Report Classification Report on Burning Behaviour

Similar documents
~~oeti. Report VN71 O Classification Report. Reference

Report Test Report

~,oeti. Report VN Classification Report. Reference

Report VNLF Test Report

Report VNNF Test Report

Analysis Report

TFI Report Classification

Analysis Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

TFI Report Classification

BCTC CARPET TECHNICAL CENTRE

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Reaction to fire classification report No C-rev.1

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

BS EN ISO : 2010

Additional reaction to fire classification report No H

TFI Report Reaction to fire test

Reaction to fire classification report No C

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO : 2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification Report Reaction to fire of building elements DIN EN :2007. Class E


REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS EN ISO : 2010

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Review Fire Test Report

Centexbel. General certification regulations. Construction products

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Test Report No

Prüfurkunde - Test Certificate

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Form: KSD-100:10 Page 1 of 3

This European technical approval

EUROPUMP ATEX Guideline Part II

Classification Report

New European Fire Testing Classification for Construction Products

Üntel is ready for CPR

fermacell AESTUVER Fire Protection Joint Seal M

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Test Report: ICL/H18/9039 Rev 1

ADSDUDPTB Mounting Base

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

IMO Resolution MSC 61(67): Annex 1: Part 2

Centrum stavebního inženýrství a.s.

MANUAL. for heat presses. Secabo TC5 and TC7

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

EN ISO ÖNORM. Edition: (ISO 14937:2009)

Manual OW Caution:

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

MANUAL. for heat press. Secabo TC2

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

DELTA Classification Report

Classification of Fire Performance of Wall and Ceiling Lining Materials

Resilient, textile and laminate floor coverings - Classification (ISO 10874:2009)

CATALYST INSPIRATIONAL TUFTED CARPET COLLECTION

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

YOUR GUIDE TO UNDERSTANDING CPR

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

REFLOW OVEN FT01 Version REFLOW OVEN FT01. (Article number F31105) User s Manual

Fire Protection Scover

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

A6 Safety Monitoring Device

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

Test Report: ICL/CR15/11/087

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

Classification report

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

2005-CVB-R0192 Onderzoek naar de mogelijke invloed van FirePro aërosol op in werking zijnde computerapparatuur

Manual Isolating Barrier D461R1 (Revision 01)

Shipboard incinerators with capacities up to 4000 kw

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

Loss Prevention Standard

Lawnmowers, pedestrian controlled (combustion engine powered)

Physikalisch-Technische Bundesanstalt

This document is a preview generated by EVS

CERTIFICATE OF APPROVAL No ME 5085

LICENCE. to use the European Mark

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

ei DG UV Test EC-Type Examination (Module B) Certificate A.1/3.27 a Penetrations through "B" Class divisions (electric cable transits)

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

CLASSIFICATION REPORT

Contact person Date Reference Page Richard Johansson P (2) Fire Research

LICENCE. to use the European Mark

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Transcription:

Report 65596 Classification Report on Burning Behaviour Applicant WESELER TEPPICH GMBH & CO.KG Emmelsumer Strasse 218 46485 Wesel DEUTSCHLAND Reference Hr. van Soest Application Classification of burning behaviour according to EN 13501-1. Test Material "tretford ECO tile" Material used in testing was anonymized for laboratory purposes. A detaiied sample list is contained in the report. Issuing and Signatures Number of pages contained: 6 Original Issue / Vienna 2011-03-22 / Rm/HA/KK 1472 Translation Authorised for Institute DI (FH) Angelika Hönecke Technology Ing. Judith Pointner m 28 / pointner@oeti.at ÖTI - Institut für Ökobgie, Technik und Innovation GmbH Spengergasse 20 A-1050 Wien Austria Tel. +43 1 5442543-0 Fax +43 1 5442543-10 Email offce@oeli.at Web www.oeli.at FN: 326826b UID-Nr ATU65149029 UniCredit Bank Austria AG BLZ 12000 Konto 23410378800 Iban AT941200023410378800 Swift BKAUATWW Eori ATEOS1000015903 Es gelten ausschießich unsere Allgemeinen Geschäftsbedingungen Onl/ our General Terms and Conditions apply

Report 65596 2 / 6 Contents 1 Order... 2 1.1 Chronology... 2 2 Introduction... 3 3 Details of classified building product... 3 3.1 General... 3 3.2 Description of the building product... 3 4 Test reports and test results for the proof of the classification... 3 4.1 Test report... 3 4.2 Test results... 4 5 Classification and field of application... 4 5.1 Reference for classification... 4 5.2 Classification... 4 5.3 Field of application... 4 6 Limitations... 4 6.1 Validity... 4 6.2 Notice... 5 7 Äquivalenzbeurteilung zur Verwendung in Österreich... 5 8 Remarks... 6 1 Order 1.1 Chronology Date Received Order 2011-02-28 2011-02-28 Classification of burning behaviour according toen 13501-1..

Report 65596 3 / 6 2 Introduction This classification report defines the classification assigned to the building product "tretford ECO tile" in accordance with the test methods fixed in EN 13501-1:2009. 3 Details of classified building product 3.1 General The building product "tretford ECO tile" is defined as flooring, the classification is valid for the end use application described under point 5.3. 3.2 Description of the building product Manufacturing procedure: Material of pile/wear layer: Structure of use surface: Colouring: Secondary backing: Dimensions: bonded pile carpet 80% goat hair / 20% wool (according to the specification by the applicant) loop pile multicoloured unpatterned textile nonwoven backing tiles specification by ÖTI specification by the applicant Mass 4375 g/m² 4100 g/m² Thickness 9.5 mm 9.1 mm Total pile mass -- 1200 g/m² Pile thickness -- 5 mm The applicant of this classification report guarantees the observance of the instructions of the product specification according to EN 1307. 4 Test reports and test results for the proof of the classification 4.1 Test report Laboratory ÖTI Test report number 65595 Date of issue 2011-03-22 Applicant WESELER TEPPICH GMBH & CO.KG Test methods EN ISO 11925-2 und EN ISO 9239-1

Report 65596 4 / 6 4.2 Test results Ignitability, EN ISO 11925-2 Test results (Mean Value) Number of tests Flame spread 150 mm yes 6 Burning behaviour, EN ISO 9239-1 Critical radiant flux 5.1 kw/m² 3 Integral of smoke obscuration 305 %.min 3 5 Classification and field of application 5.1 Reference for classification This classification has been carried out in accordance with EN 13501-1:2009. 5.2 Classification Due to the results of the tests carried out, the building product "tretford ECO tile" can be classified as following. Burning behaviour Cfl Smoke emission s1 Classification Cfl-s1 5.3 Field of application The classification is valid for the building product described in point 3 under the following end use conditions. Application Subfloors Installation Horizontal laid floor covering in form of tiles Not burnable subfloors of euroclass A1fl or A2fl with a density of at least 1350 kg/m³. unglued and glued/adhered 6 Limitations 6.1 Validity The report stays valid as long as the products are produced in unchanged condition; this is in the responsibility of the manufacturer.

Report 65596 5 / 6 6.2 Notice This classification document does not represent type permission or certifying the product. If a building product should be CE marked according to system 3 of the attestation of conformity systems, the classification stated with this report is suitable as a basis for the declaration of the producer according to the attestation of conformity system 3, together with a CE marking in the context of the directive relating to construction products. If the manufacturer plans a CE marking in connection with conformity system 3, he has to give an explanation, which has to be attached to the relevant documents. This explanation confirms, that there are no the specific materials, production processes or procedures (e.g. no additives of flame retarding materials, delimitation of organic components or additions of fillers), which are improfing the burning behaviour to reach the obtained fire classification. As a consequence from this, the manufacturer drew the conclusion that the system 3 of the attestation of conformity systems is appropriate. The testing laboratory therefore has played no role in the sampling procedure, although the testing laboratory keeps appropriate references from the manufacturer ready, in order to pursue the examined samples. 7 Äquivalenzbeurteilung zur Verwendung in Österreich Unter Zugrundlegung der Anforderungsbedingungen ist eine eindeutige Zuordnung der ehemaligen österreichischen Brandklassifizierung zu einer europäischen Klasse nicht immer möglich und bedarf umfassender Einstufungserfahrung. Die vorliegende Äquivalenzbeurteilung soll als Hilfestellung verstanden werden die zeigen soll, in welche europäische Klasse ein Bauprodukt fallen kann, das gemäß österreichischen Normen eingestuft wurde und umgekehrt. Einstufung gemäß EN 13501-1 A1fl A2fl-s1 Bfl-s1 Cfl-s1 Dfl-s1 A2fl-s2 Bfl-s2 Cfl-s2 Dfl-s2 Anforderungen aus landesgesetzlichen Bestimmungen nichtbrennbar, schwachqualmend schwerbrennbar, schwachqualmend normalbrennbar, schwachqualmend normalbrennbar A B1 B2 Efl Ffl 1) leichtbrennbar B3 1) Es wird darauf hingewiesen, dass die Europäische Klasse F auch die Tatsache ausdrücken kann, dass noch gar keine Klassifizierung stattgefunden hat.

Report 65596 6 / 6 8 Remarks Sample Material Without explicit written other agreement testing is destructive and the sample material is transferred to the property of ÖTI, which is entitled to freely decide on storage and disposal. Quality management and accreditations All tests and services are performed under a quality management system according to EN ISO 17025. ÖTI is accredited by several organisations for various tests offered. It also is a Notified Body for several directives with the registration number 0534 (see http://ec.europa.eu/enterprise/newapproach/nando/). The accreditation by the Federal Ministry of Economy, Family and Youth as testing laboratory was repeated under reference 92.714/0560- I/12/2009 (Individual accredited test procedures are marked with the federal laboratory logo), the accreditation for testing and inspection of construction products was given by the OIB (Austrian Institute of Construction Engeineering). Details and other accreditations are given on request and can be found on www.oeti.at. Issuance The valid first issue is done in paper and has single-handed signatures. For reference purposes and filing an unsigned electronic duplicate can be delivered in pdf format. Duplicates and translations will be marked accordingly on the cover sheet. Copyright und Usage Notes It is pointed out, that any alterations, amendments or falsifications of reports not authorized by the issuer of the report will be prosecuted as civil and criminal offences; this especially to the appropriate requirements of ABGB, UrhG, UWG and criminal law and their respective international equivalents. Reports are protected under international copyright laws. Written consent of the ÖTI is required for publications (also in excerpt) and reference to tests for public relation purposes. Reports may only be reproduced in full length. End of Report