Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards

Similar documents
August Safety Subject

Fire Prevention Plan. California State University, Chico

Stillwater Area Community Services Center Inc.

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Flammable Liquid Storage

Workplace FIRE SAFETY

TAMUCC Fire Safety Training

Fire Prevention Plan

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Fire and Smoke Door Inspections Qualified Training 02/03/17

Element 14.7 Fire Prevention and Control 2018

Fire Prevention Plan

Fort Bragg Fire and Emergency Services Division Fire Safety Survey For use of this form, see FB Reg 420-1, the proponent agency for this form is DES.

PROSPECT COLLEGE HEALTH AND SAFETY PLANS FIRE PREVENTION PLAN

Facility Manager Training

Office Safety: Housekeeping

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property

Emergency Action and Fire Prevention

Safety Manual Section 7 Fire/Life Safety

FIRE SAFETY PRACTICES AND PROCEDURES

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Laboratory Information

ADMINISTRATIVE SERVICES MANUAL

Family Foster Home Fire Safety Evaluation Checklist Instructions

Quarterly Safety/Building Inspection Form

Business Fire Inspection. City of Guadalupe

Osceola County Department of Fire Rescue and Emergency Medical Services

Fire/Life Safety Policy

GENERAL AREAS OF INSPECTION

Laboratory Inspection Checklist

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

Fire and Life Safety Review Form

FIRE SAFETY AND PREVENTION POLICY

Fire Safety Guidelines

Apartment Fire & Safety Inspection. City of Guadalupe

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Academic and Administrative Buildings

-SAMPLE- Safety Inspection Checklist: Manufacturing

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) SECTION I GENERAL SAFETY

Enki Health and Research Systems, Inc. WORKPLACE INSPECTION CHECKLIST AND CORRECTIVE ACTION FORM

Fire Prevention Program

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Health and Safety Plans Health and Safety Policy Statement Fire Prevention Plan Objective

Health Care Engineers Fire & Life Safety Boot Camp

Flammable and Combustible Liquids

Fire Prevention Plan

FIRE PREVENTION. Consider installation of a fire sprinkler system.

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

Agency for Health Care Administration

RESIDENCE LIFE FIRE SAFETY. Presented By: Environment, Health, and Safety Office

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

Fire Prevention Plan

Fire Evacuation Plan Davidge Hall. UMB POLICE or

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Office of Residence Life. Director of Residence Life

FIRE PREVENTION AND PROTECTION FACT SHEET

Clackamas Fire District #1 Self Inspection Program. Oregon Fire Code (OFC)

Fire Safety Handbook

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

Flammable Liquids!!!!!

Solutions for Common Problems

School Fire Safety Checklist

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

Consumer Fireworks Retail Sales (CFRS) Facility Requirements.

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

Building and Grounds Self-Inspection Program

Housing and Fire Safety Tips for Your Home & Property. Micki Jones, SFFD Rosemary Bosque, DBI May 6, 2015, SF Main Library

Safety Tips for the Office

2010 Fire Log Fire Log. Annual Fire Safety Report

Safety & Risk Management Policies and Procedures

As a rule, UTMB employees are encouraged to implement the RACE acronym in the case of a fire. RACE is defined as the following:

Building Self-Inspection Program

Accreditation Program: Hospital

ILLINOIS INSTITUTE OF TECHNOLOGY SAFETY POLICY COMMITTEE OFFICE SAFETY POLICY

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

Fire Safety Education in Multi- Unit Residential Buildings

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

University of California, Davis Laboratory Self-Inspection Checklist

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

Plan Review Check List Fire Alarm System

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Warehouse Operations Safety Inspection Checklist

REQUIREMENTS FOR EVENTS AND TEMPORARY STANDS AT FAIRS AND SHOWS

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Fire/General Safety Review Program Key Performance Indicators Environmental Health and Safety

During the holiday season, electrical fires are one of the leading causes of damage to residential structures. Specific causes included:

Fire Safety PPT-SM-FIRESFTY V.A.0.0

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

STANDARD DETAILS & SPECIFICATIONS Spec No _SI _ Rev. Date 10/20/11

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Palm Beach State College Florida s First Public Community College FIRE PREVENTION PLAN

Agency for Health Care Administration

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

Transcription:

Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Life Safety The primary goal of fire safety efforts is to protect building occupants from injury and to prevent loss of life. Property Protection The secondary goal of fire safety is to prevent property damage. Protection of Operations By preventing fires and limiting damage we can assure that work operations will continue.

The Strategy of Preventing a Fire A fire must have three things to ignite and maintain combustion: Fuel Heat Oxygen The basic strategy of fire prevention is to control or isolate sources of fuel and heat in order to prevent combustion. If all three are not present in sufficient quantities a fire will not ignite or a fire will not be able to sustain combustion

Good housekeeping habits are an important part of a safe workplace. Why is good housekeeping important? To reduce amounts of flammable and combustible materials. To reduce ignition hazards. To ensure safe emergency evacuation of occupants. To allow for quick emergency response.

General Housekeeping Guidelines Work areas, aisles, walkways, stairways, and equipment should be kept clear of loose materials, trash, scraps, etc. Never block aisles, fire exits, emergency equipment, or alarm pull stations with equipment or materials. Avoid build up of combustible trash and waste such as paper, wood, cardboard, etc. Keep use and storage of flammables and combustibles to a minimum. Clean up all spills such as grease, oil, or water immediately. A delay could result in accidents.

Storage Guidelines No storage is allowed in corridors and stairwells. A cluttered hallway could slow down emergency evacuation. Storage must not exceed a plane of 18 inches below sprinkler heads or smoke detectors. Storage that breaks this plane may prevent sprinkler heads from fully covering room during a fire. A simulated example of how storage can protrude into 18 inch plane below sprinkler heads.

Storage Guidelines ll storage must be t least 3 ft from lectrical panels. In ome emergency ituations it will be ecessary to access ese panels uickly. Maintain at least a 3ft clearance from heating surfaces, air ducts, heaters, and lighting fixtures. Storage of combustible materials in mechanical rooms is prohibited. Improper Storage in front of Electrical Panel Improper Mechanical Room Storage

Flammable and combustible liquids are potential fuel sources for fires and are present in almost every workplace. It is actually the vapor created by flammable and combustible liquids that ignites and burns. It is important to understand what materials in your work area are flammable and combustible so that you may properly store and isolate them from ignition sources.

How do I tell what s flammable? NFPA classification system The NFPA diamond is an easy way to determine the safety risks associated with hazardous materials. To determine a materials flammability refer to the red section of the diamond. A number in this section will indicate the flammability rating of the material. The following numbering system is used to indicate flammability 0- will not burn 1- must be preheated to burn 2-ignites when moderately heated 3-ignites at normal temperature 4-extremely flammable NFPA Diamond

NFPA Classification System Continued... Where can I find NFPA diamonds? Product labels Material Safety Data Sheets (ask your supervisor for them) How do I determine the flammability of chemicals that don t use the NFPA classification system? The flashpoint of a chemical may be used to determine its flammability. Flashpoint information may be found on product labels or MSDS sheets.

Flammable and Combustible Liquids Continued... Flammable liquids are considered flammable because their flashpoints are < 100ºF. This means that flammable liquids burn easily at normal working temperatures. Combustible liquids have a flashpoint at or above 100ºF. These liquids are less hazardous than flammable liquids but still pose a risk. The volatility of flammable and combustible liquids requires special storage and handling

Storing Flammable and Combustible Liquids Flammable liquids must be stored away from ignition sources in cool, well ventilated areas away from incompatible materials Limit the amount of flammable and combustible liquids to the minimum amount necessary. As a general rule, No more than 10 gallons of flammable materials should be outside of approved flammable liquid storage cabinets or approved storage rooms. Room storage limits of flammable and combustible materials depend on various factors such as sprinklers, and storage cabinets. Refer to the table on the following slide for storage guidelines.

I.S.U. Flammable Liquid Storage 1. Room Storage Limits for Flammable and Combustible Liquids, bles Flash point ( F) Boiling point ( F) Non Sprinkled Building Limits Non Sprinkled Bldg. & Flammable Liquid Storage Cabinet Sprinkled Building <73 F <100 F 10 gal. 20 gal. 10 gal 40 gal. <73 F >100 F 10 gal. 40 gal. 10 gal 80 gal. bles > 73 & NA 10 gal. 60 gal. 10 gal 120 gal. ble <100 F >100 & NA 30 gal. 60 gal. 60 gal. 90 gal. tibles <140 F -A tibles >140& <200 F NA 50 gal. 100 gal. 100 gal. 150 gal. ontainers other than safety cans shall not be greater capacity than one (1) gallon. The number of gallon safety cans shall not exceed five (5). The number of one (1) gallon safety cans in use storage cabinets shall not exceed ten (10). Sprinkled Bldg./Flammable Liquid Storage Cabinet

Fire Safety-Electrical Issues Electrical hazards are the cause of numerous workplace fires each year. Faulty electrical equipment or misuse of equipment produces heat and sparks that serve as ignition sources in the presence of flammable and combustible materials. Examples of common ignition hazards: overloading circuits use of unapproved electrical devices damaged or worn wiring

Electrical Fire Safety Extension cords Extension cords are only approved for temporary use. They may only be used for a period of three days or less. Instead of using extension cords contact Facilities to install permanent wiring. When using extension cords check for defaults such as frays, brittleness, or broken wires. Never place extension cords in high traffic areas where they can be damaged by being stepped on or run over by equipment.

Electrical Fire Safety Multi-plug strips Should only be used for office equipment such as computers, printers, and fax machines. Other common items such as microwaves, refrigerators, and copy machines must be plugged directly into wall outlets. This is a requirement of the State Fire Marshal. Multi-plug strips should have a fuse or circuit breaker and be UL approved.

Electrical Fire Safety void the following mproper and hazardous ractices: Never use three prong adapters that allow a three pronged plug to plug into a two prong outlet. Never use any item with a damaged or frayed electrical cord. Space Heaters are not allowed in campus buildings unless approved. Never daisy chain or piggy back multi-plug strips and electrical cords (plugging strips and cords into each other). Piggy-backed multi-plug strips

Compartmentalization Buildings are designed to prevent fire, heat, and smoke from spreading beyond locations of origination. Building elements such as fire walls, fire dampers, and fire doors, are designed to seal off one location from the next. This system is called compartmentalization. Compartmentalization increases the safety of evacuating building occupants because smoke and fire are not able to escape into exit passageways. Containment of fire and smoke reduces property damage and prevents small fires from growing into large fires. In order for compartmentalization efforts to be effective

What s A Fire Door? Fire doors are designed to withstand fire, heat and smoke for a period of 20-minutes to 3 hours. Did you know that corridor office doors are fire doors and should have a 20 minute rating? Corridor laboratory doors should have a 60 minute rating. Fire Doors are required to: Be Self Closing: fire doors should have a door closure that pulls doors completely shut after the door has been opened Have Positive latching: a positive latch locks a door in place so can

4 Reasons Not to Wedge Open Fire Doors For the safety of your buildings occupants. If a fire occurs in a location where the fire door has been wedged, smoke and heat will travel freely into exit corridors hindering or preventing occupant evacuation. It s State Law Periodically the Texas State Fire Marshal inspects our campus and issues numerous citations for wedging or blocking open doors. 3 To reduce or prevent damage to property, research, personal belongings, etc. - Keeping your door shut will keep out smoke or fire originating in other locations. 4 To hold open your door you may have an electro-magnetic device installed. - This device releases a fire door upon activation of the fire alarm allowing it to close and latch.

Maintaining Fire Barriers Fire doors need occasional maintenance and repairs to function properly and should be periodically checked. To test a fire door: Open the door fully and allow it to swing shut. The door should close and latch completely by itself. Give the door a push after it closes to ensure that the latch has engaged. If the door is not operating properly contact FP&M for repairs. Ceiling, Floor, Wall Penetrations All areas should be properly sealed to prevent the escape of fire, heat and smoke. Common penetrations include holes in walls, around ducts, pipes, etc. These types of penetrations should be sealed with appropriate firestopping material.

Points To Remember Housekeeping Issues Keep your worksite clean and free of trash and debris. Follow proper storage guidelines. Flammable and Combustible Liquids Use and store the minimum amounts necessary. Follow correct storage guidelines. Electrical Fire Hazards Don t use unapproved electrical devices. Avoid improper uses of multi-plugs. Compartmentalization Maintain compartmentalization systems. Don t wedge or block open doors.