WALK-THROUGH METAL DETECTOR

Similar documents
USER MANUAL. MT 5500 Model 11677xx. USA Garrett Metal Detectors Security Division 1881 W. State Street Garland, Texas USA

OWNER S MANUAL MAGNASCANNER PD 6500

For more than 35 years METOR metal detectors have been leading the way in the industry. Once again, METOR is setting new standards in metal detection.

MD-6 METAL DEFENDER MANUAL, TECHNICAL SPECIFICATIONS

Model 5060/5070. Letter Opener Revision 3 Brush Transport

PMD2 Plus series. Enhanced Walk-Through Metal Detectors. NEW. Threat Detection through Electromagnetics GENERATION

CEILING FAN OWNER'S MANUAL

The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

PMD2 Plus/EZHD. Elliptic, Multi-Zone and Heavy Duty

User MANUAL PD 6500i MODEL 11684xx

PMD2 Plus/EZHD. Elliptic, Multi-Zone and Heavy Duty. Superior Detection and Throughput. Very High Discrimination of Non-Threat Items

QD6310. Fixed Gas Detector Operation Manual

User MANUAL PD 6500i MODEL 11684xx

02PN20/EZHD ELLIPTIC, MULTI-ZONE AND HEAVY DUTY ENHANCED METAL DETECTOR

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

FREWIN STEAM SHOWER ENCLOSURE

PMD2 Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics. Superior Detection and Throughput

LEVENS STEAM SHOWER ENCLOSURE

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Detectores de armas metals SuperWand GARRETT manual ingles

PMD2 Plus. Enhanced Walk-Through Multi-Zone Metal Detector. new. Threat Detection through Electromagnetics. generation

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

Threat Detection through Electromagnetics

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 0905 FAOM15_0905

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

CEILING FAN OWNER S MANUAL

ARLEY STEAM SHOWER ENCLOSURE

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

CEILING FAN OWNER'S MANUAL

Campus Protection Universities and K 12

Operators Manual The Black Pearl

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

PMD2 Plus. Enhanced Walk-Through. Threat Detection through Electromagnetics. Superior Detection and Throughput

IR Speed Dome. Quick Guide UD.6L0201B1357A01

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

AP Air Ion Counter Instructions

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

CONTENT. 11.Specification

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

HI-PE Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR

Ceiling Fan Ow n e r s Manual

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-870-SH/S870 User Manual

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-830-SH/S830 User Manual

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

EVENT SECURITY MULTI-ZONE METAL DETECTOR

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

CEILING FAN OWNER'S MANUAL

HI-PE Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics. Applications.

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

Bose Home Theater Speakers. Owner s Guide

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

CEILING FAN OWNER'S MANUAL

FD 2052 AutoSeal 12/2007 OPERATOR MANUAL FOURTH EDITION

Infrared sauna SUN S Pure Infra User Manual

ADT Home Security Starter Kit. Setup Guide

TECHNICAL INFORMATION Super Scanner V Metal Detector Catalog No. MDWAND

D-TEK -MS Vehicle Loop Detector. Operating Instructions

Instruction Manual and Warranty

1. Quick start-up guide

Operation Guide 3408

OPERATING MANUAL OF SLIDING GATE TURNSTILE TPW-331EGS

Operation Guide 5510

DC200 Digital Dispenser Operating Manual

1126 Series Ceiling Mount PIR Motion Detector

OPERATOR S INSTRUCTION MANUAL

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual

Suits all KPF849 models

Rules for Safe Operation

SMOKE DETECTOR USERS GUIDE SMOKE DETECTOR SETUP GUIDE

Walk-Through Metal Detectors Technical Comparison Chart

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Table of Contents. What to Expect with. Mounting Options. Tools Needed

INSTALLATION INSTRUCTION for ceiling fan

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

INSTRUCTION BOOKLET. Suits all KTF816 models

Operating Instructions

CEILING FAN OWNER S MANUAL

Pioneer-R16 Gas Monitor Operator s Manual

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

COMPASS S3 S2 CALIBRATION

D-TECT 3 IP. GJD260 IP Motion Detector

ADT Home Security Starter Kit. Setup Guide

HAND HELD METAL DETECTOR

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

Factory-direct TV Lift Cabinets. Installing your TV on the Residential Lift

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Transcription:

WALK-THROUGH METAL DETECTOR OWNER S MANUAL MODEL TS-2000 SUNS International, LLC

1. Introduction The SUNS TS-2000 is a high-quality walkthrough metal detector that provides superior metal discrimination and detection. It is ideal for use at airports, industrial sites, government buildings, schools, hospitals, conferences, sport events, or anywhere you need security. It features advanced circuit automatically suppresses or eliminates electrical interference associated with x-ray devices, video monitors and communications equipment, helping to reduce the likelihood of nuisance alarms and improving traffic throughput. A bright, highly visible LED (Light Emitting Diode) bar graph and lights indicating ready and alarm conditions make it easy for the operator to interpret operating information. The LCD with backlit for easy viewing, located in the overhead panel, reports operational information, such as password, volume and sensitivity setting etc. 2. Description: LED BAR GRAPH READY LIGHT ALARM LIGHT LCD PANEL Figure 1 2.1 DISPLAY PANEL 2.1.1 LED BAR GRAPH This LED display at the top of the Control Panel indicates the detection intensity which is based on the amount and composition of metallic objects passing through the unit. 2.1.2. READY LIGHT This green light appears when full power has been turned on and the unit is ready to operate. The light will also indicate when an individual inspection has been completed by the unit and it is ready to accept the next person. Operators should make certain the green light is visible before any individual is permitted to pass through the detector. 2.1.3. LCD PANEL Large alpha/numeric LCD below the Bar Graph reports all operating and setup information of the unit. 2.1.4. ALARM LIGHT This red light appears when the unit detects a targeted amount of metal on an individual, according to Sensitivity level setting.

2.2 TouchPads 2.2.1 ON Whenever this touchpad is pressed, the SUNS TS-2000 activates all circuits, initiates a self-test and places the unit in the Operating Mode within (60) seconds. 2.2.2 OFF When this touchpad is pressed, the unit turns off. 2.2.3 SENSOR - SENSITITY ADJUSTMENT When this touchpad is pressed, the sensitivity level can be increased or decreased and the actual sensitivity setting will be displayed (1-99). 2.2.4 VOLUME When this touchpad is pressed, the volume level of the unit s audible alarm will be shown on the LCD display (0-9) and the actual volume of the alarm will be heard. 3. INSTALLATION INSTRUCTIONS 3.1 Site Selection The SUNS TS-2000 walk through metal detector should be located on a level, stable floor with no large metal items within three (3) feet. Any nearby large metallic object can interfere with operation of the detector. Moving metallic objects, such as an escalator or revolving door, close to the detector can cause false alarms. Such alarms can also be caused by electrical interference from radio telephones, television monitors, powerful electronic motors and transformers, power cables and control circuits. Special built-in circuitry is designed to suppress much of this electronic noise, especially X-ray monitor horizontal synchronization signals and closed circuit television. The site for a SUNS TS-2000 should be selected with requirements for its pedestrian traffic and use in mind; i.e. space for waiting lines, operators and areas for hand-scanning. Although the detector is effective with traffic moving in either direction, best results are obtained when traffic enters from the side opposite to the control touchpads and LCD display. Locate the archway where it will not be subject to rain, mist or condensation. Protect the power cable from pedestrian as well as vehicular traffic. 3.2 ASSEMBLY 1. Lay out the major pieces of the SUNS TS-2000, as shown at the right. 2. Connect Power Cord to the control unit. 3. Place the styrofoam packing material on floor and lay the Control Unit on it with the touchpad panel facing down. Use four (4) of the Screws and Finishing Washers to connect the Detection Unit to Panels A and B. Do not tighten.

4. Open door of the Control Unit and, first connect two RS-232 connectors to left and right panel. If the main power supply comes from top, you can connect the power cord directly from control unit to power supply. If the power supply is close to floor, you need to decide which panel to connect. (Both panels are prewired). Plug the power cord to the side of panel of your choice and connect the another power cord from bottom of the panel you choose to the main power supply as illustrated below. inside control box connect to main power supply 5. Use the remaining screws and washers to attach the Crosspiece to the two panels. 6. Tighten all four screws securely with a slotted screwdriver. 7. With two or more people lift to a vertical position and move to location. 8. Check for stability of unit, which is important for proper operation and safety. If the floor proves to be uneven, either shim a corner or slightly loosen the screws connecting the Detection Unit and Overhead Crosspiece to the Side Panels and adjust as necessary. 4. OPERATIONS 4.1. Basic Start Up Operation 1. Turn the unit on by momentarily pushing the ON button on the touch panel. The unit will power up and begin a self-diagnostic check. SUNS will be displayed. It takes about one minute for SUNS TS-2000 to go through self-test. LCD will also display a timer count down from 60 second during this test. Push the OFF button will turn off the unit. 2. When self-test is completed, LCD will then display the number of people passing through the gate and the number of alarm activated. Green ready light is on, it is ready for individual to pass through metal detector. There are one set of red and green LEDs on the entrance side also. Entrance side

4.2 Setting Adjustment Press SETUP button, the LCD displays INPUT PASSWORD. Enter 2367 (factory preset password) to enter adjust mode. 4.2.1 Sensitivity and Volume Adjustment. Press SENSOR to increase sensitivity or Sensor decrease sensitivity. The adjustable range is from 0-99. Use a testing piece similar in size, shape and composition to the smallest forbidden target to test the setting. Press VOLUME to increase volume or VOLUME decrease volume. The adjustable range is from 1-9. Press the SETUP to go to next setting options or press SAVE to save and exit user setting menu. 4.2.2 Infrared Detector and Alarm Sound Adjustment. Press SENSOR or Sensor to turn on or turn off Infrared Detector. Press VOLUME to increase pitch of alarm or VOLUME decrease the pitch of alarm. Press the SETUP to go to next setting options or press SAVE to save and exit user setting menu. 4.2.3 Change Password If you don t want to change password, press SETUP twice to go to next menu. To change password: Enter a four-digit password (use only combination of 2, 3, 6, 7. Can repeat same number). Press the SETUP to go to next setting options or press SAVE to save and exit user setting menu. 4.2.4 Reset to Factory Setting Press SENSOR or Sensor to select factory setting or keep your setting (USER Setting). Press VOLUME or VOLUME zero the counter or keep no change to the counter.

4.2.5 Complete Setting Press SAVE to complete setting adjustment and exit to normal operation mode. to cancel the changes you just make, press SETUP. If you would like 4.3 Operator Setting Adjustment This unit allow operator to adjust the volume and reset the counter without need to enter password. 4.3.1. Counter Reset Press button 6 Sensor for 5 seconds to enter counter reset mode. Press button 2 Sensor to toggle from Counter Keep to Counter Clear and then press Save 4.3.1. Volume Adjustment Increase volume: Press button 3 VOLUME for 5 seconds to enter volume adjustment. button 3 VOLUME again to increase the volume. Press Save to save the setting. Decrease volume: Press button 7 VOLUME for 5 seconds to enter volume adjustment. button 7 VOLUME again to decrease the volume. Press Save to save the setting. Press Press 4.4. Detection If the metal object carried by the individual is bigger than the minimum size of metal allow for the setting, alarm will be sounded and read Alarm LED will be on and NO ENTRY will be display on the LCD panel. Entrance side LED will turn red.

5. MAINTENANCE & REPAIR 5.1. Periodic maintenance Periodic maintenance of the equipment requires only inspection for loose or damaged parts and cleaning of the exterior surfaces. *Open the access door of the Detection Unit and check that all connectors are snapped securely and that all screws and nuts are in place. * Inspect the windows of the IR Sensor to make certain they are not blocked in any way. * Check to make certain that the eight (8) screws that attach the Crosspiece and Detection Unit to the Panels are in place and tight. * Check to make certain that the archway sits flat on the floor and does not sway or rock. * If the power cord is at floor level, check for frayed or broken wires. Replace immediately. * Clean exterior surfaces with mild soap and water only. If a solvent is necessary for heavy cleaning, use only denatured alcohol. Test the detector daily, or whenever the environment changes. 5.2. Repair There are no user-adjustable controls inside the unit. Should the equipment ever fail to perform properly, contact the seller for the name of the nearest field service representative, or contact the factory. 6. TECHNICAL SPECIFICATIONS 6.1 Dimensions Passage Interior: Width: 30 (0.76m) Height: 80 (2m) Depth: 23 (0.58m) Overall Exterior: Width: 35 (0.9m) Height: 87 (2.2m) Depth: 23 (0.58m) Shipping: Width: 35.5 (0.9m)Height: 92 (2.3m) Depth: 6.5 (0.17m) Shipping Weight: 143 lbs (65 kg) 6.2 Operating Conditions Temperature: -4 F (-20 C) to +158 F (70 C) Humidity: Up to 95% non-condensing. 6.3 Regulatory Information The TS-2000 meets or exceeds all industry safety and electromagnetic compatibility (EMC) standards and conforms to international directives. The product would have any adverse effects on medical implants, pregnancy, recording media or magnetic strips. Any recommendations or directives issued by personal physicians should be followed