Technical write-up on Fire safety services

Similar documents
Following are the systems proposed as per NBC & Local Fire Authority:

PROJECT: NITESH PALO Bangalore FIRE SAFETY MEASURES

Enclosure 4- RISK ASSESSMENT

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL

RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN

CHAPTER 8: RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN

DEPARTMENT OF FIRE & EMERGENCY SERVICES DNH.

NITOL INSURANCE COMPANY LIMITED

Delhi Metro System. Emergency and Fire Safety Measures in. - by Sanjeev Kumar & Kailash Chandra Joshi. Fire Protection & Safety

Govt. of West Bengal Online Clearance for Fire Safety Certificate and Renewal (Application for Fire Safety Recommendations)

Proposed Commercial Project at Plot No. C3A, Sector-16B, Greater Noida West (U.P)



SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

1.1.1 HAZARD IDENTIFICATION

7.2 SAFETY CODE FOR BUILDING & FIRE FIGHTING SYSTEM

FIRE SAFETY and COMPLIANCE

THE MAURITIUS FIRE AND RESCUE SERVICE ACT. Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act

RULES 1978 UNDERGROUND COAL MINES FIRE PRECAUTIONS

DEPARTMENT OF FIRE & EMERGENCY SERVICES DNH.

EE/ / To, Dear Sir,

HIGH PRESSURE WATER MIST SYSTEM Application: High Rise Building Bindreiter Michael London,

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

APPLICATION FOR FIRE CERTIFICATE / FIRE CLEARANCE UNDER THE MAURITIUS FIRE AND RESCUE SERVICE ACT 2013 OFFICE USE ONLY

Winnipeg Fire Department Fire Prevention Branch

BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

FUNDAMENTALS OF FIRE SAFETY

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

FIRE EMERGENCY ACTION PLAN (EAP)

BALAJI FIRE PROTECTION SYSTEMS:

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

FIRE PROTECTION SYSTEMS IN BURJ KHALIFA. By NAFFCO Fire Protection

Property Protect Risk Questionnaire (To be completed for all risks containing high hazard activities / processes)

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

APPLICATION FOR GRANT OF FINAL NO OBJECTION CERTIFICATE OF THE FACTORY/HOTEL/RESIDENTIAL CUM COMMERCIAL/HIGH RISE BUILDING AND OTHER OCCUPANCIES.

Fire Protection Coffee Break Training May 2016

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Fire Protection District Business Pre-Plan Form

Risk assessment is a term used to describe the overall process or method where you:

PREMISES FIRE SAFETY HANDBOOK

Fire protection on chemical manufacturing sites

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

HIGH-RISE RETROFIT ORDINANCES - NO and NO

TECHNICAL SPECIFICATIONS 167 CASTLEREAGH STREET

Chapter 5. Energy Conservation & Fire Safety

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

Fire Safety Concept Hotel Jumeirah

Unit 5: Fire Safety Installations

- CONSTRUCTION FIRE SAFETY STANDARDS

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

APPLICATION FOR GRANT OF PROVISIONAL CONSTRUCTION PERMISSION/FINAL NO OBJECTION CERTIFICATE OF FIRE & EMERGENCY SERVICES.

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Active & Passive Fire Protection System. Page 1 Kalidasan S BT IN SSP-OP

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Fire Protection System and Life Safety Evaluation of Building X. Anthony W. Sublett

GENERAL AREAS OF INSPECTION

Fire Sprinkler Plan Submittal Form

Fire Risk Assessment

RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT

Technical Information

RAMBLER PARK FIRE SAFETY INFORMATION

Project: Location: Date Prepared: Last Reviewed:

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Certification Assessment Instrument and Guidelines

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Module 9: Ontario Building Code Fire Fighting Provisions

Guidelines for Fire Safety Plans at Construction or Demolition Sites

Safety Manual: Emergency Response

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

Fire Prevention Plan

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) PRICED BILL OF QUANTITIES

4 August Islington Fire Protection Transpower NZ Limited

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

RISK ASSESSMENT AND HAZARD MANAGEMENT

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

Agency for Health Care Administration

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

University of London

What you need to know about. Maintaining essential safety measures in your building

Transcription:

1. General: Technical write-up on Fire safety services Nitesh Santa Clara, proposed development is a residential apartment with multiple blocks. Document briefs on fire safety systems envisaged for the facility such as water storage capacity, fire protection, detection & public address system with talk back facility. 2. Codes & standards referred: National Building Code (NBC 2005) - Part 4 Karnataka State Fire & Emergency Services (KSFS) IS 15683 for portable fire extinguishers IS 15105 for sprinkler system IS 2189 for fire alarm & detection system 3. Fire fighting system: Fire protection systems are proposed to meet requirements of local fire authority having jurisdiction & will be designed as per NBC 2005 part IV. Facility is categorised as "Residential Building group-a, sub division A4 (apartment houses)". 4. Sumps, OHT's & Pumps: As per local fire authority requirement, dedicated over head storage tank of capacity 10 CUM is proposed for block connected to the wet riser/down comer system. Underground sump of capacity 50CUM is proposed in the basement catering external yard hydrants & sprinkler system (proposed in basement). One set of pump is proposed to cater yard hydrants around the periphery of building, wet risers & sprinklers in basement. End suction top discharge pumps of suitable head will be proposed to cater vertical zones. Maximum pressure at any hydrant point shall be limited to 7 bar. Sl. No Description Residential Tower 1 Fire reserve - UG Sump 50 m³. 2 Fire reserve - OHT 10 m³ per riser 3 Motor driven end suction top discharge jockey pump 01 Number - 180LPM 4 Motor driven end suction top discharge main pump 01 Number - 2280LPM head 5 Diesel engine driven end suction top discharge stand-by pump 01 Number - 2280LPM 5. Hydrant system: Page 1

Main hydrant system consists of G.I C class pipes, isolation valves, hoses, hydrants, nozzles, hose cabinets located as per NBC requirements at every floor near stair cases as per local fire authority recommendation. Every floor is provided with wet riser/down comer along with single headed internal hydrant valves for every 1000sq.m of floor area near fire fighting stairs/lobbies as required. Each wet riser will be connected to terrace tank of capacity highlighted above. Landing hydrants are provided in basements for every 1000sq.m floor area. Location of these hydrants shall be such that, they are easy to access in case of emergency. Yard hydrants are proposed around the periphery of the building at an interval of 60mts along with hose cabinet capable to house branch pipe & hose pipe. 6. First aid portable fire extinguishers: Hand held extinguishers of suitable capacity will be proposed as per IS: 15683. ABC type extinguishers are shall be located inside staircase landing at each level, car parking area in basement, pump house, transformer, electrical panel, etc. as per statutory requirements. Mechanical foam extinguishers shall be used near pump house, transformer yard. All the fire extinguishers shall be free from halon & other gases which have ozone depletion potential. Each flat kitchen will be provided with ABC type extinguisher of capacity 2Kgs. Fire buckets are proposed @ an interval of one set for every 8 car parks in the basements. 7. Automatic Sprinkler system: System proposed consists of providing sprinkler protection at ceiling of basement floor level with specified spacing as per statutory requirement. Water for sprinkler system is tapped from wet riser with Installation control valve. G.I C class pipe with fittings, sprinklers, flow switches, drain valves located at strategic points as per statutory requirement. Pendent sprinklers are proposed in basements, lift lobbies & side wall sprinklers in basement ramp areas. Flow switches will be envisaged to detect activation of sprinklers. Same will be integrated with fire alarm system. Following sprinklers are proposed for different areas in the building. Colour of the Sl. No Sprinkler Type K - factor Size of the bulb bulb 01 Std. response Pendent sprinkler 5.6 (80.6) 5mm Red 02 Std. response Sidewall sprinkler 5.6 (80.6) 5mm Red 8. Fire brigade connection: One 4-way fire brigade inlet will be proposed for connection with hydrant system & to fill the fire sump. This shall comprise of 4 instantaneous male inlet couplings, plugs & chains and. Page 2

9. Talk back PA System: Main objective of PA system is to convey clear & audible instructions (as per NBC) to all people on all floors / buildings in case of fire / other emergency to reach a place of safety outside the buildings. Proposed system scheme consists of Talk back speakers near staircase exits @ all levels Amplifiers sized to suit to number of speakers. Talk back console with goose neck, zone selection & other features. Switching unit. Speaker monitoring system Wall mounted talk back speakers proposed are of 6W. Each tower will have one console, switching unit & amplifiers connected to tower level speakers. 10. Manual/Conventional fire alarm system: Residential tower is proposed with manual fire alarm system. A control panel will be provided in apartment lobby/reception at ground floor. Each floor will be considered as one single zone. Hooters linked to specifc zone will be triggerd once the manual pull stations are operated. Clubhouse will be proposed with smoke/heat detectors as applicable & will be connected to the respective control panel. System operation: MCP, hooter & talk back speakers will be installed at all exits for convenient & quick way of raising an alarm. Manual call points help the occupants to inform other occupants & security personnel about fire break out while they evacuate themselves from the floor. 11. Fire Lift: To enable fire service personnel to reach upper floors with minimum delay, fire lifts are proposed & shall be available for exclusive use of firemen in an emergency. Lifts shall have a floor area of not less than 1.4m². It shall have loading capacity of not less than 545kg. (8 persons lift) with automatic closing doors of minimum 0.8m width. At least one lift in each block will be considered as a fire lift. Page 3