MODEL URS-1: FACTORY RETROFIT PROGRAM

Similar documents
URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

CAREL IR33+ CONTROLLER

Service Step by Step Trouble-Shooting Check-List

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

User Guide ems25plus. Page 1. Normal operation. Product interface

Service Manual. ETL Blast Chiller Series

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Otherwise, you can continue reading the file on the following pages.

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Service Manual. Solid Door Upright Reach-In Units:

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

ER52 - Evaporator Controller

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Hoshizaki America, Inc.

G&F Manufacturing Service Manual Version 2.0 April 2010

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

MasterCase. User Manual

Controlled Thaw Cabinets

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

Bottom Mount Refrigerator---Technical Information

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

Hoshizaki America, Inc.

Liebert CRV Warranty Inspection Check Sheet

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

TMEF Series. SKOPE Vertical Freezer. User Manual

INSTALLATION INSTRUCTIONS

WH7016E Thermostat Product Manual

Manual For Panel Air Conditioner. Table of Contents

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Split Floor-Mounted Cooling System Operation Care Installation Manual

HP50HA ABG Heat Pump

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom)

Condensing Unit Installation and Operating Instructions

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

INSTALLATION INSTRUCTIONS

HPXA15 HPXB15 WARNING

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Instruction Sheet. ERC2 Retrofit Instructions Series Refrigerators/Freezers and SPEC LINE Refrigerators 6000 & SPEC LINE SERIES

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

Instruction Manual. Pastry Display Cases. Models: JMR series REFRIGERATION LTD. JMRTP JMRWP JMRSP JMRPP

INSTALLATION INSTRUCTIONS

KR Electrical Defrost Unit Coolers (PN E108318_E)

Hoshizaki America, Inc.

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

Installation Manual BCS 1000/1500

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

User Guide. OPTYMA TM Control Three-phase AK-RC 103

Service Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

T-Series Air Conditioner T15 Model

ERC2 Control Instructions

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

plug-in, electronic digital thermostat with defrost control User manual

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLERS

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

OPERATING INSTRUCTIONS. G214 Software - Version 4

HEATING AND AIR CONDITIONING

OPERATION & MAINTENANCE MANUAL AC880

PL Series Premier Indoor Plenum Coils

MASTER SERVICE MANUAL

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

FX BLAST CHILLER ISO ISO 9001

IN NOURISHING SECURITY.

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

Dixell Installing and Operating Instructions release 7.0

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Follett Performance Plus

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

A Series Inertia Compressor Applications. Application Bulletin 115

Technical Information

Introduction. OM-THA2

MASS. MARITIME ACADEMY

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

REF Series Undercounter Refrigerator

Transcription:

MODEL URS-1: FACTORY RETROFIT PROGRAM The USR-1 unit has gone through extensive testing in order to attain maximum performance. It has been determined that in order to set the unit for all weather operation, a factory authorized retrofit is required. This retrofit service must be done by a qualified refrigeration mechanic or service technician in order to guarantee product performance. This retrofit service involves the following steps: 1. Refrigerant recovery. 2. Expansion valve orifice replacement (if needed) 3. Expansion valve superheat adjustment. 4. System evacuation. 5. System re-charging. 6. Controller re-programming. SERVICE PROCEDURE >>>DISCONNECT ALL POWER BEFORE PROCEEDING <<< STEP 1: Refrigerant Recovery The refrigerant in the URS-1 system needs to be extracted (recovered) out of the system in order to begin the retrofit service to the unit. To begin, start by removing the URS-1 rear access cover. Lift the back cover straight up to remove and locate the pressure ports as shown on Figure-1. : Suction Line Suction port Condenser Coil (clean if needed) Liquid Line Service Port (Filter port) Compressor service Port (process tube) Figure -1 1

Using a recovery tank or evacuation equipment remove the refrigerant out of the system using any of the high side (liquid side or process tube) ports as shown on Figure 2: Liquid Line Service Port (Filter port) Compressor service Port (process tube) Figure 2 STEP 2: Expansion Valve Orifice Replacement. The expansion valve in the URS-1 is a Danfoss brand TUA - type. This type of expansion valve allows the exchange and repair of the internal orifice (needle assembly) as well as it permits the size to be changed to allow for more capacity in refrigeration of the system. Starting in June 2005 the expansion valve orifice was changed from size 0 to size 1. All models with serial number 05-30060 or higher will have orifice 1 already installed. This change was not due to lack of capacity on the size 0 orifice but rather the side port diameter. Size 0 orifice has a very small side port that might become clogged by internal debris in the system (debris not picked up by the filter in the liquid line), that might hinder the valve s correct operation. Orifice size 1 on the other hand, has a much larger side port that will not get clogged by system debris if any. Once the system s refrigerant has been recovered as shown on STEP 1, you can begin to replace the expansion valve orifice. Locate the evaporator cooling coil inside the refrigerator product area. (See Figure 3) Evaporator Cooling coil cover Figure 3 2

Remove the side wall pilaster support screws (shoulder hex screw) and the evaporator cover by removing the two top screws of the assembly. You should be able to see two fans, the evaporator coil, TXV bulb and expansion valve. (see figure 4) Fan Plenum Screws Fans Coil TXV TXV Bulb Figure -4 Remove the fan plenum screws in order to reach the expansion valve. (see figure 5) TXV Liquid Line TXV Orifice Coil Fan Figure 5 3

Locate the Danfoss TUA Orifice # 1 cartridge (Included in your Retrofit Kit - Figure 6) and verify that the orifice already installed in the expansion valve is TU 0 (Figure 5 - detail). Should the existing orifice be TU 0, replace with TU 1 If the existing orifice is TU 1, DO NOT REPLACE DO NOT REMOVE. If the orifice is loosened or removed it requires a new aluminum washer. The sealing washer is a one-time-use component or failure to seal properly will lead to refrigerant loss and system discharge. (See figure 7, 8 and 9) Needle Shipping Casing Label TXV Orifice Gasket Figure 6 Figure 7 Figure 8 Label: TU 1 68U1031 (Danfoss Part #) xxxx (lot #) Figure 9 Once the orifice has been replaced, re-install the fan plenum as shown on figure 4. STEP 3 : Expansion Valve Superheat Adjustment In order to adjust the system to operate correctly, the static superheat on the valve MUST be adjusted. The URS-1 Unit performs best at a static superheat of 3 to 7 degrees. In order to adjust the static superheat, locate the expansion valve adjustment stem (see figure 10). It should be clearly visible through the fan plenum. Open the adjustment port with a 3/16 hexagonal key or wrench. Locate the adjustment stem under the adjustment port cap. 4

Fan Plenum TXV Adjustment PORT 3/16 HEX Key Figure 10 TO ADJUST: Rotate the adjustment screw COUNTER-CLOCKWISE until it stops. Rotate the adjustment screw CLOCKWISE for 4 and 1/2 turns. (4½ only!) The superheat should now be adjusted to approximately 7 degrees. Replace the sealing cap and install the evaporator s front cover to seal the enclosure. (Figure 3) STEP 4: System Evacuation. Utilizing the suction line port, evacuate the system to no less than 30 in Hg using a refrigeration suction pump and a dual manifold gauge system. (See Figure 11) 5

Liquid Line Suction Line In-Line Filter Suction Port High Side Filter port STEP 5: System Re-Charging Figure 11 Using a refrigerant scale, slowly charge 9 ounces or R-22 refrigerant into the system. Preferably charge the system through the low side (suction side) without flooding the compressor. If the system will not accept the 9 ounces readily, plug the URS-1 unit into an electrical outlet, turn the refrigeration system on and continue charging until 9 ounces have been filled. DO NOT overcharge the system, failure to follow the correct amount of refrigerant will lead to a unit that will not perform correctly under severe hot weather. STEP 6: Controller Re-Programming The Refrigeration Controller unit that manages all the refrigerator operations and performance is a Sporlan Electronic Controller. The refrigeration control has been preset at the factory for normal, everyday operation under normal conditions. In order for the unit to operate better in severe and hot weather conditions, it has been determined that the following re-programming is necessary: (Refer to figures 12 and figure 13) 6

See Note UP KEY (Compressor ON Status Light) see note SET POINT KEY (Alarm indicator) see note DOWN KEY (Defrost Status Light) Figure 12 Figure 13 Begin by changing the temperature set point of operation by doing the following: 1. Press the SET button for 1 second to display the set point temperature. 2. Hold the SET key until the set point starts flashing. 3. Use the key to increase the temperature or key decrease the temperature until the set point of 21 F has been reached. 4. Press the SET button once more to confirm the value. NOTE: Depending on the controller revision model, it will either have indicator lights on the buttons themselves (see figure 13) or (newer models) will have indicator symbols on the left side of the display. If so, these 3 status symbols will indicate the following: Shows when the compressor is ON Shows that there is an ALARM Shows the unit is on DEFROST OPERATIONAL PARAMETERS Introduction: There are two sets of parameters that can be access on this controller. Some require a password, other do not. 1. Press the SET button for 1 second to display the set point temperature (21 F) default. 2. Hold the SET key for at least 5 seconds once more (the set point starts flashing and after 5 seconds the letters PS will appear on the screen). PS = PASSWORD 3. Release the SET key. 4. At this point, press the SET once more and use the or keys to reach the number 22 on the screen (this is your password). 5. Press the SET key once more to return the display to PS. 6. Use the or keys to cycle through the different programming parameters. 7. ALWAYS Press the SET button for at lest 5 seconds to exit the programming mode. Review: MENU ITEM: (example: PS) PROGRAM: PRESS SET KEY CHANGE ITEM: KEYS TO CHANGE CONFIRM: PRESS SET KEY MENU ITEM: (example: PS) Continue now and program all operational variables according to the list on the following page. The URS-1 unit retrofit is now complete. 7

Sporlan OMNI-Stat Controller Settings Model: 952892-120 VAC Values to be changed from default Code: Parameter: Value Default UOM Access W/O PS With PS PASSWORD PS Password 22 22 # PROBE PARAMETERS /c Ambient probe calibration 10 0 F /2 Measurement Stability 15 4 ~ /4 Probe to display (0=ambient / 1=product) 0 0 ~ /5 Unit of Measure (0= C / 1= F) 1 0 ~ REGULATION PARAMETERS rd Regulating Differential 19 2 F r1 Minimum Allowed Temperature setting 15-50 F r2 Maximum Allowed Temperature setting 40 60 F r3 Enable Def. alarm when max def. time reached 0 0 ~ r4 Automatic variation of set point - NOT USED 3 3 ~ COMPRESSOR PARAMETERS c0 Delay compressor after power on 0 0 Minutes c1 Minimum time between 2 compressor runs 0 0 Minutes c2 Compressor shut down minimum time 5 0 Minutes c3 Compressor Operation minimum time 0 0 Minutes c4 Compressor Safety (0=OFF / 100=ON) 100 0 ~ cc Continuous Cycle Duration 4 4 Hours c6 Alarm Delay after continuous cycle 2 2 Hours DEFROST PARAMETERS Defrost type (0=heater / 1=Hot Gas / 2=timed heater / 3=timed HG) 2 3 ~ d0 di Defrost interval 6 8 Hours dt Defrost Ends Temperature 50 4 F dp Max. Defrost Duration 20 30 Minutes d4 Defrost after power on (0= NO / 1= YES) 0 0 ~ d5 Defrost delay after power on 0 0 Minutes d6 Block Display during Defrost (0= NO / 1= YES) 1 1 ~ dd Dripping time after defrost 2 2 Minutes d8 Alarm delay after defrost 1 1 Hours Defrost priority over minimum compressor time (0= NO / 1= YES) 0 0 ~ d9 d/ Defrost probe - display temperature ~ ~ ~ dc Time base for di and dp (0= hrs / 1= minutes) 0 0 ~ ALARM PARAMETERS A0 Alarm and Fans Differential Temp 0 0 F AL Low temperature alarm (0= OFF) 0 0 F AH Hight temperature alarm (0=OFF) 0 0 F Ad Alarm Temperature delay 0 0 Minutes A7 Alarm imput detection delay 0 0 Minutes OTHER PARAMETERS H0 Serial Address (communications) 1 1 ~ Alarm Relay Operation (0=Alarm w/relay ON - 1=Alarm w/ relay OFF) 1 1 ~ H1 H2 0= Disable Buttons / 1=Enable Buttons 1 1 ~ H5 Identification for Programming 0 0 ~ T External Programming ~ ~ ~ 8