Solar Hot Water. PV + Heat Pump or Thermal. Which is better?

Similar documents
Solar Hot Water Heating Systems

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

Solar Water Heating Basics for Homeowners

Heat Pump Water Heaters: A Key Energy Technology for California

SOLAR HOT WATER HEATERS

How to Heat Water in All-Electric Homes & Apartments?

ART TEC Solar Differential Temperature Controller DTC-1 Manual

Product Offering for 2017

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

Performance of Solar Water Heating Systems in the United States

A Self-Pumped. Solar Hot Water System. Story & photos by Andy Kerr. Comment Discuss

Heat Pump Water Heater Commercial Leaflet 2012

Energy Efficient Options for Residential Water Heating

Solar energy never looked so good!!

Selecting a New Water Heater

Residential Solar Water Heater

Applications of Thermodynamics: Heat Pumps and Refrigerators

CNC type Solar Air Conditioner

Heat Pump Water Heater Technology Development. EEBA High Performance Home Summit Ed Vineyard Oak Ridge National Laboratory

Residential Water Heating

COOLING SYSTEM ECONOMICS. How much is my water treatment really costing? Is Bon Aqua treatment the right choice?

Energy-Efficiency Options for Residential Water Heating

...WHY WAIT? IT S TIME TO SWITCH TO A NORITZ TANKLESS

GEOTHERMAL DESIGN GUIDE

Advanced Heating & Hot Water Systems. Solar Water Heating Clean Green Energy

THE HEAT PUMP CHOICE OF PROFESSIONALS

CONTENTS TABLE OF PREFACE- A QUICK GLANCE AT THE GEOTHERMAL INDUSTRY INTRODUCTION- NEARLY HALF OF ALL HVAC SYSTEMS ARE INCORRECTLY INSTALLED

So far, we have covered the basic concepts of heat transfer and properties.

That s why we call it Smarter from the Ground Up.

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

Savings Without Sacrifice

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Marketing Strategies for Energy Star Water Heaters. Keith Burkhardt Marketing Manager, Water Heaters GE Appliances

Natural geothermal energy

The Evolution of. Hot Water. Generation Systems. -Ron George. Geysir at Haukadalur, Iceland ( Ron George, 2016)

Sweden s leading air source heat pump

Solar Heat Pumps Domestic Range

FREQUENTLY ASKED QUESTIONS

Hot Water Distribution System Losses in a Net-Zero Home

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Tubular Skylights aka Solar tubes aka Tubular Daylighting Devices (TDDs) ENERGY STAR windowto-door. After

Trim Pump Impellers. Fredrick/Weinman Engineered Products 2-1/2 KH, 2-1/2 x 3 x 12

Outdoor Reset Control Theory FULL versus PARTIAL reset

Adding More Fan Power Can Be a Good Thing

Heat Your Water with the Sun

CONDENSING BOILER TECHNOLOGY. James Romersberger Quintessence Corporation

Adsorption Chillers Energysmart Green Cooling

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

U.S. Department of Energy - Energy Efficiency and Renewable Energy

FORCED AIR + HYDRONIC

advanced : technology

Solar Water Heating CLEARINGHOUSE

Consumer Features & Benefits of Energy Efficient Products

Evaluating Domestic Water Heater Performance for NY Homes NYSERDA Agreement 15606

25 per cent of energy used in the home is used to heat water.

ACTIVE SOLAR SYSTEMS

Scale Stopper Plus Installation & Start-Up Guide

dissipation: air conditioning, compressed air and heat exchangers. Air conditioning was

Solar Hot Water - Naturally the smarter choice

Energy Efficiency Programs in Action

Heat Pump Water Heater

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

NAECA Water Heaters. Tankless (Instantaneous) < 2 gallons Natural Gas 75,000 Btu 200,000 Btu Oil 105,000 Btu 210,000 Btu Electric

Solar Boiler. Solar Domestic Hot Water System Technical Specifications SRCC Certification # A CSA # A. General Information

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

DAIKIN Modular Inverter Air Cooled Chiller

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University

Reduce Energy Costs with Vapor Degreasing. Mike Jones MicroCare Corp., New Britain, CT

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

THERMAL ICE STORAGE: Application & Design Guide

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

Dr. Riaan Rankin & Dr. Martin van Eldik M-Tech Industrial (Pty) Ltd / North-West University October 2010.

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

A smarter, healthier way to live.

Geothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal

Nirvana. Cycling Refrigerated Dryers

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Rural Electrification, DC Microgrids and Off-Grid Appliances. Informal Session Aníbal de Almeida, Pedro Moura

EVI + INVERTER MODELS A Q U A P U R A

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

PROGRESSIVTUBE PASSIVE SOLAR WATER HEATING SYSTEM

Green economy with natural refrigerants

SuperStor Ultra Stainless Steel Storage Tank

Sanitation: Ware Washers, Water Heaters and the Plumbing of the Future

Riverdale NetZero Project Summary of Costs and Expected Performance

HEAT-PUMP HOT WATER. General operation. Heat-pump hot water services apply the same technology used

Owner Manual Pre-Heat Appliances Single Wall Heat Exchanger

SPACE CONDITIONING IN RESIDENTIAL BUILDINGS

Energy, Environmental, and Economic Analysis of Residential Water Heating Systems September 2010

Energy Options for Residential Heating. Juergen Korn, P.Eng.

ECOMax-HE Automatic Tube Cleaning System

Understanding Solar Types

User s Information Manual

Michael C. Parker Vice President Marketing & Strategic Planning

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

Heat Pump Water Heaters

Water Heating. Types of Water Heaters It's a good idea to know the different types of water heaters available before you purchase one:

Transcription:

Solar Hot Water Which is better? PV + Heat Pump or Thermal http://www.halslater.com/solar-hot-water.htm

Solar thermal is temperamental, really. Water weight limits design Expands when it freezes Steam and scale damage pipes when it boils Solar thermal systems are efficient but rarely use all of it Some systems work fine for decades, with regular inspections When solar thermal system fails it tries to destroying itself Use STHW when regular maintenance can be assured

The wisdom has been Efficiency outweighs convenience of electric. Since thermal collects more energy, PV powered conventional electric will never compete Then 2.5 EF heat pump water heaters arrived Then the cost of PV fell by 75%

The New Reality Lower solar electric (PV) costs; $3.00-$5.00/Watt DOE SunShot 2020 targets: $1.50 res; $1.00 util A new model: air source heat pump water heating (AWHP) with solar electric offset Heat pump is mature technology AWHP has fewer drawbacks than solar thermal Has a smaller price tag for residential applications

Has already begun

PV+HP Assumptions Using a heat pump water heater with Energy Factor of (EF) of 2.5 or more An 1,800 kwh per year Energy Star rating Adding a grid-tied NEM system with 1.0 kw to 1.3 kw of PV (50-90 sf) Where PV produces at least 1400 kwh/kwp/year

PV Advantages

Lower upfront cost Low-cost open systems proven unsuitable Cost of 80% solar thermal closed loop - glycol or drainback two-tank - or storage plus tankless 40-64 square feet of flat-plate collector Total cost $7,000 to $10,000 before incentives. Cost of 100% PV offset heat pump water heater $1,500 to $2,500 for the heat pump with labor $3,500 to $6,000 for grid-tied PV Total cost $5,000 to $8,500 before incentives.

Easier to install Photovoltaic Replace a water heater with another single tank Add three to five modules to PV system. or Solar Thermal Replace a single tank with two tanks Pipe heat transfer fluid to rooftop panels Pressure test and charge after installation. Which has fewer opportunities for installer error?

Uses less space Two tanks are required for thermal One for the backup, and one for the solar Competing with backup limits solar fraction to ~60% Can use tankless heater if it modulates enough Adds to equipment and installation cost May need larger gas line Cold water sandwich effect

Needs no maintenance The Achilles Heel of solar thermal is If the system stops working, it wants to self-destruct Without flow, the panels can Freeze, warp, boil, scale, coat, burst and/or clog These should be inspected yearly Panels Electronic controller Circulator pump Piping for scale or corrosion, especially for drainback Older buildings that may settle and trap fluid Annual inspections could cost half of the gas savings

Cannot freeze Solar panel can freeze at 42ºF Freeze protection is required for all mainland US Except for drainback, freeze protection is "active Need device to operate only at low temperature. Rarely required to function Failures are common and catastrophic Thousands of dollars in damage to collectors Systems turned off then removed v. repaired

Cannot overheat Frequently overlooked in product and system design Twice as much solar energy in July as in January Enough heat in January will overheat in July Panels stagnate at 400ºF inside Damages and accelerates deterioration No data on how radiator much to use

No scale build up Scale is the enemy of water heaters of all types Heat makes dissolved solids precipitate from water They bind to hot surfaces Scale can clog the heat exchanger Lower temperatures in heat pump reduce scale

100% solar fraction No 100% reliable thermal system has 100% fraction Best SRCC OG300 systems have 90% solar fraction NEM allows storage of power for up to a year Comparison is 80% for thermal but 100% for PV

Demand management AWHP adds load to the grid when replacing gas PV adds power to the grid during peak demand hours Most domestic hot water is used off-peak The utility could use this to store excess electricity but Add ability to overheat water through the smart meter Use with a mixing valve to prevent scalding Remotely manage operation of the compressor or element Store twice as much energy as used with AWHP

Net gas efficiency Electric Tank Gas Tank AWHP Gas Tankless Rated EF 0.92 0.67 2.5 0.92 Elec:Gas EF 0.33 1.0 0.33 1.0 Net Gas EF 0.30 0.67 0.83 0.92 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 2 3 4

No CO2 emissions Gas combustion backup adds CO2 IPCC says it is the #1 risk facing civilization today PV + HP produces no GHGs while operating Lower GHGs in producing less equipment

Disadvantages

Warm air required Efficiency depends upon heat source for air in space In temperate climates, yields higher EF If space is heated, energy comes from heat source If cold, use of backup element lowers net efficiency APWH will cool and dehumidify the space

Newer on the market Household AWHP only 20 years of development First were add-on units 2004 ORNL optimized single tank design Energy Star rated water heaters: 500 solar thermal models 600 tankless ("instant ) Only 23 APWH models. Proven core technology vapor compression

Noise level Heat pumps use compressor and fan for air flow As much noise as a small, modern refrigerator If the unit is inside, the sound may be a problem Fan air makes more noise than compressor

Conclusion Solar thermal technology is an improvement over fossil Has legitimate applications with regular maintenance Household-level solar hot water has many drawbacks Solar photovoltaic is highly-effective, low maintenance APWH is the optimal selection for many households, depending on climate and configuration W2W heat pump water heaters may become available

Question & Answer

Best LinkedIn response: This is a discussion that will have as many opinions as there are readers. One reason that thermal gets a bad rap is our past history in the 80s where open loop systems with freeze valves or sunspool valves failed and systems froze. Then we have had instances of glycol stagnation issues turning acidic and into a jello like substance which plugged the heat exchangers. Here in Florida, we are seeing issues with water quality for various reasons; scaling from calcium carbonate and copper corrosion from salt water intrusion to fresh water sources. Normally, calcium and chlorine are not huge issues in residential plumbing but when you pipe the water in an open loop system and run it through a collector that might stagnate to 250F, you accelerate the reaction rates dramatically. Yet, we now have strategies that can handle these, ie closed loop drainback systems. John L Alger, P.E., Manager, Engineering and Commercial Projects, AET Solar, LLC

Thermal Advantages Plus, consider that you need much less roof area for collectors. My home has a 4.86kW PV array which requires 27 panels. My thermal array is 2qty 4x8 panels [64 sf] and generates the same equivalent. Why would I use such a precious and sophisticated product like electricity, just to warm up water? The use of both technologies is really the best. The 1-1.3kW array needed will be 50-70 sf. I do not see a real difference in the sophistication of the energies or the relevance. AWHP uses mostly air.

With regards to heat pump water heaters New data suggests that there are some significant considerations including but not limited to: I will respond.

1. Weight of the unit In some cases the flooring needs to be reinforced Why? The main issue is still the weight of 50 gallons of water, the compressor adds under about 100 lbs.

2. Maintenance It is an air conditioner with a filter that needs to be replaced. That is not mentioned in any of the manuals I found but is a very minor action, if true.

3. Access It can not be placed in a position next to a wall where the flow of air is impeded. That depends on the air flow direction through the heat pump, the unit can be rotated.

4. Design life While the HVAC side will last quite a while, 15 years perhaps like a heat pump, the actual durability is only as good as the life of the steel tank, Then, you have an expensive replacement in 6 to 10 years vs solar with a SS tank which does not rust or a DX drainback system which uses a simple steel glass lined tank that is inexpensive. The lower temperature of the wraparound condenser in the tank should eliminate the typical scaling found in water heaters but there are stainless tank HPWHs available, as well.

5. You need to add a condensate line Like an A/C system. That may not always be convenient to route depending on where the tank is located in the home. In most cases, the condensate line can be shared with the required T&P line

6. It works best in hot climates In northern areas, with cold water temperatures, the unit works mostly like a standard electric water heater since there is not enough latent heat energy in the surrounding air to transfer to water in the tank. this is the same reason that heat pumps are not commonly used in northern climates for space heating, the COP is too low to deliver any heat. True, depending upon what is meant by northern areas. Many labs and manufacturers that test and build AWHPs are in the northern states.

7. Who to call for service? Plumbers cannot service an HVAC system. Why not call an HVAC technician? Plumbers rarely perform any service on a water heater other than replacement, anyway.

There has been much talk lately about a PV powered electric water heater but again, why take a technology that can generate a product which is so versatile (electricity) and use it to warm up water? You answer your own question, electricity is versatile so, if you don t need warm water, you can still use the electricity.