IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Similar documents
PH:

PH:

Innovative Lighting Smooth Light Recessed Luminaires

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

LED Dusk to Down Fixture

INSTALLATION INSTRUCTION In-Ground

INSTALLATION INSTRUCTION In-Ground Color Changing

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Lumination TM Volumetric Retrofit Kit

Lumination TM Controls Accessory LPL Series Controller Box

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

MAXLITE RKT LED Retrofit Kit

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

Installation Instructions

Installation Instructions

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions PANOS 5.25

IMPORTANT SAFETY INSTRUCTIONS:

SOLA SM II Light Engine Instruction Manual

FES - Series Portable Electric Heaters

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Illuminated Stopper Station Push Button

DHL-LP-LED Low Profile LED Linear High/Low Bay

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

PANOS. Installation Instructions Square, 5.25 Round Flangeless, Downlight. The following installation instructions relate to the options below

Fillmore Small Pendant Assembly and Installation Instructions

AGA TOTAL CONTROL. Model No. - TC3 & TC5

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

INSTALLATION INSTRUCTIONS

Installation Instructions If you have questions, call or visit our website at:

MaxLite LED Round Pendant Highbay Series

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Lunera Smart T8 4ft. Installation Guide. Installation Description

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

Wireless Outdoor Air Reset Adaptor PN:

SOLA SM and SOLA SM 365 Light Engine Instruction Manual

INSTALLATION INSTRUCTIONS

QAA 142 Termination instructions Self-regulating trace heaters type ELSR-NA and -HA in Div1 with heater entry kit EL-HAZELECT Kit part No: 09CA051

INSTALLATION INSTRUCTIONS

GLED INSTALLATION INSTRUCTIONS

LED Seamless VaporProof Fixture

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

WPLED 26W INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

GLED INSTALLATION INSTRUCTIONS

Operation & Care Instructions Save For Future Reference ABOUT THE MACHINE

AGA TOTAL CONTROL. Model No. - TC3

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

1 x4 Dimmable LED RetroFits

SSC-1D installation guide

USER GUIDE & INSTALLATION INSTRUCTIONS

Installation Instructions If you have questions, call or visit our website at:

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

IMPORTANT SAFETY INSTRUCTIONS:

Aquatron 4, 8, /95 Form Number Instructions For Use. Advance Models , , , ,

INSTALLATION INSTRUCTIONS NeoSol DS LED Horticulture Fixture

Draft - develop and review

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

ELSTON 52 CEILING FAN

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation

Occupancy Sensor OCS 100W Setup Guide

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Hanson LED C e i l i n g F a n

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

LS Condensate Removal Pump Installation, Operation and Service Instructions

52 BERKSHIRE CEILING FAN

LED IMPORTANT SAFETY INSTRUCTIONS

110 lm w STANDARD SERIES

Instruction Manual. ESCORT558O Version 1.1

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Installation Instructions

UV/White LED Light Source Kit

Certificate of Compliance

IMPORTANT SAFETY INSTRUCTIONS:

Installation Instructions

52 CEILING FAN. Owner s Manual Models #50336, 50337

Installation Instructions

MaxLite LED High Bay Fixtures

Innovative Lighting R-Series Overhead LED Conversion Kits

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

Honeywell Durafit LED Retrofit Kit

Stopper II SERIES ADA. We protect the things that protect you

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

1 General Description

Installation, Operation and Maintenance Manual

1495D. Installation and Operation Manual, 230 Voltage 2/16/2017

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

Installation Manual. Models 99168, 99169, 99170

Installation Instructions

Smart Security at Every Corner of Your Home

standards: standards:

Transcription:

INSTALLATION AND MAINTENANCE MANUAL StarPower Link LED Luminaire (Damp Location) Document No: 0077 Rev B Apr. 2015 IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician. StarPower Link LED Luminaire MODEL #s SP-N-x-LS SP-W-x-LS A: Introduction The light is designed to illuminate commercial, industrial and institutional locations. StarPower Link can be operated from any nominal 120-277V, 50/60Hz AC supply without any variation in light output. The luminaire is compatible with 0-10V dimmers. Models SP-x are all suitable for damp location per UL 1598.

B: Warnings SUITABLE FOR DAMP LOCATIONS. CONVIENT AUX EMPLACEMENTS HUMIDES. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS. REMOVE PRODUCT FROM PACKAGING AND CONFIRM IT IS FREE OF DAMAGE PRIOR TO INSTALLATION. ENLEVEZ LE PRODUIT DE L EMBALLAGE ET VERIFIEZ QU IL N EST PAS ENDOMMAGE AVANT L INSTALLATION. DISCONNECT POWER PRIOR TO ANY INSTALLATION. DÉBRANCHEZ LE COURANT AVANT TOUTE INSTALLATION. CAP ALL WIRING CONNECTIONS WITH UL APPROVED WIRE CONNECTORS. COUVRIR TOUTES LES CABLES AVEC DES CONNECTIONS APPROUVES (UL). VERIFY SUPPLY VOLTAGE MEETS LUMINAIRE LABEL SPECIFICATIONS. VÉRIFIEZ QUE LA TENSION SOIT COMPATIBLE AVEC LES CARACTÉRISTIQUES DU LUMINAIRE MARQUE SUR L ETIQUETTE. ALLOW FIXTURE TO COOL BEFORE TOUCHING HEATSINK OR LIGHT SOURCE. LAISSEZ LE PROJECTEUR REFROIDIR AVANT DE TOUCHER LE RADIATEUR OU LA SOURCE DE LUMIÈRE. DO NOT ATTEMPT TO OPEN OR MAKE REPAIRS INSIDE LUMINAIRE. NE PAS TENTER D OUVRIR OU DE FAIRE DES REPARATIONS A L INTERIEUR DU LUMINAIRE. CLEAN LENS, WHENEVER NECESSARY, WITH CLEAN WARM WATER OR A NON-ABRASIVE EPA APPROVED SOLUTION WHICH WILL NOT SCRATCH SURFACE. NETOYEZ L OBJECTIF CHAQUE FOIS QUE NECESSAIRE, A L EAU TIEDE PROPRE OU AVEC UNE SOLUTION NON ABRASIVE EPA APPROUVEE, ET QUI NE RAYERA PAS LA SURFACE. AVOID DIRECT VIEWING OF LIGHT SOURCE. EVITEZ DE REGARDER DIRECTMENT LA SOURCE LUMINEUSE. THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN. CE PRODUIT DOIT ÍTRE INSTALLÈ PAR UN ÈLECTRICIEN QUALIFIÈ. Page 2 of 6

C: System Overview Junction Box 120-277 Vac MAX LENGTH PER POWER FEED 120 VAC 100 Ft 277 VAC 200 Ft SLEEVE COVER PF (POWER FEED) *Carries branch circuit and 0-10v dimming to junction box LC (LINK CONNECTOR) *Carries branch circuit and 0-10v dimming between fixtures D: Installation 1. Shut off power. 2. Inspect mounting location for damage. Make sure the structure can support the weight of the StarPower Link fixture. StarPower Fixture Weight 4 ft. fixture 8 lbs. max 8 ft. fixture 16 lbs. max 3. Remove StarPower Link Fixture from package and inspect for damage. 4. Determine mounting method. Follow all UL, NEC and minimum load rating guidlines when selecting and installing a chain, cable, or rod. Surface Pendant - Cable Pendant - Chain Pendant Rod- Rod PROCEED TO STEP 5 CUSTOMER SUPPLIED CABLE, CHAIN OR ROD PROCEED TO STEP 10 Page 3 of 6

Fixture Mounting - Surface 5. If necessary, adjust mount bracket location by sliding bracket to desired position. 6. Tighten set screw to lock bracket in place. 7. Attach first fixture to structure. Front View 8. Support second fixture and insert LINK CONNECTOR from previously installed fixture. 9. Confirm LINK CONNECTOR is locked to mating socket and attach fixture to structure. PROCEED TO STEP 15 Page 4 of 6

Fixture Mounting - Pendant 10. If necessary, adjust mount bracket by loosening (2) cap nuts and sliding pendant mount bracket to desired position. 11. Re-install lock washer and cap nut, fully tighten before installing StarPower Link. 12. Attach first fixture to suspension hardware. 13. Attach second fixture to suspension hardware and align with first fixture. Insert LINK CONNECTOR from first fixture to second and confirm connector has locked to mating socket. 14. Slide SLEEVE COVER over exposed end of second fixture. PROCEED TO STEP 15 Page 5 of 6

Power Feed Installation 15. Power must be turned OFF prior to disconnecting or reconnecting POWER FEED or LINK CONNECTORS. 16. Confirm all fixtures are connected with the provided LINK CONNECTOR. 17. Locate POWER FEED cord. 18. Wire non-connector end of POWER FEED cord to AC line using NRTL listed wire connectors, junction box and strain relief approved for use with cord diameters of.66. Green (ground), black (line), white (neutral), pink (positive dimming), orange (negative dimming) *Refer to fig.1 for wiring diagram 19. Connect POWER FEED cord to fixture. POWER FEED cord can be connected to either end of StarPower Link fixture. 20. Turn on power. fig1. Wiring Diagram 0-10V Dimming Line Neutral Ground (-)Negative Dimming (+)Positive Dimming Black White Green Orange Pink StarPower Page 6 of 6