Taut Wire intrusion detection sensor (TWIDS)

Similar documents
Fiber Optic Cable Fence Disturbance Sensor

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Buried ported coaxial cable outdoor intrusion detection system

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Microphonic Cable Fence Disturbance Sensor (multiplex version)

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

TW-8000 TAUT WIRE FENCE

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

Architectural and Engineering Specification for a Personal Alarm System System (PAS)

Architectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000

WG Buried Cable Perimeter Detection System

Product Specifications

Architectural and Engineering Specification for a. Flash / Flare

Product Specification

Alarm annunciation, control and communication systems

Architectural and Engineering Specification for a Real-Time Locating System Flare

Presented By. BEI Security

INTREPID Buried Cable Perimeter Intrusion Detection System

The. Long Beach, California August 14-17, Solutions Network. Physical Security PERIMETER SECURITY TECHNOLOGIES. Leon Snyman GVI Security, Inc.

INTREPID Buried Cable Perimeter Intrusion Detection System

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

Perimeter Intrusion Detection System

WG Buried Fibre Cable Long Perimeter Detection System

Airport Perimeter Security

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Intelli-FLEX Perimeter Protection System-Relay Output Processor. product guide. (DC/DC relay version)

PERIMETER DEFENCE. Panorama Intruder Detection System Long Range, Day & Night, Automatic Panorama Intruder Detection

ADPRO PRO Series by Xtralis

Section PERIMETER SECURITY SYSTEMS

INTREPID Perimeter Intrusion Detection System

Architectural and Engineering Specification for a Security Management System. StarNet 2

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Pipeline Intrastructure Monitoring for Third-Party Interference Detection

Manufacturer of perimeter protection systems. Perimeter first line of protection. Microwave Bistatic Detectors. Microwave Monostatic Detectors

TOTAL PERIMETER SOLUTION

The Fiber SenSys Perimeter Intrusion Detection System From JM Fiber Optics!

G.M. Advanced Fencing & Security Technologies Ltd

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Minimal Electric Charge Detection Device for Perimeter Security Systems

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Committed to security

Product Specifications

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Perimeter security using Fibre optics

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Installation Instructions

KM300 Carbon Monoxide Detection System Installation Manual

Immunity. P/N: ver.b

NSB-200S HOME INTRUSION DETECTION SYSTEM

Perimeter Product Overview. Effective protection for your business

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Environmental Monitoring Card

Model GPT 3 Freeze Protection Thermostat

SensaGuard TM Integrated Latch Installation Instructions

TOTAL PERIMETER SOLUTION

Environmental Monitoring SmartSlot Card

J. D. Williams ADVANCED TECHNOLOGIES FOR PERIMETER INTRUSION DETECTION SENSORS. Sandia National Laboratories, United States of America*

AlarmLine Addressable Linear Heat Detector

Electromagnetic Locking Devices Performance Requirements

FiberSensor Fiber Optic Intrusion Detection System (IDS)

SECTION AUTOMATIC TRANSFER SWITCHES

Long-Range Barrier Sensors

Twin Photobeam Detectors Manual

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Praetorian Fibre Optic Sensing

CARD ACCESS CONTROL SYSTEM

suite of security systems

BID SPECIFICATIONS FOR (NAME OF ENTITY) COMMUNITY OUTDOOR WARNING SIRENS

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

MICROPOINT to MICROPOINT II UPGRADE

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Intrusion Outdoor Protection Perimeter

Fiber SenSys. Fiber Optic Perimeter Detection Systems. Substation Physical Security Best Practices Baltimore 2017

PERIMETER FIBRE OPTIC PERIMETER PROTECTION SNAKE

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

www. rbtec.com

Gallagher Perimeter Product Overview

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Guardrail and Barrier Systems

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Flame Rod Manual. Publication Rev A

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

Gallagher D10 Tautwire Sensors & D21 Disturbance Sensors Integration with Gallagher

Document No

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

P E R I M E T E R m i n i c a t a l o g u e

Intrusion. Outdoor protection perimeter

Gardian W51. Approvals

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Radar Sensor. Radar Security Detector Model No. : DND-30L/30W, DND-60L/60W, DND-90L/90W. Feature. Specification. Reference

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Transcription:

Architectural & Engineering Specification for Taut Wire intrusion detection sensor (TWIDS) Purpose of document This document is intended to provide performance specifications and operational requirements for the DTR-2000 Taut Wire Intrusion Detection Sensor. It is written in a generic format without referring to the system by name or by specific identifiers. These specifications may be copied verbatim to form a generic procurement specification for taut wire barrier intrusion detection system. Classification of equipment DTR-2000 is a tensioned wire sensor system employing an array of tensioned wires and electromechanical sensors for outdoor perimeter intrusion detection. Disclaimer Crossfire, Senstar and the Senstar logo are trademarks of Senstar Corporation. All information in this document is subject to change without notice. Senstar reserves the rights to make changes to product design or manufacturing methods, as engineering progresses or as other circumstances warrant. Copyright 2011. Senstar Corporation. All rights reserved. Printed in Canada. R5DA0115-001, Rev B page 1 May, 2011

May, 2011 page 2 R5DA0115-001, Rev B

Contents 1.0 General performance specifications... 5 2.0 Sensor processor specifications... 9 3.0 System installation and commissioning...10 4.0 System maintenance and repair...11 5.0 Product certifications...11 6.0 System availability...12 R5DA0115-001, Rev B page 3 May, 2011

May, 2011 page 4 R5DA0115-001, Rev B

1.0 General performance specifications 1.1 System description The system shall be a horizontal array of parallel, pre-tensioned barbed or barbless wires attached to sensors to form a combined fence and sensor. The wires shall be attached to anchor posts at each end of a sector and the sensors shall be mounted to a sensor post located typically midway between the anchor posts. A specialized electromechanical switch monitors two wires. The switch activates whenever a force is applied to a wire that corresponds to: - spreading the wires - climbing over the wires - cutting any wire - leaning a ladder on the array and climbing over For multiple wire systems, multiple independent switches shall be required. 1.2 System technology 1.2.1 Taut Wire Array The horizontal tensioned wires shall have a typical separation of 10 cm (4 in.). They shall be supported by various sliding devices in such a way that any vertical motion of the wires is translated into horizontal wire movement at the sensors. A vertical displacement of 8 cm (3.1 in.) of any wire shall be sufficient to cause an intrusion alarm. 1.2.2 Electromechanical Sensors The sensors shall be self-adjusting electromechanical switches, sealed and containing a special dampening material so as to inhibit activation from environmental changes, without decreasing sensitivity to human attempts at intrusion. 1.3 Detection properties 1.3.1 Detection sensitivity The system shall detect intruders with a significant mass (size) while rejecting other environmental stimuli. 1.3.2 Detection performance 1.3.2.1 Probability of detection (PD) The probability of detecting a human intruder passing through the perimeter at random locations shall be greater than 97% with a 95% confidence factor. R5DA0115-001, Rev B page 5 May, 2011

1.3.2.2 Intruder weight The system shall detect any intruder who applies pressure on the wires greater than 15 kg (33 lb.). 1.3.2.3 Intrusion types The system shall detect human intruders who spread, climb or cut the wires, or lean a ladder against or on the wire array and climb the ladder. The system shall incorporate special features to prevent clamping and cutting individual wires. The system shall also use breakaway tabs on the anchor posts as tie points for the individual wires. This will result in the release of the wires if an intruder attempts to climb the anchor post. 1.3.3 False/nuisance alarms False/nuisance alarms are divided into three categories, system-generated, small animal and environmental. 1.3.3.1 System-generated alarms (false alarms) Alarms generated by internal electronic processes shall occur at a rate of less than one per three months per kilometer of fence (averaged over a year and over the total number of zones in the system). 1.3.3.2 Small animal alarm rejection The system shall not detect an intruder who applies pressure on the wires less than 7 kg (15 lb.). 1.3.3.3 Environmental alarms (nuisance alarms) The system shall operate within specifications in typical outdoor environments. The system must be installed in accordance with the manufacturer's guidelines to minimize the possibility of nuisance alarms while maintaining the full PD for valid intruders. The following conditions shall not affect the system s PD: rain sunrise/sunset wind less than 70 km/h (43 mph) temperature changes snow hail fog sandstorms motion of nearby objects (vehicles, etc.) nearby radio-frequency sources May, 2011 page 6 R5DA0115-001, Rev B

seismic vibration acoustic or magnetic effects Before installation, the installer shall alert the customer, in writing, as to all sitespecific conditions, which may contribute to a higher environmental alarm rate. The customer shall decide whether to remedy the situation, or accept the environmental alarm sources without any further responsibility on the part of the installer or the manufacturer. 1.4 Sensor characteristics 1.4.1 Wire Characteristics The double braided with reverse twist barbed or barbless wire array shall contain galvanized or stainless wires of 14 AWG, with a high tensile strength of at least 9000 kg/cm 2 (130,000 PSI). The barbed wire shall have 4-point barbs. 1.4.2 Detection Sector and Reporting Alarm Zone lengths A detection sector shall consist of a wire array connected to two anchor posts and a sensor post. Sliding devices and intermediate spirals shall be used to maintain the wire array parallel and to increase translation of vertical movement of the wires into horizontal movement at the sensors. The maximum length of an individual sector shall be 60 m (200 ft.). The minimum sector length shall be 15 m (50 ft.) without specialized hardware. Two or more detection sectors may be combined to create a single reporting alarm zone. A reporting alarm zone can be of any length greater than 15 m (50 ft.) without specialized hardware. 1.4.3 Barrier Configuration The effective detection barrier shall be continuous and uniform over the protected site perimeter. A typical barrier shall have a height up to 2.0 m (6.6 ft.) above ground (based on twenty wires) plus a 0.8 m (2.6 ft.) outrigger (based on eight wires) inclined at 45 degrees to the vertical in a free-standing installation. Higher detection barriers and longer outriggers shall be possible by using more wires. Outriggers shall be capable of facing inward or outward or both (Y pattern). Outriggers shall be available in a standalone configuration for attachment at the top of a wall. 1.4.4 Terrain-following characteristics The detection barrier shall not be limited to line-of-sight operation. The zone length, detection barrier dimensions and performance characteristics shall be valid over uneven terrain including grade changes of up to 5 degrees. Steeper grade changes shall be possible with the installation of anchor posts or pulley posts at the ends of the grade and with the installation of the sensor post perpendicular to the grade. The wire array shall be parallel to the grade. R5DA0115-001, Rev B page 7 May, 2011

1.4.5 Range of containment The system shall not detect any object or creature that does not physically interact with the wire array. 1.5 Physical installation criteria 1.5.1 Physical installation The wire array shall be tensioned at the start or end of the zone and shall be supported every 3 m (10 ft.) by main spiral devices. The wires shall be further supported by intermediate spiral devices located midway between the main spirals. The wires shall be capable of being mounted, with or without outriggers, in the following configurations: Fence-mounted - on an existing, or new, perimeter fence Freestanding - on freestanding poles in an open area as the perimeter fence Roof-mounted - on rooftops or on the top of structures Wall-mounted on walls or on the sides of structures 1.5.2 Determination of zone length The length of each detection zone shall be determined by the physical boundaries of the site subject to the requirements of Section 1.4.2 above. 1.5.3 Location of signal processor The signal processor shall be mounted inside the sensor post. The optional standalone transponder shall be mounted either on the sensor post, or inside the perimeter at a secure location (e.g. on a post), or indoors. 1.5.4 Enclosures The signal processor shall be hermetically sealed and located inside the sensor post. For outdoor installations, the standalone transponder shall be housed in a weatherproof NEMA 4 enclosure. The enclosure shall be capable of being mounted on walls and posts. 1.5.5 Lightning protection The signal processor and the standalone transponder shall include internal components to protect circuitry from electrostatic discharge (ESD) and lightning. This protection shall include, but not be limited to, relay contacts, input power, and communication lines. The system shall comply with MIL- STD-9094 for Lightning and Electronic transients. May, 2011 page 8 R5DA0115-001, Rev B

The installer shall provide a solid earth ground that is properly connected to the enclosure. The installer shall follow standard industry procedures to provide separate grounding for the fence. 1.6 Performance history 1.6.1 Previous installations The system shall have been installed in at least ten similar configurations, at least five of which shall have a perimeter length greater than 5 km (3 mi.). A list of these projects shall be available. 1.6.2 Customer references The vendor shall submit the names and telephone numbers of at least four users who shall serve as references for the satisfactory performance of the equipment. These users shall have a minimum of one year s performance experience with the equipment. 2.0 Sensor processor specifications 2.1 Processor description The signal processor shall contain the electronics necessary to perform the collection and redistribution of sensor switch closure information. The processor shall operate as a networked unit, shall be hermetically sealed, and shall be located inside the sensor post with the sensor switch array. The sensor post shall have a tamper switch that activates when the sensor post cover is removed. Alternatively, a transponder shall be available to translate switch closure information into relay contact closures. It shall operate as a standalone unit and shall be housed in a weatherproof enclosure, when installed outdoors. The enclosure shall have a tamper switch that activates when the cover is opened. 2.2 Signal processor operation 2.2.1 Distributed processing Signal processors distributed along the perimeter shall perform the collection and redistribution of sensor switch closure information. The failure of one processor shall not affect the other processors along the perimeter. Each processor shall provide coverage for up to 60 m (200 ft.) of perimeter. 2.2.2 Total perimeter length Total perimeter length shall be expandable from the 60 m (200 ft.) maximum coverage of one processor to an unlimited length using multiple processors. There shall be uniform coverage and no gap in the detection barrier between individual zones. R5DA0115-001, Rev B page 9 May, 2011

2.2.3 Alarm outputs The signal processor shall identify, by type, intrusion, tamper and communications cable failure alarms. An alarm caused by an attempt to penetrate the wire array shall be identified as an intrusion alarm. The processor shall identify to the Central Controller in which group of wires, from a possible seven groups, that the intrusion has occurred. For a typical 2-m (6.6-ft.) fence height, this shall provide a vertical resolution of intrusion no greater than 50 cm (20 in.). An alarm caused by opening the enclosure of the sensor post and/or the signal processor shall be identified as a tamper alarm. Tamper alarms shall be distinctive from intrusion alarms and shall be reported as supervisory alarms. Alarms caused by power failure, internal electronic failure, or tampering with the communications cable shall be identified as fail alarms. Fail alarms shall be distinctive from intrusion alarms and shall be reported as supervisory alarms. Supervisory alarms shall continue until the fault is corrected. 2.2.4 Network transponder/device (optional) The processor shall be capable of being integrated into a CCC or Crossfire alarm data collection and distribution network. The processor shall function as a network transponder capable of communicating alarm data and diagnostic information to a Central Controller. 2.3 Environmental conditions The signal processor shall operate within specifications in the following range of conditions: Temperature: 40ºC ( 40ºF) to 72ºC (162ºF) Humidity: Up to 95%, non-condensing 2.4 Powering Requirements The signal processor shall be powered at 12 to 24 VDC. The standalone transponder shall accept an input voltage of 9 to 30 VDC. 2.5 Sensor calibration Once installed according to manufacturer s instructions, the sensors shall require no calibration. 3.0 System installation and commissioning The system shall be installed and commissioned in accordance with the manufacturers recommended procedures, as defined in the product's installation and setup guides. May, 2011 page 10 R5DA0115-001, Rev B

Prior to installation, the installer shall have completed a training program and be certified by the manufacturer. Alternatively, the installer shall be required to have the manufacturer, or their designate, provide qualified technical support for the installation and commissioning of the system. Acceptance tests shall be performed in accordance with standard procedures, available from the manufacturer. 4.0 System maintenance and repair System maintenance shall include periodic visual inspections of the site and operational checks of the effectiveness of the detection zones. 4.1 Recalibration requirements There shall be no requirement to recalibrate the system after initial calibration. 4.2 Product support The supplier shall provide technical support and warrant that spare parts and assemblies shall be available for a minimum of 10 years. 5.0 Product certifications The product shall be manufactured in accordance with ISO 9002 standards. All outdoor components shall comply with MIL-STD-810C. The system shall comply with MIL-STD-9094 for Lightning and Electronic transients. The system shall comply with MIL-STD-461/462 for Electromagnetic and Radio Frequency Interference (EMI/RFI). R5DA0115-001, Rev B page 11 May, 2011

6.0 System availability A product that meets or exceeds this specification is the DTR 2000 Taut Wire outdoor intrusion detection system, available from: Senstar Corporation 119 John Cavanaugh Drive Carp, Ontario Canada K0A 1L0 Telephone: (613) 839-5572 Fax: (613) 839-5830 Toll Free: 800 390-5796 Canada Toll Free: 800 676-3300 US www.senstar.com info@senstar.com May, 2011 page 12 R5DA0115-001, Rev B