Added cooling capacity of 140 W. (air-cooled).

Similar documents
Can precisely control the temperature of a heat source or process fluid.

Added cooling capacity of 140 W. (air-cooled).

Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature

HEB Series. Peltier-Type Thermoelectric Bath

Mountable in a 19-inch rack

HEB Series. Thermoelectric Bath

Thermoelectric Bath. Series HEB

Thermoelectric Bath. Series HEB

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly.

10 c to 60 c 300 W, 500 W, 750 W. direct temperature control for chemical liquids!! HED Series. Industry-leading withstand pressure 0.35 MPa!!

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Peltier-Type Temperature Control System for Chemicals. Fluororesin heat exchanger allows direct temperature control for chemicals!!

SEMI Standard S2-0703, S8-1103, F

Refrigerated Thermo-chiller

Water-cooled Thermo-chiller

Type of Fluorinated fluids / Ethylene glycol aqueous solution / circulating fluid: Clear water, Deionized water Temperature range setting:

Water-cooled Thermo-chiller

Circulating Fluid Temperature Controller Refrigerated Thermo-cooler

Water-cooled Thermo-chiller

Chiller Lineup. Thermo-chiller. A chiller is used to control the temperature of circulating fluid and supply it to the heat source.

Water-cooled Thermo-chiller

A Chiller is equipment to control temperature of customers heating sources. Application Examples

Refrigerated Thermo-cooler

0.1 c. R134a (HFC) Thermo-chiller. ( A device for circulating a fluid ) Series HRZ. with a constant temperature

Large energy saving by triple control!

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions

Large energy saving by triple control!

Operation Manual. Thermo Electric Bath HEBC002-WA10 HEBC002-WB10

using heat exhausted by refrigerating circuit.

RoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W

Refrigeration air dryer

Large energy saving by triple control!

Recirculating Coolers

Technical Data C O N T E N T S

Lightweight and Compact

Refrigerated Air Dryer

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

% by up ctoond re-heater and

Customized Industrial Products

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Refrigerated Air Dryer

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

Refrigerated Air Dryer

Pressure Switches Precautions 1 Be sure to read this before handling.

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

Advantages / Characteristics

Chapter 5 Inspection and maintenance

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Operation Manual Installation Operation

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Refrigerated Air Dryer

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Improved productivity Two-stage detection

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Desicators & Dry Cabinets

Document No. IZ*-OMP0064 C. P r o d u c t Ionizer. Model/Series. IZS4 Series

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

Screw Water Cooled Chiller SCW210

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Daily maintenance and checks

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Operation Manual Installation Operation

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Supporting manufacturing shop floor with advanced liquid temperature control technologies

MD-MINI Dry Bath. Instruction Manual

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from

Components for solar heating systems

User s Information Manual

Water Circulator (Chiller) & Cold Trap

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

M7100 Pressure Transducer

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Chiller System RFCS. Application Field. Symbol. General. Product Features

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Operation Manual Air-refrigerated Thermo cooler HRG010-A HRG015-A SMC Corporation Save This Manual Carefully for Use at Any Time

Operation Manual. (Version 1.5.1)

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

13-1. Temperature Regulator

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Series Temperature Controller Instruction Sheet

Installation/Instruction Manual

Transcription:

Peltier-Type Chiller/Thermo-con Series Air-cooled Water-cooled Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using the Peltier device. Generates little vibration, and is refrigerant-free and environmentally friendly. Can control the temperature of the heat source by using the external temperature sensor (sold separately). (Automatically adjusts to the effects of ambient temperature.) Temperature range setting: 1 C to 6 C Temperature stability: ±.1 C to.3 C Air-cooled -A Series Fan Thermo-con 14W: W184 x H262 x D321 23W: W21 x H393 x D436 32W: W184 x H262 x D321 6W: W24 x H39 x D455 6W: W24 x H39 x D455 12W: W3 x H448 x D523 Air-cooled: Can be used in the environments with no cooling equipment. Cooling capacity: 23 W, 6 W Added cooling capacity of 14 W and 32 W (watercooled), and 6 W (air-cooled). controlled to a constant temperature Peltier device (Thermo-module) Water-cooled Circulating fluid Tap water Heat source Air-cooled RoHS Water-cooled X-ray diagnostic instrument Blood preservation equipment Electron microscope etc. 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH Water-cooled Cooling tower, etc. Cooling tower Facility water Cools or heats the circulating fluid -W Series Thermo-con Exchanges heat with the circulating fluid to maintain a constant temperature. Water-cooled: Can be used in the environments with facility water equipment. Cooling capacity: 14 W, 32 W, 6 W, 12 W Circulating fluid Tap water, Fluorinated fluid 2% ethylene glycol Heat source Note) Except 6, 12 RoHS Temperature control of chamber electrode Electron microscope Laser machining etc. 33

Compliant with safety standard for medical equipment IEC 661-1 (Air-cooled/2-A series) Power supply: Applicable to 1 V to 24 V (Air-cooled/-A series, Water-cooled/1-W, 3-W) Suitable to fluorinated fluids (Fluorinert TM FC-3283, GALDEN HT135) (Water-cooled/6-W, 12-W) Compatible with ethylene glycol 2% (Water-cooled/1-W, 3-W) Learning Control Function (Temp. control by external temperature sensor) This function adjusts the fluid temperature to the set value with an automatic offset setting. Set the external temperature sensor at the circulating fluid inlet located just in front of the heat source, which allows the Thermo-con to sample the fluid temperature. This function is effective when automatically adjusting for heat exhaust from piping, etc. If the external temperature sensor is installed directly on the heat source, the learning control function may not work property due to large heat volume or large temperature difference. Be sure to install the sensor at the circulating fluid inlet. Principle of Peltier Device (Thermo-module) A Peltier device (thermo-module) is a plate type element, inside which P-type semiconductors and N-type semiconductors are located alternately. If direct current is supplied to the Peltier device (thermo-module), heat is transferred inside the device, and one face generates heat and increases temperature while the other face absorbs heat and decreases temperature. Therefore, changing the direction of the current supplied to the Peltier device (thermo-module) can achieve heating and cooling operation. This method has a fast response and can shift quickly between heating and cooling, so temperature can be controlled very precisely. Cooling Heat suction (cooling) Heating Heat generation (heating) Air-cooled -A Series Electron flow N P Electron hole flow Electron flow N P Electron hole flow Fan Fan Current Heat generation (heating) DC power supply Cooling Heat suction (cooling) Current Heat suction (cooling) DC power supply Heating Heat generation (heating) Water-cooled -W Series Electron flow N P Electron Electron N P Electron hole flow flow hole flow Facility water Current Heat generation (heating) DC power supply Facility water Current Heat suction (cooling) DC power supply 34

Construction and Principles Air-cooled -A Series Figure 1 Water-cooled Power supply & Controller Peltier device (Thermo-module) Figure 1 Fan Controller Heat exchanger ( side) Heat exchanger (Cooling side) -W Series Power supply & Controller Controller T Temperature sensor Pump Fan Switching power supply Fan Power switch Tank Switching power supply Noise filter PE Flow switch (option) Power switch OUT IN supply port (Tank lid) Level switch PE drain port Noise filter 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH Peltier device (Thermo-module) Heat exchanger ( side) Heat exchanger (Cooling side) T Temperature sensor Level switch 1 Flow switch 3 OUT IN supply port (Tank lid) Facility water IN Pump Circulating 2 tank Facility water OUT Circulating fluid drain port Supply tank *1 Optional setting for the 1 and 3 *2 Not built in the 1 and 3 *3 Optional setting for the 1 and 3 only Figure 2 Thermo-con Example of circulating fluid piping Target of temperature control The thermo-con is constructed as shown in Figure 1. It interposes a Peltier device (thermo-module) between the heat exchangers for the circulating fluid and facility water and controls the pulse width of supply direct current to achieve the target outlet temperature of circulating fluid precisely. The circulating fluid returns to the tank, and is transferred by the pump which is built in the thermo-con, and goes through the heat exchangers and internal sensors and out from the circulating fluid outlet. Figure 2 shows an example of circulating fluid piping. The circulating fluid is transferred at a constant temperature by the pump. 35

When to Use Air-cooled and Water-cooled Thermo-con Both air-cooled and water-cooled thermo-cons are available. Select a proper thermo-con by referring to the following. Air-cooled No facility water equipment Frequent piping changes Water-cooled Need to avoid effects of ambient temperature. Want to reduce the installation space. Can install the unit easily without facility water equipment. Can reduce the piping installation labor since facility water piping is not required. Since the unit is water-cooled, the ambient temperature will have little effect. Can reduce the space since the unit is compact. Application Examples Air-cooled Semiconductor Example: Temperature control of a chamber electrode Upper electrode Water-cooled Medical Air-cooled Example: Blood preservation Wafer H H L L Lower electrode Etching equipment Spatter equipment Cleaning equipment Coating equipment Dicing equipment Tester, etc. X-ray diagnostic instrument MRI Blood preservation equipment Machine tool Air-cooled Water-cooled Example: Laser machining Analysis Air-cooled Water-cooled Example: Electronic microscope Electronic microscope CRT H H L L Wire cutting Grinder Spot welding Plasma welding Laser machining, etc. Temperature-controlling the laser generating tube enables the laser wavelength to be optimised, improving the accuracy of the machined cross sectional area. Electron microscope X-ray analytical instrument Gas chromatography Sugar level analytical instrument, etc. Prevents the distortion caused by the heat generated by the electronic gun in an electronic microscope. Bonding of DVD including next generation Air-cooled Water-cooled Cooling of semiconductor laser Air-cooled Water-cooled Temperature control of die-cast mold Air-cooled Water-cooled 36

CONTENTS Series Model Selection... Page 38 Thermo-con Air-cooled -A Series How to Order/Specifications... Page 31 Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet)... Page 311 Parts Description... Page 312 Dimensions... Page 313 Connectors... Page 315 Alarm/Maintenance... Page 316 Options... Page 317 Thermo-con Water-cooled -W Series How to Order/Specifications... Page 322 Cooling Capacity/Heating Capacity/Pump Capacity (Thermo-con Outlet)/Pressure Loss in Facility Water Circuit... Page 324 Parts Description... Page 327 Dimensions... Page 328 Connectors... Page 331 Alarm/Maintenance... Page 332 Options... Page 333 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH Specific Product Precautions... Page 318 Specific Product Precautions... Page 334 37

Series Model Selection Guide to Model Selection 1. What radiation method will be used? Without a cooling tower Air-cooled -A series With a cooling tower Water-cooled -W series When to Use Air-cooled and Water-cooled Thermo-con <Air-cooled> No facility water equipment Can install the unit easily without facility water equipment. Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. <Water-cooled> Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. Want to reduce installation space. Can reduce the space since the unit is compact. 2. How much is the temperature in degrees centigrade for the circulating fluid? Temperature range which can be set with the thermo-con: 1 to 6 C If a lower temperature (down to 2 C) or higher temperature (up to 9 C) than this range is necessary, select the thermo-chiller HRZ series. 3. What kind of the circulating fluids will be used? s that can be used in the thermo-con Model 1-W, 3-W 6-W, 12-W 2-A, 6-A Tap water Fluorinert TM FC-3238 GALDEN HT135 Option 2% ethylene glycol : Usable : Unusable 4. How much cooling capacity required? Allows a safety factor of 2% over the capacity that is actually required, taking into account the changes in the operating conditions. If a larger capacity than this thermo-con is necessary, select the thermo-cooler HRG series or thermo-chiller HRZ series. Example 1 When the heat generation amount in the customer s machine is known. Heat generation amount: 4 W Cooling capacity = Considering a safety factor of 2%, 4 x 1.2 = 48 W 38

Model Selection Series Guide to Model Selection Example 2 When the heat generation amount in the customer s machine is not known. Obtain the temperature difference between inlet and outlet by circulating the fluid inside the customer s machine. Heat generation amount Q : Unknown temperature difference T (= T2 T1) :.8 C (.8 K) outlet temperature T1 : 25 C (298.15 K) return temperature T2 : 25.8 C (298.95 K) flow rate L : 3 L/min : Water Density γ: 1 x 1 3 kg/m 3 Thermo-con Specific heat C: 4.2 x 1 3 J/(kg K) Q = T x L x γ x C T2: Return temperature 6 x 1 Customer s.8 x 3 x 1 x 1 3 x 4.2 x 1 3 L machine = T = T2 T1 6 x 1 H = 167 W Cooling capacity = Considering a safety factor of 2%, 167 W x 1.2 = 2 W Example 3 L T1: Outlet temperature Cooled substance total volume V : 2 L Cooling time h : 15 min Cooling temperature difference T : Temperature difference: 1 C (1 K). Cool from 3 C (33 K) to 2 C (293 K). : Tap water Density γ: 1 x 1 3 kg/m 3 Specific heat C: 4.2 x 1 3 J/(kg K) Water bath Refer to the information shown below for the typical physical property values by circulating fluid. Q = T x V x γ x C h x 6 x 1 When cooling the object below a certain temperature in certain period of time. = 1 x 2 x 1 x 13 x 4.2 x 1 3 15 x 6 x 1 = 933 W Cooling capacity = Considering a safety factor of 2%, 933 W x 1.2 = 112 W H L 2 C After 15 min, cool 3 C down to 2 C. V 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH Precautions on Model Selection The flow rate of the circulating fluid depends on the pressure loss of the customer s machine and the length, diameter and resistance created by bends in the circulating fluid piping, etc. Check if the required flow rate of circulating fluid can be obtained before selecting. Circulating Fluid Typical Physical Property Values Fluorinated Fluids Physical property value Temperature 1 C 2 C 5 C 8 C Density γ [kg/m 3 ] 1.87 x 1 3 1.8 x 1 3 1.74 x 1 3 1.67 x 1 3 Specific heat C [J/(kg K)].87 x 1 3.96 x 1 3 1.5 x 1 3 1.14 x 1 3 Water Density γ: 1 x 1 3 [kg/m 3 ] Specific heat C: 4.2 x 1 3 [J/(kg K)] 39

Peltier-Type Chiller Thermo-con (Air-cooled) -A Series RoHS How to Order 2 A 5 B Cooling capacity 2 23 W 6 6 W Radiating method A Air-cooled Power supply 5 1 to 24 VAC Option Nil None F With flow switch N NPT thread The option should be specified when ordering. Communication A RS-485 B RS-232C Select B when communication is not used. Specifications (For details, please consult our Product Specifications information.) Model 2-A5A 2-A5B 6-A5A 6-A5B Cooling method Radiating method Control method Ambient temperature/humidity Operating temperature range Thermoelectric device (Thermo-module) Forced air cooling Cooling/Heating automatic shift PID control 1 to 35 C, 35 to 8%RH (no condensation) Tap water, 2% ethylene glycol aqueous solution 1. to 6. C (no condensation) Cooling capacity Heating capacity 23 W Note 1) 6 W Note 1) 6 W Note 2) 9 W Note 2) Temperature stability Note 3) Pump capacity Tank capacity ±.1 to ±.3 C Refer to performance chart. Approx. 1.2 L Port size IN/OUT Rc1/4 Rc3/8 Drain Wetted parts material Power supply Overcurrent protector Rc1/4 (with plug) Stainless steel 33, Stainless steel 34, EPDM, Ceramics, PPS glass 3%, Carbon, PE, Polyurethane Single-phase 1 to 24 VAC ±1%, 5/6 Hz 15 A Current consumption 8 A (1 VAC) to 3 A (24 VAC) 1 A (1 VAC) to 4 A (24 VAC) Alarm Refer to alarm function. Communications RS-485 RS-232C RS-485 RS-232C Weight Approx. 17.5 kg (including foot for fixing) Approx. 27.5 kg (including foot for fixing) Accessories Power cable, Foot for fixing Safety standards CE marking, UL (NRTL) standards, Safety standard for medical equipment (IEC 661-1) CE marking, UL (NRTL) standards system Electrical system Note 1) Conditions: Set temperature 25 C, Ambient temperature 25 C, Circulating flow rate 3 L/min Note 2) Conditions: Set temperature 25 C, Ambient temperature 2 C, Circulating flow rate 8 L/min Note 3) The indicated values are with a stable load without turbulence in the operating conditions. It may be out of this range in some other operating conditions. 31

Peltier-Type Chiller Thermo-con (Air-cooled) -A Series Cooling Capacity 2 8 : Tap water The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. 6 14 : Tap water Cooling capacity (W) Cooling capacity (W) 7 6 5 4 3 2 1 1 1 2 3 4 5 6 7 temperature ( C) Heating Capacity 2 Ambient temperature: 15 C 9 8 7 6 5 Ambient temperature: 15 C 4 3 2 1 Ambient temperature: 25 C Ambient temperature: 35 C : Tap water Ambient temperature: 25 C Ambient temperature: 35 C Cooling capacity (W) Cooling capacity (W) 12 1 8 6 4 2 6 2 18 16 14 12 1 8 6 4 2 Ambient temperature: 15 C 1 2 3 4 5 6 7 temperature ( C) Ambient temperature: 15 C Ambient temperature: 2 C Ambient temperature: 3 C : Tap water Ambient temperature: 2 C Ambient temperature: 3 C 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH 1 2 3 4 5 6 7 temperature ( C) 1 2 3 4 5 6 7 temperature ( C) Pump Capacity (Thermo-con Outlet) The pressure on the y-axis shows the discharge pressure of circulating fluid in the thermo-con. 2 : Tap water 6.1.12 : Tap water Discharge pressure (MPa).8.6.4.2 Discharge pressure (MPa).1.8.6.4.2. 1 2 3 4. 1 2 3 4 5 6 7 8 9 1 flow rate (L/min) flow rate (L/min) 311

-A Series Parts Description 2 Power connector Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Display/Operation panel Power switch Alarm connector External temperature sensor connector Circulating fluid outlet Filter Tank lid with gasket level gauge Circulating fluid inlet Drain (circulating fluid drain port) 6 Power connector Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Display/Operation panel Power switch Alarm connector External temperature sensor connector Circulating fluid outlet Filter Tank lid with gasket level gauge Circulating fluid inlet Drain (circulating fluid drain port) 312

Peltier-Type Chiller Thermo-con (Air-cooled) -A Series Dimensions 2 436 414 46 3 Power cable (Accessory) 4 x 5 Warning/Caution label Handle 145 39 Model no. label R4 57 142 Display/Operation panel 6 21 24 27 Power switch Tank lid with gasket 49 Air Alarm output connector Communication connector Power connector Air Handle External temperature sensor connector 298 145 11 51 1/15 H H E HRZ HRZD HRW 393 385 347 Circulating fluid outlet Rc1/4 97 3 157 281 Air Air 27 347 3 27 level gauge 21 358 4 x Plastic foot 152 29 R HEB Foot (Accessory) 12 Filter cover Filter 321 364 drain port (with plug) Rc1/4 inlet Rc1/4 HED HEA IDH Option (Fitting part) NPT fitting specification (-N, -FN) outlet NPT1/4 inlet NPT1/4 drain port (with plug) NPT1/4 Power Cable (Accessory) Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 1 to 24 VAC Black 1 to 24 VAC Green/Yellow PE 2 313

-A Series Dimensions 6 455 433 46 28 R4 Warning/Caution label Display/Operation panel Power switch Handle Power connector Power cable (Accessory) 39 382 361 16 Model no. label Handle 6 48 Tank lid with gasket Circulating fluid outlet Rc3/8 Air Circulating fluid inlet Rc3/8 278 Air Communication connector Alarm output connector External temperature sensor connector Air Air 219 16 17 14 171 1 Foot (Accessory) Filter cover 346 384 Filter drain port (with plug) Rc1/4 level gauge 32 36 361 176 72 157 24 27 3 4 x 5 37 33 286 266 246 361 4 x Plastic foot Option (Fitting part) NPT fitting specification (-N, -FN) outlet NPT3/8 inlet NPT3/8 drain port (with plug) NPT1/4 Power Cable (Accessory) Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 1 to 24 VAC Black 1 to 24 VAC Green/Yellow PE 2 314

Peltier-Type Chiller Thermo-con (Air-cooled) -A Series Connectors 1. Power connector (AC) IEC 632 C14 or equivalent 1 2 Pin No. 1 2 3 Contents 1 to 24 VAC 1 to 24 VAC PE 2. Communication connector (RS-232C or RS-485) D-sub 9 pin (socket) Holding screw: M2.6 Pin No. 1 2 3 4 5 6-9 RS-232C RD SD SG Signal contents RS-485 BUS+ BUS SG 3 3 2 5 4 1 9 8 7 6 1/15 H H E HRZ HRZD 3. External sensor connector (EXT.SENSOR) D-sub 15 pin (socket) Holding screw: M2.6 Pin No. Signal contents 1-2 3 Terminal A of resistance temperature detector 4 Terminal B of resistance temperature detector 5 Terminal B of resistance temperature detector 6-14 15 FG 8 7 6 5 4 3 2 3 4 5 1 HRW R HEB HED HEA IDH 15 14 13 12 11 1 9 4. Alarm output connector (ALARM) D-sub 9 pin (pin) Holding screw: M2.6 Pin No. 1 2 3 4-5 6 7 8 9 Signal contents Contact a for output cut-off alarm (open when alarm occurs) Common for output cut-off alarm Contact b for output cut-off alarm (closed when alarm occurs) Contact a for upper/lower temp. limit alarm (open when alarm occurs) Common for upper/lower temp. limit alarm Contact b for upper/lower temp. limit alarm (closed when alarm occurs) 6 1 2 7 3 4 5 8 9 315

-A Series Alarm This unit is equipped as standard with a function allowing 15 kinds of alarms to display on the LCD and can be read out by serial communication. Also, it can generate relay output for upper/lower temperature limit alarm and output cut-off alarm. Alarm Alarm code WRN ERR ERR1 ERR3 ERR4 ERR11 ERR12 Alarm description Upper/Lower temp. limit alarm CPU hung-up CPU check error Back-up data error EEPROM writing error DC power supply failure Internal temp. sensor high temp. error Operation status Continue Stop Stop Stop Stop Stop Stop Main reason The temperature has exceeded the upper or lower limit of the target temperature. The CPU has crashed due to noise, etc. The contents of the CPU cannot be read out correctly when the power supply is turned on. The contents of the back-up data cannot be read out correctly when the power supply is turned on. The data cannot be written to EEPROM. The DC power supply has failed (due to fan stop or abnormal high temperature) or the thermo-module has been short-circuited. The internal temperature sensor has exceeded the upper limit of cut-off temperature. Internal temp. sensor ERR13 low temp. error Stop The internal temperature sensor has exceeded the lower limit of cut-off temperature. ERR14 Thermostat alarm Stop The thermostat has been activated due to filter clog or fan/pump failure, etc. ERR15 Abnormal output alarm Continue The temperature cannot be changed even at 1% output due to overload or disconnection of the thermo-module. ERR16 Low flow rate alarm (option) Stop The flow rate of the circulating fluid has dropped. ERR17 Internal temp. sensor disconnection alarm Stop The internal temperature sensor has been disconnected or short-circuited. ERR18 External temp. sensor The external temperature sensor has been disconnected or short-circuited. (Only detected Continue disconnection alarm when in learning control or external tune control) ERR19 ERR2 Abnormal auto tuning alarm Low fluid level alarm Stop Stop Auto tuning has not been completed within 2 minutes. The amount of circulating fluid in the tank has dropped. Maintenance Maintenance of this unit is performed only in the form of return to and repair at SMC s site. As a rule, SMC will not conduct on-site maintenance. Separately, the following parts have a limited life and need to be replaced before the life ends. Parts Life Expectation Description Pump Fan DC power supply Expected life 3 to 5 years 5 to 1 years 5 to 1 years Possible failure The bearing is worn so the pump fails to transfer the circulating fluid, which results in temperature control failure. The bearing uses up lubrication and makes the fan unable to supply enough air, which deteriorates the cooling and heating capacity. The capacity of the electrolytic condenser decreases, and causes abnormal voltage which results in DC power supply failure and stops the thermo-con. Display panel 5, hours (approx. 5 years) The display turns off when the backlight of the LCD reaches the end of its life. 316

-A Series Options Note) Options have to be selected when ordering the thermo-con. It is not possible to add them after purchasing the unit. F Option symbol With Flow Switch F With flow switch This is an ON/OFF switch detecting low levels of the circulating fluid. When the fluid volume is 1 L/min. or less, ERR16 is displayed and the thermo-con stops. This switch is installed between the circulating fluid inlet and the tank, and built into the thermo-con. Refer to page 35. N Option symbol NPT Thread N NPT thread The connection parts of circulating fluid piping, facility water piping and circulating fluid drain port are NPT thread type. Type Type Aircooled Aircooled Applicable model 2-A5-F 6-A5-F Applicable model 2-A5-N 6-A5-N 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH 317

-A Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to back page 5 for Safety Instructions and pages 13 to 16 for Temperature Control Equipment Precautions. Warning System Design 1. This catalog shows the specifications of the Thermo-con. 1. Check detailed specifications in the separate Product Specifications, and evaluate the compatibility of the thermo-con with customer s system. 2. Although the protection circuit as a single unit is installed, the customer is requested to carry out the safety design for the whole system. Warning Handling 1. Thoroughly read the Operation Manual. Read the Operation Manual completely before operation, and keep this manual available whenever necessary. 2. If the set temperature is repeatedly changed by 1 C or more, the thermo-con may fail in short periods of time. Caution Intake 1 mm or more Radiation Air 1. The inlet for radiation air must not be exposed to particles and dust as far as possible. 2. Do not let the inlet and outlet for radiation air get closed. <2> If radiation is prevented, the set temperature may not be achieved depending on the value of the set temperature and the load. Keep a space of 1 mm for opened rear side or 2 mm for closed rear side respectively. Discharge 1 mm or more The rear side is opened. Operating Environment/Storage Environment Warning 1. Keep within the specified ambient temperature and humidity range. Also, if the set temperature is too low, condensation may form on the inside of the thermo-con or the surface of piping even within the specified ambient temperature range. Dew condensation can cause failure, and so must be avoided by considering operating conditions. 2. The thermo-con is not designed for clean room usage. It generates dust from the pump inside the unit and the cooling fan. 3. Low molecular siloxane can damage the contact of the relay. Use the thermo-con in a place free from low molecular siloxane. <6> Intake 2 mm or more Intake 5 mm or more Discharge 2 mm or more Discharge 5 mm or more The rear side is closed. The rear side is opened. Intake Discharge The rear side is closed. 5 mm or more 5 mm or more Note) The space must be 5 mm or more. Be sure that the ambient temperature is within the specification range. 318

-A Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to back page 5 for Safety Instructions and pages 13 to 16 for Temperature Control Equipment Precautions. Caution Radiation Air Caution 3. If more than one thermo-con is used, consider their arrangement so that the downstream sides of the thermo-cons suck radiation air from the upstream sides. Otherwise, the performance at the downstream sides may deteriorate. Also, the set temperature may not be achieved depending on the value of the set temperature and the load. In such a case, take countermeasures such as changing the direction of the thermo-cons to prevent the deterioration of performance. 4. If dust adheres to the filter, remove dust with a vacuum cleaner or a dry cloth. 5. Do not operate without the filter. Otherwise, dust may accumulate on the heat sink and electrical components, causing abnormal heating. Circulating Fluid 1. Use tap water or fluid which will not damage the wetted material. (Stainless steel 33, Stainless steel 34, EPDM, Polypropylene, PE, PPE, Ceramics, Polyurethane) 2. Deionized water (with an electrical conductivity of approx. 1 µs/cm) can be used, but may lose its electrical conductivity. Also, if a facility supplying deionized water is used, the thermocon may be damaged by static electricity. 3. If deionized water is used, bacteria and algae may grow in short periods of time. If the thermo-con is operated with bacteria and algae, its cooling capacity or the capacity of the pump may deteriorate. Exchange all deionized water regularly depending on the conditions (once a month as a guide). 4. If using a fluid other than water, please contact SMC beforehand. 5. The maximum operating pressure of circulating fluid circuit is.1 MPa. If this pressure is exceeded, leakage from the tank in the thermo-con can result. 6. Select a pipe with a length and diameter which allow a flow rate of 1 L/min or more (2) or 3 L/min or more (6) for the circulating fluid. If the flow rate is less than these values, the thermo-con cannot provide precise control, but also can fail because of the repeated cooling and heating operation. 7. A magnet driven pump is used as a circulating pump. A fluid which contains metal powders such as iron powder cannot be used. 8. The thermo-con must not be operated without circulating fluid. The pump can break due to idling. Caution Circulating Fluid 9. If the tank lid is opened after the supply of circulating fluid, the circulating fluid may spill out depending on the condition of external piping. 1. If an external tank is used, the circulating fluid may spill out from the internal tank lid depending on where the external tank is installed. Check that the internal tank has no leakage if using an external tank. 11. If there is a point where fluid is released to atmosphere externally (tank or piping), minimize the piping resistance at the circulating fluid return side. If the piping resistance is too large, the piping may be crushed, or the built-in circulator tank may be deformed or cracked because the pressure in the piping for return will become negative. The built-in circulator tank is made of resin (PE). Therefore, the tank may be crushed if the pressure is negative. Special attention must be paid if the flow rate of the circulating fluid is high. To avoid getting negative pressure less than.2 MPa, the piping for return should be as thick and short as possible to minimize the piping resistance. It is also effective to restrict the flow rate of circulating fluid or remove the gasket of internal tank for the release to atmosphere. 12. Fluorinated fluid is outside of the specifications. If it is used in the thermo-con, static electricity will be generated by the flow of fluid. This static electricity may be discharged to the board of the thermo-con, causing damage or operation failure and loss of data of such as set temperature. Also, as the specific gravity of the fluorinated fluid is 1.5 to 1.8 times of water, the pump will be overloaded, which also causes fluorinated fluid to be outside the specifications. Therefore, if fluorinated fluid is used, please contact SMC and we will introduce a suitable special product (water-cooled type). 13. Avoid operation with cavitation or bubbles due to low fluid level in the tank. This may shorten the pump life. 14. If tap water is used, it should satisfy the quality standards shown below. Tap Water (as Circulating Water) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-2-1994 Cooling water system Circulating type Supply water Influence Item Unit Standard value Scale Corrosion generation ph (at 25 C) 6. to 8. Electrical conductivity (25 C) [µs/cm] 1 to 3 Chloride ion (Cl ) Standard Sulfuric acid ion (SO4 2 ) 5 or less 5 or less item Acid consumption amount (at ph4.8) Total hardness Calcium hardness (CaCO3) Ionic state silica (SiO2) 5 or less 7 or less 5 or less 3 or less Iron (Fe) Copper (Cu) Reference Sulfide ion (S2 ).3 or less.1 or less Should not be detected. item Ammonium ion (NH4 + ) Residual chlorine (Cl) Free carbon (CO2).1 or less.3 or less 4. or less In the case of [MΩ cm], it will be.3 to.1. : Factors that have an effect on corrosion or scale generation. Even if the water quality standards are met, complete prevention of corrosion is not guaranteed. 319 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH

-A Series Specific Product Precautions 3 Be sure to read this before handling the products. Refer to back page 5 for Safety Instructions and pages 13 to 16 for Temperature Control Equipment Precautions. Caution 1. The set value can be written to EEPROM, but only up to approx. 1 million times. In particular, pay attention to how many of times the writing is performed using the communication function. Warning Communication Maintenance 1. Prevention of electric shock and fire Do not operate the switch with wet hands. Also, do not operate the thermo-con with water left on it. 2. Action in the case of error If any error such as abnormal sounds, smoke, or bad smell occurs, cut off the power at once, and stop supplying and conveying fluid. Please contact SMC or a sales distributor to repair the thermo-con. 3. Regular inspection Check the following items at least once a month. The inspection must be done by an operator who has sufficient knowledge and experience. a) Check of displayed contents. b) Check of temperature, vibration and abnormal sounds in the body of the thermo-con. c) Check of the voltage and current of the power supply system. d) Check for leakage and contamination of the circulating fluid and intrusion of foreign objects to it, and subsequent replacement of the fluid. e) Check for flow condition, temperature and filter of radiation air. 32

Peltier-Type Chiller Thermo-con (Water-cooled) -W Series Note) Except 6, 12 RoHS 14 W, 32 W How to Order 3 W 5 B Cooling capacity 1 14 W 3 32 W Radiating method W Water-cooled Power supply 5 1 to 24 VAC Option Nil None F With flow switch N NPT thread L With level switch The option should be specified when ordering. Communication A RS-485 B RS-232C Select B when communication is not used. Specifications (For details, please consult our Product Specifications information.) Model 1-W5A 1-W5B 3-W5A 3-W5B Cooling method Radiating method Control method Ambient temperature/humidity Operating temp. range Thermoelectric device (Thermo-module) Water-cooled Cooling/Heating automatic shift PID control 1 to 35 C, 35 to 8%RH (no condensation) Tap water, 2% ethylene glycol 1. to 6. C (no condensation) Cooling capacity Heating capacity 14 W Note 1) 4 W Note 1) 32 W Note 1) 77 W Note 1) Temperature stability Note 2) Pump capacity Tank capacity ±.1 to.3 C Refer to performance chart. Approx. 1.2 L IN/OUT: Rc3/8 Port size Wetted parts material Temperature range Pressure range Required flow rate Note 3) Port size Wetted parts material Power supply Overcurrent protector Drain: Rc1/4 (with plug) PPE, PP glass 1%, Alumina ceramics, Carbon, EPDM, Stainless steel 33, Stainless steel 34, PE, PP, NBR 1 to 35 C (no condensation) Within 1 MPa 3 to 7 L/min IN/OUT: Rc3/8 Stainless steel 34 Single-phase 1 to 24 VAC ±1%, 5/6 Hz 1 A Current consumption 3.5 A (1 VAC) to 1.5 A (24 VAC) 5.5 A (1 VAC) to 2.5 A (24 VAC) Alarm Communications RS-485 Refer to alarm function. RS-232C RS-485 RS-232C Weight Approx. 12 kg Approx. 13 kg Accessories Safety standards Power cable, Foot for fixing, Splashproof cover CE marking, UL (NRTL) standards, SEMI Note 1) /Tap water conditions: set temperature 2 C, Flow rate 5 L/min., Facility water temperature 2 C, Flow rate 5 L/min., Ambient temperature 25 C Note 2) The indicated values are with a stable load without turbulence in the operating conditions. It may be out of this range in some other operating conditions. Note 3) The flow rate beyond the proper range may deteriorate performance or generate noise, causing the piping to break. system Facility water system Electrical system 322

Peltier-Type Chiller Thermo-con (Water-cooled) -W Series How to Order 6 W, 12 W 12 W 2 B Cooling capacity 6 6 W 12 12 W Radiating method W Water-cooled Power supply 2 2 to 22 VAC Specifications (For details, please consult our Product Specifications information.) Option Nil None N NPT thread The option should be specified when ordering. Communication A RS-485 B RS-232C Select B when communication is not used. FC-3283) Note 3) Model 6-W2A 6-W2B 12-W2A 12-W2B Cooling method Radiating method Control method Ambient temperature/humidity Note 1) Operating temperature range Cooling capacity Thermoelectric device (Thermo-module) Water-cooled Cooling/Heating automatic shift PID control 1 to 35 C, 35 to 8%RH (no condensation) Tap water, Fluorinated fluid (Fluorinert FC-3283, GALDEN HT135) 1. to 6. C (no condensation) 6 W (Tap water), 4 W (Fluorinert FC-3283) Note 2) 12 W (Tap water), 8 W (Fluorinert Heating capacity 9 W (Tap water), 6 W (Fluorinert FC-3283) Note 2) 22 W (Tap water), 15 W (Fluorinert Note 3) FC-3283) Temperature stability Note 4) Pump capacity ±.1 to.3 C Refer to performance chart. Tank capacity Approx. 3 L Approx. 5 L system Port size IN/OUT: Rc3/8 Drain: Rc1/4 (with plug) IN/OUT: Rc3/4 Drain: Rc1/4 (with plug) 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH Wetted parts material Stainless steel 33, Stainless steel 34, EPDM, Ceramics, PPS glass 3%, Carbon, PE, Polyurethane Stainless steel 33, Stainless steel 34, EPDM, Ceramics, PP, PE, Polyurethane, SiC, PPS Temperature range 1 to 35 C (no condensation) Pressure range Within 1 MPa Note 5) Required flow rate 8 to 15 L/min 1 to 15 L/min Port size IN/OUT: Rc3/8 IN/OUT: Rc1/2 Wetted parts material Stainless steel 33, Stainless steel 34 Power supply Single-phase 2 to 22 VAC ±1%, 5/6 Hz Overcurrent protector 1 A 15 A Current consumption 5 A 1 A Alarm Refer to alarm function. Communications RS-485 RS-232C RS-485 RS-232C Weight Approx. 25 kg (including foot for fixing) Approx. 4 kg (including foot for fixing) Accessories Power cable, Foot for fixing Safety standards CE marking Note 1) Fluorinert is a trademark of 3M and GALDEN is a registered trademark of Solvay Solexis, Inc. Regarding the fluid other than the above, please consult with SMC. Note 2) Conditions: Set temperature 25 C, Facility water temperature 2 C, Facility water flow rate 8 L/min, Ambient temperature 25 C. Note 3) Conditions: Set temperature 25 C, Facility water temperature 2 C, Facility water flow rate 1 L/min, Ambient temperature 25 C. Note 4) The indicated values are with a stable load without turbulence in the operating conditions. It may be out of this range in some other operating conditions. Note 5) The flow rate beyond the proper range may deteriorate performance or generate noise, causing the piping to break. Facility water system Electrical system 323

-W Series Cooling Capacity The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. 1 : Tap water : 2% ethylene glycol 6 6 Cooling capacity (W) 5 4 3 2 1 C Facility water: 2 C 3 C 1 Facility water flow rate: 5 L/min 1 2 3 4 5 6 7 Cooling capacity (W) 5 4 3 2 C 2 1 Facility water flow rate: 5 L/min 1 2 3 4 5 6 7 temperature ( C) temperature ( C) 3 : Tap water : 2% ethylene glycol 1 1 Cooling capacity (W) 8 6 4 2 1 C Facility water: 2 C 3 C Cooling capacity (W) 8 6 4 2 2 C Facility water flow rate: 5 L/min 1 2 3 4 5 6 7 temperature ( C) Facility water flow rate: 5 L/min 1 2 3 4 5 6 7 temperature ( C) 6 : Tap water : FC-3283 15 15 Cooling capacity (W) 1 5 1 C Facility water: 2 C 35 C Cooling capacity (W) 1 5 1 C Facility water: 2 C 35 C Facility water flow rate: 8 L/min 1 2 3 4 5 6 7 temperature ( C) Facility water flow rate: 8 L/min 1 2 3 4 5 6 7 temperature ( C) 12 Cooling capacity (W) 3 25 2 15 1 5 1 C : Tap water Facility water: 2 C 35 C Facility water flow rate: 1 L/min 1 2 3 4 5 6 7 temperature ( C) Cooling capacity (W) 3 25 2 15 1 5 1 C : FC-3283 Facility water: 2 C 35 C Facility water flow rate: 1 L/min 1 2 3 4 5 6 7 temperature ( C) 324

Peltier-Type Chiller Thermo-con (Water-cooled) -W Series Heating Capacity 1 Heating capacity (W) 6 5 4 3 2 1 3 Heating capacity (W) 1 temperature ( C) : Tap water Facility water flow rate: 5 L/min 3 C 2 C 1 C 1 2 3 4 5 6 7 8 6 4 2 6 15 : Tap water Facility water flow rate: 5 L/min 3 C 2 C 1 C 1 2 3 4 5 6 7 temperature ( C) : Tap water Facility water flow rate: 8 L/min Heating capacity (W) Heating capacity (W) The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. 6 5 4 3 2 1 1 : 2% ethylene glycol Facility water flow rate: 5 L/min 1 2 3 4 5 6 7 8 6 4 2 15 temperature ( C) 2 C : 2% ethylene glycol Facility water flow rate: 5 L/min 2 C 1 2 3 4 5 6 7 temperature ( C) : FC-3283 Facility water flow rate: 8 L/min 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH Heating capacity (W) 1 5 35 C 2 C 1 C 1 2 3 4 5 6 7 temperature ( C) Heating capacity (W) 1 5 35 C 2 C 1 C 1 2 3 4 5 6 7 temperature ( C) 12 Heating capacity (W) 35 3 25 2 15 1 5 : Tap water Facility water flow rate: 1 L/min 1 C 35 C 2 C 1 2 3 4 5 6 7 temperature ( C) Heating capacity (W) 3 25 2 15 1 5 : FC-3283 Facility water flow rate: 1 L/min 1 C 35 C 2 C 1 2 3 4 5 6 7 temperature ( C) 325

-W Series Pump Capacity (Thermo-con Outlet) 1/3 Since a DC pump is used, the unit is not affected by power requirements..15 Discharge pressure (MPa).1.5 2% ethylene glycol Tap water. 2 4 6 8 1 12 flow rate (L/min) 6 Since a DC pump is used, the unit is not affected by power requirements..15 12.3 Discharge pressure (MPa).1.5 Tap water Fluorinert FC-3283 Discharge pressure (MPa).25.2.15.1.5 6Hz Fluorinert FC-3283 5Hz Tap water 6Hz. 2 4 6 8 1 12 5Hz. 5 1 15 2 25 3 flow rate (L/min) flow rate (L/min) Pressure Loss in Facility Water Circuit 1.14 3.25 Pressure loss (MPa).12.1.8.6.4.2 Pressure loss (MPa).2.15.1.5. 5 1 15 Facility water flow rate (L/min) 6.25. 5 1 15 Facility water flow rate (L/min) 12.6 Pressure loss (MPa).2.15.1.5 Pressure loss (MPa).5.4.3.2.1. 5 1 15 Facility water flow rate (L/min). 5 1 15 2 Facility water flow rate (L/min) 326

Peltier-Type Chiller Thermo-con (Water-cooled) -W Series Parts Description 1/3 Display/Operation panel Handle Power switch 6/12 Power switch Tank lid (with O-ring) inlet level gauge outlet Display/Operation panel Tank lid (with gasket) level gauge Facility water outlet Drain ( drain port) Facility water inlet External temperature sensor connector Alarm output connector Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Power connector (Connect the attached power cable.) Splashproof cover Handle Facility water outlet Facility water inlet Splashproof cover outlet inlet Drain ( drain port) Cooling fan Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Alarm output connector External temperature sensor connector Power connector (Connect the attached power cable.) 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH 327

-W Series Dimensions 1-W5 3-W5 Warning/Caution label 182 (32) 12 (55) Tank lid (with O-ring) (45.5) 1 348 Foot (Accessory) 4 x width 5 Display/ Operation panel Power switch (25) (19) 184 ø72 Power Cable (Accessory) level gauge 245 197 321 1 27 41 Circulating fluid inlet Rc3/8 221 19 28 64 84 14 OUT IN RADIATING WATER RECIRCULATING WATER 148 Facility water outlet Rc3/8 Facility water inlet Rc3/8 outlet Rc3/8 External temperature sensor connector Alarm output connector 16 EXT.SENSOR 214 143 15 ALARM IN OUT 128 Handle RS-232C 82 Communication (13) connector AC DRAIN 28 37 3 3 Model no. 368 label Power connector Splashproof cover drain port (Accessory) Rc1/4 (With plug) For NPT thread specification (-N), all fittings (including those at the circulating fluid drain port) are made of NPT. Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 1 to 24 VAC Black 1 to 24 VAC Green/Yellow PE 2 Power cable (Accessory) 328

OUT OUT IN IN Peltier-Type Chiller Thermo-con (Water-cooled) -W Series Dimensions 6-W2 H L 13 214 (13) Foot (Accessory) 4 x 7 level gauge Tank lid with gasket Power switch 455 433 458 Display/ Operation panel 482 Handle 24 246 Warning/Caution label 4 Air 382 Foot (Accessory) 39 Facility water outlet Rc3/8 Circulating 339 fluid outlet Rc3/8 Circulating fluid inlet 27 Rc3/8 146.5 Model no. label 28.5 DRAIN 168 128 RADIATING WATER Facility water inlet Rc3/8 5 RS-232C ALARM AC Fan 8 Communication connector 33 Alarm output connector 198 168 128 73 External temperature sensor connector Power connector 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH drain port Rc1/4 (with plug) 24 148 133 32 For NPT thread specification (-N), all fittings (including those at the circulating fluid drain port) are made of NPT. Power Cable Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 2 to 22 VAC Black 2 to 22 VAC Green/Yellow PE 2 Power cable (Accessory) 329

OUT IN OUT IN -W Series Dimensions 12-W2 Foot (Accessory) Power switch 523 51 55 19 3 36 (55) 4 x 7 526 Display/ Operation panel Foot (Accessory) Warning/Caution label level gauge Tank lid with gasket Handle 4 Facility water outlet Rc1/2 248 28 148 outlet Rc3/4 5 H L Air 44 448 44 326 281 Facility water inlet Rc1/2 165 28.5 DRAIN RECIRCULATING FLUID RADIATING WATER RS-232C ALARM EXT.SENSOR AC Fan 8 361 Communication connector Alarm output connector 198 168 128 67 External temperature sensor connector Power connector 55 drain port Rc1/4 (with plug) 277 Model no. label 131 4 inlet Rc3/4 For NPT fitting specification (-N), all fittings (including those at the circulating fluid drain port) are made of NPT. Power Cable Connector: DDK CE5-6A18-1SD-D-BSS or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Black Black Green/Yellow Contents 2 to 22 VAC 2 to 22 VAC PE 2 Power cable (Accessory) 33

Peltier-Type Chiller Thermo-con (Water-cooled) -W Series Connectors 6-W2/1-W5/3-W5 1. Power connector (AC) IEC 632 C14 or equivalent 6-W2 Pin No. Contents 1 2 to 22 VAC 2 2 to 22 VAC 3 PE 1-W5 3-W5 Pin No. Contents 1 1 to 24 VAC 2 1 to 24 VAC 3 PE 2. Communication connector (RS-232C or RS-485) D-sub 9 pin (socket) Holding screw: M2.6 3 1 2 1/15 H H Pin No. 1 2 3 4 5 6-9 RS-232C RD SD SG Signal contents RS-485 BUS+ BUS SG 3 2 5 4 1 9 8 7 6 E HRZ HRZD HRW 3. External sensor connector (EXT.SENSOR) D-sub 15 pin (socket) Holding screw: M2.6 Pin No. 1-2 3 4 5 6-14 15 Signal contents Terminal A of resistance temperature detector Terminal B of resistance temperature detector Terminal B of resistance temperature detector FG 5 4 6 3 8 7 2 1 15 14 13 12 11 1 9 R HEB HED HEA IDH 4. Alarm output connector (ALARM) D-sub 9 pin (pin) Holding screw: M2.6 Pin No. Signal contents 1 2 3 4-5 6 7 8 9 Contact a for output cut-off alarm (open when alarm occurs) Common for output cut-off alarm Contact b for output cut-off alarm (closed when alarm occurs) Contact a for upper/lower temp. limit alarm (open when alarm occurs) Common for upper/lower temp. limit alarm Contact b for upper/lower temp. limit alarm (closed when alarm occurs) 1 2 3 4 5 6 7 8 9 12-W2 Power connector (AC) DDK CE5-2A18-1PD-D or equivalent Pin No. A B C D Contents 2 to 22 VAC 2 to 22 VAC PE D C A B Other connectors are the same as those for the 6-W2. 331

-W Series Alarm This unit is equipped as standard with a function allowing 16 kinds of alarms to display on the LCD and can be read out by serial communication. Also, it can generate relay output for upper/lower temperature limit alarm and output cut-off alarm. Alarm code WRN ERR ERR1 ERR3 ERR4 ERR5 ERR11 ERR12 ERR13 ERR14 ERR15 ERR16 ERR17 ERR18 ERR19 ERR2 Alarm description Operation status Main reason Upper/Lower temp. limit alarm Continue The temperature has exceeded the upper or lower limit of the target temperature. CPU hung-up Stop The CPU has crashed due to noise, etc. CPU check error Stop The contents of the CPU cannot be read out correctly when the power supply is turned on. Back-up data error Stop The contents of the back-up data cannot be read out correctly when the power supply is turned on. EEPROM writing error Stop The data cannot be written to EEPROM. EEPROM input over time error 4 Stop The number of times of writing to EEPROM has exceeded 1 million times. DC power supply failure Stop The DC power supply has failed (due to abnormal high temperature) or an irregular voltage has occurred or the thermo-module has been short-circuited. Internal temp. sensor high temp. error Stop The internal temperature sensor has exceeded the upper limit of cut-off temperature. Internal temp. sensor low temp. error Stop The internal temperature sensor has exceeded the lower limit of cut-off temperature. Thermostat alarm Stop The thermostat has been activated due to insufficient of the facility water or high temperature. Abnormal output alarm The temperature cannot be changed even at 1% output due to overload or disconnection Continue of the thermo-module. Pump failure 1 or low circulating fluid level alarm 2 Stop The pump has been overloaded 1 or the flow switch is activated 2. Internal temp. sensor disconnection alarm Stop The internal temperature sensor has been disconnected or short-circuited. External temp. sensor The external temperature sensor has been disconnected or short-circuited. (Only detected Continue disconnection alarm when in learning control or external tune control.) Abnormal auto tuning alarm Stop Auto tuning has not been completed within 2 minutes. Low fluid level alarm 3 Stop The amount of circulating fluid in the tank has dropped and the level switch is activated. 1 The 12 only 2 Optional for the 1 and 3 only (Not available for the 6) 3 Optional for the 1 and 3 4 The 1 and 3 only Maintenance Maintenance of this unit is performed only in the form of return to and repair at SMC s site. As a rule, SMC will not conduct on-site maintenance. Separately, the following parts have a limited life and need to be replaced before the life ends. Parts Life Expectation Description Pump Fan DC power supply Display panel Expected life 3 to 5 years 5 to 1 years 5 to 1 years 5, hours (approx. 5 years) Possible failure The bearing is worn so the pump fails to transfer the circulating fluid, which results in temperature control failure. The bearing uses up lubrication and makes the fan unable to supply enough air, which increases the internal temperature of the thermo-con, and activates the overheat protection of the power supply and generates the alarm. The capacity of the electrolytic condenser decreases, and causes abnormal voltage which results in DC power supply failure and stops the thermo-con. The display turns off when the backlight of the LCD reaches the end of its life. 332

-W Series Options Note) Options have to be selected when ordering the thermo-con. It is not possible to add them after purchasing the unit. F This is an ON/OFF switch detecting low levels of the circulating fluid. When the fluid volume is 1 L/min. or less, ERR16 is displayed and the thermo-con stops. This switch is installed between the circulating fluid inlet and the tank, and built into the Thermo-con. Refer to page 35. N Option symbol NPT Thread N NPT thread The connection parts of circulating fluid piping, facility water piping and circulating fluid drain port are NPT thread type. L Option symbol With Flow Switch Option symbol F With Level Switch With flow switch 1/15 H H E HRZ HRZD HRW R HEB HED HEA IDH L With level switch This switch is used to detect a LOW level of tank fluid. When the fluid level becomes below the LOW level, ERR2 is displayed and the thermo-con stops. This switch is installed in the circulating fluid tank and built into the thermo-con. Refer to page 35. Type Type Applicable model Watercooled 1-W5-F 3-W5-F Type Applicable model 1-W5-N Watercooled 6-W2-N 3-W5-N 12-W2-N Watercooled Applicable model 1-W5-L 3-W5-L Other models include a level switch as standard equipment. 333

-W Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to back page 5 for Safety Instructions and pages 13 to 16 for Temperature Control Equipment Precautions. Warning 1. This catalog shows the specifications of the thermo-con. 1. Check detailed specifications in the separate Product Specifications, and evaluate the compatibility of the thermo-con with customer s system. 2. Although the protection circuit as a single unit is installed, the customer is requested to carry out the safety design for the whole system. Warning System Design Operating Environment/Storage Environment Warning Handling 1. Thoroughly read the Operation Manual. Read the Operation Manual completely before operation, and keep this manual available whenever necessary. 2. If the set temperature is repeatedly changed by 1 C or more, the thermo-con may fail in short periods of time. 1. Keep within the specified ambient temperature and humidity range. Also, if the set temperature is too low, condensation may form on the inside of the thermo-con or the surface of piping even within the specified ambient temperature range. Dew condensation can cause failure, and so must be avoided by considering operating conditions. 2. The thermo-con is not designed for clean room usage. The pump and fan generate dust. 3. Low molecular siloxane can damage the contact of the relay. Use the thermo-con in a place free from low molecular siloxane. 334 Operating Environment/Storage Environment Warning 4. Installation conditions If the space for the intake and discharge of air is insufficient, the amount of transferred air will decrease, which can impair the performance and life of the product. Therefore, keep the conditions illustrated below for installation. Also, if ambient temperature is expected to be over 35 C, vent or exhaust air to prevent the increase of ambient temperature over 35 C. <6/12> Intake 1 mm or more Discharge Leave space 15 mm or more Intake 1 mm or more Leave space 1 mm or Intake more <1/3> It is not necessary to leave space for ventilation. Install the product while taking working space for installation and maintenance into account. However, ventilation must be also considered so that ambient temperature does not excessively rise. Caution Caution Facility Water 1. If the temperature of the facility water is too low, it can cause formation of dew condensation inside the heat exchanger. Supply facility water with a temperature over the atmospheric dew point to avoid the formation of dew condensation. 2. If the facility water piping is connected to multiple machines, the facility water exchanges heat at the upstream side and its temperature will become higher as it goes downstream. Limit the number of connected thermo-cons to two per facility water system, and if more than two thermo-cons are to be connected, increase the number of systems. Circulating Fluid 1. Use tap water or fluid which will not damage the wetted parts material as described in this catalog s specifications. (PPE, PP glass 1%, Alumina ceramics, Carbon, EPDM, Stainless steel 33, Stainless steel 34, PE, PP, NBR) 2. Deionized water (with an electrical conductivity of approx. 1 µs/cm) can be used, but may lose its electrical conductivity.