. Maestro 25. Desks Storage Screens. Your Office Furniture Wholesaler

Toll Free: Tel: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Gas heaters and convectors ROBUR

SCE170 SERVICE PARTS

Just feel well. 2017/2018 Air conditioning

PARTS BOOK. From S/N:

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

PARTS BOOK. From S/N:

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

Hi-Pres Cooling Products Catalogue. Product Catalogue

SDU A. SDU A Loops. (available in 3, 4, 5 loops) Water Based Systems. Standard Distribution Unit assembled with: A Blank Port (capped)

SCA 620C AIR COOLED SCREW CHILLER

NEW GREEN TECHNOLOGY

Hand Held Welding Guns

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Duct Temperature Sensors

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Budget (MFC) Melamine Face Chipboard (MFC) Adjustable Leg. Nylon Fittings. One-Size-Fits-All. Dry Application. Pilaster Lock.

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

2 Zone Kit code

L. Terminal block Connecting Label:

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

Ceiling diffusers. Type DLQL

BUYING GUIDE LILLÅNGEN. Bathroom furniture

Theory of Operation: M9/D & M11/D

ALARMLINE ANALOGUE Linear Heat Detection System

LABorAtory refrigerators

EHH SERIES DRAW THROUGH FAN COILS CFM

ALTO DRAWER SYSTEMS .hafele.com.au Dimensions in mm 2018 www

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Main technical datas:

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

BUYING GUIDE LILLÅNGEN. Bathroom furniture

HEATING SOLUTIONS WATERBED

E U R O V E N T CERTIFIED PERFORMANCE

Heatseeker Plus Solar Pool Heating

Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

ORIGINAL. 08/ Rapa Sp. J. The warranty card and conditions are effective only in the area of Poland.

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

A B C D E F 2

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Floor Mount Racks (Server Cabinet Type)

1.1 VTS: number 1 in the world pillars of success

Product Comparison Guide. EnOcean 868MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution

Caution: The fans must not be used in bath or shower enclosures.

OLUX LED IN-GROUND OSRAM. Datasheet

General Specifications

Auxiliary Equipment and Accessories

Reference list 2010 & 2011

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Exp, pressurized systems

Workbenches Tool carts Metal lockers.

RCV Installation and Operating Instructions

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Hi-Pres Cooling Products Catalogue

Transcription:

PRODUCT RELEASE BULLETIN: MODBOX II LE Cabinet Set Harvard, MA 01451 Tel: 800 866 3827 Tel: 603 324 0200 Fax: 603 577 8770 Hampshire, England Tel: 44 (0) 1489 572111 Fax: 44 (0) 1489 559106 Warsaw, Poland Tel: 48 22 836 92 51 Fax: 48 22 836 92 55 Asia New Territories, Hong Kong Tel: 852 2637 3759 Fax: 852 2647 1082 South Pacific Victoria, Australia Tel: 61 3 9971 7111 Fax: 61 3 9971 7199 Visit our Web site at 1999, Molex Incorporated

MODBOX II LE fan unit Fun units appropriated for mounting in standing MODBOX II LE Cabinets, ensure air exchange and protect mounted equipment from overheating. Top mounted units don t use operating space in 19 rack. RAA- 00100 fan unit kit contains four ventilators, control panel with power supply cord without power plug, mounting screws. RAA-00101 kit contains two ventilators, two blank elements, control panel with power supply cord without power plug, mounting screws. At the front side of control panel are placed on/off switch and electricity fuse. There is available Thermostat with mounting kit (RAA-00105), ordered separately, which turn fun unit on when set temperature will be surpassed. It s recommended to use Rack Cabinet Base Filtering Plate (99.X2550) in combination with fan unit to avoid dust suction. RAA-00100 RAA-00101 Voltage rating: 220/230V, 50Hz Nominal current [A]: 0.24 0.48 Nominal power rating [W]: 30 60 Air capacity [m3/h]: 320 640 Weight [kg]: 2.4 3.2 Ventilator: Voltage rating [V]: 220/230 Frequency [Hz]: 50 60 Nominal power rating [W]: 15 14 Nominal current [ma]: 120 100 Speed [min-1]: 2600 2900 Static pressure [Pa]: 75 90 Air capacity [m3/h]: 162 192 Overall dimensions [mm]: 112 x 112 x 38 Control panel: Overall dimensions [mm]: 44 x 483 x 55 Power supply cord length [m]: 2.3 RAA-00100 RAA-00101 Product name MODBOX II LE fan unit, 4 fan, without power plug MODBOX II LE fan unit, 2 fan, without power plug Sp. z o.o. Limited Asia Pacific.au reserves the possibility rights technic parameters changes

MODBOX II LE 42U 600x600? RAA-00092 19 MODBOX II LE Cabinet set 42U, 600x600 Sp. z o.o. Limited Asia Pacific.au reserves the possibility rights technic parameters changes

MODBOX II LE 42U 600x800 1. New low cost version of 19 MOD- BOX II cabinet, 600x800mm, 42U high. 2. There are available two Fan Units designed to mount in MODBOX II LE cabinets providing air exchange inside cabinet and cooling active equipment (MODBOX II LE fan unit, 4 fan, without power plug - RAA- 00100 and MODBOX II LE fan unit, 2 fan, without power plug - RAA- 00101). Fan units are sold separately. 3. Possibility of mounting Rack Cabinet Base Filtering Plate (99.X2550) protecting from dust suction (ordered separately). 4. Possibility of joining two MODBOX II LE Cabinets side by side with MODBOX II Sleeve Alone, 4pcs Kit (RAA-00084). 5. Cable entry from every side when MODBOX II Plinth used (RAA- 00102). 6. When four point fixing devices are to mount in cabinet, it s possible to buy separately two racks for cabinet and mount it inside cabinet building rear 19 rack (RAA-00103, RAA- 00104). 7. Standard equipment comprise: - Light, strength and rigid construction - Aesthetical, glazed front door with lock left and right opened - Removable lateral shields ensure easy access to the interior of cabinet - Hand controlled legs ensure level adjustment. - All parts connected to the grounding bar. - Cable entry from bottom and back. 8. Adjustable frame depth allow user to mount non-standard size equipment. Dimensions: Width [mm]: 600 Height [mm]: 2056 Depth [mm]: 800 Material: Cold rolling steel sheet Paint Coat: Graphite powder varnish (RAL 7011) Weight [kg]: 104 RAA-00095 19 MODBOX II LE Cabinet set 42U, 600x800 Sp. z o.o. Limited Asia Pacific.au reserves the possibility rights technic parameters changes

MODBOX II LE 24U 1. New low cost version of 19 MOD- BOX II cabinet, 600x600mm, 24U high. 2. There are available two Fan Units designed to mount in MODBOX II LE cabinets providing air exchange inside cabinet and cooling active equipment (MODBOX II LE fan unit, 4 fan, without power plug - RAA- 00100 and MODBOX II LE fan unit, 2 fan, without power plug - RAA- 00101). Fan units are sold separately. 3. Possibility of mounting Rack Cabinet Base Filtering Plate (99.X2550) protecting from dust suction (ordered separately). 4. Possibility of joining two MODBOX II LE Cabinets side by side with MODBOX II Sleeve Alone, 4pcs Kit (RAA-00084). 5. Cable entry from every side when MODBOX II Plinth used (RAA- 00102). 6. When four point fixing devices are to mount in cabinet, it s possible to buy separately two racks for cabinet and mount it inside cabinet building rear 19 rack (RAA-00103, RAA- 00104). 7. Standard equipment comprise: - Light, strength and rigid construction - Aesthetical, glazed front door with lock left and right opened - Removable lateral shields ensure easy access to the interior of cabinet - Hand controlled legs ensure level adjustment. - All parts connected to the grounding bar. - Cable entry from bottom and back. 8. Adjustable frame depth allow user to mount non-standard size equipment. Dimensions: Width [mm]: 600 Height [mm]: 2056 Depth [mm]: 600 Material: Cold rolling steel sheet Paint Coat: Graphite powder varnish (RAL 7011) Weight [kg]: 62 RAA-00099 19 MODBOX II LE Cabinet set 24U, 600x600 Sp. z o.o. Limited Asia Pacific.au reserves the possibility rights technic parameters changes

MODBOX II plinth MODBOX II plinth, 600x600x100 is designed to co-operate with standing, 600x600mm MODBOX II LE Cabinets. Ensure excess cable storage and allows cables entry form four sides by rmoving blank panel. Graphite colour fix perfectly with grey cabinets. Dimensions: Width [mm]: 600 Depth [mm]: 600 Height [mm]: 100 Material: Cold rolling steel sheet Paint Coat: Graphite powder varnish (RAL 7011) Weight [kg]: 6.5 RAA-00102 MODBOX II plinth, 600x600x100 Sp. z o.o. Limited Asia Pacific.au reserves the possibility rights technic parameters changes

Racks Racks are designed to mount in MODBOX II LE Cabinets, which are equipped with front 19 only. Two additional racks installed in cabinet allow mounting of four point fixing device. Racks are not equipped with Rack Screw/CageNut/Washer Kit. Dimensions: Element Width Height Length [mm] [mm] [mm] RAA-00104 48 32 1067 RAA-00103 48 32 1866 Weight [kg]: RAA-00104: 1.54 RAA-00103: 2.70 Material: 2.0 mm thick cold rolling steel sheet RAA-00103 RAA-00104 Rack for 42U cabinet, 1 piece Rack for 24U cabinet, 1 piece Sp. z o.o. Limited Asia Pacific.au reserves the possibility rights technic parameters changes

Thermostat Appropriation of Thermostat with mounting kit is to control fan units installed into cabinet, it s simple regulator, which turn device on when set temperature is surpassed. Temperature range 0C to 60 C. Sensor element: termobimetal Temperature range [ C]: 0 60, hysteresis 7K Contact type: snap action contact Power carrying capacity: 6A (1) 250V AC Radio frequency interference: N according to VDE 0875 RAA-00105 Thermostat with mounting kit Sp. z o.o. Limited Asia Pacific.au reserves the possibility rights technic parameters changes